BURNDY Compression TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW DIE AND COLOR CODE INFORMATION BEVELED ENTRY INSPECTION WINDOW CRIMP TYPES YAZ-2N, YAZ-2TC ELECTRO-TIN PLATED CABLE ACCOMMODATION B C-54 UL LISTED 90 C, 600 VOLT TO 35 KV B B 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Conductor Catalog Number YAZV10-2TC14 YAZV10-2TC14-45 YAZV10-2TC14-90 YAZV10-2TC14E2 YAZV10-2TC14E2-45 YAZV10-2TC14E2-90 YAZ8C-2TC10 YAZ8C-2TC10-45 YAZ8C-2TC10-90 YAZ8C-2TC10E2 YAZ8C-2TC10E2-45 YAZ8C-2TC10E2-90 YAZ8C-2TC14 YAZ8C-2TC14-45 YAZ8C-2TC14-90 YAZ8C-2TC14E2 YAZ8C-2TC14E2-45 YAZ8C-2TC14E2-90 YAZ8C-2TC14E1 YAZ8C-2TC14E1-45 YAZ8C-2TC14E1-90 YAZ8C-2TC38 YAZ8C-2TC38-45 YAZ8C-2TC38-90 YAZ6C-2N YAZ6C-2N-45 YAZ6C-2N-90 YAZ6C-2TC10E2 YAZ6C-2TC10E2-45 YAZ6C-2TC10E2-90 Fig *** # AWG MM2 1 2 3 14-10 AWG 6 1 2 3 1 2 3 1 2 3 1 #8 STR 2 3 #6 SOL 1 10 2 37/24 3 1 2 3 1 2 3 1 2 3 #6 AWG 1 2 3 Stud Stud Hole Hole Tongue Size Spacing Width 1/4 5/8 .41 1/4 3/4 .41 #10 5/8 .41 #10 3/4 .41 1/4 5/8 .44 1/4 3/4 .44 1/4 1 .44 3/8 1 .58 1/2 1-3/4 .83 #10 3/4 .42 Figure Dimensions (B) (T) (L) 2.16 .69 .05 2.03 1.45 2.28 .69 .05 2.16 1.58 2.20 .75 .08 2.09 1.37 2.33 .75 .08 2.22 1.50 2.33 .75 .08 2.20 1.49 2.45 .75 .08 2.33 1.62 2.70 .75 .08 2.58 1.87 2.89 .75 .06 2.72 2.05 4.40 1.12 .12 4.29 3.28 2.65 1.12 .09 2.48 1.51 (# of crimps) Mechanical MD6, OUR840 MD7-34R Y8MRB-1 (2) - Dieless - - - - 3/4 W8CVT (2) W8CRT (2) X8CRT (2) U8CRT (2) Red 49 7/8 Y2MR (2) MY29-3 (2) W5CVT (2) W5CVT (2) MY29-11 (2) W5CRT (2) X5CRT (2) MRC840 (2) X5CRT (2) X5CRT (2) Y644M (1) X8CART (2) X8CART (2) Y1MR (2) U5CRT (2) U8CABT (2) Blue 7 or 1-1/16 374 Y1MR (2) Y8MRB-1 (2) W8CVT (2) Y2MR (2) W8CRT (2) MY29-3 (2) X8CRT (2) MY29-11 (2) MRC840 (2) See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. The MM2 conductor size referred to here is for Class 2 and Class 5 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length BURNDY Compression B TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Conductor Catalog Number YAZ6C-2TC14 YAZ6C-2TC14-45 YAZ6C-2TC14-90 YAZ6C-2TC14E2 YAZ6C-2TC14E2-45 YAZ6C-2TC14E2-90 YAZ6C-2TC14E1 YAZ6C-2TC14E1-45 YAZ6C-2TC14E1-90 YAZ6C-2TC38E2 YAZ6C-2TC38E2-45 YAZ6C-2TC38E2-90 YAZ6C-2TC38E6 YAZ6C-2TC38E6-45 YAZ6C-2TC38E6-90 YAZ6C-2TC38 YAZ6C-2TC38-45 YAZ6C-2TC38-90 YAZ5C-2N YAZ5C-2N-45 YAZ5C-2N-90 YAZ4C-2N YAZ4C-2N-45 YAZ4C-2N-90 YAZ4C-2TC10-E2 YAZ4C-2TC10-E245 YAZ4C-2TC10-E290 YAZ4C-2TC14 YAZ4C-2TC14-45 YAZ4C-2TC14-90 YAZ4C-2TC14E2 YAZ4C-2TC14E2-45 YAZ4C-2TC14E2-90 YAZ4C-2TC38 YAZ4C-2TC38-45 YAZ4C-2TC38-90 YAZ3C-2N YAZ3C-2N-45 YAZ3C-2N-90 YAZ3C-2TC14 YAZ3C-2TC14-45 YAZ3C-2TC14-90 YAZ3C-2TC14E2 YAZ3C-2TC14E2-45 YAZ3C-2TC14E2-90 YAZ3C-2TC38E2 YAZ3C-2TC38E2-45 YAZ3C-2TC38E2-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG #6 AWG #5 AWG #4 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 1/4 5/8 .45 1/4 3/4 .45 1/4 1 .45 - - - #3 AWG 3/8 3/4 .58 3/8 7/8 .58 3/8 1 .58 1/2 1-3/4 .83 1/2 1-3/4 .83 #10 3/4 .49 1/4 5/8 .49 1/4 3/4 .49 3/8 1 . .58 1/2 1-3/4 .83 1/4 5/8 .55 25 #2 SOL 1/4 3/4 .55 3/8 3/4 .58 See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. B B Figure Dimensions (B) (T) (L) 2.65 1.12 .08 2.45 1.51 2.78 1.12 .08 2.58 1.63 3.03 1.12 .08 2.83 1.63 2.97 1.12 .06 2.72 1.81 3.09 1.12 .06 2.85 1.94 3.22 1.12 .06 2.97 2.06 4.43 1.12 .12 4.31 3.28 4.42 1.12 .12 4.30 3.30 2.67 1.12 .09 2.49 1.54 2.67 1.12 .09 2.49 1.54 2.80 1.12 .09 2.61 1.66 3.23 1.12 .08 3.01 2.09 4.58 1.25 .12 4.41 3.32 2.83 1.25 .09 2.59 1.55 2.95 1.25 .09 2.72 1.68 3.14 1.25 .08 2.88 1.86 Dieless (# of crimps) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length Y1MR (2) W5CVT (2) W5CVT (2) Y2MR (2) W5CRT (2) X5CRT (2) MY29-3 (2) X5CRT (2) X5CRT (2) MY29-11 (2) X8CART (2) X8CART (2) MRC840 (2) Y644M (2) U5CRT (2) U8CABT (2) Blue 7 or 374 1-1/6 1/16 W5CRT (2) W5CVT (2) X5CRT (2) W5CVT (2) W5CRT (2) X5CRT (2) U5CRT (2) Blue 7 or 374 W4CVT (2) W4CRT (2) X4CRT (2) W4CVT (2) W4CRT (2) X4CRT (2) U4CRT (2) U6CABT (2) Gray 8 or 1-1/16 346 W3CRT (2) W3CRT (2) U3CRT (2) White Y1MR (4) Y2MR (4) MY29-3 (2) MY29-11 (2) MRC840 (2) Y644M (2) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). 9 1-5/16 For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. C-55 BURNDY Compression B TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Figure Dimensions (B) (T) (L) 3.39 1.25 .08 3.13 2.11 4.60 1.25 .12 4.32 3.32 2.85 1.25 .11 2.65 1.58 2.85 1.25 .11 2.65 1.58 2.97 1.25 .11 2.77 1.71 3.22 1.25 .11 3.02 1.96 3.03 1.25 .11 2.84 1.77 3.16 1.25 .11 2.96 1.90 3.28 1.25 .11 3.09 2.02 3.41 1.25 .11 3.21 2.14 4.16 1.25 .11 3.96 2.90 4.76 1.38 .12 4.45 3.34 3.01 1.38 .10 2.75 1.60 3.13 1.38 .10 2.87 1.73 3.57 1.38 .10 3.31 2.16 4.79 1.38 .11 4.52 3.38 Mechanical MD6, OUR840 MD7-34R Conductor C-56 Catalog Number YAZ3C-2TC38 YAZ3C-2TC38-45 YAZ3C-2TC38-90 YAZ2C-2N YAZ2C-2N-45 YAZ2C-2N-90 YAZ2C-2TC10E2 YAZ2C-2TC10E2-45 YAZ2C-2TC10E2-90 YAZ2C-2TC14 YAZ2C-2TC14-45 YAZ2C-2TC14-90 YAZ2C-2TC14E2 YAZ2C-2TC14E2-45 YAZ2C-2TC14E2-90 YAZ2C-2TC14E1 YAZ2C-2TC14E1-45 YAZ2C-2TC14E1-90 YAZ2C-2TC516E2 YAZ2C-2TC516E2-45 YAZ2C-2TC516E2-90 YAZ2C-2TC38E2 YAZ2C-2TC38E2-45 YAZ2C-2TC38E2-90 YAZ2C-2TC38E6 YAZ2C-2TC38E6-45 YAZ2C-2TC38E6-90 YAZ2C-2TC38 YAZ2C-2TC38-45 YAZ2C-2TC38-90 YAZ2C-2NTC38 YAZ2C-2NTC38-45 YAZ2C-2NTC38-90 YAZ1C-2N YAZ1C-2N-45 YAZ1C-2N-90 YAZ1C-2TC14 YAZ1C-2TC14-45 YAZ1C-2TC14-90 YAZ1C-2TC14E2 YAZ1C-2TC14E2-45 YAZ1C-2TC14E2-90 YAZ1C-2TC38 YAZ1C-2TC38-45 YAZ1C-2TC38-90 YAZ25-2N YAZ25-2N-45 YAZ25-2N-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG #3 AWG #2 SOL #2 AWG #1 AWG 1/0 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 25 3/8 1 .58 1/2 1-3/4 .83 #10 3/4 .60 1/4 5/8 .60 1/4 3/4 .60 1/4 1 .60 5/16 3/4 .60 3/8 3/4 .60 3/8 7/8 .60 3/8 1 .60 35 3/8 1-3/4 .60 1/2 1-3/4 .83 1/4 .67 5/8 50 - 1/4 3/4 .67 3/8 1 .67 1/2 1-3/4 See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. B B .83 Dieless (# of crimps) Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W3CRT (2) W3CRT (2) Y1MR (4) Y2MR (4) MY29-3 (2) MY29-11 (2) MRC840 (2) W2CVT (2) W2CVT (2) Y644M (1) W2CRT (2) W2CRT (2) X2CRT (2) X2CRT (2) Y1MR (4) MY29-3 (2) W1CVT (2) W1CVT (2) MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2) MRC840 (2) X1CRT-1 (2) X1CRT-1 (2) Y644M (1) MY29-3 (2) W25RT (4) W25VT (4) MY29-11 (2) W25VT (4) X25RT (4) MRC840 (4) X25RT (4) W25RT (4) Y644M (1) ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. U3CRT (2) White 9 U2CRT (2) Brown 10 1-5/16 U1CRT-1 (2) U4CABT (2) Green 11 or 1-7/16 375 U25RT (2) U2CABT (2) Pink 12 or 1-7/16 348 1-5/16 " Available undrilled. Add suffix "U" to catalog number (example: YA25U). For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Figure Dimensions (B) (T) (L) 3.04 .75 1.38 .12 2.81 1.64 3.16 .75 1.38 .12 2.93 1.76 3.41 .75 1.38 .12 3.18 2.01 3.35 .75 1.38 .12 3.12 1.95 3.47 .75 1.38 .12 3.24 2.08 3.60 .75 1.38 .12 3.37 2.20 4.35 .75 1.38 .12 4.12 2.95 4.95 .83 1.50 .12 4.67 3.41 3.20 .83 1.50 .12 2.92 1.66 3.32 .83 1.50 .12 3.05 1.79 3.76 .83 1.50 .12 3.48 2.22 4.98 .91 1.50 .13 4.71 3.44 3.36 .90 1.50 .12 3.08 1.82 3.80 .90 1.50 .12 3.52 2.25 5.15 1.02 1.62 .14 4.86 3.48 3.55 1.02 1.62 .14 3.25 1.86 Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W25RT (4) W25VT (4) X25RT (4) W25VT (4) W25RT (4) W25RT (4) U25RT (2) U2CABT (2) Pink W26VT (4) W26RT (4) X26RT (4) W26VT (4) W26RT (4) X26RT (4) U26RT (2) Black 13 1-9/16 W27VT (4) W27RT (4) X27RT (6) W27VT (4) W27RT (4) X27RT (6) U27RT (2) Orange 14 1-9/16 W28VT (4) W28RT (4) X28RT (6) W28VT (4) W28RT (4) X28RT (6) U28RT (2) Purple 15 1-11/16 Conductor Catalog Number YAZ25-2TC14 YAZ25-2TC14-45 YAZ25-2TC14-90 YAZ25-2TC14E2 YAZ25-2TC14E2-45 YAZ25-2TC14E2-90 YAZ25-2TC14E1 YAZ25-2TC14E1-45 YAZ25-2TC14E1-90 YAZ25-2TC516E6 YAZ25-2TC516E6-45 YAZ25-2TC516E6-90 YAZ25-2TC516 YAZ25-2TC516-45 YAZ25-2TC516-90 YAZ25-2TC38 YAZ25-2TC38-45 YAZ25-2TC38-90 YAZ25-2NTC38 YAZ25-2NTC38-45 YAZ25-2NTC38-90 YAZ26-2N YAZ26-2N-45 YAZ26-2N-90 YAZ26-2TC14 YAZ26-2TC14-45 YAZ26-2TC14-90 YAZ26-2TC14E2 YAZ26-2TC14E2-45 YAZ26-2TC14E2-90 YAZ26-2TC38 YAZ26-2TC38-45 YAZ26-2TC38-90 YAZ27-2N YAZ27-2N-45 YAZ27-2N-90 YAZ27-2TC14E2 YAZ27-2TC14E2-45 YAZ27-2TC14E2-90 YAZ27-2TC38 YAZ27-2TC38-45 YAZ27-2TC38-90 YAZ28-2N YAZ28-2N-45 YAZ28-2N-90 YAZ28-2TC14E2 YAZ28-2TC14E2-45 YAZ28-2TC14E2-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG *** MM2 - Stud Stud Hole Hole Tongue Size Spacing Width 1/4 5/8 1/4 3/4 1/4 1 5/16 7/8 5/16 1 3/8 1 3/8 1-3/4 1/2 1 3/4 1/4 5/8 70 - 1/4 3/4 3/8 1 1/2 1-3/4 1/4 3/4 3/8 1 1/2 1-3/4 1/4 See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. B B 3/4 Dieless (# of crimps) MY29-3 (2) MY29-11 (2) MRC840 (4) Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). 12 or 1-7/16 348 For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. C-57 BURNDY Compression B TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Figure Dimensions (B) (T) (L) 3.99 1.62 .14 3.69 2.30 4.74 1.62 .14 4.44 3.05 5.18 1.62 .16 4.92 3.52 3.99 1.62 .14 3.73 2.34 5.60 2.00 .16 5.23 3.56 4.42 2.00 .16 4.04 2.37 5.64 2.00 .18 5.29 3.60 4.02 2.00 .18 3.66 1.97 4.45 2.00 .18 4.10 2.41 5.81 2.12 .19 5.44 3.64 4.62 2.12 .19 4.25 2.46 5.89 2.13 .21 5.54 3.70 6.04 2.25 .23 5.69 3.73 4.42 2.25 .23 4.06 2.10 4.85 2.25 .23 4.50 2.54 6.45 2.63 .25 6.03 3.77 Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length MY29-3 (2) MY29-11 (2) MRC840 (4) Y644M (1) W28VT (4) W28RT (4) X28RT (6) W28VT (4) W28RT (4) X28RT (6) U28RT (2) Purple 15 1-11/16 MY29-3 (2) MY29-11(2) Y644M (1) W29VT (4) X29RT (8) X29RT (8) W29VT (4) W29RT (4) U29RT (2) Yellow 1-11/16 W30VT (4) W30VT (4) W30RT (4) U30RT (4) U28ART (4) White 17 or 2-1/16 298 W31VT (4) W31VT (4) W31RT (4) U31RT (4) U29ART (4) Red 18 or 2-1/16 324 W32VT (4) W32VT (4) W32RT (4) U32RT (4) U30ART (4) Blue 19 or 2/16 470 W33VT (4) W33VT (4) W33RT (4) U33RT (4) Gray 326 or 2-5/16 538 W34VT (4) W34VT (4) W34RT (4) U34RT (4) U31ART (4) Brown 20 or 2-5/16 299 - - U35RT (4) Yellow Conductor C-58 Catalog Number YAZ28-2TC38 YAZ28-2TC38-45 YAZ28-2TC38-90 YAZ28-2NTC38 YAZ28-2NTC38-45 YAZ28-2NTC38-90 YAZ29-2N YAZ29-2N-45 YAZ29-2N-90 YAZ29-2TC38 YAZ29-2TC38-45 YAZ29-2TC38-90 YAZ30-2N YAZ30-2N-45 YAZ30-2N-90 YAZ30-2TC38 YAZ30-2TC38-45 YAZ30-2TC38-90 YAZ31-2N YAZ31-2N-45 YAZ31-2N-90 YAZ31-2TC14E2 YAZ31-2TC14E2-45 YAZ31-2TC14E2-90 YAZ31-2TC38 YAZ31-2TC38-45 YAZ31-2TC38-90 YAZ32-2N YAZ32-2N-45 YAZ32-2N-90 YAZ32-2TC38 YAZ32-2TC38-45 YAZ32-2TC38-90 YAZ33-2N YAZ33-2N-45 YAZ33-2N-90 YAZ34-2N YAZ34-2N-45 YAZ34-2N-90 YAZ34-2TC14E2 YAZ34-2TC14E2-45 YAZ34-2TC14E2-90 YAZ34-2TC38 YAZ34-2TC38-45 YAZ34-2TC38-90 YAZ35-2N YAZ35-2N-45 YAZ35-2N-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 3/8 4/0 AWG 250 kcmil 1-3/4 1.02 1/2 1-3/4 1.10 - 1/2 185 500 kcmil 550 kcmil 1-3/4 1.20 1 1.20 1-3/4 1.29 3/4 1.29 3/8 1 1.29 1-3/4 1.40 3/8 450 kcmil 1.10 1/4 1/2 400 kcmil 1 150 3/8 350 kcmil 1.02 3/8 1/2 300 kcmil 1 - 3/8 - 240 - 1 1.40 1/2 1-3/4 1.48 1/2 1-3/4 1.55 1/4 3/4 1.55 3/8 1 1.55 1/2 See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. B B 1-3/4 1.65 Dieless (# of crimps) Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). 16 21 2-11/16 For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) 90 T T T 45 L L L Fig. 1 Fig. 2 Fig. 3 Figure Dimensions (B) (T) (L) 6.55 2.69 .27 6.14 3.81 5.55 2.69 .26 5.14 2.81 6.70 2.81 .27 6.26 3.84 6.72 2.81 .27 6.26 3.84 6.82 2.88 .27 6.34 3.87 5.82 2.88 .27 5.34 2.87 5.82 2.88 .27 5.34 2.87 6.82 2.88 .27 6.34 3.87 6.89 2.94 .30 6.46 3.91 6.91 2.94 .31 6.48 3.93 7.08 3.00 .33 6.66 4.02 6.09 3.00 .33 5.66 3.02 7.38 3.19 .38 6.99 4.13 7.41 3.19 .39 7.03 4.16 7.48 3.19 .40 7.10 4.22 7.82 3.44 .42 7.40 4.30 Mechanical MD6, OUR840 MD7-34R Conductor Catalog Number YAZ36-2N YAZ36-2N-45 YAZ36-2N-90 YAZ36-2TC38 YAZ36-2TC38-45 YAZ36-2TC38-90 YAZ37-2N YAZ37-2N-45 YAZ37-2N-90 YAZ38-2N YAZ38-2N-45 YAZ38-2N-90 YAZ39-2N YAZ39-2N-45 YAZ39-2N-90 YAZ39-2NT38 YAZ39-2NT38-45 YAZ39-2NT38-90 YAZ39-2TC38 YAZ39-2TC38-45 YAZ39-2TC38-90 YAZ39-2NNT YAZ39-2NNT-45 YAZ39-2NNT-90 YAZ40-2N YAZ40-2N-45 YAZ40-2N-90 YAZ41-2N YAZ41-2N-45 YAZ41-2N-90 YAZ44-2N YAZ44-2N-45 YAZ44-2N-90 YAZ44-2TC38 YAZ44-2TC38-45 YAZ44-2TC38-90 YAZ45-2N YAZ45-2N-45 YAZ45-2N-90 YAZ453-2N YAZ453-2N-45 YAZ453-2N-90 YAZ46-2N YAZ46-2N-45 YAZ46-2N-90 YAZ47-2N YAZ47-2N-45 YAZ47-2N-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Stud Hole Hole Tongue Size Spacing Width 1/2 600 kcmil 1-3/4 1.74 300 3/8 1 1.74 650 kcmil - 1/2 1-3/4 1.80 700 kcmil - 1/2 1-3/4 1.84 1/2 1-3/4 1.91 3/8 750 kcmil 1 1.63 3/8 1 1.91 1/2 1-3/4 1.63 800 kcmil 400 1/2 1-3/4 1.98 850 kcmil - 1/2 1-3/4 2.01 1/2 1-3/4 2.19 1000 kcmil 500 3/8 1 2.19 1250 kcmil - 1/2 1-3/4 2.46 1300 kcmil - 1/2 1-3/4 2.53 1500 kcmil - 1/2 1-3/4 2.69 1750 kcmil - 1/2 1-3/4 2.90 See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. B B Dieless (# of crimps) Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length - - U36RT (4) U32ART (4) Green 22 or 472 - - U37RT (4) Orange 23 - - U38RT (4) Pink 400 2-7/8 - - U39RT (4) P39RT (4) ** Black 24 2-15/16 - - P40RT (4) ** Orange 25 3 - - - Gold 3 - - P44RT (4) ** White 27 3-1/16 - - P45RT (6) ** Yellow 29 3-1/4 - - - Orange 30 2-1/16 - - P46RT (6) ** Green 31 3-5/16 - - - Gray 3-1/2 33 2/4 2-7/8 For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. C-59 BURNDY TWO HOLE HYLUGTM CODE CONDUCTOR LONG BARREL WITH INSPECTION WINDOW (CONTINUED) B Compression 90 T T T 45 L Fig. 1 Fig. 2 Figure Dimensions (B) (T) (L) 7.89 1/2 1-3/4 3.10 3.44 .46 7.54 4.40 Mechanical MD6, OUR840 MD7-34R Catalog Number YAZ48-2N YAZ48-2N-45 YAZ48-2N-90 Fig *** # AWG MM2 1 2 2000 kcmil 3 Stud Stud Hole Hole Tongue Size Spacing Width See tooling section of this catalog for complete tool and die listings. * Use P-UADP-1 adaptor with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. " Available undrilled. Add suffix "U" to catalog number (example: YA25U). For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions. L L Conductor C-60 B B Dieless (# of crimps) - Fig. 3 Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length - Brown 34 3-1/2