Embedded Power for Business-Critical Continuity Rev.03.22.07 exb30s 1 of 4 EXB30 Series Single output Total Power: 16-30W Input Voltage: 36-75VDC # of Outputs: Single Special Features * High efficiency topology, 92% typical at 5 V * Industry standard footprint * Wide operating temperature, -40 C to +85 C (natural convection) * 80% to 110% output trim * No minimum load * Overvoltage and overtemperature protection * Remote sense compensation * Remote ON/OFF * Available RoHS compliant * 2 year warranty The EXB30 is a new high efficiency open frame isolated 30 Watt converter series in an industry standard footprint. The first five models in the series feature a 2:1 input voltage range of 36 Vdc to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V and 2 V. Each model is trimmable from 80% to 110% except the 12 V output which has a wider trim range of 60% to 110%. The sub 5 V models have an output current rating of 8 A. Typical efficiencies for the models are 92% for the 5 V, 90% for the 3.3 V and 12V, 87% for the 2.5 V and 86% for the 2 V version. The EXB30 series offers remote ON/OFF and remote sense compensation to correct for voltage drops at the load. Overcurrent, overvoltage and overtemperature protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the EXB30 reduces compliance costs and time to market. Embedded Power for Business-Critical Continuity Rev.03.22.07 exb30s 2 of 4 Specifications All specifications are typical at nominal input, full load at 25C unless otherwise stated. OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage adjustability 80% to 110% Set point accuracy 1.5% max. Line regulation Low line to high line 0.1% max. Load regulation Full load to min. load 0.2% max. Total error band 3.0% Minimum load Overshoot 0% At turn-on and turn-off Undershoot Ripple and noise (See Note 1) 5 Hz to 20 MHz Temperature coefficient Transient response (See Note 2) None GENERAL SPECIFICATIONS None Efficiency 150 mV pk-pk 20 mV rms 0.02%/C 2.0% max. deviation 300 s recovery to within total error band Remote sense 10% output voltage change INPUT SPECIFICATIONS Input voltage range 48 Vin nominal Input current Remote OFF No load 10 mA max. 50 mA max. Input current (max.) (See Note 4) 48 V models 1.0 A max. @ Io max. and Vin = 36-75 Vdc Input reflected ripple (See Note 6) Active high remote ON/OFF Logic compatibility ON OFF Conducted emissions EN55022 (See Note 3) Radiated emissions Immunity: ESD air ESD contact Radiated field enclosure Conducted (DC power) Conducted (signal) Input transients 36-75 Vdc 30 mA (pk-pk) typ. EN55022 (See Note 3) Level B EN55022 (See App. Note 108) See table Input/output Switching frequency Fixed Approvals and standards (See Note 5) Undervoltage lockout 48 Vin: power down 48 Vin: power up 31.5 V 34 V Start-up time (See Note 7) Power up Remote ON/OFF 30 ms 30 ms 1500 Vdc 300 kHz typ. VDE0805, EN60950 IEC950, UL/cUL1950 CSA C22.2 No. 950 Material flammability UL94V-0 Weight 40 g (1.41 oz) MIL-HDBK-217F >300,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance temperature Non-operating Operating ambient Altitude Non-operating -40 C to +85 C -40 C to +125 C ETS 300 019-2-3 Open collector ref to -input Open circuit or >2 Vdc <1.2 Vdc Level B EN61000-4-2 8 kV (NP), 15 kV (RP) EN61000-4-2 6 kV (NP), 8 kV (RP) EN61000-4-3 10 V/m (NP) EN61000-4-6 10 V (NP) EN61000-4-6 10 V (NP) ETS 300 132-2, ETR 283 Basic insulation MTBF @ 25 C, 100% load ground benign Level A Classes T3.1 to T3.5 Operating 40,000 feet max. 10,000 feet max. Embedded Power for Business-Critical Continuity Rev.03.22.07 exb30s 3 of 4 Specifications Contd. OUTPUT INPUT OUTPUT POWER OVP VOLTAGE VOLTAGE (MAX.) OUTPUT CURRENT (MIN.) OUTPUT CURRENT (MAX.) EFFICIENCY REGULATION (TYP.) LINE LOAD 2.3 Vdc 2V 0A 8A 86% 0.1% 0.2% EXB30-48S2V0J (EOL) 36-75 Vdc 2.9 Vdc 2.5 V 0A 8A 87% 0.1% 0.2% EXB30-48S2V5J 26.4 W 36-75 Vdc 3.8 Vdc 3.3 V 0A 8A 90% 0.1% 0.2% EXB30-48S3V3J 30 W 36-75 Vdc 5.65 Vdc 5V 0A 6A 92% 0.1% 0.2% EXB30-48S05J 30 W 36-75 Vdc 14.2 Vdc 12 V 0A 2.5 A 90% 0.1% 0.2% EXB30-48S12J 0.43 0.02 (10.90 0.5) 36-75 Vdc 20 W 0.138 0.02 (3.500.5) o0.040 0.002 (o1.02 0.05) 0.50 (12.70) 8 BOTTOM VIEW 7 3 PROTECTION Short circuit Continuous Overvoltage Non-latching clamp Thermal 6 4 5 1.90 (48.26) 125 C hot spot temperature with automatic recovery TELECOM SPECIFICATION Central office interface A 0.19 (4.83) 2.28 0.02 (57.91 0.5) ETS300-132-2, input voltage and current requirements ALL DIMENSIONS IN INCHES (mm) PIN CONNECTIONS General Tolerance 0.010 (0.25) (unless otherwise specified) PIN NUMBER FUNCTION 1 - Vin 2 No Pin EXTERNAL OUTPUT TRIMMING 3 Remote ON/OFF All models can be externally trimmed by using the method shown below. 4 + Vin CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. + Sense TRIM UP Trim - Sense TRIM DOWN RT1 or RT2 5 + Vout 6 + Sense 7 Trim 8 - Sense 9 - Vout 2.40 0.02 (60.96 0.5) 9 1.40 (35.56) 1 1.00 (25.40) STAND-OFFS 4 PLACES 0.70 (17.78) 0.20 (5.08) 0.02 (0.50) OPEN-FRAME HEIGHT 0.40 (10.16) 9 1.00 (25.40) 6 7 8 1.40 (35.56) 4 5 2.00 (50.80) Measured as per recommended set-up. di/dt = 0.1 A/s, Vin = 48 Vdc, Tc = 25 C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 lo max. to 0.5 lo max. The EXB30 meets level A and level B conducted emissions only with external components connected before the input pins to the converter. Full details are given in Application Note 108 on the website. Recommended input fusing is a 2 A HRC 200 V rated fuse. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Simulated source impedance of 12 H. 12 H inductor in series with +Vin. Start-up into resistive load. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http:// www.artesyn.com/powergroup/products.htm to find a suitable alternative. 3 (8,9) 16 W Notes 1 2 MODEL NUMBER Embedded Power for Business-Critical Continuity Rev.03.22.07 exb30s 4 of 4 Artesyn 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 13-15, Shing Wan Road Tai Wai, Shatin, N. T. Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770 For global contact, visit: www.artesyn.com technicalsupport@artesyn.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2007 Emerson Electric Co.