Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30 * Stainless steel housing, cylindrical * Diameter: M12, M18, M30 * Short or long versions * Sensing distance: 2 to 15 mm * Power supply: 10 to 40 VDC * Output: Transistor NPN/PNP, make or break switching * Protection: Short-circuit and reverse polarity * LED-indication for output ON * 2 m cable or plug M12 Product Description Ordering Key Proximity switch in housings ranging from M12 to M30. Short or long versions in stan- Type Housing diameter (mm) Rated operating dist. (mm) Output type Housing material Body style Plug dard stainless steel housing. Made after Euronorm EN 50 008. EI 1202 NPOSS-1 Type Selection DC Types, Cable and M12 Plug Housing Body diameter style Connection Rated operating dist. (Sn) Ordering no. Transistor NPN Make switching Ordering no. Transistor NPN Break switching Ordering no. Transistor PNP Make switching Ordering no. Transistor PNP Break switching M12 M12 M12 M12 M12 M12 M12 M12 Short Short Long Long Short Short Long Long Cable Plug Cable Plug Cable Plug Cable Plug 2 mm 1) 2 mm 1) 2 mm 1) 2 mm 1) 4 mm 2) 4 mm 2) 4 mm 2) 4 mm 2) EI 1202 NPOSS EI 1202 NPOSS-1 EI 1202 NPOSL EI 1202 NPOSL-1 EI 1204 NPOSS EI 1204 NPOSS-1 EI 1204 NPOSL EI 1204 NPOSL-1 EI 1202 NPCSS EI 1202 NPCSS-1 EI 1202 NPCSL EI 1202 NPCSL-1 EI 1204 NPCSS EI 1204 NPCSS-1 EI 1204 NPCSL EI 1204 NPCSL-1 EI 1202 PPOSS EI 1202 PPOSS-1 EI 1202 PPOSL EI 1202 PPOSL-1 EI 1204 PPOSS EI 1204 PPOSS-1 EI 1204 PPOSL EI 1204 PPOSL-1 EI 1202 PPCSS EI 1202 PPCSS-1 EI 1202 PPCSL EI 1202 PPCSL-1 EI 1204 PPCSS EI 1204 PPCSS-1 EI 1204 PPCSL EI 1204 PPCSL-1 M18 M18 M18 M18 M18 M18 M18 M18 Short Short Long Long Short Short Long Long Cable Plug Cable Plug Cable Plug Cable Plug 5 mm 1) 5 mm 1) 5 mm 1) 5 mm 1) 8 mm 2) 8 mm 2) 8 mm 2) 8 mm 2) EI 1805 NPOSS EI 1805 NPOSS-1 EI 1805 NPOSL EI 1805 NPOSL-1 EI 1808 NPOSS EI 1808 NPOSS-1 EI 1808 NPOSL EI 1808 NPOSL-1 EI 1805 NPCSS EI 1805 NPCSS-1 EI 1805 NPCSL EI 1805 NPCSL-1 EI 1808 NPCSS EI 1808 NPCSS-1 EI 1808 NPCSL EI 1808 NPCSL-1 EI 1805 PPOSS EI 1805 PPOSS-1 EI 1805 PPOSL EI 1805 PPOSL-1 EI 1808 PPOSS EI 1808 PPOSS-1 EI 1808 PPOSL EI 1808 PPOSL-1 EI 1805 PPCSS EI 1805 PPCSS-1 EI 1805 PPCSL EI 1805 PPCSL-1 EI 1808 PPCSS EI 1808 PPCSS-1 EI 1808 PPCSL EI 1808 PPCSL-1 M30 M30 M30 M30 M30 M30 M30 M30 Short Short Long Long Short Short Long Long Cable Plug Cable Plug Cable Plug Cable Plug 10 mm 1) 10 mm 1) 10 mm 1) 10 mm 1) 15 mm 2) 15 mm 2) 15 mm 2) 15 mm 2) EI 3010 NPOSS EI 3010 NPOSS-1 EI 3010 NPOSL EI 3010 NPOSL-1 EI 3015 NPOSS EI 3015 NPOSS-1 EI 3015 NPOSL EI 3015 NPOSL-1 EI 3010 NPCSS EI 3010 NPCSS-1 EI 3010 NPCSL EI 3010 NPCSL-1 EI 3015 NPCSS EI 3015 NPCSS-1 EI 3015 NPCSL EI 3015 NPCSL-1 EI 3010 PPOSS EI 3010 PPOSS-1 EI 3010 PPOSL EI 3010 PPOSL-1 EI 3015 PPOSS EI 3015 PPOSS-1 EI 3015 PPOSL EI 3015 PPOSL-1 EI 3010 PPCSS EI 3010 PPCSS-1 EI 3010 PPCSL EI 3010 PPCSL-1 EI 3015 PPCSS EI 3015 PPCSS-1 EI 3015 PPCSL EI 3015 PPCSL-1 1) 2) For flush mounting in metal For non-flush mounting in metal Make switching = Normally Open (NO) Break switching = Normally Closed (NC) Specifications are subject to change without notice (20.08.01) 1 EI, DC, M12, M18, M30 Specifications Rated operational volt. (Ue) (UB) Effective operating dist. (Sr) Usable operating dist. (S) Ambient temperature Operating Storage Degree of protection Housing material Body Front Back Connection Cable 12 to 36 VDC 10 to 40 VDC (ripple included) 10% Ripple Rated operational current (Ie) Continuous 200 mA Output ON: < 6.5 mA No-load supply current (Io) Output OFF: < 2.7 mA Voltage drop (Ud) 2 VDC at max. load Protection Reverse polarity, short-circuit, transients Transient voltage 700 V/0.5 J EMC Approved according to EN 50 080, EN 50 081 Power ON delay < 10 ms Frequency of operating EI 1202 800 Hz cycles (f) EI 1204 500 Hz EI 1805 500 Hz EI 1808 400 Hz EI 3010 300 Hz EI 3015 100 Hz Indication for output ON LED, yellow Assured operating dist. (Sa) 0 Sa 0.81 Sn Repeat accuracy (R) 5% Hysteresis (H) (Differential travel) 1 to 15% of sensing distance Plug Cables for plug (-1) Weight (cable excluded) Tightening torque Approvals CE-marking 0.9 x Sn Sr 1.1 x Sn 0.9 x Sr Su 1.1 x Sr -25 to +70C (-13 to +158F) -30 to +80C (-22 to +176F) IP 67 (Nema 1, 3, 4, 6, 13) Stainless steel (1.4301) Grey thermoplastic polyester Black polyester 2 m, 3 x 0.3 mm2, grey PVC,oil proof M12 x 1 CONH1A serie EI 12 10 g EI 1805 18 g EI 1808 20 g EI 3010 50 g EI 3015 70 g EI 12 7.5 Nm (x) 17.5 Nm (y) EI 18 27.5 Nm EI 30 100.0 Nm UL, CSA Yes Dimensions Type A B C O mm mm D mm E mm F G H I SW K L mm mm mm mm mm O mm O mm EI 1202 XPXSS EI 1202 XPXSL EI 1202 XPXSS-1 EI 1202 XPXSL-1 EI 1204 XPXSS EI 1204 XPXSL EI 1204 XPXSS-1 EI 1204 XPXSL-1 M12 x 1 x 30 M12 x 1 x 50 M12 x 1 x 30 M12 x 1 x 50 M12 x 1 x 30 M12 x 1 x 50 M12 x 1 x 30 M12 x 1 x 50 10.7 10.7 10.7 10.7 10.7 10.7 10.7 10.7 30 50 30 50 34 54 34 54 11 11 12.6 12.6 11 11 12.6 12.6 5.0 5.0 11.9 11.9 5.0 5.0 11.9 11.9 4 4 4 4 4 4 4 4 17 17 17 17 17 17 17 17 EI 1805 XPXSS EI 1805 XPXSL EI 1805 XPXSS-1 EI 1805 XPXSL-1 EI 1808 XPXSS EI 1808 XPXSL EI 1808 XPXSS-1 EI 1808 XPXSL-1 M18 x 1 x 30 M18 x 1 x 50 M18 x 1 x 30 M18 x 1 x 50 M18 x 1 x 30 M18 x 1 x 50 M18 x 1 x 30 M18 x 1 x 50 16.7 16.7 16.7 16.7 16.7 16.7 16.7 16.7 30 50 30 50 38 58 38 58 11.6 11.6 13.1 13.1 11.6 11.6 13.1 13.1 15.4 15.4 11.9 11.9 15.4 15.4 11.9 11.9 4 4 4 4 4 4 4 4 24 24 24 24 24 24 24 24 EI 3010 XPXSS EI 3010 XPXSL EI 3010 XPXSS-1 EI 3010 XPXSL-1 EI 3015 XPXSS EI 3015 XPXSL EI 3015 XPXSS-1 EI 3015 XPXSL-1 M30 x 1.5 x 30 M30 x 1.5 x 50 M30 x 1.5 x 30 M30 x 1.5 x 50 M30 x 1.5 x 30 M30 x 1.5 x 50 M30 x 1.5 x 30 M30 x 1.5 x 50 28 28 28 28 28 28 28 28 30 50 30 50 42 62 42 62 13.6 13.6 13.6 13.6 13.6 13.6 13.6 13.6 15.4 15.4 11.9 11.9 15.4 15.4 11.9 11.9 5 5 5 5 5 5 5 5 36 36 36 36 36 36 36 36 2 Specifications are subject to change without notice (20.08.01) EI, DC, M12, M18, M30 Dimensions (cont.) D E D C E B B C M 12 x 1 F F SW A SW LED Cable A LED Plug Wiring Diagrams 1 BN + 1 BN + 1 BN + 1 BN + 4 BK 2 WH 2 WH 4 BK 3 BU 3 BU - NPN - Make switching - NPN - Break switching 3 BU 3 BU PNP - Make switching PNP - Break switching Installation Hints To avoid interference from inductive voltage/ current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier A proximity switch should not serve as mechanical stop Any repetitive flexing of the cable should be avoided Incorrect Correct The cable should not be pulled Power Supplies Power supplies VDC: > SS 130/140. Power supplies with amplifier relays: > SV 190. Specifications are subject to change without notice (20.08.01) 3