LES DC/DC Series Data Sheet Description Features LES DC/DC converters provide up to 15 watts of output power in an industry-standard package and footprint. With a maximum case temperature of 100C, the LES is well suited for the most demanding telecom, networking, and industrial applications. The LES features 1500VDC isolation, short circuit protection, and six-sided shielding. The LES is available with optional enable and voltage trim pins. Please see the IAD Series for dual output applications. * * * * Industry Standard Package Industry Standard Pinout 100C Case Operation Short Circuit Protection * * * * 24V and 48V Inputs Input Pi Filter and 6-Sided Shielding Regulated Outputs 1500V Isolation Efficiency vs. Load (24V Input) 85 80 EFFICIENCY % 75 Technical Specifications Input 70 LES010YE-A 65 EFF. (18v) 60 EFF. (24v) 55 EFF. (36v) 50 Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple 18 - 36 VDC 36 - 75 VDC 50 mA 45 10 30 40 50 60 70 80 90 100 LOAD % Efficiency vs. Load (48V Input) Output 1% 0.2% Vout 0.5% Vout 10% Iout Rated 25% Iout 2% Vout 500 ms 10% Shutdown / Hiccup 110 - 150% 200% Iout Load Regulation Iout Min. - Iout Max., Vin Nom. Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range Short Circuit / Overcurrent Protection Current Limit Threshold Range, % of Iout Rated Short Circuit Current Max. (12Vout & 15Vout : 4.0A when Vout= 0.25V) 85 80 75 EFFICIENCY % Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated Ovp Trip Range Ovp Type 20 70 LES010ZE 65 LES015ZG 60 55 50 115 -140% Vout Nom. Second Control Loop 10 20 30 40 50 60 70 80 90 100 LOAD % General Notes Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF predictions may vary slightly from model to model. Specifications typically at 25C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. MTBF (Bellcore TR-NWT-000332) Safety REV. JUL 11, 2003 Page 1 of 3 10 ms Positive/Negative Logic 400 kHz 1500 VDC 500 VDC 0.02 ppm/C -40 To +100C -40 To +100C 95% 5 g, 10 - 55 Hz 2.5 X 106 hrs UL, cUL, TUV LES DC/DC Series Data Sheet Model Selection INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) LES008YD LES010YE LES015YG 24 24 24 18-36 18-36 18-36 0.6 0.8 1.1 2.5 3.3 5 3.00 3.00 3.00 75 100 100 77% 81% 84% LES015YH 24 18-36 1.3 12 1.25 120 85% LES015YJ 24 18-36 1.3 15 1.00 150 86% LES008ZD 48 36-75 0.35 2.5 3.00 75 77% LES010ZE 48 36-75 0.4 3.3 3.00 100 81% LES015ZG 48 36-75 0.6 5 3.00 100 83% LES020ZG-3N 48 40-60 0.63 5 4.00 100 84% LES015ZH 48 36-75 0.65 12 1.25 120 86% LES015ZJ 48 36-75 0.65 15 1.00 150 86% MODEL NOTES: RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. Mechanical Drawing Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 15.4 C/W 12.2 C/W 9.3 C/W 7.4 C/W 6.4 C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Pin 1 2 3 4 5 6 Tolerances Function +Vin -Vin no pin (Optional shutdown Pin) +Vout no pin (Optional Trim Pin) -Vout REV. JUL 11, 2003 Page 2 of 3 Inches: .XX 0.020 .XXX 0.010 (Millimeters) .X 0.5 .XX 0.25 Pin: 0.002 0.05 Case: + 0.04, - 0.00 + 1.0, - 0.00 (Dimensions as listed unless otherwise specified.) OPTIONS This page is offered as a reference. Consult factory for actual availability of options. When ordering equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the model number. Ordering option examples are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, QBS, QES, QLS, TES, TQD Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES, QLS Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES 8 All Leaded Models 9 All Leaded Models Pin Length and Heatsink Options 0.110" (2.8mm) Pin Length 0.150" (3.8mm) Pin Length REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF Standard Pin Length is 0.180" (4.6mm) 0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95" vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. JUL 11, 2003 Page 3 of 3