Oscilloscope Probes and
Probe Accessories
2
Teledyne LeCroy has a wide variety of world class probes and ampliers to compliment its
product line. From the ZS high impedance active probes to the WaveLink differential probing
system which offers bandwidths up to 25 GHz, Teledyne LeCroy probes and probe
accessories provide optimum mechanical connections for signal measurement.
Front Cover:
ZS Series High Impedence Active Probes
PROBE SELECTION
GUIDE
WaveJet Oscilloscopes
WaveSurfer 3000z
Oscilloscopes
WaveSurfer 510 Oscilloscopes
HDO4000A
High Definition Oscilloscopes
HDO6000A
High Definition Oscilloscopes
WaveRunner 8000
Oscilloscopes
HDO8000A High Definition
Oscilloscopes / MDA800A Motor
Drive Analyzers
HDO9000
High Definition Oscilloscopes
WavePro HD Oscilloscopes
WaveMaster/SDA/DDA/8 Zi-B
Oscilloscopes
LabMaster 10 Zi-A
Oscilloscopes
Active Voltage Rail Probes - p. 4 - 7
RP4030
✓✓✓✓✓✓✓✓
Active Voltage Probes - p. 8 - 11
ZS1000
✓✓✓✓✓✓✓✓✓
ZS1500
✓✓✓✓✓✓✓✓✓
ZS2500
✓✓✓✓
ZS4000
✓✓✓✓
Current Probes - p. 12 - 15
CP030
✓✓✓✓✓✓✓✓✓
CP030A
✓✓✓✓✓✓✓✓✓
CP031
✓✓✓✓✓✓✓✓✓
CP031A
✓✓✓✓✓✓✓✓✓
CP150
✓✓✓✓✓✓✓✓✓
CP500
✓✓✓✓✓✓✓✓✓
CA10
✓✓✓✓✓✓✓
Differential Probes - p. 16 - 25
ZD200
✓✓✓✓✓✓✓✓✓✓
ZD500
✓✓✓✓✓✓✓✓✓
ZD1000
✓✓✓✓✓✓✓✓✓✓
ZD1500
✓✓✓✓✓✓✓✓✓✓
AP033
✓✓✓✓✓✓✓✓✓
D410-A-PB2
✓✓✓✓
D420-A-PB2
✓✓✓✓
D400A-AT-PB2
D610-A-PB2
✓✓✓
D610-A-PL
D620-A-PB2
✓✓✓
D620-A-PL
D600A-AT-PB2
D600A-AT-PL
D830-PB2
✓✓✓
D830-PL
D1330-PL
D1605-A-PLA
D2005-A-PLA
D2505-A-2.92MM
High Voltage Differential Probes - p. 26 - 31
HVD3102A
✓✓✓✓✓✓✓✓✓
HVD3106A
✓✓✓✓✓✓✓✓✓
HVD3106A-6M
✓✓✓✓✓✓ ✓✓
HVD3206A
✓✓✓✓✓✓✓✓✓
HVD3206A-6M
✓✓✓✓✓✓✓✓✓
HVD3605A
✓✓✓✓✓✓✓✓✓
AP031
✓✓✓✓✓✓✓✓✓✓
Learn More: teledynelecroy.com/probes
3
WaveJet Oscilloscopes
WaveSurfer 3000z
Oscilloscopes
WaveSurfer 510 Oscilloscopes
HDO4000A
High Definition Oscilloscopes
HDO6000A
High Definition Oscilloscopes
WaveRunner 8000
Oscilloscopes
HDO8000A High Definition
Oscilloscopes / MDA800A Motor
Drive Analyzers
HDO9000
High Definition Oscilloscopes
WavePro HD Oscilloscopes
WaveMaster/SDA/DDA/8 Zi-B
Oscilloscopes
LabMaster 10 Zi-A
Oscilloscopes
Differential Amplifiers - p. 32 - 35
DXC200
✓✓✓✓✓✓✓✓✓
DA101
✓✓✓✓✓✓✓✓✓
DA1855A
✓✓✓✓✓✓✓✓✓
DA1855A-PR2
✓✓✓✓✓✓✓✓✓
DA1855A-PR2-RM
✓✓✓✓✓✓✓✓✓
DA1855A-RM
✓✓✓✓✓✓✓✓✓
DXC-5100
✓✓✓✓✓✓✓✓✓
DXC100A
✓✓✓✓✓✓✓✓✓
High Voltage Probes - p. 36 - 39
HVP120
✓✓✓✓✓✓✓✓✓✓
PPE4KV
✓✓✓✓✓✓✓✓✓✓
PPE5KV
✓✓✓✓✓✓✓✓✓✓
PPE6KV
✓✓✓✓✓✓✓✓✓✓
High Voltage Fiber Optically-isolated Probes - p. 40 - 43
HVFO103
✓✓✓✓✓✓✓✓✓
Optical-To-Electrical Converters - p. 44 - 47
OE6250G-M
OE695G
OE425
✓✓✓✓
OE455
✓✓✓✓
OE525
OE555
Passive Probes - p. 48 - 51
PP006C
PP016
PP019
PP020
PP021
PP022
PP023
✓✓✓
PP024
PP025
PP026
Probe Adapters - p. 52 - 53
CA10
✓✓✓✓ ✓✓
TPA10
✓✓✓✓✓✓ ✓✓
Transmission Line Probes - p. 54 - 55
PP066
✓✓✓
Learn More: teledynelecroy.com/probes
4
ACTIVE VOLTAGE RAIL PROBE
5
The RP4030 is designed specically to probe a 50Ω DC power/voltage rail.
The probe has large built-in offset, low attenuation (noise), and high DC input
impedance. Built-in offset and low attenuation permit the power/voltage rail
to be offset in the oscilloscope by its mean DC voltage with high oscilloscope
gain (sensitivity) to achieve a noise-free view of small signal variations. The
high DC input impedance eliminates loading of the DC rail.
ACTIVE VOLTAGE RAIL PROBE
Teledyne LeCroy
Active Voltage Rail Probe
Model Numbers:
RP4030
Opposite page:
Active Voltage Rail Probes RP4030 working with
an HDO8000A High Denition Oscilloscope
6
ACTIVE VOLTAGE RAIL PROBE
Teledyne LeCroy
Active Voltage Rail Probe
Model Number:
RP4030
Key Features
4 GHz Bandwidth
±30V Offset Capability
±800mV Dynamic Range
50 kΩ DC Input Impedance
1.2x Attenuation (Low Additive
Noise, ~5%)
MCX terminated cable with wide
variety of connections:
Solder-in (4 GHz)
Coaxial Cable to
U.FL receptacle (3 GHz)
MCX PCB Mount (4 GHz)
Browser (350 MHz)
ProBus Interface
Large Offset Range
Permits the DC signal to be displayed in the vertical center of the oscilloscope
grid with a high-sensitivity gain setting.
Low Attenuation and Noise
The probe attenuation is a nominal 1.2x coupled to the oscilloscope at DC50 Ω.
This keeps additive noise to a minimum, and makes it exceptionally useful with
High Denition oscilloscopes for lowest noise at highest sensitivity gain settings.
High DC Input Impedance
50 kΩ input impedance at DC effectively eliminates probe loading on the DC
power/voltage rail and provides for more accurate measurements and signal
delity.
7
ACTIVE VOLTAGE RAIL PROBE
Product Description Product Code
Power/Voltage Rail Probe
4 GHz, 1.2x, ±30V offset, ±800mV dynamic range RP4030
Includes Qty. 1 ProBus compatible probe offset amplier with 50 kΩ DC
input impedance and SMA input connection for provided 0.9m SMA to
MCX extension cable. Also supplied are Qty. 3 MCX solder-in leads, Qty.
3 MCX PCB Mounts, Qty. 3 MCX to U.FL coaxial cables, Qty. 5 U.FL PCB
Mounts, Qty. 1 MCX to SMA adapter, and soft carrying case. Browser tip
sold separately.
350 MHz Browser Tip Accessory RP4000-BROWSER
Includes 0 Ω (1x), 450 Ω (10x) and 950 Ω (20x) tips.
Accessories and Consumables
Qty. 3 MCX 4 GHz solder-in leads RP4000-MCX-LEAD-SI
Qty. 10 MCX PCB mount receptacle RP4000-MCX-PCBMOUNT
Qty. 3 MCX to U.FL 3 GHz ultra-mini
coax cable
RP4000-MCX-CABLE-UFL
Qty. 10 U.FL PCB mount receptacles RP4000-UFL-PCBMOUNT
Specications
Electrical Characteristics
Bandwidth 4 GHz (guaranteed, MCX receptacle)
4 GHz (typical, solder-in lead)
3 GHz (typical, U.FL cable +
receptacle)
350 MHz (typical, browser)
Rise Time (10-90%) 110 ps (typical, MCX receptacle or
solder-in lead)
Input Capacitance 0.1 uF (in series with 50Ω)
DC Input Resistance 50 kΩ
Offset Range ±30V
Attenuation 1.2x
Input Dynamic Range ±800 mV
Non-destruct Voltage ±50V
Noise ~5% additive to oscilloscope noise
Oscilloscope Termination DC 50Ω
Environmental
Operating Temperature Range 0 to 50 ºC
Non-operating Temperature Range -40 to +70 ºC
Humidity 5% to 80% RH (non-condensing) up
to 30 ºC, decreasing linearly to to 45%
RH at 50 ºC
Operating Altitude 3000 meters maximum
Physical
RP4030 Probe: 38.1 mm W x 15.9mm H x
73mm L (1-1/2” x 5/8” x 2-7/8”)
SMA to MCX Cable: 914mm L (36”)
MCX to Solder-in Lead: 191mm (7-
1/2”) usable length
MCX to U.FL Plug Coaxial Cable:
102mm (4”) usable length
RP4000-BROWSER 11.9mm W x 9.5mm H x 38mm L
(15/32” x 3/8” x 1-1/2”)
SMA to SMA Cable: 1m (39-3/8”)
usable length
Other
Oscilloscope Interface Teledyne LeCroy ProBus
Software Requirements Teledyne LeCroy MAUI 8.2.1.1 or
higher
Weight 119 g (0.26 lb)
Ordering Information
4 GHz of Bandwidth
Provides maximum bandwidth for probing near the CPU,
and the perfect match with the 4 GHz, 10 bit HDO9404
when making power integrity measurements.
Wide Assortment of
Tips and Leads
The RP4030 is supplied standard with solder-in and coaxial
cables with MCX and U.FL PCB receptacle mounts. A
browser tip is optionally available. Additional receptacles or
leads may be purchased as accessories and left connected
in circuit for easy connection of different signals during
different test or validation stages.
8
ACTIVE VOLTAGE PROBES
8
9
ACTIVE VOLTAGE PROBES
Teledyne LeCroy
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
Opposite page:
ZS Series High Impedance Active Probe
Engineers must commonly probe high-frequency signals with high
signal delity. Typical passive probes with high input R and C provide good
response at lower frequencies, but inappropriately load the circuit and
distort signals at higher frequencies. Active voltage probes feature both
high input R and low input C to reduce circuit loading across the entire
probe/oscilloscope bandwidth. With low circuit loading and a form factor
that allows probing in conned areas, the active voltage probe becomes
the everyday probe for all different types of signals and connection points.
10
ZS SERIES ACTIVE PROBES
Teledyne LeCroy
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
The ZS Series probes are high impedance, low capacitance active probes that
maintain high signal delity through 4 GHz. A small form factor and a wide variety
of accessories ensures the ZS probe meets every difcult probing challenge.
Engineers must commonly probe high frequency signals with high signal delity.
Typical passive probes with high input R and C provide good response at lower
frequencies but inappropriately load the circuit and distort signals at higher
frequencies. The ZS Series features both high input R (1 MΩ) and low input C
(0.6 pF and 0.9 pF) to reduce circuit loading across the entire probe/oscilloscope
bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes. The ZS1500 is
ideal for 1 GHz oscilloscopes, the ZS2500 is ideal for 2 GHz oscilloscopes, and the
ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
PK-ZS-009
Copper Tape
PACC-PT005
Bent Tip
PK-ZS-024
2.54 mm PCB
Adapter
PACC-PT003
IC Tip
PK-ZS-017
Pogo Tip
PK-ZS-001
Probe Tip - Standard
PK-ZS-014
Y-Lead
Adapter
PK-ZS-010
Channel ID
Colored Clips
PK-ZS-019
Freehand Probe Holder
PK-ZS-023
Straight Pin
Lead - 13cm
PK-ZS-022
Straight Pin
Lead - 7cm
PACC-LD004
Right Angle
Pin Lead - 10cm
PK-ZS-007B
Microclip Sprung
Hook, Black
PK-ZS-007R
Microclip Sprung
Hook, Red
PK-ZF-025
QFPIC Clip Green -
Short
PK-ZF-025
QFPIC Clip Yellow -
Short
PACC-LD003
Right Angle
Pin Lead - 5cm
PK-ZS-006
Right Angle Socket
PK-ZS-021
Ground Blade -
Narrow
PK-ZS-015
Ground Blade - Wide
PK-ZS-016
Offset Ground
(Z Lead)
PK-ZS-020
Pogo Ground Lead
PK-ZS-018
2.54 mm Square
Pin Adapter
ZS4000
11
ZS SERIES ACTIVE PROBES
PK-ZS-009
Copper Tape
PACC-PT005
Bent Tip
PACC-PT003
IC Tip
PK-ZS-005
Y-Lead
Adapter
PK-ZS-010
Channel ID
Colored Clips
PK-ZS-004
Single Lead -
Long
PK-ZS-003
Single Lead -
Short
PACC-LD004
Right Angle
Lead - Long
PK-ZS-007B
Microclip Sprung
Hook, Black
PK-ZS-007R
Microclip Sprung
Hook, Red
PACC-LD003
Right Angle
Pin Lead - 5cm
PK-ZS-006
Right Angle Socket
PK-ZS-008
Ground Blade - Narrow
PK-ZS-011
Ground Blade - Wide
PK-ZS-002
Offset Ground
PACC-CD008
Pogo Ground Lead
PK-ZS-012
2.54 mm Square Pin
Adapter
PK-ZS-001
Probe Tip - Standard
Qty: 3
PK-ZS-013
Pogo Tip
PACC-MS005
Freehand Probe Holderk
ZS1000
ZS1500
ZS2500
Specications ZS1000 ZS1500 ZS2500 ZS4000
Electrical Characteristics
Probe Bandwidth 1 GHz 1.5 GHz 2.5 GHz 4 GHz
Input Capacitance 0.9 pF 0.6 pF
DC Input Resistance 1 MΩ
Probe Offset Range N/A ±12 V
Attenuation ÷10
Input Dynamic Range ±8 V
Non-destruct Voltage 20 V
General Characteristics
Cable Length 1.3 m
Ordering Information
Product Description Product Code
4 GHz, 0.6 pF, 1 MΩ
High Impedance Active Probe
ZS4000
2.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe
ZS2500
1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe
ZS1500
1 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe
ZS1000
Set of 4 ZS2500, 2.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes
ZS2500-QUADPAK
Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes
ZS1500-QUADPAK
Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes
ZS1000-QUADPAK
Standard Accessory/Quantity
Accessory Description Replacement
Part Number
ZS1000
ZS1500
ZS2500 ZS4000
2.54 mm PCB Adaptor PK-ZS-024 5
2.54mm Square Pin Adapter PK-ZS-012 1
2.54mm Square Pin Adaptor PK-ZS-018 1
IC Tip PACC-PT003 1 1
Bent Tip PACC-PT005 1 1
Channel ID Clips
(Set of 4 colors) PK-ZS-010 4 1
Copper Tape Pad PK-ZS-009 2 2
Freehand Probe Holder PK-ZS-019 1
Freehand Probe Holder PACC-MS005 1
Ground Blade – Narrow PK-ZS-008 1
Ground Blade – Wide PK-ZS-011 1
Ground Blade, Narrow PK-ZS-021 1
Ground Blade, Wide PK-ZS-015 2
Micro-Grabber Pair PK-ZS-007R and
PK-ZS-007B 1 2
Offset Ground PK-ZS-016 2
Accessory Description Replacement
Part Number
ZS1000
ZS1500
ZS2500 ZS4000
Offset Ground – Z Lead PK-ZS-002 1
Pogo Ground Lead PK-ZS-020 1
Pogo Ground Lead PACC-CD008 1
Pogo Tip PK-ZS-017 3
Pogo Tip PK-ZS-013 1
Probe Tip – Standard PK-ZS-001 3 3
QFPIC Clips (set of 2) PK-ZS-025 1
Right Angle Lead – Long PACC-LD004 1 1
Right Angle Lead – Short PACC-LD003 1 1
Right Angle Socket PK-ZS-006 1 1
Straight Pin Lead – Long PK-ZS-023 1
Straight Pin Lead – Long PK-ZS-004 1
Straight Pin Lead – Short PK-ZS-022 1
Straight Pin Lead – Short PK-ZS-003 1
Y Lead Adapter PK-ZS-005 1
Y Lead Adaptor PK-ZS-014 1
12
CURRENT PROBES
13
CURRENT PROBES
Opposite page:
CP031, 30A, 100 MHz Current Probe.
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
CP030
CP030A
CP031
CP031A
CP150
CP500
DCS025
CA10
Teledyne LeCroy current probes do not require the breaking of a
circuit or the insertion of a shunt to make accurate and reliable
current measurements. Based on a combination of Hall effect and
transformer technology, Teledyne LeCroy current probes are ideal for
making accurate AC, DC, and impulse current measurements.
Wide Range of Applications
Teledyne LeCroy current probes are available in a variety of models for a
wide range of applications. The full range of Teledyne LeCroy current probes
includes models with bandwidths up to 100 MHz, peak currents up to
700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often
used in applications such as the design and test of switching power supplies,
motor drives, electric vehicles, and uninterruptible power supplies.
High Sensitivity
The CP030A and CP031A provide a high sensitivity of 1 mA/div. This
allows for more precise low current measurements on Teledyne LeCroy
oscilloscopes. When used with HDO high denition oscilloscopes with
HD4096 technology, users will obtain highly accurate, low current waveforms
with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy
ProBus® connection and require no additional hardware. Along with providing
power, the ProBus connection allows the current probe and oscilloscope to
communicate, resulting in current waveforms automatically displayed on
screen in Amps, and calculated power traces scaled correctly in Watts. This
full integration also allows for Degauss and Autozero functions to be done
directly from the oscilloscope’s user interface.
Deskew Calibration Source
The DCS015 deskew calibration source has both voltage and current time-
aligned signals, which enables the precise deskew of voltage and current
probes. Most voltage probes along with the CP030, CP030A, CP031, and
CP031A are compatible with the DSC025.
14
CURRENT PROBES
DCS025
Precise deskew of voltage and
current probes.
Compatible with the CP030, CP030A,
CP031, CP031A, AP015, CP150, and
CP500
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
CP030
CP030A
CP031
CP031A
CP150
CP500
DCS025
CA10
Key Features
ProBus active probe interface withautomatic scaling in A/div
Autozero and degauss capabilities built into instrument’s user interface
Wide range of input currents and bandwidth capabilities
CP030
30 Arms continuous current
50 Apeak current
50 MHz bandwidth
CP030A
30 Arms continuous current
50 Apeak current
50 MHz bandwidth
1 mA/div sensitivity
CP031
30 Arms continuous current
50 Apeak current
100 MHz bandwidth
CP031A
30 Arms continuous current
50 Apeak current
100 MHz bandwidth
1 mA/div sensitivity
CP150
150 Arms continuous current
500 Apeak current
10 MHz bandwidth
CP500
500 Arms continuous current
700 Apeak current
2 MHz bandwidth
15
CURRENT PROBES
Ordering Information
CA10 Current Sensor Adapter
The CA10 enables a third-party current measurement device to operate like a Teledyne
LeCroy probe. The CA10 is programmable and customizable to work with third-party
current measurement devices that output voltage or current signals proportional to
measured current. (See page 52 for more information and specications).
Specications CP030
(CP030-3M)
CP030A CP031 CP031A CP150
(CP150-6M)
CP500
Electrical Characteristics*
Max. Continuous
Input Current 30 Arms 150 Arms 500 Arms
Bandwidth 50 MHz
(10 MHz) 100 MHz 10 MHz
(5 MHz) 2 MHz
Rise Time (typical) ≤ 7 ns
(≤ 35 ns) 3.5 ns ≤ 35 ns
(≤ 70 ns) 175 ns
Max. Peak Current 50 Apeak (non-continuous) 300 Apeak (non-continuous);
500 Apeak ≤ 30 μs
700 Apeak
(non-continuous)
Output Voltage 0.1 V/A 0.1 V/A & 1 V/A 0.1 V/A 0.1 V/A & 1 V/A 0.01 V/A
Max Continuous Input Current
at 1 V/A (100mA/div or less) 5 A 5 A
Offset Range at 1V/A
(100mA/div or less) ±5 A ±5 A
Minimum Sensitivity 10 mA/div 1 mA/div 10 mA/div 1 mA/div 100 mA/div
Low-Frequency Accuracy 1%
AC Noise at 20 MHz BWL 2.5 mA 150 µA 2.5 mA 150 µA 6.0 mA 8.0 mA
Coupling AC, DC, GND
General Characteristics
Cable Length 1.5 m
(3 m) 1.5 m 2 m
(6 m) 6 m
Weight 240 g
(290 g) 260 g 240 g 260 g 500 g
(600 g) 630 g
Max. Conductor Size
(Diameter) 5 mm 20 mm
Interface ProBus, 1 MΩ only
Usage Environment Indoor
Operating Temperature 0˚ C to 40˚ C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated
Wire Voltage 300 V CAT I 600 V CAT II, 300 V CAT III
* Electrical Characteristics Guaranteed at 23 °C ±3 °C
CP03x, CP150, and CP500 probes (and long cable versions of these) are compatible with any Teledyne LeCroy oscilloscope with a ProBus interface running
rmware version 4.3.1.1 or greater.
CP03xA probes are compatible with most Teledyne LeCroy oscilloscopes with a ProBus interface running X-Stream™ rmware version 7.8.x.x or later.
Product Description Product Code
ProBus Current Sensor Adapter CA10
Set of 4 CA10, ProBus Current Sensor Adapters CA10-QUADPAK
30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable CP030
30A; 10 MHz Current Probe - AC/DC, 30 Arms; 50 A Peak Pulse, 3 meter cable (not EMC compliant) CP030-3M
30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable CP030A
30 A; 100 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable CP031
30 A; 100 MHz High Sensitivity Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable CP031A
150 A; 10 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse, 2 meter cable CP150
150 A; 5 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse, 6 meter cable (not EMC compliant) CP150-6M
500 A; 2 MHz Current Probe – AC/DC; 500 Arms; 700 A Peak Pulse, 6 meter cable CP500
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500 DCS025
16
16
DIFFERENTIAL PROBES
17
DIFFERENTIAL PROBES
Opposite page:
WaveLink® High Bandwidth Differential Probing System
(13 GHz – 25 GHz)
Differential active probes are like two probes in one. Instead of measuring
a test point in relation to a ground point (like single-ended active probes),
differential probes measure the difference in voltage of a test point in
relation to another test point.
Teledyne LeCroy
Differential Probe
Model Numbers:
1.5 GHz
ZD200
ZD500
ZD1000
ZD1500
AP033
4 GHz - 6 GHz
D410-A-PB2
D420-A-PB2
D400A-AT-PB2
D610-A-PB2
D610-A-PL
D620-A-PB2
D620-A-PL
D600A-AT-PB2
D600A-AT-PL
8 GHz - 13 GHz
D830-PB2
D830-PL
D1330-PL
13 GHz - 25 GHz
D1605-A-PLA
D2005-A-PLA
D2505-A-2.92MM
18
1.5 GHz DIFFERENTIAL PROBES
The ZD Series probes provide wide dynamic range, excellent noise and loading
performance and an extensive set of probe tips, leads, and ground accessories
to handle a wide range of probing scenarios. The low 1 pF capacitance means
this probe is ideal for all frequencies. The ZD Series differential probes provide full
system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower.
Fully Integrated
With the ProBus interface, the ZD500, 1000, and 1500 become an integral part
of the oscilloscope. All probe gain and offset controls are transparent to the user,
making it easier to probe the circuit without concern for which gain setting to
choose. When used with a Teledyne LeCroy digital oscilloscope, no external power
supply is required.
Wide Dynamic Range
The ZD500, 1000, 1500 probes provide transparent probe attenuation so signals are
always optimized for the display. The differential range is 18 Vp-p with a differential
offset of ±8V and common mode range of ±10 V, making these probes versatile for
every probing application.
Wide Applications
The wide dynamic range of 16 Vp-p and offset range of ±8V suit this probe to a wide
range of applications and signal types. The ZD differential probes are ideally suited
for Automotive, Serial Data, power, and general purpose use.
Specications ZD200 ZD500 ZD1000 ZD1500
Electrical Characteristics
Bandwidth (Warranted) 200 MHz 500 MHz 1000 MHz 1500 MHz
Bandwidth (Typical) -650 MHz 1200 MHz 1700 MHz
Risetime 10–90% (Typical) 1.75 ns 650 ps 375 ps 270 ps
Risetime 20–80% (Typical) -500 ps 280 ps 200 ps
LF Attenuation Accuracy (Warranted) 1% 2%
Zero Offset (Typical)
(within 15 minutes after autozero) -5 mV
System Noise (Typical) -1.3 mVrms 1.75 mVrms
Probe Noise Density (Typical) 3 mVrms 38 nV/rt (Hz)
Input Differential Range (Nominal) ± 20 V ±8 V (16 Vp-p)
Differential Offset Range (Nominal) -±18 V
Offset Gain Accuracy (Typical) -2%
Common Mode Range (Nominal) ± 60 V ±10 V
Maximum Non-destruct Voltage
(Nominal) -30 V
CMRR (Typical) 80 dB @ 60 Hz
50 dB@10 MHz 60 dB 50/60 Hz
30 dB 20 MHz
25 dB 500 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB @ 1000 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB @ 1500 MHz
DC Input Resistance (Nominal) 250 kΩ (Common Mode)
1 MΩ (Differential Mode) 50 kΩ (Common Mode)
120 kΩ (Differential Mode)
Differential Input Capacitance
(Typical) 3.5 pF < 1.0 pF
Teledyne LeCroy
1.5 GHz
Differential Probe
Model Numbers:
ZD200
ZD500
ZD1000
ZD1500
AP033
19
1.5 GHz DIFFERENTIAL PROBES
AP033
High bandwidth, excellent common-mode rejection ratio
(CMRR) and low noise make these active differential
probes ideal for applications such as disk drive design
and failure analysis, as well as wireless and data
communication design.
Ordering Information
Product Description Product Code
500 MHz Differential Probe AP033
Specications
Bandwidth 500 MHz
Gain x10, x1, ÷10 (÷100 with
plug-on ÷10 attenuator)
DC Accuracy 1% in x1 without
external attenuator
Input Resistance 1 MΩ each input to ground
2 MΩ differential between inputs
Differential Mode Range ±400 mV (x1)
±40 mV (x10)
±4 V (÷10)
±40 V (÷100)
Offset Range ±400 mV (x1, x10)
±4 V (±10)
±40 V (±100)
Common-Mode Range ±42 V peak (±10)
+4.2 V peak (±100)
CMRR 70 Hz 10,000:1 (80 dB)
100 kHz 10,000:1 (80 dB)
1 MHz 1000:1 (60 dB)
10 MHz 100:1 (40 dB)
250 MHz 5:1 (14 dB)
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
PACC-MS001
Hands Free Probe Holder
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-ZD004
Tip Saver
Qty: 2
PACC-ZD005
Swivel Tip Adapter
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PCF200
Probe Calibration Fixture
ZD1500 / ZD1000 / ZD500 Probe
Ordering Information
Product Description Product Code
200 MHz, 3.5 pF, 1 MΩ Active Differential Probe ZD200
500 MHz, 1.0 pF Active Differential Probe, ±8 V ZD500
1 GHz, 1.0 pF Active Differential Probe, ±8 V ZD1000
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V ZD1500
19
20
4 GHz - 6 GHz DIFFERENTIAL PROBES
Teledyne LeCroy’s WaveLink 4-6 GHz Differential Probes are a general purpose
probing solution with high-input dynamic range and offset range capability. The
range of capabilities is ideal for a variety of high-speed DDR signals where high
dynamic range and large offset requirements are common.
Teledyne LeCroy
4 GHz - 6 GHz
Differential Probe
Model Numbers:
D410-A-PB2
D420-A-PB2
D400A-AT-PB2
D610-A-PB2
D610-A-PL
D620-A-PB2
D620-A-PL
D600A-AT-PB2
D600A-AT-PL
Key Features
4 GHz or 6 GHz models
Up to 5 Vpk-pk dynamic range with low noise
±3 V offset range
Ideal for DDR2, LPDDR2, DDR3
Innovative QuickLink architecture
Wide variety of tips and leads
Solder-In Lead
QuickLink Solder-In Lead
Positioner (Browser) Tip
Adjustable (Browser) Tip
Low loading and high impedance for minimal signal disturbance
Deluxe soft carrying case
Quick Connect Lead
Square Pin Lead
Hi-Temp Solder-In Lead
21
4 GHz - 6 GHz DIFFERENTIAL PROBES
D610-A-PB2,
D610-A-PL D620-A-PB2,
D620-A-PL D410-A-PB2 D420-A-PB2 D600A-AT-PB2,
D600A-AT-PL D400A-AT-PB2
Bandwidth*
(Probe only, guaranteed)
(System bandwidth, typical)
Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
6 GHz
Dx10-HiTemp
5 GHz
Dx10-QC Tip
4 GHz
Dx10-SP Tip
3 GHz
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
6 GHz
Dx20-HiTemp
5 GHz
Dx20-QC Tip
4 GHz
Dx20-SP Tip
3 GHz
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp, Dx10-QC
and Dx10-PT Tips
4 GHz
Dx10-SP Tip
3 GHz
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp, Dx20-QC
and Dx20-PT Tips
4 GHz
Dx20-SP Tip
3 GHz
6 GHz 4 GHz
Rise Time* (10–90%) Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
75 ps (typical)
Dx10-HiTemp
90 ps (typical)
Dx10-QC Tip
122.5 ps (typical)
Dx10-SP Tip
150 ps (typical)
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
75 ps (typical)
Dx20-HiTemp
90 ps (typical)
Dx20-QC Tip
122.5 ps (typical)
Dx20-SP Tip
150 ps (typical)
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp, Dx10-QC
and Dx10-PT Tips
112 ps (typical)
Dx10-QC Tip
122.5 ps (typical)
Dx10-SP Tip
150 ps (typical)
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp, Dx20-QC
and Dx20-PT Tips
112 ps (typical)
Dx20-QC Tip
122.5 ps (typical)
Dx20-SP Tip
150 ps (typical)
<75 ps (typical) <112 ps (typical)
Rise Time* (20–80%) Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
56 ps (typical)
Dx10-HiTemp
67.5 ps (typical)
Dx10-QC Tip
92 ps (typical)
Dx10-SP Tip
113 ps (typical)
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
56 ps (typical)
Dx20-HiTemp
67.5 ps (typical)
Dx20-QC Tip
92 ps (typical)
Dx20-SP Tip
113 ps (typical)
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp, Dx10-QC
and Dx10-PT Tips
84 ps (typical)
Dx10-QC Tip
92 ps (typical)
Dx10-SP Tip
113 ps (typical)
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp, Dx20-QC
and Dx20-PT Tips
84 ps (typical)
Dx20-QC Tip
92 ps (typical)
Dx20-SP Tip
113 ps (typical)
56 ps (typical) 84 ps (typical)
Noise (System) <36 nV/√Hz
(2.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<61 nV/√Hz
(4.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<36 nV/√Hz
(2.3 mVrms) (typical)
Referred to input,
4 GHz bandwidth
<67 nV/√Hz
(4.3 mVrms) (typical)
Referred to input,
4 GHz bandwidth
<74 nV/√Hz
(5.8 mVrms) (typical)
Referred to input,
6 GHz bandwidth
<74 nV/√Hz
(4.7 mVrms) (typical)
Referred to input,
4 GHz bandwidth
Input
Input Dynamic Range
(Nominal) 2.5Vpk-pk, ±1.25V 5Vpk-pk, ±2.5V 2.5Vpk-pk, ±1.25V 5Vpk-pk, ±2.5V 4.8Vpk-pk, ±2.4V
Input Common Mode Voltage
Range (Nominal) ±4 V ±2.4 Vmax
Input Offset Voltage Range ±3 V Differential (nominal) n/a
Non-destructive
Input Range (Nominal) ±20 V ±18 V
Attenuation 1.7X / 1.0X (nominal) 3.2X / 1.9X (nominal) 1.7X / 1.0X (nominal) 3.2X / 1.9X (nominal) 2.5X
DC Input Resistance
(Nominal)
200 kΩ Differential
50 kΩ Common Mode
4 kΩ Differential
1 kΩ Common Mode
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth
Through entire frequency range
Product Description Product Code
Complete Differential Probes
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
D410-A-PB2
4 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
D410-A-PL
4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
D420-A-PB2
4 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
D420-A-PL
6 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
D610-A-PB2
6 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
D610-A-PL
6 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
D620-A-PB2
6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
D620-A-PL
4 GHz ProBus2 Differential Probe with Adjustable Tip D400A-AT-PB2
6 GHz ProBus2 Differential Probe with Adjustable Tip D600A-AT-PB2
6 GHz ProLink Differential Probe with Adjustable Tip D600A-AT-PL
Positioner Tip (Browser) Kits
WaveLink Dx10-PT Adjustable Positioner Tip Kit.
For use with Dx10 ampliers.
Dx10-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit.
For use with Dx20 ampliers.
Dx20-PT-KIT
QuickLink Solder-In Tip Set
QuickLink Solder-In starter pack for use with Dx10 amplier.
Includes one QuickLink adapter and three QL-SI tips.
Dx10-QL-3SI
QuickLink Solder-In starter pack for use with Dx20 amplier.
Includes one QuickLink adapter and three QL-SI tips.
Dx20-QL-3SI
Product Description Product Code
Accessories
Probe Deskew and Calibration Test Fixture TF-DSQ
Calibration Options
NIST Calibration for D410-A. Includes test data. D410-A-CCNIST
NIST Calibration for D420-A. Includes test data. D420-A-CCNIST
NIST Calibration for D610-A. Includes test data. D610-A-CCNIST
NIST Calibration for D620-A. Includes test data. D620-A-CCNIST
NIST Calibration for D400A-AT. Includes test data. D400A-AT-CCNIST
NIST Calibration for D600A-AT. Includes test data. D600A-AT-CCNIST
Replacement Parts
Single replacement QuickLink Solder-In Tip QL-SI-1Pack
9-pack of replacement QuickLink Solder-In Tip QL-SI-9Pack
Replacement Dx10-SI 4 & 6 GHz Solder-In Lead with
Qty. 5 Spare Resistors.
Dx10-SI
Replacement Dx20-SI 4 & 6 GHz Solder-In Lead with
Qty. 5 Spare Resistors.
Dx20-SI
Replacement Dx10-QC 4 & 6 GHz Quick Connect Lead Dx10-QC
Replacement Dx20-QC 4 & 6 GHz Quick Connect Lead Dx20-QC
Replacement Dx10-SP 4 & 6 GHz Square Pin Lead Dx10-SP
Replacement Dx20-SP 4 & 6 GHz Square Pin Lead Dx20-SP
Replacement SI Resistor Kit for Dx10/Dx20 - Kit of 20 PKxx0-SI
Replacement QC Resistor Kit for Dx10/Dx20 - 2 kits of 20 PKxx0-QC
Qty. 4 Replacement Pogo Pin Tips and Qty. 2
Replacement Sockets for Dx10-PT and
Dx20-PT Adjustable Positioner Tips.
Dxx0-PT-TIPS
Replacement Probe Tip Holder Kit PK600ST-3
Replacement Platform/Cable Assembly Mounting Kit PK600ST-4
Quantity 1 Package of Black Adhesive Pads (10/pkg) and
Quantity 1 Package of White Adhesive Pads (10/pkg)
Dxx0-PT-TAPE
Quantity 1 Package of Adhesive Probe Connection Guides
(200 individual guides/package)
Dxx0-PT-GUIDES
22
8 GHz - 13 GHz DIFFERENTIAL PROBES
Key Features
Choice of 8 or 13 GHz bandwidth models
3.5 Vpk-pk dynamic range
±4 V offset range
Ideal for DDR3, DDR4, LPDDR3
Innovative QuickLink architecture
Wide variety of tips and leads
– Solder-In Lead
– QuickLink Solder-In Lead
– Positioner (Browser) Tip
– SMA/SMP Lead
– Square Pin Lead
– Hi-Temp Solder-In Lead
Low loading and high impedance for minimal signal disturbance
Deluxe soft carrying case
SMA/SMP lead set accessory does not require purchase of a different amplier
Teledyne LeCroy
8 GHz - 13 GHz
Differential Probe
Model Numbers:
D830-PB2
D830-PL
D1330-PL
The WaveLink Differential Probe Series is a 8-13 GHz bandwidth active differential
probe series with high input dynamic range, a large offset capability, and a wide
variety of tips and leads available for different applications.
23
8 GHz - 13 GHz DIFFERENTIAL PROBES 8 GHz - 13 GHz DIFFERENTIAL PROBES
D830-PB2, D830-PL D1330-PL
Bandwidth*
(Probe only, guaranteed)
(System bandwidth, typical)
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
8 GHz
Dxx30-SP Tip
3 GHz
Dxx30-SI and Dxx30-SMA-SMP Tips
13 GHz
Dxx30-PT and Dxx30-HiTemp Tips
10 GHz
Dxx30-QL-SI Tip
8 GHz
Dxx30-SP Tip
3 GHz
Rise Time* (10–90%) Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
50 ps (typical)
Dxx30-SP Tip
132 ps (typical)
Dxx30-SI and Dxx30-SMA-SMP Tips
35 ps (typical)
Dxx30-PT and Dxx30-HiTemp Tips
40 ps (typical)
Dxx30-QL-SI Tip
50 ps (typical)
Dxx30-SP Tip
132 ps (typical)
Rise Time* (20–80%) Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
37.5 ps (typical)
Dxx30-SP Tip
100 ps (typical)
Dxx30-SI and Dxx30-SMA-SMP Tips
26 ps (typical)
Dxx30-PT and Dxx30-HiTemp Tips
30 ps (typical)
Dxx30-QL-SI Tip
37.5 ps (typical)
Dxx30-SP Tip
100 ps (typical)
Noise (Probe) <48 nV/Hz (4.3 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<48 nV/Hz (5.5 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
Noise (System) <52 nV/Hz (4.6 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<52nV/Hz (5.9 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
Input
Input Dynamic Range 3.5Vpk-pk, ±1.75V (nominal)
Input Common Mode Voltage Range ±5 V (nominal)
Input Offset Voltage Range ±4 V Differential (nominal)
Non-destructive Input Range ±15 V (nominal)
Attenuation 3.75x (nominal)
DC Input Resistance (nominal) 200 kΩ Differential
50 kΩ Common mode
Impedance (Zmin, typical) >250 Ω Differential through entire frequency range using SI tip
Impedance (mid-band, typical) Dxx30-SI, Dxx30-QL-SI, and Dxx30-HiTemp Tips
470 Ω at 4 GHz, 320 Ω at 6 GHz, 260 Ω at 8 GHz, 250 Ω at 9 GHz, 260 Ω at 10 GHz, 350 Ω at 13 GHz
Dxx30-PT Tip
155 Ω at 4 GHz, 210 Ω at 6 GHz, 140 Ω at 8 GHz, 80 Ω at 9 GHz, 40 Ω at 10 GHz
CMRR 58 dB DC / 100 Hz
38 dB to 10 MHz
30 dB to 3 GHz
20 dB to 8 GHz
(typical)
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth
Product Description Product Code
Complete Differential Probes
8 GHz ProBus2 Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
D830-PB2
8 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
D830-PL
13 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
D1330-PL
Positioner Tip (Browser) Kits
WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable
Positioner Tip Kit. For use with Dxx30 ampliers.
Dxx30-PT-KIT
QuickLink Solder-In Tip Set
QuickLink Solder-In starter pack for use with Dxx30 amplier.
Includes one QuickLink adapter and three QL-SI tips.
Dxx30-QL-3SI
Hi-Temp Lead Set
WaveLink Temperature Extension Cables for Dxx30.
Includes set of Matched 30” High Temperature Cables (Qty. 1)
and solder-in lead set (Qty. 1).
Dxx30-HiTemp
SMA/SMP Lead Set
SMA/SMP lead set for use with Dxx30 ampliers.
Includes a set of SMA leads, SMP leads, pair of DC blocks
and SMA nger wrenches.
Dxx30-SMA-SMP-LEADS
Product Description Product Code
Accessories
Probe Deskew and Calibration Test Fixture TF-DSQ
Calibration Options
NIST Calibration for D830. Includes test data. D830-CCNIST
NIST Calibration for D1330. Includes test data. D1330-CCNIST
Replacement Parts
Single replacement QuickLink Solder-In Tip QL-SI-1Pack
9-pack of replacement QuickLink Solder-In Tip QL-SI-9Pack
Replacement Dxx30-SP 8-13 GHz Square Pin Lead Dxx30-SP
Replacement Dxx30-SI 8-13 GHz Solder-In Lead
with Qty. 5 Spare Resistors.
Dxx30-SI
Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI
and Dxx30-SI Solder-In Tip - Kit of 5
Dxx05-SI-RESISTORS
Qty. 4 Replacement Pogo Pin Tips and
Qty. 2 Replacement Sockets for Dx10-PT, Dx20-PT,
and Dxx30-PT Adjustable Positioner Tips.
Dxx0-PT-TIPS
Replacement Probe Tip Holder Kit PK600ST-3
Replacement Platform/Cable Assembly Mounting Kit PK600ST-4
Quantity 1 Package of Black Adhesive Pads (10/pkg) and
Quantity 1 Package of White Adhesive Pads (10/pkg)
Dxx0-PT-TAPE
Quantity 1 Package of Adhesive Probe Connection Guides
(200 individual guides/package)
Dxx05-PT-GUIDES
24
13 GHz - 25 GHz DIFFERENTIAL PROBES
Key Features
Up to 25 GHz bandwidth (probe + oscilloscope)
System rise time as fast as 13 ps (20–80%)
25 GHz Solder-in solution
22 GHz ultra-compact browser tip
Superior probe impedance minimizes AC loading on device under test (DUT)
Carbon-composite browser tips optimize signal fidelity and minimize loading
Probe noise as low as 14 nV/Hz (1.6 mVrms)
Low probe attenuation
Large operating voltage range
±4 V common mode range
±2.5 V offset range
2.0 Vpk-pk dynamic range
Long length Solder-In tip with field replaceable resistors
Ultra-wideband Architecture for Superior Signal Fidelity
Teledyne LeCroy’s WaveLink® high bandwidth differential probes utilize advanced
differential traveling wave (distributed) amplier architecture to achieve superior
high frequency true analog broadband performance. Traveling wave (distributed)
ampliers are commonly used in ultra high frequency broadband ampliers. This
multi-stage amplier architecture maximizes gain per stage and minimizes probe
attenuation, which provides very low probe noise and fast rise times.
Teledyne LeCroy
13 GHz - 25 GHz
Differential Probe
Model Numbers:
D1605-A-PLA
D2005-A-PLA
D2505-A-2.92MM
25
13 GHz - 25 GHz DIFFERENTIAL PROBES
D1605-A-PLA D2005-A-PLA D2505-A-2.92MM
Bandwidth Dxx05-SI and Dxx05-PT Tips
16 GHz (probe only, guaranteed)
16 GHz (system bandwidth,
when used with 816Zi, typical)
Dxx05-SI and Dxx05-PT Tips
20 GHz (probe only, guaranteed)
20 GHz (system bandwidth,
when used with 820Zi, typical)
Dxx05-SI Lead
25 GHz (probe only, guaranteed)
25 GHz (system bandwidth, when used with
825Zi, typical)
Dxx05-PT Tip
22 GHz (system bandwidth, when used with
825Zi, typical) 20 GHz (probe only, guaranteed)
Rise Time (10–90%) Dxx05-SI and Dxx05-PT Tips
28 ps (typical)
System rise time, measured
with 16 GHz oscilloscope
Dxx05-SI and Dxx05-PT Tips
20 ps (typical)
System rise time measured
with 20 GHz oscilloscope
Dxx05-SI Lead
17.5 ps (typical)
System rise time measured with 25 GHz
oscilloscope
Dxx05-PT Tip
19 ps (typical)
System rise time measured with 25 GHz
oscilloscope
Rise Time (20–80%) Dxx05-SI and Dxx05-PT Tips
21 ps (typical)
System rise time measured
with 16 GHz oscilloscope
Dxx05-SI and Dxx05-PT Tips
15 ps (typical)
System rise time measured
with 20 GHz oscilloscope
Dxx05-SI Lead
13 ps (typical)
System rise time measured with 25 GHz
oscilloscope
Dxx05-PT Tip
14 ps (typical)
System rise time measured with 25 GHz
oscilloscope
Noise (Probe) < 14 nV/Hz (1.8 mVrms)
(typical)
Referred to input,
16 GHz bandwidth
< 18 nV/Hz (2.5 mVrms)
(typical)
Referred to input,
20 GHz bandwidth
< 18 nV/Hz (2.8 mVrms)
(typical)
Referred to input,
25 GHz bandwidth
Noise (System) < 23 nV/Hz (2.9 mVrms)
(typical) Referred to input,
16 GHz bandwidth
< 28 nV/Hz (4.0 mVrms)
(typical) Referred to input,
20 GHz bandwidth
< 28 nV/Hz (4.5 mVrms)
(typical) Referred to input,
25 GHz bandwidth
Input
Input Dynamic Range 2.0 Vpk-pk, (±1.0 V) (nominal)
Input Common Mode Voltage Range ±4 V (nominal)
Input Offset Voltage Range ±2.5 V Differential (nominal)
Non-destructive Input Range ±10 V (nominal)
Attenuation 3.5x (nominal) 4.5x (nominal)
DC Input Resistance (nominal) 1.1 kΩ Differential
100 kΩ Common mode
Impedance (Zmin, typical) Dxx05-SI Lead
> 300 Ω Differential through entire frequency
range
Dxx05-PT Tip
>160 Ω Differential through entire frequency
range
Dxx05-SI Lead
> 230 Ω Differential through entire frequency
range
Dxx05-PT Tip
>160 Ω Differential through entire frequency
range
Dxx05-SI Lead
> 120 Ω Differential through entire frequency
range
Dxx05-PT Tip
>160 Ω Differential through entire frequency
range
Impedance (mid-band, typical) Dxx05-SI Lead: 300 Ω at 6 GHz, 525 Ω at 13 GHz, 600 Ω at 16 GHz, 300 Ω at 20 GHz, 120 Ω at 25 GHz
Dxx05-PT Tip: 160 Ω at 6 GHz, 450 Ω at 13 GHz, 240 Ω at 16 GHz, 210 Ω at 20 GHz
CMRR Dxx05-SI Lead (typical): 40 dB DC to 50 MHz; 32 dB to 1 GHz; 20 dB to 16 GHz; 15 dB to 25 GHz
Dxx05-PT Tip (typical): 36 dB DC to 50 MHz; 30 dB to 1 GHz; 16 dB to 16 GHz; 14 dB to 20 GHz
Environmental
Temperature Operating: 0 °C to 40 °C; Non-operating: -40 °C to 70 °C
Humidity Operating: 5% to 80% RH (non-condensing): 50% RH above 30 °C
Non-operating: 5% to 95% RH (non-condensing) 75% RH above 30 °C and 45% RH above 40 °C
ESD Tolerance 2 kV (typical)
100 pF, 300 Ω HBM
Product Description Product Code
Complete Differential Probes
16 GHz ProLink-A Differential Probe with Dxx05-SI Solder-In
Tip (Qty. 2)
D1605-A-PL
20 GHz ProLink-A Differential Probe with Dxx05-SI Solder-In
Tip (Qty. 2)
D2005-A-PL
25 GHz 2.92MM Differential Probe with Dxx05-SI Solder-In
Tip (Qty. 2)
D2505-A-2.92MM
Positioner Tip (Browser) Kits
WaveLink Dxx05-PT (Up to 22 GHz Rating) Adjustable
Positioner Tip Kit. For use with Dxx05 Ampliers
Dxx05-PT-KIT
Probe Adapters
ProLink to 2.92 mm Adapter with Probe Power
and Communication Pass Through
LPA-2.92
Product Description Product Code
Accessories
Probe Deskew and Calibration Test Fixture TF-DSQ
Calibration Options
NIST Calibration for D1605. Includes Test Data D1605-A-CCNIST
NIST Calibration for D2005. Includes Test Data D2005-A-CCNIST
NIST Calibration for D2505. Includes Test Data D2505-A-CCNIST
Replacement Parts
Replacement Dxx05-SI 16–25 GHz Solder-In Lead with
Qty. 5 Spare Resistors
Dxx05-SI
Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI
and Dxx30-SI Solder-In Tip - Kit of 5
Dxx05-SI-RESISTORS
Replacement Dxx05-PT Positioner Tip Dxx05-PT
Qty. 4 Replacement Carbon Composite Pogo-pin Tips Dxx05-PT-TIPS
Replacement Probe Tip Holder Kit PK600ST-3
Replacement Platform/Cable Assembly Mounting Kit PK600ST-4
Qty. 1 Package of Black Adhesive Pads (10/pkg.) and
Qty. 1 Package of White Adhesive Pads (10/pkg.)
Dxx0-PT-TAPE
Qty. 1 Package of Adhesive Probe Connection Guides
(200 individual guides/package)
Dxx05-PT-GUIDES
26
HIGH VOLTAGE DIFFERENTIAL PROBES
27
HIGH VOLTAGE DIFFERENTIAL PROBES
Differential active probes are like two probes in one. Instead of measuring
a test point in relation to a ground point (like single-ended active probes),
differential probes measure the difference in voltage of a test point in
relation to another test point.
Opposite page:
HVD3000A Series High Voltage Differential Probes
working with an MDA800A Motor Drive Analyzer
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3605A
AP031
28
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3605A
HIGH VOLTAGE DIFFERENTIAL PROBES
The HVD3000A series high voltage differential probes provide high CMRR over a
broad frequency range to simplify the measurement challenges found in noisy, high
common-mode power electronics environments. The probe’s design is easy-to-use
and enables safe, precise high voltage floating measurements.
Key Features
1 kV, 2 kV, 6 kV CAT safety rated models
Widest differential voltage ranges available
Exceptional common-mode rejection ratio (CMRR)
across a broad frequency range
1% gain accuracy
High offset capability at both high and low attenuation
AC and DC coupling
ProBus active probe interface with automatic scaling
AutoZero with auto disconnect switch
Wide oscilloscope compatibility
29
HIGH VOLTAGE DIFFERENTIAL PROBES
HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A
Bandwidth 25 MHz 120 MHz 80 MHz 120 MHz 80 MHz 100 MHz
Differential
Voltage
Range
1500 V
(DC + peak AC)
(1750V maximum
typical measurable
before saturation)
1500 V
(DC + peak AC)
(2000V maximum typical measurable
before saturation)
2000 V
(DC + peak AC)
7000 V
(DC + peak AC)
(7600 V maximum
typical measurable
before saturation)
Max Safe
Input
Voltage
1000 Vrms CAT III 2000 V (DC + peak AC) CAT I
1500 Vdc CAT III
1000 Vrms CAT III
8485 V (DC + peak AC)
CAT I
6000 Vrms CAT I
1000 Vrms CAT III
1000 Vdc CAT III
Gain
Accuracy
1%
Cable Length 2.25 meters 6.8 meters 2.25 meters 6.8 meters
Included Tip
Accessories
Yes Yes Yes Yes Yes Yes
HVD3206/3206-6M
High Voltage
Differential Probe
HVD3605
High Voltage
Differential Probe
HVD310X-NOACC
High Voltage
Differential Probe
PK-HVA-05
PK-HVA-01 PK-HVA-04
PK-HVA-03PK-HVA-02 PK-HVA-06 PK-HVA-07
PK-HVA-05
PK-HVA-01 PK-HVA-04
PK-HVA-03PK-HVA-02 PK-HVA-06 PK-HVA-07
HVD310X/310X-6M
High Voltage
Differential Probe
PK-HVA-05
PK-HVA-01 PK-HVA-04
PK-HVA-03PK-HVA-02 PK-HVA-06 PK-HVA-07
PK-HVA-05
PK-HVA-01 PK-HVA-04
PK-HVA-03PK-HVA-02 PK-HVA-06 PK-HVA-07
HVD3605A
HVD310xA / 310xA-6M
HVD3206A / 3206A-6M
HVD310xA-NOACC
PK-HVA-01
Safety Alligator Clips
(Red/Black)
1000 V CAT III
PK-HVA-02
Plunger Pincer Clips
(Red/Black)
1000 V CAT II
PK-HVA-03
Plunger Hook Clips
(Red/Black)
1000 V CAT II
PK-HVA-04
Plunger Alligator Clips
(Red/Black)
1000 V CAT III
PK-HVA-05
Spade Terminals
(Red/Black)
1000 V CAT III
PK-HVA-06
6 KV Safety Alligator Clips
(Red/Black)
6000 V CAT I
PK-HVA-07
2 kV Plunger Alligator Clips
(Red/Black)
2000 V CAT I
HVD-A Probe Accessories
30
HIGH VOLTAGE DIFFERENTIAL PROBES
Ordering Information
Product Description Product Code
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable HVD3102A
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3106A
1 kV, 80 MHz High Voltage Differential Probe with 6 m cable HVD3106A-6M
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3102A-NOACC
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3106A-NOACC
2 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3206A
2 kV, 80 MHz High Voltage Differential Probe with 6 m cable HVD3206A-6M
6 kV, 100 MHz High Voltage Differential Probe with 6 m cable HVD3605A
High Voltage Replacement Accessories Kit (Includes 2 each, 1 Black, 1 Red):
Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals PK-HV-001
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3605A
AP031
31
HIGH VOLTAGE DIFFERENTIAL PROBES
The AP031 is a low cost, battery operated active
differential probe intended for measuring higher
voltages. The differential techniques employed
permit measurements to be taken at two points in a
circuit without reference to the ground, allowing the
oscilloscope to be safely grounded without the use
of opto-isolators or isolating transformers.
Key Features
Safe floating measurements
15 MHz bandwidth
700 V maximum input voltage
Works with any 1 MΩ input oscilloscope
Specications
Attenuation ÷10 / ÷100
Bandwidth 15 MHz
Input R 4 MΩ
Differential Mode Range ±70 V / ±700 V DC + Peak AC
Common Mode Range ±700 V DC + Peak AC
CMRR 86 dB @ 50 Hz
Ordering Information
Product Description Product Code
700 V, 15 MHz Differential Probe (÷10, ÷100) AP031
AP031
32
DIFFERENTIAL AMPLIFIERS
Differential ampliers are intended to act as signal conditioning preampliers
for oscilloscopes and network and spectrum analyzers, providing differential
measurement capability to instruments having only a single-ended input. The
“-PR2” version of each amplier is a dual channel unit. The DXC series
differential input cables are matched to the characteristics of the amplier.
33
Opposite page:
DA1855A Differential Amplier working with the
HDO6000A oscilloscope for power measurement.
Teledyne LeCroy
Differential Amplier
and Accessory
Model Numbers:
DA1855A
DA1855-PR2
DA1855A-RM
DA1855A-PR2-RM
DXC5100
DXC100A
DXC200
DA101
34
DIFFERENTIAL AMPLIFIERS
The DA1855A is a stand-alone, high-
performance 100 MHz differential
amplier. It is intended to act as a
signal conditioning preamplier for
oscilloscopes, digitizers and spectrum
analyzers, providing differential
measurement capability to instruments
having only a single-ended input. When
used with a DA1855A, oscilloscopes
can obtain Common Mode Rejection
Ratio (CMRR) and overdrive recovery
performance levels previously
unobtainable.
Amplier gain can be set to 1 or
10 A built-in input attenuator can be
separately set to attenuate signals by
a factor of 10, providing gains of 10,
1, or 0.1 and common mode dynamic
range of ±15.5 V (÷1) or ±155 V (÷10).
Optional probes increase the maximum
input signal and common mode ranges
in proportion to their attenuation ratio
but do not exceed their maximum input
voltage rating. Effective gain of the
DA1855A, including probe attenuation,
amplier gain and attenuator settings, is
automatically displayed.
The DA1855A features a built-in
Precision Voltage Generator (PVG) that
can be set to any voltage between
±15.5 V (±10 V in Differential Offset)
with up to 100 µV resolution. The PVG’s
output can be selected as an input to
the inverting (-) input of the amplier for
operation as a differential comparator,
or applied internally as a true
differential offset voltage independent
of oscilloscope offset. The differential
amplier is also available in a 2 channel
model. In addition, a rackmount is
available for each model for easy
installation with other instruments.
Teledyne LeCroy
Differential Amplier
and Accessory
Model Numbers:
DA1855A
DA1855-PR2
DA1855A-RM
DA1855A-PR2-RM
DXC5100
DXC100A
DXC200
DA101
DA1855A
35
DIFFERENTIAL AMPLIFIERS
Ordering Information
Product Description Product Code
1 Ch, 100 MHz Differential Amplier with Precision Voltage Source DA1855A
2 Ch,100 MHz Differential Amplier with Precision Voltage Source DA1855A-PR2
DA1855A with Rackmount DA1855A-RM
DA1855A with Rackmount (must be ordered at time of purchase, no retrot) DA1855A-PR2-RM
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair DXC100A*
÷1, 50 MHz Passive Differential Probe Pair DXC200*
÷100, 250 MHz 2.5 kV, High Voltage Probe Pair (requires DA101 for full performance) DXC-5100*
÷10 1 MΩ Passive Attenuator for DXC Series Probes DA101*
*Must be used with DA Series Differential Ampliers
DXC100A
÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair
DC to 100 MHz Bandwidth with DA1855A
DC to 10 MHz Bandwidth with DA1822
Max Input Voltage 500 V
Selectable 10 or 100 Attenuation Factor
1.2 m Cable Length
DXC5100
÷100, 2.5KV Passive High Voltage Probe Pair. Requires DA101 for full performance
DXC200
÷1, 50 MHz, Passive Differential Probe Pair
DC to 50 MHz with DA1855A
DC to 10 MHz with DA1822A
Max Input Voltage 500 V (Limited to Amplier Max Input Voltage)
x1 Differential Probe Pair
0.7 m Cable Length
DA101
÷10, 1MΩ Passive Attenuator for DXC series probes
36
HIGH VOLTAGE PROBES
36
37
HIGH VOLTAGE PROBES
High voltage probes are suitable for a wide range of applications where
high-voltage measurements must be made safely and accurately. There
are several xed attenuation probes covering a range from 1 kV to 6 kV
and varying transient overvoltage ratings. All of these high voltage probes
feature a spring loaded probe tip and a variety of standard accessories
to make probing high voltages safe and easy. Additionally, all of the high
voltage probe have a probe sense pin to automatically congure the
oscilloscope for use with the probe.
Opposite page:
PPE Series High Voltage Probe
Teledyne LeCroy
High Voltage Probe
Model Numbers:
HVP120
PPE4KV
PPE5KV
PPE6KV
38
HIGH VOLTAGE PROBES
Teledyne LeCroy
High Voltage Probe
Model Number:
HVP120
Electrical Characteristics
Bandwidth 400 MHz
Risetime (10% - 90%) 900 ps (typical)
Maximum Input Voltage*
Measurement Category II 1000 Vrms
Measurement Category I 4000V Transient Overvoltage at 1000 Vrms
6000V Transient Overvoltage at 0 Vrms
Pollution Degree* 2
Input Capacitance 7.5 pF (typical)
Compensation Range 10 pF - 50 pF (typical)
Attenuation Ratio 100:1 ± 2%
Environmental
Temperature (Operating) 0°C to 50°C
Temperature (Non-Operating) -40°C to 71°C
Humidity (Operating) 80% RH (Non-Condensing) up to 31°C,
decreasing linearly to 40% RH at 50°C
Altitude (Operating) up to 2,000 m
Altitude (Non-Operating) up to 15,000 m
General Characteristics
Weight (probe) 67 g (0.15 lbs)
Cable Length 2 m (6.56 ft)
Probe Tip Diameter 5 mm (0.20 inches)
* As dened in IEC 61010-031
The HVP120 is a high voltage passive probe designed for probing up to
1,000 Vrms and capable of handling up to 6,000 V peak transients. Its
fast rise time and excellent frequency response make it suitable for a wide
variety of high voltage measurement applications. The HVP120 features
a spring loaded probe tip and a variety of standard accessories to make
probing high voltages safe and easy.
Product Description Product Code
400 MHz, High Voltage Passive Probe HVP120
High Voltage Replacement Accessories Kit PK-HV-002
Replacement Accessories
One of each of the following accessories are included with the HVP120. Replacement quantities are listed below.
Coding Rings (set) 4 Colors (Qty 3 also included standard) PK1-5MM-106
Ground Lead 22 cm to 4 mm Banana plug (Qty 1) PK1-5MM-122
Solid Tip 0.8 mm (Qty 5) PK1-5MM-125
Spring Tip 0.8 mm (Qty 5) PK1-5MM-126
BNC Adapter 5.0-L (Qty 1) PK1-5MM-127
Insulating Cap 5.0-L (Qty 1) PK1-5MM-128
Protection Cap 5.0-L (Qty 1) PK1-5MM-129
Sprung Hook 5.0-L (Qty 1) PK1-5MM-130
Adjustment Tool T (Qty 1) PK1-5MM-131
Flexible Adapter 5.0-L (Qty 1) PK1-5MM-132
Safety Alligator Clip red (Qty 1) PK1-5MM-133
Ground Lead 22 cm (Qty 1) PK1-5MM-134
Ordering Information
39
HIGH VOLTAGE PROBES
Ordering Information
Product Description Product Code
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 4 kV max. Voltage DC and Peak AC PPE4KV
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 5 kV max. Voltage DC and Peak AC PPE5KV
÷1000; 400 MHz; 50 MΩ High-Voltage Probe, 6 kV max. Voltage DC and Peak AC PPE6KV
Accessory Kit for PPE1.2kV, 2kV, 4kV, 5kV, and 6kV PK103
Sprung Hook (red) PK103-1
Ground Lead (22 cm) PP005-GL22
Crocodile Clip PK30x-2
Probe Tip to BNC Adapter PP005-BNC
Spring Tip (0.8 mm) PP005-ST8
Rigid Tip V2A PP005-RT
Supplied with probe:
* Probe Kit: Trimming tool, ground lead, rigid tip, IC insulator, BNC adapter, tip insulator, spring hook, red crocodile clip.
4 mm safety ground lead, and green/yellow crocodile clip.
The PPE series includes four xed-attenuation probes covering a range from
2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for
voltage inputs up to 1.2 kV. All xed-attenuation, standard probes automatically
rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation
of the probe.
PPE High-Voltage Probes Selection Guide Specications
Types Bandwidth Input R Input C Attenuation Maximum Probe Cable
(MHz) (Ω) (pF) Voltage Encoding
PPE4kV* 400 50 M < 6 ÷100 4 kV Yes 2 m
PPE5kV* 400 50 M < 6 ÷100 5 kV Yes 2 m
PPE6kV* 400 50 M < 6 ÷1000 6 kV Yes 2 m
Sprung Hook
BNC Adapter Insulating Tip IC Insulating Tip Straight Tip
(0.8 mm)
Spring Contact Tip
(0.8 mm)
Trimming Tool
Crocodile Clip (Black) Crocodile Clip (Red)
Ground Lead
(22 cm)
Security Ground Lead
Flexible 4 mm
Security Adapter
Teledyne LeCroy
High Voltage Probe
Model Numbers:
PPE4KV
PPE5KV
PPE6KV
40
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
41
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
Teledyne LeCroy
Probe Adapter
Model Numbers:
HVFO103
The HVFO is an affordable, optimally designed probe for measurement of
small signals oating on an HV bus in power electronics designs or for
EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpass-
es the measurement capabilities and signal delity of both conventional
HV differential probes and acquisition systems that rely on galvanic high
voltage isolation. Furthermore, it mitigates the need to rely on dangerous
test setups that require oating the oscilloscope and probe.
Opposite page:
High Voltage Fiber Optically-isolated Probe HVFO103 working
with an HDO8000A High Denition Oscilloscope.
42
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
Teledyne LeCroy
High Voltage Fiber
Optically-isolated Probe
Model Number:
HVFO103
Key Features
Applications
Upper-side gate drive signal measurements
Floating control signal or sensor voltage measurements
EMC, EFT, ESD, and RF immunity testing and system optimization
Any small signal measurements with high common-mode voltage
60 MHz bandwidth
35 kV common-mode voltage rating (ber optic isolation)
Superior Noise and Rejection
140 dB CMRR
Low loop inductance
Low attenuation
Reduced DUT loading, better pulse response compared to conventional
HV differential probes
Selectable tips from ±1V to ±40V
Eliminates need to “oat” the oscilloscope
ProBus-compatible with many Teledyne LeCroy oscilloscopes
The HVFO is an affordable, optimally designed probe for measurement of small
signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD,
and RF immunity testing sensor monitoring. It far surpasses the measurement
capabilities and signal delity of both conventional HV differential probes and
acquisition systems that rely on galvanic high voltage isolation. Furthermore,
it mitigates the need to rely on dangerous test setups that require floating the
oscilloscope and probe.
43
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
Product Description Product Code
High Voltage Fiber Optically-isolated Probe Models and Accessories
High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case, Qty. 1 Amplier/Modulating Transmitter, Qty. 1
Demodulating Receiver, Qty. 1 1m Fiber Optic Cable, Qty. 1 USB Charging Cable, Qty. 1 Micro-gripper set.
Attenuating Tips must be ordered separately.
HVFO103
±1V (1x) Attenuating Tip Accessory HVFO100-1X-TIP
±5V (5x) Attenuating Tip Accessory HVFO100-5X-TIP
±20V (20x) Attenuating Tip Accessory HVFO100-20XTIP
±40V (40x) Attenuating Tip Accessory HVFO100-40X-TIP
Spare Amplier/Modulating Transmitter (permits constant operation - charge one while another is being used) HVFO103-XMITTER
1m Spare Fiber Optic Cable Accessory HVFO-1M-FIBER
2m Fiber Optic Cable Accessory HVFO-2M-FIBER
6m Fiber Optic Cable Accessory HVFO-6M-FIBER
NIST Traceable Calibration Certicate HVFO103-CCNIST
Electrical
Bandwidth 60 MHz (typical, with tip attached)
Rise Time (10-90%) 7.5 ns (typical)
Input Dynamic Range ±1V, ±5V, ±20V, ±40V (DC+peak AC) respectively with 1X, 5X, 10X or 20X attenuating tips.
All tips are purchased as accessories (none are included with HVFO103 probe).
Maximum Non-destruct Voltage 5 times the operating voltage rating (tip dependent)
Common Mode Voltage Range ±35 kV (DC+Peak AC)
(not for hand-held use, user must maintain adequate spacing between floating probe components and earth ground.)
Maximum Input Voltage to Earth ±35 kV (DC+Peak AC)
(not for hand-held use, user must maintain adequate spacing between floating probe components and earth ground.)
Maximum Safe Input Voltage For hand-held use, 30 Vrms / 60 Vdc per IEC/EN 61010-031 Ed. 2.0 b:2015
Offset Offset capability determined by oscilloscope offset available in a given gain (V/div) setting after accounting for total
probe attenuation (total probe attenuation is twice the tip attenuation).
Sensitivity 50 mV/div to 1 V/div (1X tip), 250 mV/div to 5 V/div (5X tip), 1 V/div to 20 V/div (20X tip), 2 V/div to 40 V/div (40X tip)
Gain Accuracy 2% (LF, guaranteed)
Input Impedance 1 MΩ || 34 pF (1X tip); 5 MΩ || 26 pF (5X tip); 10 MΩ || 22 pF (20X tip); 10 MΩ || 22 pF (40X tip)
Input/Output Coupling DC only
Interface ProBus
Cable Length 1.25 m (4.1 feet) from input lead to oscilloscope connection (using included 1 meter ber optic cable)
Battery 6 hour battery life (typical). 1.5 hour re-charge time (typical, with user-supplied dedicated USB charger).
3 hour re-charge time (typical) using supplied USB charging cable connected to oscilloscope USB port
Noise and Rejection
CMRR (typical) 140 dB (100 Hz), 120 dB (to 1 MHz), 85 dB (to 10 MHz), 60 dB (to 60 MHz)
Noise (Probe only) 7 mVrms (1X tip), 35 mVrms (5X tip), 140 mVrms (20X tip), 280 mVrms (40X tip)
Environmental
Temperature 0°C to 50°C (operating), -20°C to 70°C (non-operating)
Humidity 5% to 80% RH (non-condensing) up to 30°C, decreasing linearly to 45% RH at 50°C (operating)
5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C (non-operating)
Altitude 3000 m (operating), 10,000 m (non-operating)
Pollution Degree 2, Indoor Use Only
Certications
CE (LVD Directive 2006/95/EC) IEC/EN 61010-031/A1:2008, Pending IEC/EN 61010-031:2015
CE (EMC Directive 2004/108/EC) IEC/EN 61326-1:2013
uL Listed UL 61010-031 (First Edition), Pending UL 61010-031 (Second Edition)
cUL Listed CAN/CSA - C22.2 No. 61010-031-07, Pending CAN/CSA-C22.2 No. 61010-031-15
Compatibility
Compatible
With...
Fully compatible with HDO4000 Series, HDO6000 Series, HDO8000 Series, MDA800 Series, HDO9000 Series,
WaveRunner 8000 Series, WaveRunner 6 Zi Series, WavePro 7 Zi Series, and WaveMaster 8 Zi Series.
Ordering Information
44
OPTICAL-TO-ELECTRICAL CONVERTERS
45
OPTICAL-TO-ELECTRICAL CONVERTERS
Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters
are designed for measuring optical communications signals. Their broad
wavelength range and multi-mode input optics make these devices ideal for
applications including Ethernet, Fibre Channel, and ITU telecom standards.
Available to support optical data rates up to 11.3 Gb/s with reference
receivers, or slightly higher without reference receivers.
These wide- band multi-mode optical-to-electrical converters are designed
for measuring optical communications signals. They connect to Teledyne
LeCroy real-time oscilloscopes and provide capability for physical layer
signal assessment using a variety of oscilloscope tools, such as
SDAIII-CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis,
mask testing, serial triggering and decoding, and other compliance and
debug tools. Maximum data rate test capability is >11.317 Gb/s with
reference receiver, or 12.5 Gb/s without.
Opposite page:
OE6250G-M Optical Probe working with the LabMaster 10 Zi-A oscilloscope.
Teledyne LeCroy
Optical Probe
Model Numbers:
OE6250G-M
OE695G
OE425
OE455
OE525
OE555
46
OPTICAL-TO-ELECTRICAL CONVERTERS
Teledyne LeCroy
Optical Probe
Model Numbers:
OE6250G-M
OE695G
OE425
OE455
OE525
OE555
OE6250G-M
The OE6250G optical-to-electrical converter enables optical signal measure-
ment of intensity-modulated signals up to 28 Gbaud and beyond on LabMaster
or WaveMaster series real-time oscilloscopes. As a fully calibrated module, the
OE6250G-M integrates seamlessly into the oscilloscope software to give optical
intensity measurement straight out of the box. Teledyne LeCroy’s extensive tool-
set includes powerful analysis tools for NRZ, PAM4, and other signal types, and
enables custom signal processing and reference receiver implementation.
Key Features
Optical-to-electrical converter for
intensity-modulated signals to 28
Gbaud and higher
– Up to 25 GHz bandwidth with
a 4th-order Bessel-Thomson
frequency
response
– Up to 36 GHz bandwidth with a flat
frequency response
DC-coupled detector for accurate
signal reproduction with a real-time
oscilloscope
Fully calibrated and integrated
50/125 µm multi-mode ber input
Ideal for Eye Mask, Extinction Ratio,
and Optical Modulation Amplitude
(OMA) testing
OE6250G-M Specifications
Typical
Analog Bandwidth 25 GHz (Bessel-Thomson response mode),
36 GHz (Flatness response mode)
Wavelength Range 830nm - 1600nm
Calibration Wavelengths 850nm, 1310nm, 1550nm
Conversion gain at 850nm -80 V/W
Conversion gain at 1310nm -125 V/W
Conversion gain at 1550nm -125 V/W
Electrical output coupling DC coupled
5% compression point at 1550nm 4 mW (minimum)
Noise measured up to 50GHz 500 uV RMS
Optical Return Loss 19 dB
Polarization dependent loss at 1550 nm 0.1 dB
RF impedance 50 Ω
Fiber (core/cladding) 50/125 µm
RF connector 2.92 mm
Optical Connector FC/PC or SC/PC
Note: All specications subject to change without notice.
47
OPTICAL-TO-ELECTRICAL CONVERTERS
Ordering Information
Product Description Product Code
Optical-to-Electrical Converter, DC to 36 GHz, 830 to 1600nm OE6250G-M
Optical-to-Electrical Converter, 785 to 1550 nm, 2.92 mm connector with ProLink adapter OE695G
Optical-to-Electrical Converter, 500–870 nm ProBus BNC Connector OE425
Optical-to-Electrical Converter, 950–1630 nm ProBus BNC Connector OE455
Optical-to-Electrical Converter, 500–870 nm ProLink BMA Connector OE525
Optical-to-Electrical Converter, 950–1630 nm ProLink BMA Connector OE555
OE425/OE455/OE525/OE555
The O/E converters contain calibration data that can be
used to create optical reference receivers for SONET/
SDH (up to OC48/STM16), Fibre Channel, Gigabit Ether-
net, and other optical standards. This feature is available
when the O/E is used on a supported oscilloscope. The
universal reference receiver supports any data rate up
to 3 GHz and remains calibrated on any channel of the
oscilloscope.
Key Features
Frequency range to 5 GHz (6 GHz optical)
62.5 µm or narrower multi-mode or single-mode
fiber input
Broad wavelength range:
– 500–870 nm (OE425, OE525)
– 950–1630 nm (OE455, OE555)
High responsivity
Low noise
Included Accessories:
Multi-mode optical ber jumper FC-FC
FC to ST adapter
FC to SC adapter
Key Features
Compatible with LabMaster 10 Zi oscilloscopes
Frequency range DC to 9.5 GHz (electrical, -3 dB)
Reference receiver support from 8GFC to 10GFC FEC, or
Custom (<12.5Gb/s)
Full bandwidth mode (no reference receiver applied)
62.5/125 µm multi-mode or single-mode ber input
Broad wavelength range (750 to 1650 nm)
+7 dBm (5 mW) max peak optical power
Low noise (as low as 25 pW/Hz)
Ideal for Eye Mask, Extinction Ratio, and Optical
Modulation Amplitude (OMA) testing
OE695G
The OE695G wide-band optical-to-electrical converter is
ideal for measuring optical datacom and telecom signals
with data rates from 622 Mb/s to 12.5+ Gb/s. Connection
to a real-time Teledyne LeCroy oscilloscope is through the
2.92mm interface, with a provided adapter to connect to
ProLink interfaces.
48
PASSIVE PROBES
48
49
PASSIVE PROBES
Passive probes are the standard probe provided with most
oscilloscopes. Typical passive probes provide a ÷10 attenuation and
feature a high input resistance of 10 MΩ. This high input resistance
means that passive probes are the ideal tool for low frequency signals
since circuit loading at these frequencies is minimized. Passive probes
are designed to handle voltages of at least 400 V, some as high as
600 V. Teledyne LeCroy passive probes feature an attenuation sense
pin which tells the oscilloscope to scale the waveforms automatically
requiring no user input.
Teledyne LeCroy
Passive Probe
Model Numbers:
PP006C
PP016
PP019
PP020
PP021
PP022
PP023
PP024
PP025
PP026
50
PASSIVE PROBES
Specications
Types Bandwidth Input R Input C Attenuation Maximum Diameter
Voltage
PP006C 500 MHz 10 MΩ 12 pF ÷10 500 V 5 mm
PP016 300 MHz/ 10 MΩ/ 12 pF/ ÷10/ 600 V 5 mm
10 MHz 1 46 pF ÷1
PP019 200 MHz 10 MΩ 12 pF ÷10 500 V 5 mm
PP020 500 MHz
10 MΩ
11 pF
÷10
500 V
5 mm
PP021 500 MHz 10 MΩ 11 pF ÷10 500 V 2.5 mm
PP022 500 MHz 10 MΩ 10 pF ÷10 500 V 2.5 mm
PP023 500 MHz 10 MΩ 10 pF ÷10 500 V 2.5 mm
PP024 500 MHz 10 MΩ 10 pF ÷10 500 V 5 mm
PP025 500 MHz 10 MΩ 10 pF ÷10 500 V 5 mm
PP026 500 MHz 10 MΩ 10 pF ÷10 500 V 5 mm
Each passive probe is recommended for a certain oscilloscope, using the right
passive probe with the right oscilloscope means that the probe can be properly
compensated across the entire bandwidth. Using probes with a different
oscilloscope will only let you compensate for low frequencies.
Teledyne LeCroy
Passive Probe
Model Numbers:
PP006C
PP016
PP019
PP020
PP021
PP022
PP023
PP024
PP026
Passive Probe Accessories for PP006C
Replacement Part Kit: PK116
Passive Probe Accessories for PP016
Replacement Part Kit: PKIT3-5MM-101
Set Coding Rings
2x4 colors
2. PP006C Std. Accessories
PK116-1
Sprung Hook
Trimmer Tool
PK116-2
Ground Lead
PK116-3
Ground Spring
IC Insulating Tip
Sprung Hook
Ground Lead
Ground Spring
Trimmer Tool
Color Coding Rings
(set)
BNC Adapter
Rigid Tip
Tip Insulator
IC Tip Insulator
51
PASSIVE PROBES
Ordering Information
Product Description Product Code
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 PP006C
10:1, 10 MΩ, 300 MHz Passive Probe PP016
250 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 PP019
500 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 PP020
500 MHz Passive Probe, 2.5mm, 10:1, 10 PP021
500 MHz Passive Probe, 2.5mm, 10:1, 10 PP022
500 MHz Passive Probe, 2.5mm, 10:1, 10 PP023
500 MHz Passive Probe, 5mm, 10:1, 10 PP024
500 MHz Passive Probe, 5mm, 10:1, 10 PP025
500 MHz Passive Probe, 5mm, 10:1, 10 PP026
Passive Probe Accessories for
PP021, PP022, and PP023
Replacement Part Kit: PKIT5-2.5MM-101
Passive Probe Accessories for
PP019 and PP020 – Part numbers in blue
Replacement Part Kit: PKIT4-5MM-101
PP024, PP025, and PP026 – Part numbers in gray
Replacement Part Kit: PKIT6-5MM-101
Passive Probe Accessories for PP016
Replacement Part Kit: PKIT3-5MM-101
PK4-5MM-3
PK6-5MM-106
BNC Adapter 5mm
PK6-5MM-105
PCB Adapter
PK4-5MM-4
PK6-5MM-101
Rigid Probe Tip
PK4-5MM-9
PK6-5MM-104
Ground Spring
PK4-5MM-1
PK6-5MM-102
Sprung Hook
PK4-5MM-2
PK6-5MM-103
Ground Lead with Alligator Clip
PK4-5MM-7
PK6-5MM-110
Tip Insulator
PK6-5MM-108
Probe Tip Cover
PK4-5MM-6
PK6-5MM-109
IC Tip Insulator
PK6-5MM-107
Spring Tip
PK4-5MM-5
PK5-PK6-001
Trimmer Tool
PK4-5MM-8
PK5-PK6-002
Color Coding Rings
(set)
PK6-5MM-108
Probe Tip Cover
PK5-2.5MM-109
BNC Adapter 2.5mm
PK5-2.5MM-113
PCB Adapter
PK5-2.5MM-102
Rigid Probe Tip
PK5-2.5MM-112
Ground Spring
PK5-2.5MM-111
Swivel Ground
Lead Adapter
PK5-2.5MM-104
Sprung Hook
PK5-2.5MM-101
Ground Lead with
Alligator Clip
PK5-2.5MM-107
Tip Insulator
2.5mm Cap
PK5-2.5MM-108
Probe Tip Cover
PK5-PK6-001
Trimmer Tool
PK5-PK6-002
Color Coding Rings
(set)
PK5-2.5MM-105
Long Collar
PK5-2.5MM-103
Short Collar
PK5-2.5MM-106
IC Tip Insulators (Black, Brown, Blue, Green, Gray)
PK5-2.5MM-110
Swivel Ground Lead
PK5-2.5MM-114
Spring Tip
52
Key Features
Provides ability for third party
current sensor to operate like a
Teledyne LeCroy probe
Programmable EEPROM for
saving third party current sensor
parameters
Allows for addition of shunt
resistor and RLC lter components
ProBus Active interface with
automatic scaling in A/div
Easy to use, saves time and
possible errors
CA10
The CA10 is a programmable and customizable interface device that seamlessly
incorporates third party current transducers/transformers with Teledyne LeCroy
oscilloscopes or motor drive analyzers. The easy to use interface provides the
ability for the CA10 to be programmed to contain the specications of the current
sensor allowing it to automatically correct for the gain or attenuation and display
results in Ampere units. This allows the third party device to be recognized and
operate as if it were a Teledyne LeCroy probe.
Product Description Product Code
ProBus Current Sensor Adapter CA10
Set of 4 CA10, ProBus Current Sensor Adapter CA10-QUADPAK
Included with Standard Conguration CA10
Description Qty
CA10 ProBus Current Adapter
1
Heat-Shrink tubing (6" length)
1
Removable Labels (sheet of 20)
1
Specications
Input Coupling DC, AC, Both
Input Termination 1MΩ or 50Ω
Programmable Bandwidth Filters Full, 200 MHz, 20 MHz
Transformer/Transducer Interface BNC
Scaling Factors Programmable
Resistive Termination (if required) Customizable (See Operator’s Manual for details)
Oscilloscope Interface Teledyne LeCroy ProBus
Note: Some third party devices will require a separate power supply or batteries. The CA10 does not have
the ability to supply the power to these devices.
Ordering Information
Teledyne LeCroy
Probe Adapter
Model Numbers:
CA10
TPA10
PROBE ADAPTERS
Probe adapters provide simple and easy interface of third-party probes as well
as change between the different Teledyne LeCroy Oscilloscope input and cable
types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapt-
ers, changing between the Teledyne LeCroy Oscilloscope’s input type may have
an effect on the overall performance of the channel.
53
Key Features
Allows TekProbe™ interface level II
probes to work with any
ProBus-equipped Teledyne LeCroy
oscilloscope
Automatic probe detection
Provides all necessary power and
offset control to the attached probe
Supports probes up to 4 GHz
Easy rmware updates
Wide variety of probes
supported including:
Preampliers
Current Probes
Single-Ended Active Probes
Differential Active Probes
TPA10
The TPA10 ProBus™ Probe Adapter enables you to connect select TekProbe
interface level II probes to any ProBus-equipped Teledyne LeCroy instrument.
The TPA10 supplies all necessary power and offset control to the probe and
automatically detects which probe is attached.
Product Description Product Code
TPA10 ProBus Adapter TPA10
Set of 4 TPA10, TPA10 ProBus Adapters TPA10-QUADPAK
Supported Probes
The following TekProbe devices are supported for use
with TPA10:
Preampliers
1 MHz Differential Preamplier ADA400A
Current Probes
50 MHz AC/DC Current Probe TCP202/TCP202A
Single-ended Active Probes
750 MHz Single-ended Active Probe P6205
1 GHz Single-ended Active Probe P6243
1.5 GHz Single-ended Active Probe P6245
4 GHz Single-ended Active Probe P6241
4 GHz Single-ended Active Probe P6249
Differential Active Probes
100 MHz Differential Probe P5205/P5205A
50 MHz Differential Probe P5210/P5210A
400 MHz Differential Probe P6246
1 GHz Differential Probe P6247
1.5 GHz Differential Probe P6248
500 MHz Differential Probe P6250
1 GHz Differential Probe P6251
Specications
Electrical Characteristics
Bandwidth 4 GHz (adapter only)
Power Supplies +15V, -15V, +5V, -5V (each 2%)
Offset Voltage ±1V (1%)
Max. Input Voltage 47 Vpk, 33 Vrms
Environmental
Operating Temperature Range 0 to 50 ºC
Non-operating Temperature Range -40 to +70 ºC
Humidity 5% to 95% RH (10 to 40 ºC);
5% to 75% (above 40 ºC);
RH not controlled below 10 ºC
Operating Altitude 3000 meters maximum
Physical
Dimensions (WxHxD) 39 mm x 31.1 mm x 88.6 mm
(1.54” x 1.22” x 3.49”)
Weight 119 g (0.26 lb)
The TPA10 requires the Teledyne LeCroy oscilloscope to be running rmware
version 7.8.0.0 or greater.
Ordering Information
PROBE ADAPTERS
54
Transmission line probes are a special type of passive probe designed for use at
very high frequencies. They replace the high impedance probe cable found in a
traditional passive probe with a precision transmission line, with a characteristic
impedance that matches the oscilloscope input (50 Ω). This greatly reduces
the input capacitance to a fraction of a picofarad, minimizing the loading of
high frequency signals. A matching network at the tip increases the DC input
resistance. While they have lower DC input resistance than a traditional passive
probe (usually 500 Ω to 5 kΩ), the input impedance of these probes remains
nearly constant over their entire frequency range. A traditional ÷10 passive probe
will have a 10 MΩ input impedance at DC, however this impedance drops rapidly
with frequency, passing below the input impedance of a transmission line probe at
less than 100 MHz.
In some applications, transmission line probes offer advantages over active
probes. In addition to being less expensive, their passive design is more robust
to over voltage and ESD exposure. They are useful in applications producing fast
rising, narrow pulses with amplitudes which exceed the dynamic range of active
probes. They also tend to have less parasitic effects on frequency response.
TRANSMISSION LINE PROBES
Teledyne LeCroy
Transmission Line Probe
Model Number:
PP066
55
PP066
The PP066 is a high-bandwidth passive probe designed for use
with the WaveMaster and other high-bandwidth oscilloscopes
with 50 Ω input termination. This very low capacitance probe
provides an excellent solution for higher frequency applications,
especially the probing of transmission lines with 20–100 Ω
impedance. The PP066 accommodates a wide range of
applications, including probing of analog and digital ICs
commonly found in computer, communications, data storage,
and other high-speed designs.
Key Features:
Interchangeable attenuator tips
Signal integrity at high bandwidth
Standard SMA cable connection
Ultra low capacitance
PP066 Specications
Electrical Characteristics
Bandwidth DC to 7.5 GHz
Risetime < 47 ps
Input Capacitance < 0.20 pF
Input Resistance 500 Ω (÷10 cartridge)
1000 Ω (÷20 cartridge)
Maximum Voltage 15 V rms
Cable Length 1 m
Ordering Information
Product Description Product Code
7.5 GHz Low Capacitance Passive Probe
(÷10, 1 kΩ; ÷20, 500 Ω)PP066
Included with PP0066
PACC-AD001, SMA to BNC Adapter
TRANSMISSION LINE PROBES
tlec_probecatalog-14may18
© 2018 Teledyne LeCroy, Inc. All rights reserved. Specications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
Local sales oces are located throughout the world.
Visit our website to nd the most convenient location.
1-800-5-LeCroy
teledynelecroy.com