VRM10 Series
Single output
NEW Product
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
•
Designed for use in low profile applications where VRM10.0 or
10.1 specifications are required
•Output current up to 85 A continuous
•Open-collector power good (PWRGD) output
•6-bit microprocessor voltage identification input (VID)
-0.8375 Vdc to 1.6000 Vdc in 12.5 mV steps
-Allows dynamic VID code changes
•Differential remote sense for improved load regulation
•Vertical plug-in to standard motherboard connector
•Selectable output load line impedances, via LL0 and LL1
•Output over-voltage signal (OVP)
•Monotonic output turn-on and turn-off with no overshoot or
undershoot
•Available RoHS compliant
The VRM10 non-isolated dc-dc converter is designed to meet the exceptionally fast
transient response requirements of today’s microprocessors and fast switching logic in a
compact size at a veryaffordable price. Advanced Circuit techniques, component selection
and placement optimization, state-of-the-artthermal packaging, and surface-mount
Technologies provide a high power density,highly reliable, and very precise voltage
regulation system for advanced microprocessors. 2YEAR WARRANTY
Unless otherwise stated, all specifications are typical at nominal input, maximum
continuous rated load at 25 °Cand voltages arereferenced to Vin-. SPECIFICATIONS
DC-DC CONVERTERS 80 A/85 A Non-Isolated 1
International Safety Standard Approvals
VDE Certificate No. 2487000-3336-0016
GENERAL CHARACTERISTICS
Efficiency VID = 1.325 V @ 85 A 85% typ.
Switching frequency Fixed (See Note 4) 2.2 MHz
Approvals and standards (See Note 5) IEC/EN60950 VDE
Material flammability UL94V-0
Weight 38 g (1.34 oz)
MTBF Telecordia SR-332 2,000,000 hours
Mating connector Tyco/Amp p/n: 1489930-2
(See Table 2 for pin out) Foxconn p/n: 2EV04607-NW
Connector fingers Gold plated, 30 µ-inches
ENVIRONMENTAL SPECIFICATIONS
Temperature shock Operating 10 ºC/hour
non-operating 20 ºC/hour
Humidity Operating 85% RH
(Non-condensing) storage 95% RH
Altitude Operating 10,000 feet max.
storage 50,000 feet max.
Shock Operational and 30 G 11 ms
non-operational Half sine wave
Vibration Operational and 0.02 G2/Hz max.
(See Note 6) non-operational
Thermal performance Operating ambient 0 ºC to +60 ºC
(See Note 7) temperature
Storage temperature (Non-condensing) -40 ºC to + 100 ºC
OUTPUT SPECIFICATIONS
Voltage adjustability
(See VID codes,Table 3) 0.8375-1.6000 Vdc
Output current (Iout) 0 A min.
VRM10-85-12-UY Continuous 85 A max.
Peak non-sustained 100 A max.
VRM10-80-12-PY Continuous 80 A max.
Peak non-sustained 91 A max.
Load line (LL) adjustability 0.91 to 1.25 mΩ
(See LL codes, Table 1)
Output voltage (Vout) Vo max VID - Rout * Iout V
(Vo sen+ minus Vo sen-) Vo min VID - Rout * Iout - 0.040 V (-U)
(See Notes 3, B) Vo min VID - Rout * Iout - 0.038 V (-P)
Where VID = programmed voltage (V)
Rout Fixed or programmable
output impedance (Ω)
Iout Output current (A)
Ripple and noise 20 MHz bandwidth 8 mV pk-pk
(See Notes 1, 2)
Short-circuit protection Continuous current limit,
brickwall automatic recovery
Remote sensing compensating voltage Up to 300 mV max.
INPUT SPECIFICATIONS
Input voltage range 12Vin nominal 11.0-12.6 Vdc
Input current
VRM10-85-12-UY 11 Vin, VID=1.325 V, Iout=100 A 15.3 A
VRM10-80-12-PY 11 Vin, VID=1.400 V
,Iout=91 A 14.2 A
No load 250 mA typ., 300 mA max.
OUTEN OFF 50 mA max.
UVLO turn ON voltage 0 ºC <tamb <60 ºC 9.5 V ± 2.6%
UVLO turn OFF voltage 0 ºC <tamb <60 ºC 8.7 V ± 4.5%
Hysteresis 0.8 V typ.
Start-up time 11.0 V < Vin <12.6 V 10 ms max.
(using OUTEN) (PWRGD transitioning high)
OUTEN, VID and LL signal valid states:
ON or Logic ‘1’ 0.8 Vdc min., 5.5 Vdc max.