VRM10 Series
Single output
NEW Product
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
Designed for use in low profile applications where VRM10.0 or
10.1 specifications are required
Output current up to 85 A continuous
Open-collector power good (PWRGD) output
6-bit microprocessor voltage identification input (VID)
-0.8375 Vdc to 1.6000 Vdc in 12.5 mV steps
-Allows dynamic VID code changes
Differential remote sense for improved load regulation
Vertical plug-in to standard motherboard connector
Selectable output load line impedances, via LL0 and LL1
Output over-voltage signal (OVP)
Monotonic output turn-on and turn-off with no overshoot or
undershoot
Available RoHS compliant
The VRM10 non-isolated dc-dc converter is designed to meet the exceptionally fast
transient response requirements of today’s microprocessors and fast switching logic in a
compact size at a veryaffordable price. Advanced Circuit techniques, component selection
and placement optimization, state-of-the-artthermal packaging, and surface-mount
Technologies provide a high power density,highly reliable, and very precise voltage
regulation system for advanced microprocessors. 2YEAR WARRANTY
Unless otherwise stated, all specifications are typical at nominal input, maximum
continuous rated load at 25 °Cand voltages arereferenced to Vin-. SPECIFICATIONS
DC-DC CONVERTERS 80 A/85 A Non-Isolated 1
International Safety Standard Approvals
VDE Certificate No. 2487000-3336-0016
GENERAL CHARACTERISTICS
Efficiency VID = 1.325 V @ 85 A 85% typ.
Switching frequency Fixed (See Note 4) 2.2 MHz
Approvals and standards (See Note 5) IEC/EN60950 VDE
Material flammability UL94V-0
Weight 38 g (1.34 oz)
MTBF Telecordia SR-332 2,000,000 hours
Mating connector Tyco/Amp p/n: 1489930-2
(See Table 2 for pin out) Foxconn p/n: 2EV04607-NW
Connector fingers Gold plated, 30 µ-inches
ENVIRONMENTAL SPECIFICATIONS
Temperature shock Operating 10 ºC/hour
non-operating 20 ºC/hour
Humidity Operating 85% RH
(Non-condensing) storage 95% RH
Altitude Operating 10,000 feet max.
storage 50,000 feet max.
Shock Operational and 30 G 11 ms
non-operational Half sine wave
Vibration Operational and 0.02 G2/Hz max.
(See Note 6) non-operational
Thermal performance Operating ambient 0 ºC to +60 ºC
(See Note 7) temperature
Storage temperature (Non-condensing) -40 ºC to + 100 ºC
OUTPUT SPECIFICATIONS
Voltage adjustability
(See VID codes,Table 3) 0.8375-1.6000 Vdc
Output current (Iout) 0 A min.
VRM10-85-12-UY Continuous 85 A max.
Peak non-sustained 100 A max.
VRM10-80-12-PY Continuous 80 A max.
Peak non-sustained 91 A max.
Load line (LL) adjustability 0.91 to 1.25 m
(See LL codes, Table 1)
Output voltage (Vout) Vo max VID - Rout * Iout V
(Vo sen+ minus Vo sen-) Vo min VID - Rout * Iout - 0.040 V (-U)
(See Notes 3, B) Vo min VID - Rout * Iout - 0.038 V (-P)
Where VID = programmed voltage (V)
Rout Fixed or programmable
output impedance ()
Iout Output current (A)
Ripple and noise 20 MHz bandwidth 8 mV pk-pk
(See Notes 1, 2)
Short-circuit protection Continuous current limit,
brickwall automatic recovery
Remote sensing compensating voltage Up to 300 mV max.
INPUT SPECIFICATIONS
Input voltage range 12Vin nominal 11.0-12.6 Vdc
Input current
VRM10-85-12-UY 11 Vin, VID=1.325 V, Iout=100 A 15.3 A
VRM10-80-12-PY 11 Vin, VID=1.400 V
,Iout=91 A 14.2 A
No load 250 mA typ., 300 mA max.
OUTEN OFF 50 mA max.
UVLO turn ON voltage 0 ºC <tamb <60 ºC 9.5 V ± 2.6%
UVLO turn OFF voltage 0 ºC <tamb <60 ºC 8.7 V ± 4.5%
Hysteresis 0.8 V typ.
Start-up time 11.0 V < Vin <12.6 V 10 ms max.
(using OUTEN) (PWRGD transitioning high)
OUTEN, VID and LL signal valid states:
ON or Logic ‘1’ 0.8 Vdc min., 5.5 Vdc max.
OFF or Logic ‘0’ -0.3 Vdc min., 0.4 Vdc max.
VRM10 Series
Single output
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 80 A/85 A Non-Isolated 2
NEW Product
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.02 Holes ±0.005
3 Places ±0.010 Angles ±2Degrees
Third Angle Projections
0.065 (1.65)
Ref THK
0.46
(11.6) Ref
2.85
(72.4) Ref.
1
62 32
31
0.248 (6.30) Max
Comp HT
0.915
(23.24)
C
L
C
L
30 EQ Spaces
@ 0.100 ±0.002 (2.54 ±0.05)
each Equals 3.000 (76.20)
TOL Non-Accum
0.093
(2.36)
0.543
(13.79)
0.300 (7.62)
KEY SLOTS
0.500
(12.70)
0.042 Typ
(1.07) ±0.002 0.050
(1.27)
32
62
0.200 (5.08)
0.700
(17.78)
R0.079
(R2.00) (2Pls)
0.039 (1.00)
0.17 (4.3) Ref
3.186 (80.92) ±0.002
0.17 (4.3) Ref
0.62
(15.7) Ref
1.240
(31.50) Ref
MATING CONNECTOR
Tyco/Amp #1489930-2
Foxconn # 2EV04607-NW
Figure1: Mechanical Drawing
PIN CONNECTIONS
PIN NO. FUNCTION PIN NO. FUNCTION
1 Vin+ 62 Vin-
2 Vin+ 61 Vin-
3 Vin+ 60 Vin-
4 Vin+ 59 Vin-
5 N/U 58 VRM_pres#
6 VID4 57 Key
7 VID3 56 VID2
8 VID1 55 VID0
9 OVP 54 VID5
10 PWRGD 53 Outen
11 Vosen- 52 Vosen+
12 LL0 (9) 51 LL1 (9)
13 Vo- 50 Vo+
14 Vo+ 49 Vo+
15 Vo- 48 Vo-
16 Vo+ 47 Vo+
17 Vo- 46 Vo-
18 Vo+ 45 Vo+
19 Vo- 44 Vo-
20 Vo+ 43 Vo+
21 Vo- 42 Vo-
22 Vo+ 41 Vo+
23 Vo- 40 Vo-
24 Vo+ 39 Vo+
25 Vo- 38 Vo-
26 Vo+ 37 Vo+
27 Vo- 36 Vo-
28 Vo+ 35 Vo+
29 Vo- 34 Vo-
30 Vo+ 33 Vo+
31 Vo- 32 Vo-
Table 1: LL0, LL1 Load Line Codes
Table 2: Pin Connections
MODEL LL0 LL1 LOAD LINE SLOPE, Rout UNITS
VRM10-85-12-UY 0 0 1.25 m
VRM10-85-12-UY 0 1 1.25 m
VRM10-85-12-UY 1 0 1.25 m
VRM10-85-12-UY 1 1 Reserved m
VRM10-80-12-PY N/A N/A 1.24 m
INPUT OUTPUT
OUTPUT OUTPUT OUTPUT
EFFICIENCY REGULATION MODEL
VOLTAGE VOLTAGE
OVP (8) CURRENT CURRENT CURRENT
(TYP.) LOAD NUMBER (11,12)
(MIN) (MAX.) (MAX.)
CONTINUOUS NON-SUSTAINED
12 Vdc 0.8375-1.6000 Vdc 1.8 V 0 A 85 A 100 A 85% See Table 1 VRM10-85-12-UY
12 Vdc 0.8375-1.6000 Vdc 1.8 V 0 A 80 A 91 A 85% 1.24mV/A VRM10-80-12-PY
VRM10 Series
Single output
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 80 A/85 A Non-Isolated 3
NEW Product
VOLTAGE IDENTIFICATION (VID) CODES
VID4 VID3 VID2 VID1 VID0 VID5 VID (V)
0 1 0 1 0 0 0.8375
0 1 0 0 1 1 0.8500
01 0 0 1 0 0.8625
0 1 0 0 0 1 0.8750
0 1 0 0 0 0 0.8875
0 0 1 1 1 1 0.9000
00 1 1 1 0 0.9125
0 0 1 1 0 1 0.9250
0 0 1 1 0 0 0.9375
0 0 1 0 1 1 0.9500
0 0 1 0 1 0 0.9625
0 0 1 0 0 1 0.9750
0 0 1 0 0 0 0.9875
0 0 0 1 1 1 1.0000
0 0 0 1 1 0 1.0125
0 0 0 1 0 1 1.0250
0 0 0 1 0 0 1.0375
0 0 0 0 1 1 1.0500
0 0 0 0 1 0 1.0625
0 0 0 0 0 1 1.0750
0 0 0 0 0 0 1.0875
11 1111OFF
1 1 1110OFF
111101 1.1000
111 1 0 0 1.1125
1 1 1 0 1 1 1.1250
1 1 1 0 1 0 1.1375
1 1 1 0 0 1 1.1500
1 1 1 0 0 0 1.1625
1 1 0 1 1 1 1.1750
110110 1.1875
1 1 0 1 0 1 1.2000
VOLTAGE IDENTIFICATION (VID) CODES (CONTD.)
VID4 VID3 VID2 VID1 VID0 VID5 VID (V)
1 1 0 1 0 0 1.2125
1 1 0 0 1 1 1.2250
11 0 0 1 0 1.2375
1 1 0 0 0 1 1.2500
1 1 0 0 0 0 1.2625
1 0 1 1 1 1 1.2750
10 1 1 1 0 1.2875
1 0 1 1 0 1 1.3000
1 0 1 1 0 0 1.3125
1 0 1 0 1 1 1.3250
1 0 1 0 1 0 1.3375
1 0 1 0 0 1 1.3500
1 0 1 0 0 0 1.3625
1 0 0 1 1 1 1.3750
1 0 0 1 1 0 1.3875
1 0 0 1 0 1 1.4000
1 0 0 1 0 0 1.4125
1 0 0 0 1 1 1.4250
1 0 0 0 1 0 1.4375
1 0 0 0 0 1 1.4500
1 0 0 0 0 0 1.4625
0 1 1 1 1 1 1.4750
0 1 1 1 1 0 1.4875
011101 1.5000
011 1 0 0 1.5125
0 1 1 0 1 1 1.5250
0 1 1 0 1 0 1.5375
0 1 1 0 0 1 1.5500
0 1 1 0 0 0 1.5625
0 1 0 1 1 1 1.5750
010110 1.5875
0 1 0 1 0 1 1.6000
Table 3: Voltage Identification Codes
VRM10 Series
Single output
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 80 A/85 A Non-Isolated 4
NEW Product
SIGNAL ELECTRICAL INTERFACE
ELECTROMAGNETIC COMPATIBILITY
NNootteess
1Recommended output capacitance, 12 x 560 µF aluminium polymer and
44 x 10 µF MLCC for slew rates up to 430 A/µs, 14 x 560 µF aluminum
polymer and 45 x 10 µF MLCC for slew rates up to 930 A/µs.
28 mV pk-pk ripple. Vin = 12 V, Vout = 1.35 V, Iout = 85 A.
3With the recommended capacitors (See Note 1) across the output, the
output voltage stays within the load regulation window for all loads and
transient events, up to 100 A for the VRM10-85-12-UY (91 A for the
VRM10-80-12-PY) over a 20 MHz bandwidth, 0 ºC < Tamb < 60 ºC.
4VRM10 uses a four phase buck topology. Each phase switches at
550 KHz. This gives an equivalent switching frequency of 2.2 MHz
5Recommended input fusing: one 20 A (or two 10 A in parallel) very fast
acting fuse(s). The VRM10 is a high current device. Use appropriate
care in handling and installation of this device, which is intended only for
use within enclosed equipment.
60.01 G2/Hz from 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to
500 Hz, all axes.
7Maximum current requires adequate forced air over the converter. Please
consult Figures 2 and 3 for thermal de-rating.
8When the VRM detects an output over-voltage event, the OVP pin
transitions to logic high. This signal can be used to shut down the
supply to the VRM, or drive a crowbar device.
9Pins 12 and 51 are not connected on VRM10-80-12-PY
. On VRM10-85-
12-UY, do not leave these pins floating.
10 When included in the users system ESD event shall cause no out-of-
regulation conditions.
11 The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free)
compliant. Pb-free (RoHS 6/6) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
CHARACTERISTIC - SIGNAL NAME SYMBOL MIN TYP MAX UNITS NOTES AND CONDITIONS
ESD - operating 15 kV IEC61000-4-2
(See Note 10) In end user equipment
ESD - non-operating 25 kV IEC61000-4-2
In end user equipment
Radiated emissions B Class FCC and EN55022
In end user equipment
Input characteristics:
Input current - operating IIN 10.7 A Vin = Vin (typ.),
Iout (cont.) = 85 A, VID = 1.325 V
Input capacitance - external bypass CINext 680 1000 µF
CHARACTERISTIC - SIGNAL NAME SYMBOL MIN TYP MAX UNITS NOTES AND CONDITIONS
OUTEN - on VOUTEN (on) 0.8 5.5 V No pull up resistor provided by the
VRM
OUTEN - off VOUTEN (off) -0.3 0.4 V No pull up resistor provided by the
VRM
OUTEN - leakage current -1 1 µA
PWRGD - low VPWRGD (low) 0.4 V Sink current 4 mA
PWRGD - sink current IPWRGD (sink) 4 mA Open-collector output to not more
than 5.5 V
PWRGD - low threshold 72 74 76 % Percentage of VID code setting
PWRGD - turn-on response to Trise 0 4 10 ms For waveforms, refer to Application
OUTEN going high Note 171
VID - high Vih (VID) 0.8 5.5 V
VID - low Vil (VID) -0.3 0.4 V
VID - pull up current I (VID) 35 50 65 µA
OVP signal trip point R (VID) 1.7 VID + 0.2 V
OVP drive voltage 1.9 (5.5) V Iovp = -100 mA (Iovp = -1 mA)
LL - high Vih (LL) 0.8 5.5 V VRM10-85-12-UY only
LL - low Vil (LL) -0.3 0.4 V VRM10-85-12-UY only
LL - input impedance Zi (LL) 2.18 2.21 kVRM10-85-12-UY only
VRM10 Series
Single output
Filename: vrm10_u_p.pdf Rev (02): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 80 A/85 A Non-Isolated 5
NEW Product
Figure 3: Thermal Derating Curve for VRM10-80-12-PY
(See Note A)
Figure 5: Typical Efficiency Vs Load (See Note C)
CONTINUOUS OUTPUT CURRENT (A)
AMBIENT TEMPERATURE (ºC)
60
65
70
75
80
25 30 35 40 45 50 55 60
300 LFM
400 LFM
400 LFM
500 LFM
500 LFM
600 LFM
600 LFM
VID 1.4V
VID > 1.4V
EFFICIENCY (%)
OUTPUT CURRENT (A)
Vin = 11.0V
Vin = 12.0V
Vin = 12.6V
80
81
82
83
84
85
86
87
88
89
90
0 20 40 60 80 100
Figure 2: Thermal Derating Curve for VRM10-85-12-UY
(See Note A)
Figure 4: Load Regulation (See Notes 3 and B)
CONTINUOUS OUTPUT CURRENT (A)
AMBIENT TEMPERATURE (ºC)
60
65
70
75
80
25 30 35 40 45 50 55 60
85
300 LFM
400 LFM
400 LFM
500 LFM
500 LFM
600 LFM
600 LFM
VID 1.4V
VID > 1.4V
OUTPUT VOLTAGE (V)
OUTPUT CURRENT (A)
Max.
11.0Vin
12.6Vin
12.0Vin
Min.
VID-0.04
VID
0 20 40 60 80 100 120
VID-LL x 0.04
VID - 0.04
Vout
Vo min. = VID - Rout * Iout - Vwindow
Vo max. = VID - Rout * Iout
Figure 6: Short Circuit and Over Current Protection (See Note D)
OUTPUT VOLTAGE (V)
OUTPUT CURRENT (A)
Vin = 11.0V
Vin = 12.0V
Vin = 12.6V
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 20 40 60 80 100 120 140
1.6
NNootteess
AFor the LFM and VID conditions graphed, there is no derating between
0 ºC and 25 ºC.
BFor load regulation equations: VID is in Volts, programmed by the VID bits
(refer to Table 3); Rout is in s, programmed by the LL bits (refer to Table
1); and the output current, Iout is in amps. VWindow is 0.040 for VRM10-
85-12-UY and 0.038 for VRM10-80-12-PY.
CEfficiency Vs load plotted is representative of a typical VRM10-85-12-UY
with VID = 1.4V, LL0 = 0, LL1 = 1.
DShown for a VRM10-80-12-PY with VID = 1.4 V.
Please consult our website for the following items: 4 Application Note www.artesyn.com
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.