http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THL 6WI Series 6 Watt
Input Specifications
Input current at no load (nominal input voltage) 24 Vin models: 30 mA typ.
48 Vin models: 20 mA typ.
Input current at full load (nominal input voltage) 24 Vin; 3.3 VDC model: 260 mA typ.
24 Vin other models: 300 mA typ.
48 Vin; 3.3 VDC model: 130 mA typ.
48 Vin other models: 150 mA typ.
Surge voltage (100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise EN 55022 level A, FCC part 15, level A without
external components
Recommended input fuse (slow blow) 24 V models: 1500 mA
48 V models: 750 mA
Output Specifications
Voltage set accuracy ±2 % max
Regulation – Input variation Vin min. to Vin max. 1.0 % max.
– Load variation 15 – 100 % 1.2 % max.
Minimum load 15 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experienced)
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz bandwidth) 100 mVp-p max.
Transient response setting time (25 % load step change) 300 µs typ.
Short circuit protection indefinite
Maximum capacitive load 3.3 & 5 VDC models: 330 µF
12, 15 & 24 VDC models: 100 µF
±5,±12 & ±15 VDC models: 100 µF (each output)
General Specifications
Temperature – Operating –40°C to +75°C
– Storage –40°C to +125°C
– Case +105°C max.
Load derating 3 %/K above 60°C
Humidity (non condensing) 95 %
Reliability, calculated MTTF (MIL-HDBK-217F, at +25°C, ground benign) >350‘000 h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC
Isolation capacitance – Input/Output 1500 pF max.
Isolation resistance – Input/Output (500 VDC) >1 GOhm
Safety standard (designed to meet) IEC 60950-1, UL 60950-1
Safety approvals – CB test certificate according IEC 60950-1 www.tracopower.com/products/thl6wi-cb.pdf
– CSA certificate fo UL/cUL 60950-1 www.tracopower.com/products/thl6wi-csa.pdf
Switching frequency 330 kHz
Altitude during operation 5‘000 m max. (16‘40 0 f t ) approved
Remote On/Off – On: 2.5 to 50 VDC or open circuit
– Off: –0.7 to +0.8 VDC
– Off stand by input current 10 mA max.
Environmental compliance – Reach www.tracopower.com/products/thl6wi-reach.pdf
– RoHS RoHS directive 2002/95/EC
pending