1
FN7464.6
ISL29003
Light-to-Digital Output Sensor with High
Sensitivity, Gain Selection, Interrupt
Function and I2C Interface
The ISL29003 is an integrated light sensors with a 16-bit
integrating type ADC, I2C user programmable lux range
select for optimized counts/lux, and I2C multi-function control
and monitoring capabilities. The internal ADC provides 16-bit
resolution while rejecting 50Hz and 60Hz flicker caused by
artificial light sources.
In normal operation, power consumption is less than 300µA.
Furthermore, an av ailable software power-down mode
controlled via the I2C interface reduces powe r consumption
to less than 1µA.
The ISL29003 supports a hardware interrupt that remains
asserted low until the host clears it through I2C interface.
Designed to operate on su pplies from 2.5V to 3.3V, the
ISL29003 is specified for operation over the -40°C to +85°C
ambient temperature range.
Pinout ISL29003
(6 LD ODFN)
TOP VIEW
Features
Range select via I2C
- Range 1 = 0 lux to 1000 lux
- Range 2 = 0 lux to 4000 lux
- Range 3 = 0 lux to 16,000 lux
- Range 4 = 0 lux to 64,000 lux
Human eye response (540nm peak sensitivity)
Temperature compensated
16-bit re sol u ti o n
Adjustable resolution: up to 65 counts per lux
User-programmable upper and lower threshold interrupt
Simple output code, directly proportional to lux
IR + UV rejection
50Hz/60Hz rejection
2.5V to 3.3V supply
6 Ld ODFN (2.1mmx2mm)
Pb-free (RoHS compliant)
Applications
Ambient light sensing
Backlight control
Temperature control systems
Contrast control
Camera light meters
Lightin g controls
Block Diagram
Ordering Information
PART NUMBER
(Notes 1, 2, 3) PACKAGE
(Pb-free) PKG. DWG. #
ISL29003IROZ (Note 4) 6 Ld ODFN L6.2x2.1
ISL29003IROZ-T7 6 Ld ODFN L6.2x2.1
ISL29003IROZ-EVAL Evaluation Board
NOTES:
1. Please refer to TB347 for details on reel specifications.
2. These Intersil Pb-free plastic packaged products employ special
Pb-free material sets; molding compounds/die attach materials
and 100% matte tin plate - e3 termination finish, which is RoHS
compliant and compatible with both SnPb and Pb-free soldering
operations. Intersil Pb-free products are MSL classified at
Pb-free peak reflow temperatures that meet or exceed the
Pb-free requirements of IPC/JEDEC J STD-020.
3. For Moisture Sensitivity Level (MSL), please see device
information page for ISL29003. For more information on MSL
please see tech brief TB466.
4. Not recommended for new designs.
1
2
3
6
5
4
VDD
GND
REXT
SDA
SCL
INT
THERMAL
PAD
VDD
REXT GND
SDA
SCL
COMMAND
REGISTER
INTEGRATING
ADC DATA
REGISTER
I2C
PHOTODIODE 1
PHOTODIODE 2
MUX
3 2
5
6
1
FOSC
IREF
COUNTER
216
MODE
GAIN/RANGE
EXT
SHDN
INT TIME
4INT
INTERRUPT
ISL29003
TIMING
INT
Data Sheet November 17, 2011
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 |Copyright Intersil Americas LLC 2006-2008, 2011. All Rights Reserved
I2C Bus is a registered trademark owned by NXP Semiconductors Netherlands, B.V
Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.
2FN7464.6
November 17, 2011
Absolute Maximum Ratings (TA = +25°C) Thermal Information
VDD Supply Voltage between VDD and GND . . . . . . . . . . . . . 3.6V
I2C Bus Pin Voltage (SCL, SDA) . . . . . . . . . . . . . . . . . -0.2V to 5.5V
I2C Bus Pin Current (SCL, SDA) . . . . . . . . . . . . . . . . . . . . . . <10mA
INT, REXT Pin Voltage . . . . . . . . . . . . . . . . . . . . . . . . . -0.2V to VDD
ESD Rating
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2kV
Thermal Resistance (Typical, Note 5) θJA (°C/W)
6 Ld ODFN Package . . . . . . . . . . . . . . . . . . . . . . . . 88
Maximum Die Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .+90°C
Storage Temperature. . . . . . . . . . . . . . . . . . . . . . . .-40°C to +100°C
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
5. θJA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief TB379.
IMPORTANT NOTE: All parameters having Min/Max specifications are guaranteed. Typical values are for information purposes only. Unless otherwise noted, all tests
are at the specified temperature and are pulsed tests, therefore: TJ = TC = TA
Electrical Specifications VDD = 3V, TA = +25°C, REXT = 100kΩ 1% tolerance, unless otherwise s pecified, Internal Timing Mode
operation (See “Principles of Operation” on page 3).
PARAMETER DESCRIPTION CONDITION MIN
(Note 8) TYP MAX
(Note 8) UNIT
VDD Power Supply Range 2.25 3.3 V
IDD Supply Current 0.29 0.33 mA
IDD1 Supply Current Disabled Software disabled 0.1 1 µA
fOSC1 Internal Oscillator Frequency Gain/Range = 1 or 2 290 327 360 kHz
fOSC2 Internal Oscillator Frequency Gain/Range = 3 or 4 580 655 720 kHz
FI2CI
2C Clock Rate 1 400 kHz
DATA0 Diode1 Dark ADC Code E = 0 lux, Mode1, Gain/Range = 1 5 Counts
DATA1 Full Scale ADC Code 65535 Counts
DATA2 Diode1 ADC Code Gain/Range = 1 Accuracy Mode1 E = 300 lux, fluorescent light,
Gain/Range = 1
(Note 6)
15760 20200 24440 Counts
DA T A3 Diode2 ADC Code Gain/Range = 1 Accuracy Mode2 2020 Counts
DATA4 Diode1 ADC Code Gain/Range = 2 Accuracy Mode1 E = 300 lux, fluorescent light,
Gain/Range = 2
(Note 6)
5050 Counts
DA T A5 Diode2 ADC Code Gain/Range = 2 Accuracy Mode2 505 Counts
DATA6 Diode1 ADC Code Gain/Range = 3 Accuracy Mode1 E = 300 lux, fluorescent light,
Gain/Range = 3
(Note 6)
1262 Counts
DA T A5 Diode2 ADC Code Gain/Range = 3 Accuracy Mode2 126 Counts
DATA6 Diode1 ADC Code Gain/Range = 4 Accuracy Mode1 E = 300 lux, fluorescent light,
Gain/Range = 4
(Note 6)
316 Counts
DA T A6 Diode2 ADC Code Gain/Range = 4 Accuracy Mode2 32 Count s
VREF Voltage of REXT Pin 0.485 0.51 0.535 V
VTL SCL and SDA Threshold LO (Note 7) 1.05 V
VTH SCL and SDA Threshold HI (Note 7) 1.95 V
ISDA SDA Current Sinking Capability 3 5 mA
IINT INT Current Sinking Capability 3 5 mA
NOTES:
6. Fluorescent light is substituted by a green (λ = 540nm) LED during production.
7. The voltage threshold levels of the SDA and SCL pins are VDD dependent: VTL = 0.35*VDD. VTH = 0.65*VDD
8. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
ISL29003
3FN7464.6
November 17, 2011
Principles of Operation
Photodiodes
The ISL29003 contains two photodiodes. Diod e1 is sensitive
to both visible and infrared light, whi le Diode2 is mostly
sensitive to infrared light. The spectral response of th e two
diodes are independent from one another. See Figure 7
Spectral Response vs Wavelength in the performance curves
section. The photodiodes convert light to current. Then, the
diodes’ current output s a re converted to digi t al by a single
built-in integrating type 16-bit Analog-to-Dig it al Co nverter
(ADC). An I2C command mode determines which photodiode
will be converted to a digital signa l. Mode1 is Dio de1 onl y.
Mode2 is Diode2 only. Mode3 is a sequential Mode1 and
Mode2 with an internal subtract function (Diode1 - Diode2).
Analog-to-Digital Converter (ADC)
The converter is a charge-balancing integrating type 16-bit
ADC. The chosen method for conversion is best for
converting small current signals in the presence of AC
periodic noise. A 100ms integration time, for instance, highly
rejects 50Hz and 60Hz power line noise simultaneously. See
“Integration Time or Conversion T ime” on page 8 and “Noise
Rejection” on page 9.
The built-in ADC offers the user flexibility in integration time or
conversion time. T wo timing modes are available; Internal
T iming Mode and External Timing Mode. In Internal Timing
Mode, integration time is determined by an internal dual speed
oscillator (fOSC), and the n-bit (n = 4, 8, 12,16) counter inside
the ADC. In External T iming Mode, integration time is
determined by the time between two consecutive I2C External
T iming Mode commands. See “External T iming Mode” on
page 7. A good balancing act of integration time and resolution
depending on the application is required for optimal results.
The ADC has four I2C programmable range select to
dynamically accommodate various lighting conditions. For
very dim conditions, the ADC can be configured at its lowest
range. For very bright conditions, the ADC can be configured
at its highest range.
Interrupt Function
The active low interrupt pin is an open dr ain pull-down
configuration. The interrupt pin serves as an alarm or
monitoring function to determine whether the ambient light
exceeds the upper threshold or goes below the lower
threshold. The user can also configure the persistency of the
interrupt pin. This eliminates any false triggers, such as
noise or sudden spikes in ambient light conditions. An
unexpected camera flash, for example, can be ignored by
setting the persistency to 8 integration cycles.
I2C Interface
There are eight (8) 8-bit registers available inside the ISL29003.
The command and control registers define the operation of the
device. The command and control registers do not change until
the registers are overwritten.There are two 8-bit registers that
set the high and lo w interrupt thresholds . There are fo ur 8-bit
data Read Only registers; two bytes for the sensor reading and
another two bytes for the timer counts. The data registers
contain the ADC's latest digital output, and the number of clock
cycles in the previous integration period.
The ISL29003’s I2C interface slave address is hardwired
internally as 1000100. Wh en 1000100x with x as R or W is
sent after the Start condition, this device compares the first
seven bits of this byte to its address and matches.
Figure 1 shows a sample one-byte read. Figure 2 shows a
sample one-byte write. Figure 3 shows a sync_iic timing
diagram sample for externally controlled inte gration time.
The I2C bus master always drives the SCL (clock) line, while
either the master or the slave can drive the SDA (data) line.
Figure 2 shows a sample write. Every I2C transaction begins
with the master asserting a start condition (SDA falling while
SCL remains high). The following byte is driven by the
master and includes the slave address and read/write bit.
The receiving device is responsible for pulling SDA low
during the acknowledgement period.
Every I2C transaction ends with the master asserting a stop
condition (SDA rising while SCL remains high).
For more information about the I2C standard, please consult
the Philips® I2C specification documents.
Pin Descriptions
PIN NUMBER PIN NAME DESCRIPTION
1 VDD Positive supply; connect this pin to a regulated 2.5V to 3.3V supply
2 GND Ground pin. The thermal pad is connected to the GND pin
3 REXT External resistor pin for ADC reference; connect this pin to ground through a (nominal) 100kΩ resistor
4INT
Interrupt pin; LO for interrupt/alarming. The INT pin is an open drain.
5SCLI
2C serial clock The I2C bus lines can be pulled above VDD, 5.5V max.
6SDAI
2C serial data
ISL29003
4FN7464.6
November 17, 2011
FIGURE 1. I2C READ TIMING DIAGRAM SAMPLE
Start WAA AA
A6 A5 A4 A3 A2 A1 A0 W A R7 R6 R5 R4 R3 R2 R1 R0 A A6 A5 A4 A3 A2 A1 A0 W A
A A A D7D6D5D4D3D2D1D0 A
123456789123456789 123456789123456789
STOP
STOP START
SDA DRIVEN BY MASTER
DEVICE ADDRESS
SDA DRIVEN BY ISL29003
DATA BYTE0
NAK
REGISTER ADDRESS
I2C SDA
Out
DEVICE ADDRESS
I2C DATA
SDA DRIVEN BY MASTER
I2C CLK
I2C SDA
In
SDA DRIVEN BY MASTER
FIGURE 2. I2C WRITE TIMING DIAGRAM SAMPLE
Start
W
AAA
A6 A5 A4 A3 A2 A1 A0
W
A R7 R6 R5 R4 R3 R2 R1 R0 A B7 B6 B5 B4 B3 B2 B1 B0 A
AAA
123456789123456789123456789
STOP
I2C SDA In
I2C CLK In
SDA DRIVEN BY MASTER
FUNCTIONSREGISTER ADDRESS
I2C SDA Out
DE VICE ADDRE SS
I2C DATA
SDA DRIVEN BY MASTER SDA DRIVEN BY MASTER
FIGURE 3. I2C sync_iic TIMING DIAGRAM SAMPLE
Start
W
AAStop
A6 A5 A4 A3 A2 A1 A0
W
A R7R6R5R4R3R2R1R0 A
AA
123456789123456789
REGIS TE R ADDRESS
S DA DRIVEN BY MASTER
I2C SDA O ut
DE V ICE A DDRE S S
I2C DATA
I2C SDA In
I2C CLK In
SDA DRIVEN BY MASTER
ISL29003
5FN7464.6
November 17, 2011
Register Set
There are eight registers that are available in th e ISL29003. Table 1 summarizes the available registers and their functions.
TABLE 1. REGISTER SET
ADDR
(HEX) REGISTER
NAME BIT(S) FUNCTION NAME FUNCTIONS/DESCRIPTION
00 Command 7 Enable 0: disable ADC-core
1: enable ADC-core
6 ADCPD 0: Normal operation
1: Power-down Mode
5 Timing_Mode 0: Integration is internally timed
1: Integration is externally sync/controlled by I2C host
4Reserved
3:2 Mode<1:0> Selects ADC work mode
0: Diode1’s current to unsigned 16-bit data
1: Diode2’s current to unsigned 16-bit data
2: Difference between diodes (I1 - I2) to signed 15-bit data
3: reserved
1:0 Width<1:0> Number of clock cycles; n-bit resolution
0: 216 cycles
1: 212 cycles
2: 28 cycles
3: 24 cycles
01 Control 7 Ext_Mode Always set to logic 0. Factory use only.
6 Test_Mode Always set to logic 0
5 Int_Flag 0: Interrupt is cleared or not yet triggered
1: Interrupt is triggered
4 Reserved Always set to logic 0. Factory use only.
3:2 Gain<1:0> Selects the gain so range is
0: 0 to 1000 lux
1: 0 to 4000 lux
2: 0 to 16000 lux
3: 0 to 64000 lux
1:0 Int_Persist
<1:0> Interrupt is triggered after
0: 1 integration cycle
1: 4 integration cycles
2: 8 integration cycles
3: 16 integration cycles
02 Interrupt Threshold
HI 7:0 Interrupt Threshold
HI High byte of HI interrupt threshold. Default is 0xFF
03 Interrupt Threshold
LO 7:0 Interrupt Threshold
LO High byte of the LO interrupt threshold. Default is 0x00
04 LSB_Sensor 7:0 LSB_Sensor Read-Only data register that contains the least significant byte of the
latest sensor reading.
05 MSB_Sensor 7:0 MSB_Sensor Read-Only data register that contains the most significant byte of the
latest sensor reading.
06 LSB_Timer 7:0 LSB_Timer Read-Only data register that contains the least significant byte of the
timer counter value corresponding to the latest sensor reading.
07 MSB_Timer 7:0 MSB_Timer Read-Only data register that contains the most significant byte of the
timer counter value corresponding to the latest sensor reading.
ISL29003
6FN7464.6
November 17, 2011
Command Register 00(hex)
The Read/Write command register has five functions:
1. Enable; Bit 7. This function either resets the ADC or
enables the ADC in normal operation. A logic 0 disables
ADC to reset-mode. A logic 1 enables adc to normal
operation.
2. ADCPD; Bit 6. This function puts the device in a
power-down mode. A logic 0 puts the device in normal
operation. A logic 1 power s down the device.
For proper shut down operation, it is recommended to
disable ADC first then disable the chip. Specifically, the user
should first send I2C command with Bit 7 = 0 and then send
I2C command with Bit 6 = 1.
3. Timing Mode; Bit 5. This function determines whether the
integration time is done internally or externally . In Internal
Timing Mode, integration time is determined by an
internal dual speed oscillator (fOSC), and the n-bit (n = 4,
8, 12,16) counter inside the ADC. In External Timing
Mode, integration time is determined by the time between
two consecutive external-sync sync_iic pulse commands.
4. Photodiode Select Mode; Bits 3 and 2. This function
controls the mux attached to the two photodiodes. At
Mode1, the mux directs the current of Diode1 to the ADC.
At Mode2, the mux directs the current of Diode2 only to
the ADC. Mode3 is a sequential Mode1 and Mode2 with
an internal subtract function (Diode1 - Diode 2).
*n = 4, 8, 12,16 depending on the number of clock cycles
function.
5. Width; Bits 1 and 0. This function determines the number
of clock cycles per conversion. Changing the number of
clock cycles does more than just change the resolution of
the device; it also changes the integration time, which is
the period the device’s analog-to-digital (A/D) converter
samples the photodiode current signal for a lux
measurement.
Control Register 01(he x)
The Read/Write control register has three functions:
1. Interrupt flag; Bit 5. This is the status bit of the interrupt.
The bit is set to logic high when the interrupt threshold s
have been triggered, and logic low whe n not yet
triggered. Writing a logic low clears/resets the status bit.
2. Range/Gain; Bits 3 and 2. The Full Scale Range can be
adjusted by an external resistor REXT and/or it can be
adjusted via I2C using the Gain/Range function.
Gain/Range has four possible values, Range(k) where k
is 1 through 4. Tabl e 9 lists the possible values of
Range(k) and the resulting FSR for some typical value
REXT resistors.
TABLE 2. WRITE ONLY REGISTERS
ADDRESS REGISTER
NAME FUNCTIONS/
DESCRIPTION
b1xxx_xxxx sync_iic Writing a logic 1 to this address bit
ends the current ADC-integration
and starts another. Used only with
External Timing Mode.
bx1xx_xxxx clar_int Writing a logic 1 to this address bit
clears the interrupt.
TABLE 3. ENABLE
BIT 7 OPERATION
0 Disable ADC-Core to Reset-Mode (default)
1 Enable ADC-Core to Normal Operation
TABLE 4. ADCPD
BIT 6 OPERATION
0 Normal Operation (default)
1 Power-Down
TABLE 5. TIMING MODE
BIT 5 OPERATION
0 Internal Timing Mode. Integration time is internally
timed determined by fOSC, REXT, and number of
clock cycles.
1 External Timing Mode. Integration time is externally
timed by the I2C host.
TABLE 6. PHOTODIODE SELECT MODE; BITS 2 AND 3
BITS 3:2 MODE
0:0 MODE1. ADC integrates or converts Diode1 only.
Current is converted to an n-bit unsigned data.*
0:1 MODE2. ADC integrates or coverts Diode2 only.
Current is converted to an n-bit unsigned data.*
1:0 MODE3. A sequential MODE1 then MODE2
operation. The difference current is an (n-1) signed
data.*
1:1 No Operation.
TABLE 7. WIDTH
BITS 1:0 NUMBER OF CLOCK CYCLES
0:0 216 = 65,536
0:1 212 = 4,096
1:0 28 = 256
1:1 24 = 16
TABLE 8. INTERRUPT FLAG
BIT 5 OPERATION
0 Interrupt is cleared or not triggered yet
1 Interrupt is triggered
ISL29003
7FN7464.6
November 17, 2011
3. Interrupt persist; Bits 1 and 0. The interrupt pin and th e
interrupt flag is triggered/set when the data sensor
reading is out of the interrupt threshold window after m
consecutive number of integration cycles. The interrupt
persist bits determine m.
Interrupt Threshold HI Register 02(hex)
This register sets the HI threshold for the interrupt pin and
the interrupt flag. By default, the Interrupt threshold HI is
FF(hex). The 8-bit data written to the register represents the
upper MSB of a 16-bit value. The LSB is always 00(hex).
Interrupt Threshold LO Register 03(hex)
This register sets the LO threshold for the interrupt pin and
the interrupt flag. By default, the Interru pt threshold LO is
00(hex). The 8-bit data written to the register represents the
upper MSB of a 16-bit value. The LSB is always 00(hex).
Sensor Data Register 04(hex) and 05(hex)
When the device is configured to output a 16-bit data, the
least significant byte is accessed at 04 (hex), and the most
significant byte can be accessed at 05(hex). The sensor data
register is refreshed after every integration cycle.
Timer Data Register 06(hex) and 07(hex)
Note that the timer counter value is only available when
using the External Timing Mode. The 06(hex) and 07(hex)
are the LSB and MSB respectively of a 16-bit timer counter
value corresponding to the most recent sensor reading.
Each clock cycle increments the counter. At the end of each
integration period, the value of this counter is made available
over the I2C. This value can be used to eliminate noise
introduced by slight timing errors caused by imprecise
external timing. Microcontrollers, for example, often cannot
provide high-accuracy command-to-command timing , and
the timer counter value can be used to eliminate the
resulting noise.
Calculating Lux
The ISL29003’s output codes, DATA, are directly
proportional to lux.
The proportionality constant α is determined by the Full
Scale Range, FSR, and the n-bit ADC, which is user defined
in the command register. The proportionality constant can
also be viewed as the resolution; The smallest lux
measurement the device can measure is α.
Full Scale Range, FSR, is determined by the software
programmable Range/Gain, Range(k), in the command
register and an external scaling resistor REXT which is
referenced to 100kΩ.
The transfer function effectively for each timing mode
becomes:
INTERNAL TIMING MODE
EXTERNAL TIMING MODE
n = 4, 8, 12, or 16. This is the number of clock cycles
programmed in the command register.
Range(k) is the user defined range in the Gain/Range bit in
the command register.
REXT is an external scaling resistor hardwired to the REXT
pin.
DATA is the output sensor reading in number of counts
available at the data register.
2n represents the maximum number of counts possible in
Internal Timing Mode. For the External Timing Mode, the
maximum number of counts is stored in the data register
named COUNTER.
TABLE 9. RANGE/GAIN TYPICAL FSR LUX RANGES
BITS
3:2 k RANGE (k)
FSR LUX
RANGE@
REXT = 100k
FSR LUX
RANGE@
REXT = 50k
FSR LUX
RANGE@
REXT = 500k
0:0 1 973 973 1946 195
0:1 2 3892 3892 7784 778
1:0 3 15,568 15,568 31,136 3114
1:1 4 62,272 62,272 124,544 12,454
TABLE 10. INTERRUPT PERSIST
BITS 1:0 NUMBER OF INTEGRATION CYCLES
0:0 1
0:1 4
1:0 8
1:1 16
TABLE 11. DATA REGISTERS
ADDRESS
(hex) CONTENTS
04 Least-significant byte of most recent sensor reading.
05 Most-significant byte of most recent sensor reading.
06 Least-significant byte of timer counter value
corresponding to most recent sensor reading.
07 Most-significant byte of timer counter value
corresponding to most recent sensor reading.
EαDATA×=(EQ. 1)
αFSR
2n
------------
=(EQ. 2)
(EQ. 3)
FSR Range k() 100kΩ
REXT
------------------
×=
(EQ. 4)
ERange k() 100kΩ
REXT
------------------
×
2n
---------------------------------------------------- DATA×=
(EQ. 5)
ERange k() 100kΩ
REXT
------------------
×
COUNTER
---------------------------------------------------- DATA×=
ISL29003
8FN7464.6
November 17, 2011
COUNTER is the number increments accrued for between
integration time for External Timing Mode.
Gain/Range, Range (k)
The Gain/Range can be programmed in the control register
to give Range (k) determining the FSR. Note that Range (k)
is not the FSR (see Equation 3). Range(k) provides four
constants depending on programmed k that will be scaled by
REXT (see Table 9). Unlike REXT, Range(k) dynamically
adjusts the FSR. This function is especially useful when light
conditions are varying drastically while maintaining excellent
resolution.
Number of Clock Cycles, n-bit ADC
The number of clock cycles determines “n” in the n-bit ADC; 2n
clock cycles is a n-bit ADC. n is programmable in the command
register in the width function. Depending on the application, a
good balance of speed and resolution has to be considered
when deciding for n. For fast and quick measurement, choose
the smallest n = 4. For maximum resolution without regard of
time, choose n = 16. Table 12 compares the trade-off between
integration time and resolution. See Equations 10 and 1 1 for the
relation between integration time and n. See Equation 3 for the
relation of n and resolution.
External Scaling Resistor REXT and fosc
The ISL29003 uses an external resistor REXT to fix its
internal oscillator frequency, fOSC. Consequently, REXT
determines the fOSC, integration time and the FSR of the
device. fOSC, a dual speed mode oscillator, is inversely
proportional to REXT. For user simplicity, the proportionality
constant is referenced to fixed constants 100kΩ and
655kHz:
fOSC1 is oscillator frequency when Range1 or Range2 are
set. This is nominally 327kHz when REXT is 100kΩ.
fOSC2 is the oscillator frequency when Range3 or Ran ge4
are set. This is nominally 655kHz when REXT is 100kΩ.
When the Range/Gain bits are set to Range1 or Range2,
fOSC runs at half speed compared to when Range/Gain bits
are set to Range3 and Range4.
The automatic fOSC adjustment feature allows significant
improvement of signal-to-noise ratio when detecting very low
lux signals.
Integration Time or Conversion Time
Integration time is the period during which the device’s
analog-to-digital ADC converter samples the photodiode
current signal for a lux measurement. Integration time, in
other words, is the time to complete the conversion of analog
photodiode current into a digital signal (number of counts).
Integration time affects the measurement resolution. For
better resolution, use a longer integration time. For short and
fast conversions use a shorter integration time .
The ISL29003 offers user flexibility in the integration time to
balance resolution, speed and noise rejection. Integration time
can be set internally or externally and can be programmed in
the command register 00(hex) bit 5.
INTEGRATION TIME IN INTERNAL TIMING MODE
This timing mode is programmed in the command register
00(hex) bit 5. Most applications will be using this timing
mode. When using the Internal Timing Mode, fOSC and
n-bits resolution determine the integration time. tint is a
function of the number of clock cycles and f OSC.
n = 4, 8, 12, and16. n is the number of bits of resolution.
Therefore, 2n is the number of clock cycle s. n can be
programmed at the command registe r 00(hex) bit s 1 and 0.
Since fOSC is dual speed depending on the Gain/Range bit,
tint is dual time. The integration time as a function of REXT
and n is:
tint1 is the integration time when the device is configured for
Internal T iming Mode and Gain/Range is set to Range1 or
Range2.
tint2 is the integration time when the device is configured for
Internal T iming Mode and Gain/Range is set to Range3 or
Range4.
T ABLE 12. RESOLUTION AND INTEGRA TION TIME
SELECTION
n
RANGE1
fOSC = 327kHz RANGE4
fOSC = 655kHz
tINT (ms) RESOLUTION
LUX/COUNT tINT (ms) RESOLUTION
(LUX/COUNT)
16 200 0.01 100 1
12 12.8 0.24 6.4 16
8 0.8 3.90 0.4 250
4 0.05 62.5 0.025 4000
REXT = 100kΩ
(EQ. 6)
fosc1 1
2
---100kΩ
REXT
------------------ 655×kHz×=
(EQ. 7)
fosc2 100kΩ
REXT
------------------ 655×kHz=
(EQ. 8)
fOSC11
2
---fOSC2()=
tint 2n1
fosc
----------
×=(EQ. 9)
for Internal Timing Mode only
tint12
nREXT
327kHz 100kΩ×
----------------------------------------------
×=(EQ. 10)
tint22
nREXT
655kHz 100kΩ×
----------------------------------------------
×=(EQ. 11)
ISL29003
9FN7464.6
November 17, 2011
INTEGRATION TIME IN EXTERNAL TIMING MODE
This timing mode is programmed in the command register
00(hex) bit 5. External Timing Mode is recomme nded when
integration time can be synchronized to an external signal
(such as a PWM) to eliminate noise.
For Mode1 or Mode2 operation, the integration starts when
the sync_iic command is sent over the I2C lines. The device
needs two sync_iic commands to complete a photodiode
conversion. The integration then stops when another
sync_iic command is received. Writing a logic 1 to the
sync_iic bit ends the current ADC integration and starts
another one.
For Mode3, the operation is a sequential Mode1 and Mode2.
The device needs three sync_iic co mmands to complete two
photodiode measurement s. The 1st sync_ii c command st a rt s
the conversion of the D iode1. The 2nd sync_iic completes the
conversion of Diode1 and st art s the conversion of Diode2.
The 3rd sync_iic pulse ends the conversion of Diode2 and
start s over again to commence conversion of Diode1 .
The integration time, tint, is determin ed by Equation 12:
iI2C is the number of I2C clock cycles to obtain the tint.
fI2C is the I2C operating frequency.
The internal oscillator, fOSC, operates identically in both the
internal and external timing modes, with the same
dependence on REXT. However, in External Timing Mode,
the number of clock cycles per integration is no longer fixed
at 2n. The number of clock cycles varies with the chosen
integration time, an d is limited to 216 = 65,536. In order to
avoid erroneous lux readings, the integration time must be
short enough not to allow an overflow in the counter register.
fOSC = 327kHz*100kΩ/REXT. When Range/Gain is set to
Range1 or Range2.
fOSC = 655kHz*100kΩ/REXT. When Range/Gain is set to
Range3 or Range4.
Noise Rejection
In general, integrating type ADC’s have excellent
noise-rejection characteristics for periodic noise sources
whose frequency is an integer multiple of the integration
time. For instance, a 60Hz AC unwanted signal’s sum from
0ms to k*16.66ms (k = 1,2...ki) is zero. Similarly, setting the
device’s integration time to be an integer multiple of the
periodic noise signal greatly improves the light sensor output
signal in the presence of noise.
DESIGN EXAMPLE 1
The ISL29003 will be design ed in a portable system. The
ambient light conditions that the device will be exposed to is
at most 500 lux, which is a good office lighting. The light
source has a 50/60Hz power line noise, which is not visible
by the human eye. The I2C clock is 10kHz.
Solution 1
Using Internal Timing Mode
In order to achieve both 60Hz and 50Hz AC noise rejection,
the integration time needs to be adjusted to coincide with an
integer multiple of the AC noise cycle times.
The first instance of integer values at which tint rejects both
60Hz and 50Hz is when i = 6, and j = 5.
Next, the Gain/Range needs to be determined. Based on the
application conditi on given, lux(max) = 500 lux, a range of
1000 lux is desirable. This corresponds to a Gai n/Range
Range1 mode. Also impose a resolution of n = 16-bit.
Hence, we choose Equation 10 to determine REXT.
The Full Scale Range, FSR, needs to be determined from
Equation 3:
The effective transfer function becomes:
TABLE 13. INTEGRATION TIMES FOR TYPICAL REXT VALUES
REXT
(kΩ)
RANGE1
RANGE2 RANGE3
RANGE4
n = 16-BIT n = 12-BIT n = 12-BIT n = 4
50 100 6.4 3.2 0.013
100** 200 13 6.5 0.025
200 400 26 13 0.050
500 1000 64 32 0.125
*Integration time in milliseconds
**Recommended REXT resistor value
tint iI2C
fI2C
----------
=(EQ. 12)
tint 65,535
fOSC
------------------
<(EQ. 13)
tint i160Hz()j150Hz()== (EQ. 14)
tint 6160Hz()51 50Hz()== (EQ. 15)
tint 100ms=
for Internal Timing Mode and Gain/Range is set to Range3 or Range4 only
REXT tint 327kHz 100×× kΩ
2n
-------------------------------------------------------------
=
REXT 50kΩ=
(EQ. 16)
F S R 1000 l u x 100kΩ
50kΩ
------------------
=
F S R 2000 l u x=
(EQ. 17)
Edata
216
------------- 2000 l u x×=(EQ. 18)
ISL29003
10 FN7464.6
November 17, 2011
Solution 2
Using External Timing Mode
From Solution 1, the desired integration time is 100ms. Note
that the REXT resistor only determines the inter oscilla tor
frequency when using external timing mode. Instead, the
integration time is the time between two sync_iic commands
sent through the I2C. The programmer determines how
many I2C clock cycles to wait between two external timing
commands.
iI2C = fI2C*tint = number of I2C clock cycles
iI2C = 10kHz *100ms
iI2C = 1,000 I2C clock cycles. An external sync_iic command
sent 1,000 cycles after another sync_iic command rejects
both 60Hz and 50Hz AC noise signals.
Next, is to pick an arbitrary REXT = 100kΩ and to choose the
Gain/Range Mode. For a maximum 500 lux, Range1 is
adequate. From Equation 3:
The effective transfer function becomes:
DATA is the sensor readi ng data locate d in data registers
04(hex) and 05(hex)
COUNTER is the timer counter value da ta located in data
registers 06(hex) and 07(hex). In this sample problem,
COUNTER = 1000.
IR Rejection
Any filament type light source has a high presence of infrared
component invisible to the human eye. A white fluorescent
lamp, on the other hand has a low IR co ntent. As a resu lt,
output sensitivity may vary depending on the light so urce.
Maximum attenuation of IR can be achieved by properly
scaling the readings of Diode1 and Diode 2. The user obt ains
data reading from sensor Dio de1 (D1), which is sensi tive to
visible and IR, then reading from sensor Diode2 (D2), whi ch is
mostly sensitive from IR. The graph in Figure 7 shows the
effecti ve spectral response af te r ap plying Equation 19 of the
ISL29003 from 400nm to 1000n m. Equati on 19 describe s the
method of cancelling IR in internal timing mode.
Where:
data = lux amount in number of counts less IR presence
D1 = data reading of Diode1
D2 = data reading of Diode2
n = 1.85. This is a fudge factor to scale back the sensitivity
up to ensure Equation 4 is valid.
k = 7.5. This is a scaling factor for the IR sensitive Diode2.
Flat Window Lens Design
A window lens will surely limit the viewing angle of the
ISL29003. The window lens should be placed directly on top
of the device. The thickness of the lens should be kept at
minimum to minimize loss of power due to reflection and
also to minimize loss of loss due to absorption of energy in
the plastic material. A thickness of t = 1mm is recommended
for a window lens design. The bigger the diameter of the
window lens, the wider the viewing angle is of the ISL29003.
Table 16 shows the recommended dimensions of the optical
window to ensure both 35° and 45° viewing angle. These
dimensions are based on a window lens thickness of 1.0mm
and a refractive index of 1.59.
T ABLE 14. SOLUTION1 SUMMARY T O EXAMPLE DESIGN
PROBLEM
DESIGN PARAMETER VALUE
tint 100ms
REXT 50kΩ
Gain/Range Mode Range1 = 1000 lux
FSR 2000 lux
# of clock cycles 216
Transfer Function
T ABLE 15. SOLUTION2 SUMMARY T O EXAMPLE DESIGN
PROBLEM
DESIGN PARAMETER VALUE
tint 100ms
REXT 100kΩ
Gain/Range Mode Range1 = 1000 lux
FSR 1000 lux
# of clock cycles COUNTER = 1000
Transfer Function
FSR 1000 lux100kΩ
100kΩ
------------------
=
F S R 1000 l u x=
EDATA
COUNTER
--------------------------------1000 l u x×=
D3 n D1 kD2()=(EQ. 19)
DLENS
t
D1 DTOTAL
= Viewing angle
WINDOW LENS
ISL29003
FIGURE 4. FLAT WINDOW LENS
ISL29003
11 FN7464.6
November 17, 2011
Suggested PCB Footprint
Footprint pads should be a nominal 1-to-1 correspondence
with package pads. Since ambient light sensor devices do
not dissipate high power , heat dissipation through the
exposed pad is not important; instead, similar to DFN or
QFN, the exposed pad provides robustness in board mount
process. Intersil recommends mounting the exposed pad to
the PCB, but this is not mandatory.
Layout Considerations
The ISL29003 is relatively insensitive to layout. Like other
I2C devices, it is intended to provide excellent performance
even in significantly noisy environments. There are only a
few considerations that will ensure best performance.
Route the supply and I2C traces as far as possible from all
sources of noise. Use two power-supply decoupling
capacitors, 4.7µF and 0.1µF, placed close to the device.
Typical Circuit
A typical application for the ISL2900 3 is shown in F igure 6.
The ISL29003’s I2C address is internally hardwired as
1000100. The device can be tied onto a system’s I2C bus
together with other I2C compliant devices.
Soldering Considerations
Convection heati ng is recommended for reflow soldering;
direct-infrared heating is not recommended. The plastic
ODFN package does not require a custom reflow soldering
profile, and is qualified to +260°C. A standard reflow
soldering profile with a +260°C maximum is recommended.
T ABLE 16. RECOMMENDED DIMENSIONS FOR A FLA T
WINDOW DESIGN
DTOTAL D1 DLENS @ 35°
VIEWING ANGLE DLENS @ 45°
VIEWING ANGLE
1.5 0.50 2.25 3.75
2.0 1.00 3.00 4.75
2.5 1.50 3.75 5.75
3.0 2.00 4.30 6.75
3.5 2.50 5.00 7.75
t = 1 Thickness of lens
D1 Distance between ISL29001 and inner edge of lens
DLENS Diameter of lens
DTOTAL Distance constraint between the ISL29001 and lens
outer edge
*All dimensions are in mm.
6
5
4
0.56mm
0.46mm
2.00mm
SENSOR OFFSET
1
2
3
0.29mm
2.10mm
FIGURE 5. SENSOR LOCATION DRAWING
FIGURE 6. ISL29003 TYPICAL CIRCUIT
VDD
1
GND
2
REXT
3INT 4
SCL 5
SDA 6
ISL29003
R1
10k R2
10k R3
RES1
REXT
100k
C2
0.1µF
C1
4.7µF
2.5V TO 3.3V
1.8V TO 5.5V
MICROCONTROLLER
SDA
SCL
I2C SLAVE_0 I2C SLAVE_1 I2C SLAVE_n
I2C MASTER
SCL
SDA
SCL
SDA
ISL29003
12 FN7464.6
November 17, 2011
Typical Performance Curves (REXT = 100kΩ)
FIGURE 7. SPECTRAL RESPONSE FIGURE 8. RADIATION PATTERN
FIGURE 9. SUPPLY CURRENT vs SUPPLY VOLTAGE FIGURE 10. OUTPUT CODE FOR 0 LUX vs SUPPLY VOLTAGE
FIGURE 11. OUTPUT CODE vs SUPPLY VOLTAGE FIGURE 12. OSCILLATOR FREQUENCY vs SUPPLY VOLTAGE
0
10
20
30
40
50
60
70
80
90
100
300 400 500 600 700 800 900 1k
WAVELENGTH (nm)
NORMALIZED RESPONSE (%)
ISL29003 D1
ISL29003 D2
RADIATION PATTERN
LUMINOSITY
ANGLE
RELATIVE SENSITIVITY
90º
80º
70º
60º
50º
40º 30º 20º 10º
90º
80º
70º
60º
50º
40º
30º
20º
10º
0.2 0.4 0.6 0.8 1.0
2.0 2.3 2.6 2.9 3.2 3.5 3.8
320
306
292
278
264
250
SUPPLY CURRENT (mA)
SUPPLY VOLTAGE (V)
TA = +27°C
COMMAND = 00H
5000 lux
200 lux
2.0 2.3 2.6 2.9 3.2 3.5 3.8
10
8
6
4
2
0
OUTPUT CODE (COUNTS)
SUPPLY VOLTAGE (V)
TA = +27°C
COMMAND = 00H
0 lux
RANGE 2
2.0 2.3 2.6 2.9 3.2 3.5 3.8
1.015
1.010
1.005
1.000
0.995
0.990
OUTPUT CODE RATIO
(% FROM 3V)
SUPPLY VOLTAGE (V)
5000 lux
200 lux
TA = +27°C
COMMAND = 00H
2.0 2.3 2.6 2.9 3.2 3.5 3.8
320.0
319.5
319.0
318.5
318.0
OSCILLATOR FREQUENCY (kHz)
SUPPLY VOLTAGE (V)
TA = +27°C
ISL29003
13
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9001 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No lice nse is gran t ed by i mpli catio n or other wise u nder an y p a tent or patent rights of I nter sil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
FN7464.6
November 17, 2011
FIGURE 13. SUPPLY CURRENT vs TEMPERATURE FIGURE 14. OUTPUT CODE FOR 0 LUX vs TEMPERATURE
FIGURE 15. OUTPUT CODE vs TEMPERATURE FIGURE 16. OSCILLATOR FREQUENCY vs TEMPERATURE
Typical Performance Curves (REXT = 100kΩ) (Continued)
-60 -20 20 60 100
315
305
295
285
275
265
SUPPLY CURRENT (µA)
TEMPERATURE (°C)
VDD = 3V
COMMAND = 00H
5000 lux
200 lux
RANGE 1
RANGE 3
-60 -20 20 60 100
10
8
6
4
2
0
OUTPUT CODE (COUNTS)
TEMPERATURE (°C)
VDD = 3V
COMMAND = 00H
0 lux
RANGE 2
-60 -20 20 60 100
1.080
1.048
1.016
0.984
0.952
0.920
OUTPUT CODE RATIO
(% FROM +25°C)
5000 lux
200 lux
VDD = 3V
COMMAND = 00H
TEMPERATURE (°C)
RANGE 1
RANGE 3
-60 -20 20 60 100
330
329
328
327
326
325
OSCILLATOR FREQUENCY (kHz)
TEMPERATURE (°C)
VDD = 3V
ISL29003
14 FN7464.6
November 17, 2011
ISL29003
Package Outline Drawing
L6.2x2.1
6 LEAD OPTICAL DUAL FLAT NO-LEAD PLASTIC PACKAGE (ODFN)
Rev 3, 5/11
located within the zone indicated. The pin #1 identifier may be
Unless otherwise specified, tolerance : Decimal ± 0.05
Tiebar shown (if present) is a non-functional feature.
The configuration of the pin #1 identifier is optional, but must be
between 0.15mm and 0.30mm from the terminal tip.
Dimension applies to the metallized terminal and is measured
Dimensions in ( ) for Reference Only.
Dimensioning and tolerancing conform to ASME Y14.5m-1994.
6.
either a mold or mark feature.
3.
5.
4.
2.
Dimensions are in millimeters.1.
NOTES:
BOTTOM VIEW
DETAIL "X"
SIDE VIEW
TYPICAL RECOMMENDED LAND PATTERN
TOP VIEW
(4X) 0.10
INDEX AREA
PIN 1
ABPIN #1
B0.10 MAC
C
SEATING PLANE
BASE PLANE
0.08
0.10
SEE DETAIL "X"
C
C
0 . 00 MIN.
0 . 05 MAX.
0 . 2 REF
C5
1
6
6
2.10
2.00
2.10
2.50
(1.35)
(6x0.30)
0.65
(6x0.55)
(6x0.20)
(4x0.65)
1.30 REF1.35
0.65
0.65
6x0.35 ± 0.05
PACKAGE
6X 0.30±0.05
INDEX AREA
OUTLINE
4
MAX 0.75
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Intersil:
ISL29003IROZ-EVALZ