2000 Infineon Technologies Corp. • Optoelectronics Division • San Jose, CA ISD201X/231X/235X
www.infineon.com/opto • 1-888-Infineon (1-888-463-4636)
OSRAM Opto Semiconductors GmbH & Co. OHG • Regensburg, Germany
www.osram-os.com • +49-941-202-7178 2 March 23, 2000-17
.200
(5.08) .100
(2.54)
.270
(6.85)
.050 (1.27)
±.005 (.13)
.100 (2.54) typ.
±.005 (.13)
10 pl., non-cum.
.020 (.54)
±.003 (.08)
.050 (1.27)
12 pl.
Seating
Plane
ISD201X
Z H
YYWW
Pin 1
Indicator
Year
Work
Week
Hue Code
Luminous
Intensity Code
OSRAM
Part Number
.010 (.25)
±.002 (.05)
typ.
.300
(7.62)
.699 (17.7)
max.
.083
(2.11)
.310
(7.87)
.290
(7.25)
.175 (4.44)
±.005 (.13)
Pin 1
marked by
dot on back
of package
.146
(3.7)
Pin Function Pin Function
1 Column 1 7 Data Out
2 Column 2 8 VB
3 Column 3 9 VCC
4 Column 4 10 Clock
5 Column 5 11 Ground
6 No connection 12 Data In
.200
(5.08)
Pin 1 indicators
dot and notch on
package underside
.100
(2.54)
.270
(6.86)
.100 (2.54)
±.005 (.13)
non-cum. 10 pl.
.020 (.51)
±.003 (.08)
.050
(1.27)
12 pl.
ISD231X
Z H
YYWW
Year
Work Week
Hue Code
Luminous
Intensity Code
OSRAM
Part No.
.010 (.25)
±.002 (.05)
.250 (6.35)
±.010 (.25)
C
L
.790 (20.07)
max. .112
(2.84)
.332
(8.43)
.197 (5.00)
±.005 (.13)
.192
(4.88)
12 11 10 9 8 7
123456
.099 (2.51)
±.005 (.13)
Dimensions in Inches (mm)
ISD231X/235X
ISD201X
DESCRIPTION
(continued)
In the normal mode of operation, input data for digit four, col-
umn one is loaded into the seven on-board shift register
locations one through seven. Column one data for digits 3, 2,
and 1 is shifted into the display shift register locations. Then
column one input is enabled for an appropriate period of
time, T. A similar process is repeated for columns 2, 3, 4,
and 5. If the decode time and load data time into the shift
register is t, then with five columns, each column of the dis-
play is operating at a duty factor of:
T+t, allotted to each display column, is generally chosen to
provide the maximum duty factor consistent with the mini-
mum refresh rate necessary to achieve a flicker free display.
For most strobed display systems, each column of the display
should be refreshed (turned on) at a minimum rate of 100
times per second.
With columns to be addressed, this refresh rate then gives a
value for the time T+t of: 1⁄ [5 x (100)]=2.0 msec. If the
device is operated at 5.0 MHz clock rate maximum, it is possi-
ble to maintain t<T. For short display strings, the duty factor
will then approach 20%.
See Appnote 44 for application information and Appnotes 18,
19, 22, 23 at www.infineon.com/opto.
Maximum Ratings
Supply Voltage
V
CC
to GND...............................–0.5 V to +7.0 V
Inputs, Data Out and V
B
.............................–0.5 V to
V
CC
+0.5 V
Column Input Voltage,
V
COL
.............................–0.5 V to +6.0 V
Operating Temperature Range ....................... –55
°
C to +100
°
C
Storage Temperature Range ........................... –65
°
C to +125
°
C
Maximum Solder Temperature, 0.063" (1.59 mm)
below Seating Plane, t<5.0 s........................................ 260
°
C
Maximum Allowable Power Dissipation,
T
A
=25
°
C
(2)
ISD2010 .......................................................................0.91 W
ISD2011/2/3 .................................................................0.86 W
ISD231X.........................................................................1.1 W
ISD235X.......................................................................1.35 W
Notes:
1)
Operation above +100
°
C ambient is possible if the following
conditions are met. The junction should not exceed
T
J
=125
°
C
and the case temperature (as measured at pin 1 or the back of
the display) should not exceed TC=100
°
C.
2)
Maximum allowable dissipation is derived from
V
CC
=5.25 V,
V
B
=2.4 V,
V
COL
=3.5 V 20 LEDs on per character, 20% DF.
DF T
5T 1+()
---------------------=