MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 General Description The MAX6330/MAX6331 combine a precision shunt regulator with a power-on reset function in a single SOT23-3 package. They offer a low-cost method of operating small microprocessor (P)-based systems from high-voltage sources, while simultaneously protecting Ps from powerup, power-down, and brownout conditions. Both active-low (MAX6330) and active-high (MAX6331) push/pull output versions are available. The output voltage has 1.5% tolerance. The MAX6330/MAX6331 operate over a wide shunt current range from 100A to 50mA, and offer very good transient immunity. A 3-pin SOT23 package allows for a significant reduction in board space and improves reliability compared to multiple-IC/discrete solutions. These devices have a minimum order increment of 2,500 pieces. Applications Features 100A to 50mA Shunt Current Range Low Cost 3-Pin SOT23 Package 1.5% Tolerance on Output Voltage Three Shunt Voltages Available: 5V, 3.3V, 3.0V Precision Power-On Reset Threshold: 1.5% Tolerance Available with Either RESET (MAX6331) or RESET (MAX6330) Outputs 140ms Reset Timeout Period--No External Components Required Ordering Information PART* MAX6330_UR-T SUFFIX Typical Operating Circuit RS IIN VSHUNT CL 0.1F* VCC SHUNT MAX6330 MAX6331 RESET (RESET) GND 3 SOT23-3 RESET THRESHOLD (V) SHUNT REGULATOR VOLTAGE (V) MAX6330 P L 4.63 5.0 EKAA ELAA 3.06 3.3 EMAA ENAA S 2.78 3.0 EDAA EPAA TOP VIEW GND 1 RESET INPUT MAX6330 MAX6331 GND MAX6331 T RESET 2 (RESET) SOT23-3 *SEE THE SECTION CHOOSING THE BYPASS CAPACITOR (CL) ( ) ARE FOR THE MAX6331 19-1348; Rev 2; 4/14 SOT TOP MARK Pin Configuration ILOAD ISHUNT PIN-PACKAGE MAX6331_UR-T -40C to +85C 3 SOT23-3 *Insert the desired suffix letter (from the table below) into the blank to complete the part number. These devices have a minimum order increment of 2,500 pieces. Devices are available in both leaded and lead-free packaging. Specify lead-free by replacing "-T" with "+T" when ordering. Controllers Household Appliances Intelligent Instruments Critical P and C Power Monitoring Portable/Size-Sensitive Equipment VIN TEMP RANGE -40C to +85C 3 SHUNT MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 Absolute Maximum Ratings Terminal Voltage (with respect to GND), All Pins Except SHUNT...................-0.3V to (VSHUNT + 0.3V) Input Current (ISHUNT)........................................................60mA Output Current (RESET/RESET)........................................20mA Short-Circuit Duration.................................................Continuous Continuous Power Dissipation SOT23-3 (derate 4mW/C above +70C).....................320mW Operating Temperature Range............................ -40C to +85C Storage Temperature Range............................. -65C to +160C Lead Temperature (soldering, 10sec).............................. +300C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Electrical Characteristics (ISHUNT = 1mA, CL = 0.1F, TA = -40C to +85C, unless otherwise noted. Typical values are at TA = +25C.) PARAMETER SYMBOL CONDITIONS MAX633_L VSHUNT Regulation Voltage (Note 1) VSHUNT ISHUNT = 0.1mA to 50mA MIN TYP MAX TA = +25C 4.93 5.0 5.07 TA = -40C to +85C 4.85 TA = +25C 3.25 MAX633_T TA = -40C to +85C TA = +25C MAX633_S TA = -40C to +85C TA = 0C to +70C TA = -40C to +85C Minimum VSHUNT for which RESET is Valid (MAX6330) VSHUNT Tempco Minimum Shunt Current (Note 2) Maximum Shunt Current (Note 3) www.maximintegrated.com 3.40 3.0 3.09 V 40 ppm/C 60 A ISHUNT(max) 50 VTH MAX633_T TA = +25C 4.56 TA = -40C to +85C 4.50 TA = +25C 3.01 TA = -40C to +85C 2.97 TA = +25C 2.74 TA = -40C to +85C 2.70 100mV overdrive, CL = 15pF 100 V 3.04 1.2 Reset Threshold Tempco Reset Pulse Width 3.35 2.91 100 MAX633_S VSHUNT to Reset Delay 3.3 1.0 ISHUNT(min) MAX633_L Reset Threshold Voltage 5.15 3.20 2.96 UNITS 4.63 mA 4.69 4.75 3.06 3.11 3.15 2.78 V 2.82 2.86 40 ppm/C 20 s 140 200 ms Maxim Integrated 2 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 Electrical Characteristics (continued) (ISHUNT = 1mA, CL = 0.1F, TA = -40C to +85C, unless otherwise noted. Typical values are at TA = +25C.) ISINK = 3.2mA RESET/RESET Output Voltage Low (Note 4) VOL ISINK = 1.2mA VOH 0.4 MAX6331L, VTH(max) MAX6330T/S, VTH(min) 0.3 MAX6331T/S, VTH(max) V MAX6330, V SHUNT = 1V, I SINK = 50A, TA = 0C to +70C 0.3 MAX6330, V SHUNT = 1.2V, I SINK = 50A, TA = -40C to +85C 0.3 ISOURCE = 800A RESET/RESET Output Voltage High (Note 4) MAX6330L, VTH(min) ISOURCE = 500A MAX6331L, VTH(min) MAX6330L, VTH(max) MAX6331T/S, VTH(min) MAX6330T/S, VTH(max) MAX6331, 1.8V < VSHUNT < VTH(min), ISOURCE = 150A 0.8 x VSHUNT 0.8 x VSHUNT V 0.8 x VSHUNT Note 1: It is recommended that the regulation voltage be measured using a 4-wire force-sense technique when operating at high shunt currents. For operating at elevated temperatures, the device must be derated based on a +150C maximum allowed junction temperature and a maximum thermal resistance of 0.25C/mW junction to ambient when soldered on a printed circuit board. The TA = +25C specification over load is measured using a pulse test at 50mA with less than 5ms on time. Note 2: Minimum shunt current required for regulated VSHUNT. Note 3: Maximum shunt current required for regulated VSHUNT. Note 4: In a typical application where SHUNT serves as the system voltage regulator, note that both ISOURCE for VOH and ISINK for VOL come from VSHUNT (see the Typical Operating Circuit). www.maximintegrated.com Maxim Integrated 3 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 Typical Operating Characteristics (Typical Operating Circuit, CL = 0.1F, ILOAD = 0mA, TA = +25C, unless otherwise noted.) 0.01 0.1 1 10 ISHUNT = 1mA 0.995 0.990 50 -40 -20 SHUNT CURRENT (mA) 0 20 40 60 0 20 40 ISHUNT = 1mA TO 1mA 5 0.0047 0.01 60 80 140 130 120 110 100 -40 -20 0 20 40 START-UP TRANSIENT RS = 15k 60 80 VIN 50V/div RECOMMENDED CAPACITOR VSHUNT 2V/div RECOMMENDED CAPACITANCE 10 1 MAX6330 TOC03 POWER-UP RESET TIMEOUT (ms) 150 STABILITY BOUNDARY CONDITIONS RECOMMENDED CAPACITOR OPERATING REGION 0.1 160 TEMPERATURE (C) 40 20 10 TEMPERATURE (C) UNSTABLE REGION SHUNT CURRENT (mA) MAX6330 TOC04 0.995 30 15 POWER-UP RESET TIMEOUT vs. TEMPERATURE 1.000 50 ISHUNT = 0.1mA TO 5mA 20 LOAD CAPACITANCE (F) MAX6330 TOC06 NORMALIZED RESET THRESHOLD 1.005 -20 25 TEMPERATURE (C) 1.010 -40 ISHUNT = 5mA TO 50mA 30 0 80 NORMALIZED RESET THRESHOLD vs. TEMPERATURE 0.990 35 MAX6330 TOC07 0.990 TA = +85C ISHUNT = 25mA 1.000 SHUNT VOLTAGE OVERSHOOT vs. BYPASS CAPACITANCE (CL) 40 SHUNT VOLTAGE OVERSHOOT (mV) TA = -40C 0.995 MAX6330 TOC02 ISHUNT = 50mA NORMALIZED SHUNT VOLTAGE TA = +25C 1.000 1.005 MAX6330 TOC01 NORMALIZED SHUNT VOLTAGE 1.005 NORMALIZED SHUNT VOLTAGE vs. TEMPERATURE MAX6330 TOC5 NORMALIZED SHUNT VOLTAGE vs. SHUNT CURRENT 0 1 0.001 0.01 0.1 1 LOAD CAPACITANCE (F) www.maximintegrated.com Maxim Integrated 4 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 Pin Description PIN MAX6330 MAX6331 NAME FUNCTION 1 1 GND Ground 2 -- RESET Inverting Reset Output. RESET remains low while VSHUNT is below the reset threshold and for 140ms after VSHUNT rises above the threshold. -- 2 RESET Noninverting Reset Output. RESET remains high while VSHUNT is below the reset threshold and for 140ms after VSHUNT rises above the threshold. 3 3 SHUNT Regulated Shunt Voltage (+5V, +3.3V, or +3.0V) Detailed Description Reset Output A microprocessor's (P's) reset input starts the P in a known state. The MAX6330/MAX6331 P supervisory circuits assert reset to prevent code-execution errors during power-up, power-down, or brownout conditions. RESET is guaranteed to be a logic low for VSHUNT > 1V. Once VSHUNT exceeds the reset threshold, an internal timer keeps RESET low for the reset timeout period; after this interval, RESET goes high. If a brownout condition occurs (VSHUNT dips below the reset threshold), RESET goes low. When VSHUNT falls below the reset threshold, the internal timer resets to zero and RESET goes low. The internal timer starts after VSHUNT returns above the reset threshold, and RESET then remains low for the reset timeout period. Consider the following information when choosing the external resistor RS: 1) The input voltage range, (VIN) 2) The regulated voltage, (VSHUNT) 3) The output current range, (ILOAD) Choose RS as follows: (VIN(max) - VSHUNT (min)) / (50mA + ILOAD(min)) RS (VIN(min) - VSHUNT (max)) / (100A + ILOAD(max)) Choose the largest nominal resistor value for RS that gives the lowest current consumption. Provide a safety margin to incorporate the worst-case tolerance of the VIN IIN RS VSHUNT ILOAD ISHUNT The MAX6331 has an active-high RESET output that is the inverse of the MAX6330's RESET output. CL SHUNT Shunt Regulator RESET GENERATOR The shunt regulator consists of a pass device and a controlling circuit, as illustrated in Figure 1. The pass device allows the regulator to sink current while regulating the desired output voltage within a 1.5% tolerance. The shunt current range (ISHUNT) is 100A to 50mA. The pass transistor in the MAX6330/MAX6331 maintains a constant output voltage (VSHUNT) by sinking the necessary amount of shunt current. When ILOAD (see Typical Operating Circuit) is at a maximum, the shunt current is at a minimum, and vice versa: IIN = ISHUNT + ILOAD = (VIN - VSHUNT) / RS www.maximintegrated.com 140ms TIMEOUT RESET (RESET) MAX6330 MAX6331 1.2V GND ( ) ARE FOR MAX6331 Figure 1. Functional Diagram Maxim Integrated 5 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 PR = IIN(VIN(max) - VSHUNT) = I2INRS = (VIN(max) - VSHUNT)2 / RS Applications Information ILOAD 2mA/div IIN = 2mA, ILOAD = 0 to 1.9mA VSHUNT IS AC COUPLED MAX6330 FIG 02 resistor used. Ensure that the resistor's power rating is adequate, using the following general power equation: 0 Negative-Going VSHUNT Transients In addition to issuing a reset to the P during power-up, power-down, and brownout conditions, the MAX6330/ MAX6331 are relatively immune to short-duration negative-going VSHUNT transients (glitches). Additional bypass filter capacitance mounted close to the SHUNT pin provides additional transient immunity. Choosing the Bypass Capacitor, CL 0 VSHUNT 20mV/div Figure 2. Load-Transient Response with CL = 0.22F ILOAD (diverted from regulator) = ISHUNT(max) - ISHUNT(min) = 50mA - 100A = 49.9mA The shunt regulator has a finite response to this transient. The instantaneous requirements of the load change are met by the charge on CL, resulting in overshoot/undershoot on VSHUNT. The magnitude of this overshoot/undershoot increases with ISHUNT and decreases with CL. When VSHUNT undershoots, the shunt current decreases to where it will only draw quiescent current (IQ), and the shunt element turns off. At this point, VSHUNT will slew toward VIN at the following rate: VSHUNT / t = (IIN - ILOAD - 60A) / CL As VSHUNT rises, it will turn on the shunt regulator when it can sink 100A of current. A finite response time for the shunt regulator to start up will result in a brief overshoot of VSHUNT before it settles into its regulation voltage. Therefore, ILOAD should always be 100A or more below IIN, or VSHUNT will not recover to its regulation point. To prevent this condition, be sure to select the correct series-resistor RS value (see the Shunt Regulator section). Figures 2, 3, and 4 show load-transient responses for different choices of bypass capacitors on VSHUNT. These photos clearly illustrate the benefits and drawbacks of the capacitor options. A smaller bypass www.maximintegrated.com ILOAD 2mA/div IIN = 2mA, ILOAD = 0 to 1.9mA, VSHUNT IS AC COUPLED 0 0 VSHUNT 20mV/div Figure 3. Load-Transient Response with CL = 0.033F ILOAD 2mA/div IIN = 2mA, ILOAD = 0 to 1.9mA VSHUNT IS AC COUPLED MAX6330 FIG 04 The maximum load current that can be diverted from the regulator is: MAX6330 FIG 03 The bypass capacitor (CL) on the SHUNT pin can significantly affect the device's load-transient response, so choose it carefully. When a load transient occurs, the current for this load is diverted from the shunt regulator. 0 0 VSHUNT 20mV/div Figure 4. Load-Transient Response with CL = 0.0047F Maxim Integrated 6 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 capacitor allows a sharper drop in VSHUNT when the load transient occurs, and will suffer from a steeper overshoot when the device re-enters regulation. On the other hand, the increased compensation on a larger bypass capacitor will lead to a longer recovery time to regulation. The Typical Operating Characteristics graph Overshoot vs. Bypass Capacitance (CL) illustrates this trade-off. If the compensation of the bypass capacitor chosen is insufficient, the output (VSHUNT) can oscillate. Before choosing a bypass capacitor for the desired shunt current, observe the stability boundary conditions indicated in the Typical Operating Characteristics. The minimum output capacitance is 0.03F to ensure stability over the full load-current range. Adding Hysteresis In certain circumstances, the MAX6330 can be trapped in a state that forces it to enter into and exit from a reset condition indefinitely. This usually occurs in systems where VSHUNT is just below the device's trip threshold and the system draws less quiescent current under reset conditions than when operating out of reset. The difference in supply current when the device is in or out of reset can translate to a significant change in the voltage drop across RS, which the MAX6330's built-in hysteresis may not overcome. A 100k pull-up resistor will overcome this condition and add hysteresis (Figure 5). VIN RS Note that adding this pull-up resistor to the MAX6330 will render RESET invalid with VSHUNT < 1V, since this output loses sinking capability at this point, and the pull-up resistor would invalidate the signal. This does not present a problem in most applications, since most Ps and other circuitry are inoperative when VSHUNT is below 1V. Interfacing to Ps with Bidirectional Reset Pins Microprocessors with bidirectional reset pins (such as the Motorola 68HC11 series) can contend with MAX6330's reset output. If, for example, the MAX6330's RESET output is asserted high and the P wants to pull it low, indeterminate logic levels may result. To correct this, connect a 4.7k resistor between the RESET output and the P reset I/O (Figure 6). Buffer the RESET output to other system components. Also, RS must be sized to compensate for additional current drawn by the P during the fault condition. Shunt Current Effects on VSHUNT and VTH When sinking large shunt currents, power dissipation heats the die to temperatures greater than ambient. This may cause the VSHUNT and VTH tolerances to approach 3% at high ambient temperatures and high shunt currents. Limit the die temperature to less than +150C using JA = 0.25C/mW. VIN CL MAX6330 GND TO OTHER SYSTEM COMPONENTS VSHUNT CL RHYST 100k SHUNT RESET RS VCC SHUNT P MAX6330 MAX6331 RESET INPUT VCC 4.7k P RESET (RESET) GND GND GND ( ) ARE FOR MAX6331 Figure 5. Adding Hysteresis to the MAX6330 www.maximintegrated.com Figure 6. Interfacing to Ps with Bidirectional Reset I/O Maxim Integrated 7 MAX6330/MAX6331 Chip Information TRANSISTOR COUNT: 283 www.maximintegrated.com Precision Shunt Regulators with Reset in SOT23-3 Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a "+", "#", or "-" in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 3 SOT23 U3+1 21-0151 90-0179 Maxim Integrated 8 MAX6330/MAX6331 Precision Shunt Regulators with Reset in SOT23-3 Revision History REVISION NUMBER REVISION DATE 2 4/14 PAGES CHANGED DESCRIPTION No /V OPNs; Removed Automotive reference from Applications section 1 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated's website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. (c) 2014 Maxim Integrated Products, Inc. 9