–1– ASCTB5E 201802-T
ORDERING INFORMATION
Relay for control panel of
1c 10A, 2c 5A and 1a 16A
HN RELAYS (AHN)
RoHS compliant
FEATURES
1. Slim and compact size
20% smaller (width and height) than
existing model* (with the condition of
screw terminal socket for DIN rail)
*Compared with our HC/HJ relay.
2. High-capacity
Max. switching current:
16 A (for 1 Form C type at AC load)
3. Slim screw terminal sockets and PC
board terminal sockets are available
TYPICAL APPLICATIONS
Control panels
Power supply units
Molding machines
Machine tools
Welding equipment
Agricultural equipment
Office equipment
Vending machines
Communications equipment
Amusement machines, etc.
HN relays
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 1 Form A (TM type only)
AHN
Terminal arrangement
1: AC plug-in type
2: DC plug-in type
5: AC TM type
6: DC TM type
Nominal coil voltage
05:
X0:
X1:
Y0:
Y2:
5 V, 06: 6 V, 12: 12 V, 24: 24 V, 48: 48 V
100/110 V AC, 100 V DC
110/120 V AC, 110 V DC
200/220 V AC
220/240 V AC
Type
N:
Nil:
2 Form C type
1 Form C type, 1 Form A type
Type classification
0: Standard
1: With LED indication
2: With diode
3: With diode and LED indication
Notes: 1. Certified by UL/C-UL and VDE
(Please consult us for VDE approved TM type.)
2. The LED indication color is green.
HN (AHN)
–2– ASCTB5E 201802-T
TYPES
5. TM type
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Nominal coil voltage 1 Form A
Part No.
5V DC AHN36005
6V DC AHN36006
12V DC AHN36012
24V DC AHN36024
48V DC AHN36048
100V DC AHN360X0
110V DC AHN360X1
12V AC AHN35012
24V AC AHN35024
100/110V AC AHN350X0
110/120V AC AHN350X1
200/220V AC AHN350Y0
220/240V AC AHN350Y2
1. Plug-in type
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
2. Plug-in type (with LED indication)
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Nominal coil voltage 1 Form C 2 Form C
Part No. Part No.
5V DC AHN12005 AHN22005N
6V DC AHN12006 AHN22006N
12V DC AHN12012 AHN22012N
24V DC AHN12024 AHN22024N
48V DC AHN12048 AHN22048N
100V DC AHN120X0 AHN220X0N
110V DC AHN120X1 AHN220X1N
12V AC AHN11012 AHN21012N
24V AC AHN11024 AHN21024N
100/110V AC AHN110X0 AHN210X0N
110/120V AC AHN110X1 AHN210X1N
200/220V AC AHN110Y0 AHN210Y0N
220/240V AC AHN110Y2 AHN210Y2N
Nominal coil voltage 1 Form C 2 Form C
Part No. Part No.
5V DC AHN12105 AHN22105N
6V DC AHN12106 AHN22106N
12V DC AHN12112 AHN22112N
24V DC AHN12124 AHN22124N
48V DC AHN12148 AHN22148N
100V DC AHN121X0 AHN221X0N
110V DC AHN121X1 AHN221X1N
12V AC AHN11112 AHN21112N
24V AC AHN11124 AHN21124N
100/110V AC AHN111X0 AHN211X0N
110/120V AC AHN111X1 AHN211X1N
200/220V AC AHN111Y0 AHN211Y0N
220/240V AC AHN111Y2 AHN211Y2N
3. Plug-in type (with diode)
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
4. Plug-in type (with diode and LED indication)
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Nominal coil voltage 1 Form C 2 Form C
Part No. Part No.
5V DC AHN12205 AHN22205N
6V DC AHN12206 AHN22206N
12V DC AHN12212 AHN22212N
24V DC AHN12224 AHN22224N
48V DC AHN12248 AHN22248N
100V DC AHN122X0 AHN222X0N
110V DC AHN122X1 AHN222X1N
Nominal coil voltage 1 Form C 2 Form C
Part No. Part No.
5V DC AHN12305 AHN22305N
6V DC AHN12306 AHN22306N
12V DC AHN12312 AHN22312N
24V DC AHN12324 AHN22324N
48V DC AHN12348 AHN22348N
100V DC AHN123X0 AHN223X0N
110V DC AHN123X1 AHN223X1N
HN (AHN)
–3– ASCTB5E 201802-T
RATING
1. Coil data
1) DC coils
2) AC coils (50/60Hz)
2. Specifications (Plug-in Standard type and TM type)
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal coil current
[±20%]
Coil resistance
(at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
106.4mA 47Ω [±10%]
0.53W 170%V of
nominal voltage
6V DC 88.2mA 68Ω [±10%]
12V DC 44.4mA 270Ω [±10%]
24V DC 22.0mA 1,090Ω [±10%]
48V DC 11.0mA 4,350Ω [±10%]
100V DC 5.3mA 18,870Ω [±10%]
110V DC 4.8mA 22,830Ω [±10%]
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal coil current [±20%] Nominal operating power Max. applied voltage
(at 20°C 68°F)
50Hz 60Hz 50Hz 60Hz
12V AC
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
93mA 75mA
Approx.
1.1 to 1.4 V A
Approx.
0.9 to 1.2 V A
140%V of
nominal voltage
24V AC 46.5mA 37.5mA
100/110V AC 11.0/13.0mA 9.0/10.6mA
110/120V AC 10.0/11.8mA 8.2/9.7mA
200/220V AC 5.5/6.5mA 4.5/5.3mA
220/240V AC 5.0/5.9mA 4.1/4.8mA
Characteristics Item Specifications
Contact
Arrangement 1 Form C 2 Form C 1 Form A (TM type)
Contact resistance (Initial) Max. 100 mΩ
(By voltage drop 6 V DC 1A)
Max. 50 mΩ
(By voltage drop 6 V DC 1A)
Max. 100 mΩ
(By voltage drop 6 V DC 1A)
Contact material AgSnO2 type AgNi type AgSnO2 type
Rating
Nominal switching capacity (resistive load) 10A 250V AC, 10A 30V DC 5A 250V AC, 5A 30V DC 16A 250V AC, 16A 30V DC
Max. switching power (resistive load) 4,000VA, 300W 1,250VA, 150W 4,000VA, 480W
Max. switching voltage 250V AC, 30V DC
Max. switching current 16A (at AC load),
10A (at DC load) 5A 16A
Nominal operating power 0.53W, 0.9VA
Min. switching capacity (Reference value)*1100mA 5V DC 10mA 5V DC 100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 3,000 Vrms for 1min.
(Detection current: 10mA.)
Between contact and coil 5,000 Vrms for 1min. (Detection current: 10mA.)
Temperature rise (coil) (at 70°C 158°F) Max. 60°C 140°F (By resistive method, nominal coil voltage)
Operate time (at 20°C 68°F)*2Max. 15ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)*2Max. 5ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without
diode)/Max. 20ms (with diode)
Mechanical
characteristics
Shock resistance Functional Min. 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical AC: Min. 107; DC: Min. 2×107 (at 300 times/min.)
Electrical (at nominal switching capacity) Min. 105 (at 20 times/min.) Min. 105 (at 10 times/min.)
Conditions
Conditions for operation, transport and storage*3
(Not freezing and condensing at low temperature)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 times/min. (at nominal switching capacity) 10 times/min.
(at nominal switching capacity)
Unit weight Approx. 19 g .67 oz Approx. 17 g .60 oz Approx. 19 g .67 oz
HN (AHN)
–4– ASCTB5E 201802-T
REFERENCE DATA
DIMENSIONS (mm inch)
1. Plug-in type 1 Form C
1-(1). Max. switching capacity
(1 Form C and 1 Form A)
1-(2). Max. switching capacity (2 Form C) 2-(1). Coil temperature rise (1 Form C/AC and
1 Form A/AC types)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
10 5020 30 100 250
100
50
30
20
16
10
5
1
0.5
1 Form A and
1 Form C types
AC resistive load
1 Form C type
DC resistive load
1 Form A type DC resistive load
Contact current, A
Contact voltage, V
10
5
1
0.5
0.4
0.3
0.2
10
5020 30
100 250
Contact voltage, V
Contact current, A
AC resistive load
DC resistive load
80 90 100 110 140120 130
0
20
40
60
80
100
120
Coil applied voltage, %V
16A
0A
Temperature rise, °C
2-(2). Coil temperature rise (1 Form C/DC and
1 Form A/DC types)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
2-(3). Coil temperature rise (2 Form C/AC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
2-(4). Coil temperature rise (2 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
80 90 100 110 140120 130
0
10
30
20
40
50
60
70
Coil applied voltage, %V
16A
0A
Temperature rise, °C
80 90 100 110 140120 130
0
20
40
60
80
100
120
Coil applied voltage, %V
Temperature rise, °C
5A
0A
80 90 100 110 140120 130
0
10
30
20
40
50
60
70
Coil applied voltage, %V
5A
0A
Temperature rise, °C
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
4.75
0.5
4.7
7.5
17.5
5.2 5.2
Max. 13 Max. 29
Max. 29
5.3
0.5
.187
.020
.185
.295
.689
.205 .205
Max. .512 Max. 1.142
Max. 1.142
.209
.020
Schematic (Bottom view)
Standard type
5243
1
With LED AC type
With Diode type
With LED DC type
With Diode and LED type
5243
1
5243
1
1
3425
1
3425
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
HN (AHN)
–5– ASCTB5E 201802-T
2. Plug-in type 2 Form C
3. TM type 1 Form A
SAFETY STANDARDS
* CSA standard: Certified by C-UL
** Please consult us.
File No. Certification authority: UL/C-UL File No. Certification authority: VDE
1 Form C E43149* 10A 277V AC, 10A 30V DC, TV-5 40012003 10A 250V AC (cos
φ
=1.0), 10A 30V DC (0ms)
2 Form C E43149* 5A 277V AC, 5A 30V DC, TV-3 40012003 5A 250V AC (cos
φ
=1.0), 5A 30V DC (0ms)
1 Form A (TM type) E43149* 16A 277V AC, 16A 30V DC **
External dimensions
19.4
7.5
Max. 28
Max. 29
Max. 13
6
8.9
0.5 0.52.6 2.6
55
.764
.295
Max. 1.102
Max. 1.142
Max. .512
.236
.020 .020.102 .102
.197 .197
.350
Schematic (Bottom view)
Standard type
3
87 6 5
421
With LED AC type
With Diode type
With LED DC type
With Diode and LED type
12 4
5678
3
12 4
5678
3
12 4
5678
3
12 4
5678
3
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
External dimensions
3
4
2
15
#187 tab terminal
8.5
17.5
7.5
Max. 30
Max. 45
Max. 13
Max. 29
0.5
2.5
3.7
5.2
0.5
4.75
4.75
.335
.389
.295
Max. 1.181
Max. 1.772
Max. .512
Max. 1.142
.020
.098
.146
.205
.020
.187
.187
Notes: 1. When mounting the TM type, since the
cover is made from polycarbonate, please
use a washer in order to prevent damage,
deformation, and loosening.
2. Suitable tightening torque is 0.3 to 0.5 N·m.
Schematic
Mounting hole dimensions
1
543
38
2-M3 or 2-3.5 dia.
1.496
2-.118 or 2-.138 dia.
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
HN (AHN)
–6– ASCTB5E 201802-T
NOTES
1. For cautions for use, please read
“General Application Guidelines” on
page B-1.
2. Coil applied voltage
To ensure proper operation, the voltage
applied to both terminals of the coil
should be ±5% (at 20°C 68°F) the rated
operating voltage of the coil.
Also, be aware that the pick-up and drop-
out voltages will fluctuate depending on
the ambient temperature and operating
conditions.
3. LED indications
The light of the light emitting diode is
what displays operation. If voltage
remains after relay dropout, the LED
might illuminate briefly.
4. Switching lifetime
The switching lifetime is defined under
the standard test condition specified in
the JIS C 5442(*2) standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75% R.H.). Check this with the real
device as it is affected by coil driving
circuit, load type, activation frequency,
activation phase,ambient conditions and
other factors.
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
2) High-frequency load-operating
When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
5. Direct mount type (TM type)
If the current to the connection terminal
will exceed 10 A, we recommend
connecting with solder. If you are going to
use a tab terminal when the current will
exceed 10 A, make sure to verify the
temperature rise on the receptacle side
under actual conditions before using.
Please be careful, because excessive
stress on the TM terminal can cause
fluctuations in characteristics and
damage.
6. Conditions for operation, transport
and storage
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +70°C – 40 to +158°F
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
Temperature and humidity range for
usage, transport, and storage
(3) Atmospheric pressure: 86 to 106 kPa
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
7. Diode characteristics
1) Reverse breakdown voltage:
Min. 1,000V (with diode type)
Min. 400V (with diode and LED indication
type)
8. Diode type
Since the diode inside the relay coil are
designed to absorb the counter emf, the
element may be damaged if a large
surge, etc., is applied to the diode.
If there is the possibility of a large surge
voltage from the outside, please
implement measures to absorb it.
9. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
10. Installation
If you will be installing adjacent to other
relays, please keep a distance of at least
5 mm from the relay.
Humidity, %R.H.
Tolerance range
85
5
070–40 +32 +158–40
(Avoid
condensation
when used at
temperatures
higher than
0°C
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
Temperature, °C°F
32°F)