G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments * A wide variety of single pole, double pole and high-capacity type Relays are available. * High sensitivity with power consumption of 400 mW. * Offers high insulation with insulation distance above 8 mm and impulse withstand voltage of 10kV between coil and contacts. * Satisfies ambient operating temperature requirement of 85C. * Standard model conforms to VDE standards. RoHS Compliant Model Number Legend Application Examples G2RL-@@@-@ ------ -- 1 2 3 1. Number of 2. Contact 3. Enclosure rating 4. Classification Poles Form None : Flux protection None : Standard 4 1: 1-pole 4 : Fully sealed E : High-capacity None : NO/NC 2: 2-pole A : NO * Home appliances * OA equipments * Industrial machinery G 2 R L Ordering Information Classification Contact form Terminal Shape SPST-NO (1a) SPDT (1c) Standard DPST-NO (2a) PCB terminals DPDT (2c) SPST-NO (1a) High-capacity SPDT (1c) Enclosure rating Flux protection Fully sealed Flux protection Fully sealed Flux protection Fully sealed Flux protection Fully sealed Flux protection Fully sealed Flux protection Fully sealed Model G2RL-1A G2RL-1A4 G2RL-1 G2RL-14 G2RL-2A G2RL-2A4 G2RL-2 G2RL-24 G2RL-1A-E G2RL-1A4-E G2RL-1-E G2RL-14-E Rated coil voltage Minimum packing unit 5 VDC 12 VDC 24 VDC 48 VDC 20 pcs/tube Note 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A 5 VDC Rated coil voltage Note 2. Place your order in tube (20 pcs/tube) units. Note 3. Contact your OMRON sales representative for fully sealed models. Ratings Coil Item Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC Rated current (mA) 80.0 33.3 16.7 8.96 Coil resistance () Must operate voltage Must release voltage (V) (V) % of rated voltage 62.5 360 1,440 5,358 75% max. 10% min. Max. voltage (V) Power consumption (mW) Approx. 400 130% (at 85C) Approx. 430 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The "Max. voltage" is the maximum voltage that can be applied to the relay coil. Contacts Item Contact type Contact material Classification Model Rated load Rated carry current Max. switching voltage Max. switching current Failure rate (P level) (reference value*) General-purpose Models (resistive load) G2RL-1 G2RL-2A G2RL-2 Single Ag-alloy (Cd free) 12 A at 250 VAC 8 A at 250 VAC 12 A at 24 VDC (See note) 8 A at 30 VDC (See note) 12 A (See note) 8 A (70C)/5 A (85C) (See note) 440 VAC, 300 VDC 12 A 8A G2RL-1A High-capacity Models (resistive load) G2RL-1A-E G2RL-1-E 16 A at 250 VAC 16 A at 24 VDC (See note) 16 A (See note) 16 A 40 mA at 24 VDC * This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on fully sealed models. 1 G2RL PCB Power Relay Characteristics Classification Item Number of poles Contact resistance *1 Operate (set) time Release (reset) time Max. Mechanical operating frequency Electrical High-capacity Models 1-pole 2-pole 100 m max. 15 ms max. 5 ms max. 18,000 operation/hr 1,800 operation/hr Insulation resistance *2 1,000 M min. Between coil and 5,000 VAC, 50/60 Hz for 1min contacts Between contacts Dielectric of the same 1,000 VAC, 50/60 Hz for 1min strength polarity Between contacts - 2,500 VAC, 50/60 Hz for 1min - of different polarity Insulation Between coil and Clearance: 8 mm, Creepage: 8 mm distance contacts Impulse withstand voltage 10 kV (1.2 x 50 s) Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s2 Shock resistance Malfunction Energized: 100 m/s2, De-energized: 100 m/s2 Mechanical 20,000,000 operations (at 18,000 operations/hr) Durability Electrical *3 G2RL-1(A): 50,000 operations at 250 VAC, 12 A G2RL-2(A): 30,000 operations at 250 VAC, 8 A G2RL-1(A)-E: 30,000 operations at 250 VAC, 16 A (resistive load) 30,000 operations at 24 VDC, 12 A 30,000 operations at 30 VDC, 8 A 30,000 operations at 24 VDC, 16 A Ambient operating temperature -40C to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% (with no icing or condersation) Weight Approx. 12 g Note. Values in the above table are the initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour. Engineering Data AC resistive load 10 5 G2RL-2A, G2RL-2 50 AC resistive load 10 5 50 5 DC resistive load 1 1 1 0.5 0.5 0.5 0.1 0.1 0.1 0 5 10 20 30 50 100 0 500 1,000 5 10 20 30 50 100 Ambient Temperature vs. Maximum Coil Voltage Ambient Temperature vs. Must Operate and Must Release Voltages Must operate/must release voltage (percentage of rated voltage) (%) 250 200 180 150 130 100 500 1,000 Switching voltage (V) Switching voltage (V) 100 Sample: 90 G2RL-14-E 24 VDC Number of relays: 5 pcs 80 Must operate voltage Must release voltage max. X min. 70 60 50 40 max. X min. 30 20 50 10 0 10 20 30 40 50 60 70 AC resistive load 10 DC resistive load DC resistive load 80 85 90 100 Ambient temperature (C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. 2 Switching current (A) 50 G2RL-1A-E, G2RL-1-E Switching current (A) Switching current (A) Maximum Switching Capacity G2RL-1A, G2RL-1 Maximum coil voltage (%) G 2 R L General-purpose Models 1-pole 0 20 40 60 80 100 120 Ambient temperature (C) 0 5 10 20 30 50 100 500 1,000 Switching voltage (V) G2RL PCB Power Relay Shock Malfunction G2RL-1 (A)-E Y NO contact G2RL-2 (A) Y 1,000 NO contact X' 1,000 Sample: G2RL-14 12 VDC Number of Relays: 5 pcs X' Test conditions: Shock is applied 1,000 in X, Y, and Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 1,000 100 m/s2 Z 1,000 130 1,000 Z' 1,000 X NC contact 1,000 Y' Z 1,000 150 1,000 X NC contact Z' Y 1,000 Shock direction X X' Y Z Z' Unit: m/s2 Sample: G2RL-24 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in X, Y, and Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 1,000 Y' Shock direction X X' Z Z' Unit: m/s2 Y' Y' Dimensions (Unit: mm) G2RL-1A, G2RL-1A4 PCB Mounting Holes (Bottom View) 3.5 12.7 max. (12.5)* 29 max. (28.8)* Four, 1.3-dia. holes Terminal Arrangement/ Internal Connections (Bottom View) (2.5) 1 3 G 2 R L 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 * Average value G2RL-1, G2RL-14 PCB Mounting Holes (Bottom View) 3.5 3.5 12.7 max. (12.5)* 29 max. (28.8)* Five, 1.3-dia. holes Terminal Arrangement/ Internal Connections (Bottom View) (2.5) 1 2 3 7.5 15.7 max. (15.5)* 5 (2.3) 0.5 3.5 0.5 20 4 (No coil polarity) 0.8 0.5 0.5 * Average value G2RL-1A-E, G2RL-1A4-E PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes Terminal Arrangement/ Internal Connections (Bottom View) (2.5) 1 3 4 6 5 7.5 15.7 max. (15.5)* 8 (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 * Average value G2RL-1-E, G2RL-14-E PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* 5 Eight, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 * Average value 3 G2RL PCB Power Relay G2RL-2A, G2R-2A4 PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* Six, 1.3-dia. holes (2.5) Terminal Arrangement/ Internal Connections (Bottom View) 1 3 4 8 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 * Average value G2RL-2, G2R-24 PCB Mounting Holes (Bottom View) 5 12.7 max. (12.5)* 29 max. (28.8)* 5 Terminal Arrangement/ Internal Connections (Bottom View) Eight, 1.3-dia. holes (2.5) 1 2 3 4 8 7 6 5 7.5 15.7 max. (15.5)* (2.3) 0.5 3.5 0.5 20 (No coil polarity) 0.8 0.5 0.5 G 2 R L * Average value Approved Standards * The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. UL Recognized: CSA Certified: (File No. 41643) (File No. LR31928) Model Contact form G2RL-1A G2RL-1 G2RL-1A-E G2RL-1-E G2RL-2A G2RL-2 SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPDT (1c) DPST-NO (2a) DPDT (2c) Coil ratings 5 to 48 VDC Contact form G2RL-1A SPST-NO (1a) G2RL-1 SPDT (1c) G2RL-1A-E SPST-NO (1a) G2RL-1-E SPDT (1c) G2RL-2A DPST-NO (2a) G2RL-2 DPDT (2c) 12 A, 250 VAC (General Use) 40C 12 A, 24 VDC (Resistive) 40C 16 A, 250 VAC (General Use) 40C 16 A, 24 VDC (Resistive) 40C 8 A, 277 VAC (General Use) 40C 8 A, 30 VDC (Resistive) 40C EN/IEC, VDE Certified Model Number of test operations 100,000 50,000 100,000 50,000 Contact ratings 100,000 (Registration No. 119650) Coil ratings 5, 12, 24, 48 VDC Number of test operations Contact ratings 12 A, 250 VAC (cos=1) 85C 12 A, 24 VDC (L/R=0 ms) 85C AC15: 3 A at 240 VAC at room temperature DC13: 2.5 A at 24 VDC, 50ms at room temperature 16 A, 250 VAC (cos=1) 85C 16 A, 24 VDC (L/R=0 ms) 85C AC15: 3 A at 240 VAC (NO) at room temperature, 1.5 A at 240V AC (NC) at room temperature DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature 8 A, 250 VAC (cos=1) 85C 8 A, 30 VDC (L/R=0 ms) 85C AC15: 1.5 A at 240VAC at room temperature DC13: 2 A at 30 VDC, 50ms at room temperature 100,000 6,000 30,000 15,000 6,000 30,000 15,000 6,000 Precautions * Please refer to "PCB Relays Common Precautions" for correct use. Correct Use Mounting Position Compared to G2R Model * Although the G2RL model and the G2R model are both low profile Relays, their characteristics such as switching capacity are different. Be sure to check operation under the actual operating conditions before use. 4 Cleaning * The G2RL model is flux-resistant with two sealing holes on the case. Thus, do not clean the Relay by boiling or soaking in water. Consult your Omron sales representative for sealed type Relay. Using Relays in an Atmosphere Containing Corrosive Gas * Do not use Relays in an atmosphere containing corrosive gas (sulfuric or organic gas).Otherwise, connection failure due to corrosion on the contact surface may lead to functional faults. G2RL PCB Power Relay G 2 R L * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J117-E1-07 1014(0207)(O) 5