Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Lxx06xx & Qxx06xx & Qxx06xHx Series (R) Description 6 Amp bi-directional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls, lighting controls, and static switching relays. Sensitive type devices guarantee gate control in Quadrants I & IV needed for digital control circuitry. Standard type devices normally operate in Quadrants I & III triggered from AC line. Alternistor type devices only operate in quadrants I, II, & III and are used in circuits requiring high dv/dt capability. Features & Benefits * RoHS compliant Agency Approval Agency Agency File Number * Voltage capability up to 1000 V L Package: E71639 (R) contact bounce that create voltage transients * Glass - passivated junctions * Surge capability up to 85 A Main Features Symbol IT(RMS) VDRM /VRRM IGT (Q1) Value Unit 6 A 400 to 1000 V 5 to 50 mA * Electrically isolated "L - Package" is UL recognized for 2500Vrms * Solid-state switching eliminates arcing or *N o contacts to wear out from reaction of switching events *R estricted (or limited) RFI generation, depending on activation point of sine wave *R equires only a small gate activation pulse in each half-cycle Applications Excellent for AC switching and phase control applications such as heating, lighting, and motor speed controls. Schematic Symbol Typical applications are AC solid-state switches, light dimmers, power tools, home/brown goods and white goods appliances. MT2 Alternistor Triacs (no snubber required) are used in applications with extremely inductive loads requiring highest commutation performance. MT1 Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage. G Absolute Maximum Ratings -- Sensitive Triac (4 Quadrants) Symbol IT(RMS) ITSM I 2t Parameter RMS on-state current (full sine wave) Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) IGTM I2t Value for fusing Critical rate of rise of on-state current IG = 50mA with 0.1s rise time Peak gate trigger current PG(AV) Average gate power dissipation di/dt Tstg TJ Value Unit 6 A Lxx06Ly Lxx06Vy / Lxx06Dy/ Lxx06Ry f = 50 Hz f = 60 Hz tp = 8.3 ms TC = 80C TC = 85C t = 20 ms t = 16.7 ms f = 120 Hz TJ = 110C tp 10 s TJ = 110C 1.6 A TJ = 110C 0.4 W -40 to 150 -40 to 110 C C Storage temperature range Operating junction temperature range 50 60 15 A2s 70 A/s Note: xx = voltage, y = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 61 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. A Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Absolute Maximum Ratings -- Standard Triac Symbol Parameter RMS on-state current (full sine wave) IT(RMS) ITSM Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) I2t I2t Value for fusing Value Unit 6 A Qxx06Ry / Qxx06Ny TC = 95C Qxx06Ly TC = 90C f = 50 Hz t = 20 ms 65 f = 60 Hz t = 16.7 ms 80 tp = 8.3 ms A 26.5 A2s di/dt Critical rate of rise of on-state current IG = 200mA with 0.1s rise time f = 120 Hz TJ = 125C 70 A/s IGTM Peak gate trigger current tp 10 s; IGT IGTM TJ = 125C 1.6 A PG(AV) Average gate power dissipation TJ = 125C 0.5 W Storage temperature range -40 to 150 C Operating junction temperature range -40 to 125 C Tstg TJ Note: xx = voltage, y = sensitivity Absolute Maximum Ratings -- Alternistor Triac (3 Quadrants) Symbol IT(RMS) Parameter RMS on-state current (full sine wave) Qxx06LHy TC = 95C Qxx06RHy / Qxx06NHy Qxx06VHy / Qxx06DHy TC = 100C f = 50 Hz ITSM t = 20 ms Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) f = 60 Hz I 2t I2t Value for fusing t = 16.7 ms tp = 8.3 ms Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Value Unit 6 A 55 80 A 65 85 17.5 A 2s 30 di/dt Critical rate of rise of on-state current f = 120 Hz TJ = 125C 70 A/s IGTM Peak gate trigger current tp 10 s; IGT IGTM TJ = 125C 1.6 A PG(AV) Average gate power dissipation TJ = 125C 0.5 W Storage temperature range -40 to 150 C Operating junction temperature range -40 to 125 C Tstg TJ Note: xx = voltage, y = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 62 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Sensitive Triac (4 Quadrants) Symbol IGT VGT Test Conditions Value Quadrant VD = 12V RL = 60 I - II - III IV MAX. ALL MAX. Lxx06x5 Lxx06x6 Lxx06x8 5 5 5 10 10 20 mA 1.3 VGD VD = VDRM RL = 3.3 k TJ = 110C IH IT = 100mA dv/dt VD = VDRM Gate Open TJ = 100C (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 110C TYP. 1 tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 3.0 ALL Unit MIN. V 0.2 V MAX. 10 10 20 mA TYP. 30 20 30 20 40 30 V/s 2 2 V/s 3.0 3.2 s 400V 600V Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Standard Triac Symbol IGT VGT Test Conditions VD = 12V RL = 60 VGD VD = VDRM RL = 3.3 k TJ = 125C IH IT = 200mA Value Quadrant Qxx06x4 25 50 MAX. TYP. I - II - III MAX. 1.3 V ALL MIN. 0.2 V 50 400V dv/dt 600V 800V VD = VDRM Gate Open TJ = 100C Unit I - II - III IV MAX. VD = VDRM Gate Open TJ = 125C Qxx06x5 50 75 50 mA mA 120 100 MIN. V/s 85 1000V 100 (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 125C TYP. 4 4 V/s tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 3.0 3.0 s Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Alternistor Triac (3 Quadrants) Symbol IGT VGT Test Conditions VD = 12V RL = 60 VGD VD = VDRM RL = 3.3 k TJ = 125C IH IT = 100mA I - II - III MAX. I - II - III MAX. I - II - III 10 MIN. Qxx06LHy / Qxx06RHy / Qxx06NHy VD = VDRM Gate Open TJ = 100C MIN. ALL Unit mA V 0.2 V 15 35 400V 75 400 600V 50 300 800V VD = VDRM Gate Open TJ = 125C 35 1.3 MAX. Qxx06VHy / Qxx06DHy dv/dt Value Qxx06xH3 Qxx06xH4 Quadrant mA 200 400V 75 450 600V 50 350 800V 250 1000V 150 V/s (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 125C MIN. 20 25 V/s tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 4.0 4.0 s Note: xx = voltage, x = package, y = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 63 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Static Characteristics Symbol Test Conditions ITM = 11.3A tp = 380 s VTM Lxx06xy Qxx06xy IDRM / IRRM VDRM = VRRM MAX. Unit 1.60 V TJ = 25C 400 - 600V 20 A TJ = 110C 400 - 600V 0.5 mA TJ = 25C 400 - 1000V 50 A TJ = 125C 400 - 800V 2 TJ = 100C 1000V MAX. mA 3 400 - 800V 10 1000V 20 TJ = 125C 400 - 800V 3 TJ = 100C 1000V 2 TJ = 25C Qxx06xHy Value A mA Thermal Resistances Symbol Parameter Value L/Qxx06Ryy / L/Qxx06Nyy 1.8 L/Qxx06Lyy 3.3 L/Qxx06Vyy / L/Qxx06Dyy 3.2 L/Qxx06Ryy 45 L/Qxx06Lyy 50 L/Qxx06Vyy 70 Junction to case (AC) R(J-C) Junction to ambient R(J-A) Unit C/W C/W Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity Figure 2: N ormalized DC Gate Trigger Current for All Quadrants vs. Junction Temperature Figure 1: Definition of Quadrants ALL POLARITIES ARE REFERENCED TO MT1 + (+) I GT GATE MT1 I GT REF (-) MT1 I GT GATE (+) MT1 REF REF QII QI QIII QIV MT2 IGT I GT GATE 4.0 MT2 - + IGT IGT (TJ = 25C) (-) MT2 POSITIVE (Positive Half Cycle) Ratio of MT2 MT2 3.0 2.0 1.0 I GT GATE MT2 NEGATIVE (Negative Half Cycle) 0.0 MT1 -65 REF -40 -15 10 35 60 85 110 Junction Temperature (TJ)- C NOTE: Alternistors will not operate in QIV Note: Alternistors will not operate in QIV Lxx06xx & Qxx06xx & Qxx06xHx Series 64 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 125 Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 3: Normalized DC Holding Current vs. Junction Temperature Figure 4: N ormalized DC Gate Trigger Voltage for All Quadrants vs. Junction Temperature VGT 3.0 2.0 VGT (TJ = 25C) 2.0 1.5 1.0 Ratio of IH Ratio of IH (TJ = 25C) 4.0 1.0 0.5 0.0 0.0 -65 -40 -15 10 35 60 85 110 -65 125 -40 Junction Temperature (TJ)- C 35 60 85 110 125 Figure 6: M aximum Allowable Case Temperature vs. On-State Current (Sensitive Triac) 120 Maximum Allowable Case Temperature (TC) - C 18 Average On-State Power Dissipation (PD(AV)) - Watts 10 Junction Temperature (TJ)- C Figure 5: Power Dissipation (Typical) vs. RMS On-State Current 16 14 110 Lxx06Vy Lxx06Dy Lxx06Ry 100 12 10 8 6 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 4 2 0 0 2 4 6 8 10 12 14 16 90 Lxx06Ly 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 60 0 1 RMS On-State Current (IT(RMS)) - Amps 2 3 4 5 6 7 RMS On-State Current (IT(RMS)) - Amps Figure 7: Maximum Allowable Case Temperature vs. On-State Current (Standard Triac) Figure 8: M aximum Allowable Case Temperature vs. On-State Current (Alternistor Triac) 130 Maximum Allowable Case Temperature (TC) - C 130 Maximum Allowable Case Temperature (TC) - C -40 120 Qxx06Ry Qxx06Ny 110 100 Qxx06Ly 90 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy 120 110 100 Qxx06LHy 90 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 60 60 0 1 2 3 4 5 6 7 RMS On-State Current (IT(RMS)) - Amps Lxx06xx & Qxx06xx & Qxx06xHx Series 0 1 2 3 4 5 6 RMS On-State Current (IT(RMS)) - Amps 65 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 7 Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 9: Maximum Allowable Ambient Temperature vs. On-State Current (Sensitive / Standard Triac) Figure 10: Maximum Allowable Ambient Temperature vs. On-State Current (Alternistor Triac) 120 Maximum Allowable Ambient Temperature (TA) - C Maximum Allowable Ambient Temperature (TA) - C 120 100 Lxx06Ly Lxx06Ry 80 Qxx06Ly Qxx06Ry Qxx06Ny L/Qxx06Vy 60 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 FREE AIR RATING - NO HEATSINK 40 20 100 Qxx06LHy Qxx06RHy Qxx06NHy 80 Qxx06VHy 60 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawing 40 20 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RMS On-State Current (IT(RMS)) - Amps 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 RMS On-State Current [IT(RMS)] - Amps Figure 11: On-State Current vs. On-State Voltage (Typical) Postitive or Negative Instantaneous On-State Current (iT) - Amps 20 TC = 25C 18 16 14 12 10 8 6 4 2 0 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Postitive or Negative Instantaneous On-State Voltage (vT) - Volts Lxx06xx & Qxx06xx & Qxx06xHx Series 66 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 2.0 Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 12: Surge Peak On-State Current vs. Number of Cycles (Sensitive / Standard Triac) 100 SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified Case Temperature Peak Surge (Non-Repetitive) On-State Current (ITSM) - Amps Qxx06Ly Qxx06Ry Qxx06Ny Notes: 1. G ate control may be lost during and immediately following surge current interval. 2. O verload may not be repeated until junction temperature has returned to steady-state rated value. Lxx06Ly Lxx06Ry Lxx06Vy Lxx06Dy 10 1 1 10 100 1000 Surge Current Duration- Full Cycles Figure 13: Surge Peak On-State Current vs. Number of Cycles (Alternistor Triac) 100 SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified Case Temperature Peak Surge (Non-Repetitive) On-State Current (ITSM) - Amps Qxx06LHy Qxx06RHy Qxx06NHy Notes: 1. G ate control may be lost during and immediately following surge current interval. 2. O verload may not be repeated until junction temperature has returned to steady-state rated value. Qxx06VHy Qxx06DHy 10 1 1 10 100 1000 Surge Current Duration- Full Cycles Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 67 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Soldering Parameters Pb - Free assembly Pre Heat - Temperature Min (Ts(min)) 150C - Temperature Max (Ts(max)) 200C - Time (min to max) (ts) 60 - 180 secs Average ramp up rate (Liquidus Temp) (TL) to peak 5C/second max TS(max) to TL - Ramp-up Rate 5C/second max Reflow - Temperature (TL) (Liquidus) 217C - Temperature (tL) 60 - 150 seconds 260+0/-5 C Time within 5C of actual peak Temperature (tp) 20 - 40 seconds Ramp-down Rate 5C/second max Time 25C to peak Temperature (TP) 8 minutes Max. Do not exceed 280C Physical Specifications Terminal Finish Ramp-up TL tL TS(max) Preheat TS(min) 25 Peak Temperature (TP) tP TP Temperature Reflow Condition tS time to peak temperature Time Environmental Specifications Test 100% Matte Tin-plated AC Blocking (VDRM) Body Material UL recognized epoxy meeting flammability classification 94V-0 Terminal Material Copper Alloy Temperature Cycling Temperature/ Humidity Design Considerations High Temp Storage Careful selection of the correct device for the application's operating parameters and environment will go a long way toward extending the operating life of the Thyristor. Good design practice should limit the maximum continuous current through the main terminals to 75% of the device rating. Other ways to ensure long life for a power discrete semiconductor are proper heat sinking and selection of voltage ratings for worst case conditions. Overheating, overvoltage (including dv/dt), and surge currents are the main killers of semiconductors. Correct mounting, soldering, and forming of the leads also help protect against component damage. Low-Temp Storage Lxx06xx & Qxx06xx & Qxx06xHx Series Ramp-do Ramp-down 68 Revised: June 24, 2011 04:57 PM Thermal Shock Autoclave Specifications and Conditions MIL-STD-750, M-1040, Cond A Applied Peak AC voltage @ 125C for 1008 hours MIL-STD-750, M-1051, 100 cycles; -40C to +150C; 15-min dwell-time EIA / JEDEC, JESD22-A101 1008 hours; 320V - DC: 85C; 85% rel humidity MIL-STD-750, M-1031, 1008 hours; 150C 1008 hours; -40C MIL-STD-750, M-1056 10 cycles; 0C to 100C; 5-min dwelltime at each temperature; 10 sec (max) transfer time between temperature EIA / JEDEC, JESD22-A102 168 hours (121C at 2 ATMs) and 100% R/H Resistance to Solder Heat MIL-STD-750 Method 2031 Solderability ANSI/J-STD-002, category 3, Test A Lead Bend MIL-STD-750, M-2036 Cond E (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-220AB (R-Package) -- Non-Isolated Mounting Tab Common with Center Lead TC MEASURING POINT O A O E AREA (REF.) 0.17 IN2 Dimension 8.13 .320 P MT2 B C 13.36 .526 D 7.01 .276 NOTCH IN GATE LEAD TO ID. NON-ISOLATED TAB F R G L H N K J Note: Maximum torque to be applied to mounting tab is 8 in-lbs, (0.904 Nm). M MT1 MT2 GATE Inches Millimeters Min Max Min Max A 0.380 0.420 9.65 10.67 B 0.105 0.115 2.67 2.92 C 0.230 0.250 5.84 6.35 D 0.590 0.620 14.99 15.75 E 0.142 0.147 3.61 3.73 F 0.110 0.130 2.79 3.30 G 0.540 0.575 13.72 14.61 H 0.025 0.035 0.64 0.89 J 0.195 0.205 4.95 5.21 K 0.095 0.105 2.41 2.67 L 0.060 0.075 1.52 1.91 M 0.085 0.095 2.16 2.41 N 0.018 0.024 0.46 0.61 O 0.178 0.188 4.52 4.78 P 0.045 0.060 1.14 1.52 R 0.038 0.048 0.97 1.22 Min Max Min Max Dimensions -- TO-220AB (L-Package) -- Isolated Mounting Tab TC MEASURING POINT O A O E P AREA (REF.) 0.17 IN2 Dimension 8.13 .320 B C 13.36 .526 D 7.01 .276 F R G L H K N J MT1 MT2 GATE Lxx06xx & Qxx06xx & Qxx06xHx Series M Note: Maximum torque to be applied to mounting tab is 8 in-lbs, (0.904 Nm). 69 Revised: June 24, 2011 04:57 PM Inches Millimeters A 0.380 0.420 9.65 10.67 B 0.105 0.115 2.67 2.92 C 0.230 0.250 5.84 6.35 D 0.590 0.620 14.99 15.75 E 0.142 0.147 3.61 3.73 F 0.110 0.130 2.79 3.30 G 0.540 0.575 13.72 14.61 H 0.025 0.035 0.64 0.89 J 0.195 0.205 4.95 5.21 K 0.095 0.105 2.41 2.67 L 0.060 0.075 1.52 1.91 M 0.085 0.095 2.16 2.41 N 0.018 0.024 0.46 0.61 O 0.178 0.188 4.52 4.78 P 0.045 0.060 1.14 1.52 R 0.038 0.048 0.97 1.22 (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-263AB (N-Package) -- D2-PAK Surface Mount TC MEASURING POINT B Dimension AREA: 0.11 IN2 C V E MT2 7.01 .276 A 8.41 .331 S W U G J K GATE MT1 8.13 .320 H D F 11.68 .460 2.16 .085 7.01 .276 7.01 .276 16.89 .665 8.89 .350 1.40 .055 3.81 .150 2.03 .080 Inches Min Millimeters Max Min Max A 0.360 0.370 9.14 9.40 B 0.380 0.420 9.65 10.67 C 0.178 0.188 4.52 4.78 D 0.025 0.035 0.64 0.89 E 0.045 0.060 1.14 1.52 F 0.060 0.075 1.52 1.91 G 0.095 0.105 2.41 2.67 H 0.092 0.102 2.34 2.59 J 0.018 0.024 0.46 0.61 K 0.090 0.110 2.29 2.79 S 0.590 0.625 14.99 15.88 V 0.035 0.045 0.89 1.14 U 0.002 0.010 0.05 0.25 W 0.040 0.070 1.02 1.78 6.60 .260 Dimensions -- TO-251AA (V-Package) -- V-PAK Through Hole TC MEASURING POINT MT2 E H D AREA: 0.040 IN2 Dimension 5.28 .208 J A 5.34 .210 B R P Q S K C MT1 MT2 GATE F L G I Lxx06xx & Qxx06xx & Qxx06xHx Series 70 Revised: June 24, 2011 04:57 PM Inches Millimeters Min Typ Max Min Typ Max A 0.040 0.044 0.050 1.02 1.11 1.27 B 0.235 0.242 0.245 5.97 6.15 6.22 C 0.350 0.361 0.375 8.89 9.18 9.53 D 0.205 0.208 0.213 5.21 5.29 5.41 E 0.255 0.262 0.265 6.48 6.66 6.73 F 0.027 0.031 0.033 0.69 0.80 0.84 G 0.087 0.090 0.093 2.21 2.28 2.36 H 0.085 0.092 0.095 2.16 2.34 2.41 I 0.176 0.180 0.184 4.47 4.57 4.67 J 0.018 0.020 0.023 0.46 0.51 0.58 K 0.038 0.040 0.044 0.97 1.01 1.12 L 0.018 0.020 0.023 0.46 0.52 0.58 P 0.042 0.047 0.052 1.06 1.20 1.32 Q 0.034 0.039 0.044 0.86 1.00 1.11 R 0.034 0.039 0.044 0.86 1.00 1.11 S 0.074 0.079 0.084 1.86 2.00 2.11 (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-252AA (D-Package) -- D-PAK Surface mount MT2 E D 6.71 .264 5.28 .208 TC MEASURING POINT Dimension 6.71 .264 B C P Q MT1 GATE F MT2 1.60 .063 1.80 .071 AREA : 0.040 IN2 3 .118 G 4.60 .181 I O L K J H M N Lxx06xx & Qxx06xx & Qxx06xHx Series 71 Revised: June 24, 2011 04:57 PM Millimeters Min Typ Max Min Typ Max A 0.040 0.043 0.050 1.02 1.09 1.27 B 0.235 0.243 0.245 5.97 6.16 6.22 C 0.106 0.108 0.113 2.69 2.74 2.87 A 5.34 .210 Inches D 0.205 0.208 0.213 5.21 5.29 5.41 E 0.255 0.262 0.265 6.48 6.65 6.73 F 0.027 0.031 0.033 0.69 0.80 0.84 G 0.087 0.090 0.093 2.21 2.28 2.36 H 0.085 0.092 0.095 2.16 2.33 2.41 I 0.176 0.179 0.184 4.47 4.55 4.67 J 0.018 0.020 0.023 0.46 0.51 0.58 K 0.038 0.040 0.044 0.97 1.02 1.12 L 0.018 0.020 0.023 0.46 0.51 0.58 M 0.000 0.000 0.004 0.00 0.00 0.10 N 0.021 0.026 0.027 0.53 0.67 0.69 O 0 0 5 0 0 5 P 0.042 0.047 0.052 1.06 1.20 1.32 Q 0.034 0.039 0.044 0.86 1.00 1.11 (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Product Selector Part Number Voltage 400V 600V Lxx06L5 X Lxx06D5 Lxx06R5 800V Gate Sensitivity Quadrants 1000V Type Package 5 mA Sensitive Triac TO-220L 5 mA 5 mA Sensitive Triac TO-252 D-PAK 5mA 5mA Sensitive Triac TO-220R 5 mA Sensitive Triac TO-251 V-PAK 10 mA Sensitive Triac TO-220L I - II - III IV X 5 mA X X X X Lxx06V5 X X 5 mA Lxx06L6 X X 5 mA Lxx06D6 X X 5 mA 10 mA Sensitive Triac TO-252 D-PAK Lxx06R6 X X 5mA 10mA Sensitive Triac TO-220R Lxx06V6 X X 5 mA 10 mA Sensitive Triac TO-251 V-PAK Lxx06L8 X X 10 mA 20 mA Sensitive Triac TO-220L Lxx06D8 X X 10 mA 20 mA Sensitive Triac TO-252 D-PAK Lxx06R8 X X 10mA 20mA Sensitive Triac TO-220R Lxx06V8 X X 10 mA 20 mA Sensitive Triac TO-251 V-PAK Qxx06VH3 X X 10 mA Alternistor Triac TO-251 V-PAK Qxx06DH3 X X 10 mA Alternistor Triac TO-252 D-PAK Qxx06L4 X 25 mA Standard Triac TO-220L Qxx06R4 X 25 mA Standard Triac TO-220R Qxx06N4 X 25 mA Standard Triac TO-263 D-PAK 10mA Alternistor Triac TO-220R 35 mA Alternistor Triac TO-220L Qxx06RH3 X X Qxx06LH4 X X X X Qxx06RH4 X X X X 35 mA Alternistor Triac TO-220R Qxx06VH4 X X X X 35 mA Alternistor Triac TO-251 V-PAK Qxx06DH4 X X X X 35 mA Alternistor Triac TO-252 D-PAK Qxx06NH4 X X X X 35 mA Alternistor Triac TO-263 D-PAK Qxx06L5 X X X 50 mA Standard Triac TO-220L Qxx06R5 X X X 50 mA Standard Triac TO-220R Qxx06N5 X X X 50 mA Standard Triac TO-263 D-PAK Packing Options Part Number Marking Weight Packing Mode Base Quantity Lxx06L/Ry Lxx06L/Ry 2.2 g Bulk 500 Lxx06L/RyTP Lxx06L/Ry 2.2 g Tube Pack 500 (50 per tube) Lxx06DyTP Lxx06Dy 0.3 g Tube 750 (75 per tube) Lxx06DyRP Lxx06Dy 0.3 g Embossed Carrier 2500 Lxx06VyTP Lxx06Vy 0.4 g Tube 750 (75 per tube) Qxx06L/Ryy Qxx06L/Ryy 2.2 g Bulk 500 Qxx06L/RyyTP Qxx06L/Ryy 2.2 g Tube Pack 500 (50 per tube) Qxx06NyyTP Qxx06Nyy 1.6 g Tube 500 (50 per tube) Qxx06NyyRP Qxx06Nyy 1.6 g Embossed Carrier 500 Qxx06DyyTP Qxx06Dyy 0.3 g Tube 750 (75 per tube) Qxx06DyyRP Qxx06Dyy 0.3 g Embossed Carrier 2500 Qxx06VyyTP Qxx06Vyy 0.4 g Tube 750 (75 per tube) Note: xx = voltage; yy = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 72 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs TO-252 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards * Cover tape 0.315 (8.0) MT1 XXXXXX DC 0.059 DIA (1.5) XX DC XX XXXXXX * XX 0.524 (13.3) XXXXXX 0.63 (16.0) DC Gate XXXXXX 0.157 (4.0) MT2 12.99 (330.0) 0.512 (13.0) Arbor Hole Dia. Dimensions are in inches (and millimeters). 0.64 (16.3) Direction of Feed TO-263 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards 0.63 (16.0) 0.157 (4.0) 0.059 DIA (1.5) 0.945 (24.0) 0.827 (21.0) Gate MT1 * * Cover tape MT2 12.99 (330.0) 0.512 (13.0) Arbor Hole Dia. Dimensions are in inches (and millimeters). 1.01 (25.7) Direction of Feed Lxx06xx & Qxx06xx & Qxx06xHx Series 73 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Part Numbering System Part Marking System Q 60 06 L H4 56 CURRENT 06: 6A PACKAGE TYPE L : TO-220 Isolated R : TO-220 Non-Isolated N : TO-263 (D2PAK) V : TO-251 (VPAK) D : TO-252 (DPAK) Q6006R5 YM L6006V5 (R) SENSITIVITY & TYPE Sensitive Triac: 3 : 3 mA (QI, II, III, IV) 5 : 5 mA (QI, II, III, IV) 6 : 5 mA (QI, II, III) 10 mA (QIV) 8 : 10 mA (QI, II, III) 20 mA (QIV) Standard Triac: 4 : 25 mA (QI, II, III) 5 : 50 mA (QI, II, III) Alternistor Triac: H3 : 10 mA (QI, II, III) H4 : 35 mA (QI, II, III) (R) VOLTAGE RATING 40 : 400V 60 : 600V 80 : 800V K0 : 1000V TO-252AA - (D Package) TO-251AA - (V Package) LEAD FORM DIMENSIONS xx : Lead Form Option YMLDD DEVICE TYPE L : Sensitive Triac Q : Triac or Alternistor (R) MY (R) (R) Lxx06xx & Qxx06xx & Qxx06xHx Series 74 Revised: June 24, 2011 04:57 PM (c)2011 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.