SPECIFICATION
PD-45A PD-45B
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
ACCURRENT (Typ.)
5V 12V
CH2
5V
CH1
24V
CH2
3.2A 2A 3.2A 1.2A
0.4~5A 0.2~2.5A 0.4~5A 0.2~1.8A
40W 44.8W
Ratedoutputpowerforconvection;52Wwith18CFMmin.Forcedair
50mVp-p 120mVp-p 150mVp-p50mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V
4.0% 7.0% 7.0%4.0%
1.0% 2.0% 2.0%1.0%
3.0% 4.0% 4.0%3.0%
800ms,20msatfullload
60msatfullload
90~264VAC127~370VDC
47~440Hz
77% 78%
1A/115VAC0.7A/230VAC
COLDSTART 15A/115VAC30A/230VAC
<0.75mA
53~75W ratedoutputpower
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.04%/ (0~50 )on+5Voutput
10~500Hz,2G10min./1cycle,Periodfor60min.eachalongX, Y,Zaxes
288.1Khrsmin.MIL-HDBK-217F(25 )
127*76*28mm(L*W*H)
0.2Kg;72pcs/16Kg/1.35CUFT
FileName:PD-45-SPEC 2007-03-14
5.75~6.75VDConCH1
OVERVOLTAGE
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN55024,Lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
45WDualOutputSwitchingPowerSupply
Features :
PD-45 series
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
EMICONDUCTION&RADIATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
Universal AC input/Full range
Low leakage current<0.75mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
OUTPUTPOWER(max.)
UL60950-1, TUVEN60950-1 Approved
CH1
OUTPUTNUMBER