http://www.tracopower.com Page 1 of 4
Features
Wide 2:1 input range
High efficiency up to 88%
Extended operating temperature range
–40°C to +85°C
Indefinite short circuit protection
I/O isolation 1500 VDC
Input filter to meet EN 55022, Class A and
FCC, level A without external components
Industry standard footprint
Shielded metal case with insulated
baseplate
3-year product warranty
DC/DC Converters
TEN 15 Series, 15 Watt
The TEN 15 series is a family of high performance 15W DC/DC converters in a
compact 2” x 1” low profile package with industry standard footprint. A high effici-
ency allows a wide operating temperature range of –40°C to +85°C. A built-in EMI
filter is built in to meet EN 55022, class A without any external components.
Further standard features include over voltage protection and short-circuit protec-
tion. Typical applications for these converters are battery operated equipment, in-
strumentation, distributed power architectures in communication and industrial elec-
tronics, everywhere where isolated, tightly regulated voltages are required.
Order code Input voltage range Output voltage Output current max. Efficiency typ.
TEN 15-1210 3.3 VDC 4’000 mA 79 %
TEN 15-1211 5 VDC 3‘000 mA 82 %
TEN 15-1212 9 – 18 VDC 12 VDC 1’250 mA 86 %
TEN 15-1213 (12 VDC nominal) 15 VDC 1‘000 mA 86 %
TEN 15-1221 ±5 VDC ±1500 mA 83 %
TEN 15-1222 ±12 VDC ±625 mA 86 %
TEN 15-1223 ±15 VDC ±500 mA 84 %
TEN 15-2410 3.3 VDC 4’000 mA 80 %
TEN 15-2411 5 VDC 3‘000 mA 84 %
TEN 15-2412 18 – 36 VDC 12 VDC 1‘250 mA 85 %
TEN 15-2413 (24 VDC nominal) 15 VDC 1‘000 mA 85 %
TEN 15-2421 ±5 VDC ±1’500 mA 84 %
TEN 15-2422 ±12 VDC ±625 mA 86 %
TEN 15-2423 ±15 VDC ±500 mA 86 %
TEN 15-4810 3.3 VDC 4‘000 mA 81 %
TEN 15-4811 5 VDC 3‘000 mA 83 %
TEN 15-4812 36 – 75 VDC 12 VDC 1‘250 mA 87 %
TEN 15-4813 (48 VDC nomial) 15 VDC 1‘000 mA 86 %
TEN 15-4821 ±5 VDC ±1‘500 mA 85 %
TEN 15-4822 ±12 VDC ±625 mA 88 %
TEN 15-4823 ±15 VDC ±500 mA 87 %
Models
not recommended for new design in
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current at no load 12 Vin models: 30 mA typ.
24 Vin models: 20 mA typ.
48 Vin models: 15 mA typ.
Input current at full load 12 Vin; 3.3 VDC models: 1470 mA typ.
12 Vin; other models: 1550 mA typ.
24 Vin; 3.3 VDC models: 730 mA typ.
24 Vin; other models: 780 mA typ.
48 Vin; 3.3 VDC models: 360 mA typ.
48 Vin; other models: 380 mA typ.
Surge voltage 12 Vin models: 36 V max.
(100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 2 % – 100 % single output models: 0.5 % max.
dual output models: 1 % max. (balanced load)
5 % max. (load cross variation 25 % / 100 %)
Minimum load 2 % of rated max. output current.
(Operation at lower load is safe but major
deviations to specifyed data may occur)
Ripple and noise (20 MHz Bandwidth) single output models: 50 mVpk-pk max.
dual output models: 75 mVpk-pk max.
Temperature coefficient ±0.02 %/K
Start up time (nominal Vin and constant resistive load) 20 ms typ.
Transient response (25 % load step change) 250 µs typ.
Short circuit protection continiuous (automatic recovery)
Over load protection 150 % of Iout max typ. foldback
Over voltage protection 3.3 VDC models: 3.9 V
5.0 VDC models: 6.2 V
12 VDC models: 15 V
15 VDC models: 18 V
Capacitive load 3.3 VDC models: 10‘200 µF max.
5 VDC models: 7‘050 µF max.
12 VDC models: 1‘035 µF max.
15 VDC models: 750 µF max.
±5 VDC models: ±1‘020 µF max.
±12 VDC models: ±495 µF max.
±15 VDC models: ±165 µF max.
DC/DC Converters
TEN 15 Series 15 Watt
http://www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications
Temperature ranges Operating – 40°C to +8C
– Casing temperature +100°C max.
– Storage –55°C to +105°C
Derating 3.3 / 5.0 VDC models: 2.5 %/K above 60°C
other models: 3.3 %/K above 70°C
Thermal impedance – Natural convection 12°C/W
– Natural convection with heatsink 10°C/W
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >2.3 Mio h
Isolation Test Voltage (Input/Output, 60s) 1‘600 VDC
Insulation System Functional
Isolation Capacitance (Input/Output) 300 pF max.
Isolation Resistance (Input/Output) >1 G Ohm
Switching frequency single output models: 500 kHz typ. (pulse width modulation)
dual output models: 300 kHz typ. (pulse width modulation)
EMC immunity – Electrostatic discharge ESD EN 61000-4-2 8 kV / 6 kV, criteria B
– RF field susceptibility EN 61000-4-3 10 V/m, criteria A
– Electrical fast transient / burst immunity input EN 61000-4-4 ±2 kV, criteria B
– Surge immunity EN 61000-4-5 ±1 kV, criteria B
– Immunity to conducted RF disturbances EN 61000-4-6 10 Vrms, criteria A
Vibration acc. MIL-STD-810F
Thermal shock acc. MIL-STD-810F
Safety standards UL 60950-1, EN 60950-1, IEC 60950-1
Safety approvals – UL/cUL www.ul.com -> certifications -> File e188913
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Physical Specifications
Casing material copper, nickel plated
Baseplate material non conductive FR4
Potting material epoxy (UL 94V-0 rated)
Weight 27 g ( 09.5oz)
Soldering temperature max. +265°C / 10 sec.
DC/DC Converters
TEN 15 Series 15 Watt
Supporting documents : www.tracopower.com/overview/ten15
Page 4 of 4
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
DC/DC Converters
TEN 15 Series 15 Watt
Outline Dimensions
Pin Single Dual
1+Vin (Vcc) +Vin (Vcc)
2–Vin (GND) –Vin (GND)
3+Vout +Vout
4No pin Common
5–Vout –Vout
Pin-Out
Rev. July 11, 2018
Dimensions in [mm], () = Inch
Pin diameter: 1.0 ±0.05 (0.02 ±0.002)
Pin pitch tolerances: ±0.25 (±0.01)
Casing tolerances: ±0.5 (±0.02)
5.08
10.16
25.4
10.2
6.0
50.8
15.2 20.32
Insulated baseplate
(2.0)
(0.8)
(0.6)
(0.2)
(0.4)
(0.4)
(1.0)
2.5
(0.1)
(0.4)
(0.24)
Bottom View
14
3
2
5
10.16
10.2
(0.4)
Note:
The product label on converter has to be re-
moved before mounting the heat-sink.
For volume orders converters will be supplied
with heat-sinks already mounted. Please con-
tact factory for quotation.
Separate heat-sinks are only available for
prototypes and small quantity orders.
Order code: TEN-HS1
(cont.: heat-sink, thermal pad, 2 clamps)
Material: Aluminum
Finish: Anodic treatment (black)
Weight: 17g (0.60oz) without converter
Thermal impedance after assembling: 10 K/W
56.0 (2.2) max.
14.5 (0.57)
16.8 (0.66)
max.
Converter
Heat-sink
Thermal pad
Clamp
Heat-Sink (Option)