D-30
1 of 4 Rev 07/18/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
D-FRAME SOLENOID
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power 13 VA Continuous, 37 VA Intermittent, 120 VA Pulse
8.5 Watts Continuous, 21 Watts Intermittent, 85 Watts Pulse
Coil Termination .187” quick connect terminals (standard)
Wire leads optional with tape wrapped coil
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrapped optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Class F Rating - 155ºC (311ºF) Max. (optional)
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
Mechanical Specications
Size 2.015” (L) x 1.000” (W) x 1.218” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.4375”
Plunger Guide Material Plastic
Mounting 2X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.06 oz., Total - 7 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
UL File No. E57982 For Continuous Duty
UL File No. E74443 For Insulation Systems
S105, S130, S130D, S130D1, S155D
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
All dimensions in Inches
D-30
2 of 4 Rev 07/18/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
Dimensional View
Units: Inches [mm]
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
D-30
3 of 4 Rev 07/18/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
AC Continuous Duty - 13 VA DC Continuous Duty - 8.5 Watts
DC Intermittent Duty - 21 Watts
DC Pulse Duty - 85 Watts
AC Intermittent Duty - 37 VA
AC Pulse Duty- 120 VA
Force Curves
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes
minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”.
NOTE: Approx 36 sq. in. Heat Sink Required
D-30
4 of 4 Rev 07/18/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
Parts No. Voltage Duty Cycle Power Resistance
(Ohms) Operation Typical Force (oz). 100% Voltage, 77°, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
53748-80 6 VAC
Continuous 13 VA
0.41
Pull 65 16.5 13 11 0
53748-81 12 VAC 1.65
53748-82 24 VAC 6.71
53748-84 120 VAC 172
53748-85 240 VAC 700
53748-87 12 VAC
Intermittent 37 VA
0.871
Pull 108 29 21 17 0
53748-88 24 VAC 3.78
53748-90 120 VAC 86.2
53748-91 240 VAC 353
53748-93 12 VAC
Pulse 120 VA
0.43
Pull 176 55 40 33 0
53748-94 24 VAC 1.73
53748-96 120 VAC 45.5
53748-97 240 VAC 182
53749-80 6 VDC
Continuous 8.5
Watts
4.27
Pull 110 28 15 6 0
53749-81* 12 VDC 17.7
53749-82* 24 VDC 69.8
53749-84 110 VDC 1470
53749-86 6 VDC
Intermittent 21
Watts
1.65
Pull 133 58 40 16 0
53749-87* 12 VDC 6.71
53749-88* 24 VDC 26.8
53749-90 110 VDC 538
53749-92 6 VDC
Pulse 85
Watts
0.41
Pull 185 115 97 55 23
53749-93 12 VDC 1.65
53749-94 24 VDC 6.71
53749-96 110 VDC 148
Standard Part Numbers
(*) Normally Stocked
Non stocked items require a minimum order