Components 2000176 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS
Adding Preset Counters
for Front Panel Mounting
Preset value continuously visible
Manual or electric reset
3 or 5-digit indication
Various front panel sizes available
TECHNICAL DATA Display 3 or 5-digit indication of count and preset value,
depending on version
Digit height 4 mm
Supply voltage Vop see ordering code table, tolerance ± 10 %
230 VAC + 6–10 %
Power consumption counter: DC version 2.5 W, AC version 2.75 VA
reset solenoid: DC version 12 W, AC version 16 VA
Residual ripple 48 %
Operating temperature – 10 … + 50 °C
Storage temperature – 40 … + 85 °C
Electrical connection AMP connector, 0.8 x 2.8 mm
Mounting screw or clamping spring attachment, see "Order
information"
Mounting position roller axis horizontal
Protection class front IP 40; connections IP 00; for higher degree of
(EN 60529) protection we recommend a protective case with clear
cover (see "Accessories")
General design DIN EN 61010-1
Protection according to class II
Contamination level 2
Over voltage category II
Duty cycle at 25 °C Counter 100 %, reset solenoid: DC version
20 %, max. 2 minutes, AC versions 10 %, max. 1 minute
at 50 °C Counter 50 %, max. 10 minutes
Maintenance-free operation Counter: 2 x 108, reset solenoid 1.5 x 106pulses
Approvals UL: E 41 784-11
Count input adding
Min. pulse length DC version 20 ms, AC version 50 ms
Max. counting frequency DC version 25 Hz, AC version 10 Hz
Pulse duty factor 1:1
Reset – manual with button
external by electrical signal (versions with reset solenoid
only), min. pulse length 200 ms (max. see duty cycle);
Reset frequency DC version max. 1 per 2 s
Pulse duty factor DC version 1:5, AC version 1:10
Signal output
Signal duration from when preset has been reached until reset
Contact type changeover contact, floating
Switching voltage max. 220 VAC
Switching current max. 20 VA/1 A, non-inductive
Type 886/887
177Components 2000 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS
Technical data
3 digits 5 digits
Voltage button reset el. reset button reset el. reset
24 VDC 0 887 264 0 887 214 0 886 264 0 886 214
230 VAC 0 887 290 0 887 240 0 886 290 0 886 240
3 digits 5 digits
Voltage button reset el. reset button reset el. reset
24 VDC 0 887 464 0 887 414 0 886 464 0 886 414
230 VAC 0 886 490 0 886 440
Inquire for other voltages
For key reset add ordering code + SR, e.g. 0 887 264 SR
ORDER INFORMATION
Counters for screw attachment
Front panel 60 mm x 75 mm
COUNTERS FOR SPRING
ATTACHMENT
Front panel 55 mm x 53 mm
CONNECTION DIAGRAM
DIMENSIONS
Front panel 60 mm x 75 mm
Front panel 55 mm x 53 mm
Type 886/887