CSM_D4E-_N_DS_E_6_1
1
Small Sealed Switch
D4E-@N
Slim and Compact Switch with Better
Seal and Ensuring Longer Service
Life than D4E
Flat springs with an improved lever ratio of the built-in
switch ensure smooth snap action and long life expectancy.
Protection cover protects the built-in switch from dust and oil.
Plunger incorporates a tough seal cap that lasts for a long time.
One touch connector eliminates need for tedious wiring
operations and reduces downtime for wiring and
maintenance (models with standard, easy-to-use screw
terminals are also available).
Minute load model with gold cladding is optimal for
electronic control.
Molded terminal types as well as molded terminal types
with operating indicator lamps are available for screw
terminal systems.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for Information on
approved models.)
No difference in mounting pitch and characteristics
between D4E-@N and D4E models.
Be sure to read Safety Precautions on page 9 to 10 and
Safety Precautions for All Limit Switches.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
D4E-@@@@@N
(1)(2) (3) (4)
(1) Rated Current
1: 5 A at 125 VAC
(1 A at 125 VAC/30 VDC for model with a
connector)
2: 0.1 A at 125 VAC
(0.1 A at 125 VAC/30 VDC for model with a
connector)
(2) Actuator
A: Roller plunger
B: Crossroller plunger
C: Plunger
D: Sealed roller plunger
E: Sealed crossroller plunger
F: Sealed plunger
G: Roller lever
H: One-way action roller lever
(3) Terminals
00: AC connector
10: DC connector
20: Screw terminals without a cable
21: Screw terminals with a cable (right-hand)
22: Screw terminals with a cable (left-hand)
23: Molded terminals with a cable (right-hand)
24: Molded terminals with a cable (left-hand)
(Cable is S-FLEX VCTF 3 m)
Note: The terminal specifications in model numbers are
not the same for D4E-N and D4E Switches.
Comparison of New and Old Molded
Terminal Models
Model
Location of
lead outlet
D4E-N D4E
Right-hand
D4E-
@@
23N
D4E-@@21
Left-hand
D4E-
@@
24N
D4E-@@23
(4) Operation Indicator
None: Without operation indicator
L: Neon lamp (250 VAC)
L2: LED (24 VDC)
Note: Only the molded terminal models can be
equipped with an operation indicators.
2
D4E-@N
Ordering Information
Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector or 1 for DC connector.
2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed.
3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to page 8.
Plug
For models with connectors, select one of the specified Cables with Connectors (sockets) from the following table.
Specifications
Approved Standards
Ratings
Type One-touch connector type Screw terminal type
General-purpose
Micro load
General-purpose
without cable
Micro load
without cable
General-purpose
with cable
Micro load with
cable
Actuator Model Model Model Model Model Model
Roller plunger D4E-1A@0N D4E-2A10N D4E-1A20N D4E-2A20N D4E-1A21N D4E-2A21N
Crossroller
plunger D4E-1B@0N D4E-2B10N D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N
Plunger D4E-1C@0N D4E-2C@0N D4E-1C20N D4E-2C20N D4E-1C21N D4E-2C21N
Sealed roller
plunger D4E-1D@0N D4E-2D10N D4E-1D20N D4E-2D20N D4E-1D21N D4E-2D21N
Sealed crossroller
plunger D4E-1E@0N --- D4E-1E20N D4E-2E20N D4E-1E21N D4E-2E21N
Sealed plunger D4E-1F@0N D4E-2F10N D4E-1F20N D4E-2F20N D4E-1F21N D4E-2F21N
Roller lever D4E-1G@0N D4E-2G10N D4E-1G20N D4E-2G20N D4E-1G21N D4E-2G21N
One-way action
roller lever D4E-1H00N --- D4E-1H20N D4E-2H20N D4E-1H21N ---
Applicable limit
switches
Current
Type Type No. of
conductors Cable length Model
D4E-@@00N AC Straight
4
2 m XS2F-A421-D90-F
5 m XS2F-A421-G90-F
D4E-@@10N DC 2 m XS2F-D421-D80-F
5 m XS2F-D421-G80-F
Agency Standard File No. Approved models
UL UL508 E76675 D4E-@@20N Switches only except for Indicator-equipped Switches
CSA CSA C22.2 No. 14 LR45746 D4E-@@20N Switches only except for Indicator-equipped Switches
TÜV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on approved models.
CCC (CQC) GB14048.5 2003010305086795 Ask your OMRON representative for information on approved models.
Rated
voltage
Standard load Micro load
Non-inductive load (A) Inductive load (A)
Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
---
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25
---
---
---
---
---
1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03
---
---
---
---
---
0.1
0.1
0.1
---
---
Minimum
applicable
load
Standard load Micro load
160 mA at 5
VDC 1 mA at 5 VDC
Inrush
current
NC 10 A max.
NO 10 A max.
Note: 1. The above current ratings are for a
standard current and the values in
parentheses are for models with a
connector.
2. Inductive loads have a power factor of 0.4
min. (AC) and a time constant of 7 ms
max. (DC).
3. Lamp load has an inrush current of 10
times the steady-state current.
4. Motor load has an inrush current of 6
times the steady-state current.
3
D4E-@N
Approved Standard Ratings
UL/CSA
A300 TÜV (EN60947-5-1), CCC (GB14048.5)
Structure and Nomenclature
Voltage Carry
current Current (A) Volt-amperes (VA)
Make Break Make Break
120 V
240 V 10 A 60 A
30 A 6 A
3 A 7,200 720
Note: 1. @:Actuat or variation of item II
2. AC-14 0.5 A/125 VAC means as follows:
3. Appl icable category: AC-14
Rated operating current (Ie): 0.5 A
Rated operating voltage (Ue): 125 VAC
Model Applicable category
and ratings
Thermal current
(Ithe)
Indicator
III III IV
1
1
1
1
1
1
1
2
2
2
2
2
2
2
@
@
@
@
@
@
@
@
@
@
@
@
@
@
00
10
20, 21, 22
23, 24
23, 24
23, 24
23, 24
00
10
20, 21, 22
23, 24
23, 24
23, 24
23, 24
L
L1
L2
L3
L
L1
L2
L3
AC-14 0.5 A/125 VAC
DC-12 0. 5 A/30 VDC
AC-15 2A/250 VAC
DC-12 2A /4 8 VD C
AC-15 2A/250 VAC
DC-12 2A /1 2 VD C
DC-12 2A /2 4 VD C
DC-12 2A /4 8 VD C
AC-14 0.1A/125 VAC
DC-12 0. 1A/30 VDC
AC-14 0.1A/125 VAC
DC-12 0. 1A/48 VDC
AC-14 0.1A/125 VAC
DC-12 0. 1A/12 VDC
DC-12 0. 1A/24 VDC
DC-12 0. 1A/48 VDC
5 A
5 A
5 A
5 A
5 A
5 A
5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
---
---
---
Neon lamp
LED
LED
LED
---
---
---
Neon lamp
LED
LED
LED
D4E-1
G
23 L N
I II III IV
C
haracter
i
st
i
cs
Degree of protection IP67
Durability *
Mechanical 10,000,000 operations min.
Electrical
500,000 operations min.
(5 A at 250 VAC, resistive load)
5,000,000 operations min.
(10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value for the built-in swit ch when
tested alone)
Dielectric
strength
Between terminals of
same polarity 1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
current-carrying metal par t 1,500 VA C , 50 /60 Hz for 1 min/Uimp at 2. 5 kV
(EN60947-5-1)
Rated insulation voltage (Ui) 250V
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, I EC60269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional en c losed the rma l current (I the)5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature 10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 86 g (in case of roller plunger)
Eng
i
neer
i
ng Data
General-purpose Models
Electrical Durability (cosφ=1)
Operating temperature: +5
°
C to +30
°
C
Operating humidity: 40% to 70%RH.
3
11032 45678910
Switching current (A)
Durability (×104 operations)
Operating frequency: 30 operations/min
cosφ= 1
250 V A C
10
7
5
30
100
70
50
300
1,000
700
500
Note: 1. The above values are initial values.
2. The above ratings may vary depending on the
model. Contact your OMRON rep r esentative
for further details.
* Durability values are calculated at an operating
temperature of +5°C to +35°C, and an operating
humidity of 40% to 70%RH.
Movable Plunger
Rubber Cap (NBR)
· Rubber cap provides a tight seal and
ensures a long service life and
smooth reset at low temperatures.
Seal Packing (NBR)
Terminal Protection Cover
· D4E-@N has a wide wiring space of
10 mm horizontally. Screw Terminal
· Screw terminal incorporates a M3 screw with a toothed washer.
Bearing
·
The bearing load strength has been increased to prevent faulty
resetting of the bearing, which may occur when the roller is
pressed with excessive force.
Die-cast Case
· Zinc die-cast case is anti-corrosive and tough.
Wiring Ease
· Wired made easier using
(D4CC-type) plug-in connector.
Built-in Switch
·
Prevents the movable piece from being pushed in too far, and
thereby contributes to a longer service life.
·
Switch cover ensures high insulation between the terminals
and die-cast. Double insulation means that grounding is
unnecessary. Meets UL, CSA, and EN standards.
· Seal packing withstands a pressure of 186 kPa.
S
tructure
4
D4E-@N
Contact Form
Dimensions and Operating Characteristics (Unit: mm)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber fo r the lead wire outlet.
*2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm2, 7 mm in dia.) is provided.
NC
COM NO
(COM) 1 2 (NC)
4 (NO)
(COM) 1 4 (NO)
2 (NC)
Screw Terminal Type
Plunger Lever Connector Type
For AC For DC Positioning
piece *
Positioning
piece *
* The position of the positioning
piece is not always the same. If
using an L-shaped connector
causes problems in application,
use a straight connector.
(60) M12 × 1
Two, 2.1R
M14 × 1
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
OP
28.4 21.5
11
10 33
±0.15
6.53.5 (46)
8
4.5
4.7 holes
0.5
PT
holes
11 dia. × 4.7 stainless
sintered alloy roller
18
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
31.4
±
0.8 mm
Roller Plunger
D4E-1A00N
D4E-2A00N
D4E-1A10N
D4E-2A10N
(57)
16 dia.
M14 × 1
OP
28.4 21.5
11
10
3.5 (46)
8
4.5
4.7 holes
0.5
PT
11 dia. × 4.7 stainless
sintered alloy roller
18
6.5
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
33±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
31.4
±
0.8 mm
Roller Plunger
D4E-1A20N *1
D4E-2A20N *1
D4E-1A21N *2
D4E-2A21N *2
Two, 2.1R
(60) M12 × 1
M14 × 1
OP
28.4 21.5
11
10
3.5 (46)
8
4.5
4.7 holes
0.5
PT
11 dia. × 4.7 stainless
sintered alloy roller
18
6.5
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
33
±
0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
31.4
±
0.8 mm
Cross Roller Plunger
D4E-1B00N
D4E-1B10N
D4E-2B10N
M14 × 1
18
OP
28.4 21.5
11
10
3.5 (46)
8
4.5
4.7 holes
0.5
PT
11 dia. × 4.7 stainless
sintered alloy roller
(57)
16 dia.
6.5
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
33±0.15
holes
4.2+0.2
0 dia.
4.2+0.2
0 dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
31.4
±
0.8 mm
Cross Roller Plunger
D4E-1B20N *1
D4E-2B20N *1
D4E-1B21N *2
D4E-2B21N *2
5
D4E-@N
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lea d wire outlet.
*2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm2, 7 mm in dia.) is provided.
Two, 2.1R
(60) M12 × 1
M14 × 1
OP
28.4 21.5
11
10 6.53.5 (46)
8
4.5
4.7 holes
0.5
PT 7.8 dia. stainless
steel plunger
18
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
33±0.15
holes
4.2+0.2
0 dia.
4.2+0.2
0 dia.
Plunger
D4E-1C00N
D4E-2C00N
D4E-1C10N
D4E-2C10N
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
25.4
±
0.8 mm
(57)
OP
28.4 21.5
11
10 6.53.5 (46)
8
4.5
4.7 holes
0.5
PT
16 dia.
18
M14 × 1
7.8 dia. stainless
steel plunger
Two, panel mounting nut
2.5 mm thickness, 17 mm
width across flats
33±
0.15
holes
4.2+0.2
0 dia.
4.2+0.2
0 dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
25.4
±
0.8 mm
Plunger
D4E-1C20N *1
D4E-2C20N *1
D4E-1C21N *2
D4E-2C21N *2
(60) M12 × 1
OP
28.4 21.5
10 6.53.5 (46)
4.5
4.7 holes
0.5
PT
18
11 dia. × 4.7 stainless
sintered alloy roller
Sealed rubber
33
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
41.3
±
0.8 mm
Sealed Roller Plunger
D4E-1D00N
D4E-1D10N
D4E-2D10N
OP
28.4 21.5
10 6.53.5 (46)
4.5
4.7 holes
0.5
PT
18
11 dia.
×
4.7 stainless
sintered alloy roller
Sealed rubber
(57)
16 dia.
holes
33
±0.15
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
41.3
±
0.8 mm
Sealed Roller Plunger
D4E-1D20N *1
D4E-2D20N *1
D4E-1D21N *2
D4E-2D21N *2
6
D4E-@N
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. A 5.8-dia. to 7.6-dia. cable can be applied to t he seal rubber for the lead wi re outlet.
*2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm2, 7 mm in dia.) is provided.
(60) M12
×
1
OP
28.4 21.5
10
3.5 (46)
4.5
4.7 holes
0.5
PT
18
11 dia.
×
4.7 stainless
sintered alloy roller
Sealed rubber
6.533
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
Sealed Cross Roller Plunger
D4E-1E00N
D4E-1E10N
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
41.3
±
0.8 mm
OP
28.4 21.5
10
3.5 (46)
4.5
4.7 holes
0.5
PT
11 dia. × 4.7 stainless
sintered alloy roller
18
(57)
Sealed rubber
6.5
33
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
41.3
±
0.8 mm
Sealed Cross Roller Plunger
D4E-1E20N *1
D4E-2E20N *1
D4E-1E21N *2
D4E-2E21N *2
Two, 2.1R
(60) M12 × 1
OP
28.4 21.5
10 6.53.5 (46)
4.5
4.7 holes
0.5
PT
18
7.8 dia. stainless
steel plunger
Sealed rubber
holes
33±0.15
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
30
±
0.8 mm
Sealed Plunger
D4E-1F00N
D4E-1F10N
D4E-2F10N
Two, 2.1R
OP
28.4 21.5
10 6.53.5 (46)
4.5
4.7 holes
0.5
PT
18
7.8 dia. stainless
steel plunger
Sealed rubber
(57)
33
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
Operating Position OP
30
±
0.8 mm
Sealed Plunger
D4E-1F20N *1
D4E-2F20N *1
D4E-1F21N *2
D4E-2F21N *2
7
D4E-@N
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lea d wire outlet.
*2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm2, 7 mm in dia.) is provided.
Two, 2.1R
(60) M12
×
1
15
28.4 21.5
19.4
6.53.5 (46)
12
4.7 holes
0.5
23R
OP
PT
9.5 dia.
×
4.0 stainless
sintered alloy roller
18
holes
33
±0.15
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
Operating Position OP
23.1
±
0.8 mm
Roller Lever
D4E-1G00N
D4E-1G10N
D4E-2G10N
15
28.4 21.5
19.4
6.53.5 (46)
12
4.7 holes
0.5
23R
OP
PT
9.5 dia.
×
4.0 stainless
sintered alloy roller
16 dia.
(57) 18
33
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Two, 2.1R
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
Operating Position OP
23.1
±
0.8 mm
Roller Lever
D4E-1G20N *1
D4E-2G20N *1
D4E-1G21N *2
D4E-2G21N *2
Two, 2.1R
(60) M12
×
1
15
28.4 21.5
19.4
28R
6.53.5 (46)
12
4.7 holes
0.5
OP
PT
9.5 dia.
×
4.0 stainless
sintered alloy roller
A
18
holes
33
±0.15
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Operating
direction
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
Operating Position OP
34.3
±
0.8 mm
One-way Action Roller Lever
D4E-1H00N
Two, 2.1R
15
28.4 21.5
19.4
28R
6.53.5 (46)
12
4.7 holes
0.5
OP
PT
9.5 dia.
×
4.0 stainless
sintered alloy roller
16 dia.
(57)
A
18
33
±0.15
holes
4.2
+0.2
0
dia.
4.2
+0.2
0
dia.
Operating
direction
( ) :Reference Value
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
Operating Position OP
34.3
±
0.8 mm
One-way Action Roller Lever
D4E-1H20N *1
D4E-2H20N *1
D4E-1H21N *2
8
D4E-@N
Molded Terminal Models
Operation of Indicator-equipped Models
The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and
inspection.
The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the
Switch wiring cannot be made.)
AC Operation
The operating voltage is 90 to 250 VAC.
There is no difference in operating characteristics between D4E-
@N AC Models and corresponding D4E-@N Standard Models.
There is no difference in dimensions between D4E-@N AC Models
and D4E-@N Standard Models.
Example:
Add “L” at the frond of “N”, which is suffix of a part number.
Basic type: D4E-1A23N
When placing your order for the molded terminal model with an neon
lamp operation indicator, specify the model number as D4E-1A23LN.
Internal Circuit
DC Operation
LED indicator is provided.
As a rectifier stack is incorporated, into the unit and no directionality
exists for connection of + and
, this type can also be operated on AC.
Voltage ratings of LED indicators are as shown in the table below.
Example:
Add “L2” at the frond of “N”, which is suffix of a part number.
Basic Model: The model number of the D4E-1A23N with a built-in
24-V LED indicator is D4E-1A23L2N.
Internal Circuit
The molded-terminal model is available with
right-hand and left-hand leads and is
recommended for use where the Switch is
exposed to dust, oil or moisture. It can be used
like a screw-terminal model (with a cable), and
the dimensions and operating characteristics
are the same as for standard models.
(2) (1)
Suffix by Location of Lead Outlet
Example:
Standard type: D4E-1A20N
Location of lead output:
Right-hand D4E-1A23N
Lead Supplies
Location of
lead outlet
Suffix for pre-wired terminal
COM, NC, NO
Right-hand D4E-@@23N (1)
Left-hand D4E-@@24N (2)
Specifications
Nominal
cross-sectional
area
(mm2)
External
diameter Terminal
connections Cable length
(m)
Leads
V.C.T.F. S-FLEX
(vinyl cabtire coat)
0.75 3 conductors Black: COM
White: NO
Red: NC 3 (Standard)
7 mm dia.
Neon lamp Terminal protection cover
(transparent)
Power supply
Built-in switch
Load
Neon lamp R = 240 kΩ
Type Voltage rating
(V) Leakage
current (mA)
Internal
resistance
(kΩ)
L2 24 Approx. 1.2 18
Power supply
Built-in switch
Resistor
Load
LED
9
D4E-@N
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Do not solder the screw terminals.
Sealing materials may deteriorate when used outdoors or when
exposed to cutting oil, solvents, or chemicals. Check this on actual
equipment and, if deterioration is foreseen, consult your OMRON
representative in advance.
If the one-touch connector is to be mounted onto the switch body,
lightly push up the fitting so that the switch body can then be
inserted into the clamp.
Be sure that the clamp is inserted to the full depth, because the
Switch will not function properly if one of the clamps is improperly
inserted.
If the clamp is properly inserted up to the full depth, it will not slide
out easily. Be sure to carefully confirm all the above items.
Be sure to connect a fuse with a breaking current 1.5 to 2 times the
rated current to the Limit Switch in series in order to protect the
Limit Switch from damage due to short-circuiting. When using the
Limit under the EN ratings, use a gI or gG 10-A fuse that conforms
to IEC60269.
Mounting
Secure the Switch with two M4 screws and washers. The tightening
torque applied to each terminal must be 1.18 to 1.37 N·m. Tighten
the screws to the specified torque. An excessive tightening torque
may damage the Switch and cause a malfunction.
When mounting the panel mount-type Switch with screws on a side
surface, remove the hexagonal nuts from the actuator.
When mounting the panel mount type on a panel, tighten the
hexagonal nuts of the actuator to a torque less than 7.85 N·m.
Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
precision of the Limit Switch. Make sure that the shape of the cam
is smooth enough.
Check that OT has a sufficient margin. The actual OT should be
rated OT × 0.7 to 1.
Do not change the operating position by remodeling the actuator.
Wiring
When wiring screw terminals, M3-size round solderless terminals with
an insulation tube is recommended. The conductor size should be
0.75 mm2 and cable diameter should be 7 mm.
Precautions for Correct Use
Not Suitable Suitable
(1) Insert the switch
body
(2) Lightly push up the filling on the
left and right side alternately.
Switch body
Clamp fitting
Confirm
visually
33±0.15
Two, 4.3 dia. or M4 hol
e
Mounting Holes
14.5±0.2 dia.
Mounting Hole
L
lF
B
D dia.
dz dia.
dz dia.: 3.2
D dia.: 1.9
B: 5.2
L: 16.4
F: 5.8
l: 8.0 (mm)
Round solderless terminals
Wiring Method
Round solderless terminal
10
D4E-@N
Tightening Torq ue
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No. Type Appropriate
tightening torque
(1) Terminal screw (M3) 0.24 to 0.44 N·m
(2) Switch mounting screw (M4) 1.18 to 1.37 N·m
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/