SWS300/600 Series Single Output General Purpose Power Supplies Features Low Cost Active Power Factor Correction Universal Input (85 - 265VAC) Input Transient Protected IEC61000-4 SEMI F47 Certified (208VAC Input) Global safety Approvals Level B EMI Key Market Segments & Applications Specifications Model Input Voltage range (1) Inrush Current (115 / 230VAC) Power Factor Input Current (100/200VAC) Temperature Coefficient Overcurrent Protection Overvoltage Protection Overtemperature Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Parallel Connection Remote On/Off Power Fail Signal LED Indicator Operating Temperature Storage Temperature Humidity (non-condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Immunity Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Weight (Typ) Size (WxHxD) Warranty A A V ms mA C C g in yrs SWS300 SWS600 85 - 265VAC (47 - 63Hz) or 120 - 370VDC* 20 / 40 at 25C, cold start Meets EN61000-3-2 3.6 / 1.8A 7.2 / 3.6A <0.02%/C >105%, Constant current style 3.3V: 4.1-5.3V, 5V: 6.25-7.5V, 12V: 13.8-16.8V 15V: 19.3-24.2V, 24V: 30-34.8V, 36V: 41.4-50.4V, 48V: 60-69.6V Yes, cycle AC to reset 20ms at 115/230VAC SWS300: 0.75mA , SWS600: 1.5mA None Yes None Yes None Yes, >4.5V to shutdown None Yes, open collector output Green LED = On -10 to +65C (See table for derating - model specific) -30 to +85C 30 - 90% RH operating, 10 - 95%RH non operating Internal fan I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to CNT 100VAC for 1 min >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (sweep for 1 min)19.6m/s2 constant X, Y, Z 1 hour each plane) EN61000-4-2, -3, -4, -5, -6, -8, -11 UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark, SEMI F47 (208VAC) EN55011 / EN55022-B, FCC Class B MC1206 MC1210 950 2000 2.05 x 4.01 x 7.8" 3.62 x 4.72 x 7.48" Two Years Notes:(1) Derate linearly to 80% load from 115VAC to 85VAC input (derate to 90% load for SWS600-5, no derating SWS300, 600-3) *Safety certified for AC input only 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 99 Disclaimer: us.tdk-lambda.com/lp/legal.htm SWS300/600 Series Model Selector Derating Max Load Line Ripple Adjust Curr. Reg Reg Noise Eff.(3) Model Voltage Range (A) (mV) (mV) (mV) (typ)% SWS300-3 3.3V 2.97-3.96V 55 40 20 120 67/70 SWS300-5 5V 4.5-6V 55 40 20 120 75/78 SWS300-12 12V 9.6-13.2V 26 96 48 120 77/80 SWS300-15 15V 13.2-18.6V 21 120 48 120 79/83 SWS300-24 24V 20-28.8V 13 120 48 150 80/84 SWS300-36 36V 28.8-40V 8.7 180 72 200 82/85 SWS300-48 48V 40-57.6V 6.7 240 96 240 82/85 SWS600-3 3.3V 2.97-3.96V 100 (2) 40 20 100 69/71 SWS600-5 5V 4.5-6V 100 (2) 40 20 100 74/77 SWS600-12 12V 9.6-13.2V 50 96 48 120 78/81 SWS600-15 15V 13.2-18.6V 40 120 48 120 80/83 SWS600-24 24V 20-28.8V 25 120 48 150 81/84 SWS600-36 36V 28.8-40V 16.7 180 72 200 81/85 SWS600-48 48V 40-57.6V 12.5 240 96 240 82/85 Notes: (2) Peak rating of 120A for 10s Model 50C 55C 60C 65C SWS300 100% 91.6% 83.3% 50% SWS600 100% 85% 70% 55% Additional derating required when operating SWS600 with side ventilation holes blocked - see installation manual. Options Suffix /CO2 Descriptor Double sided conformal coating Other Industrial Products HWS SWS ZWS 15-1500W Single Output, High Reliability 50-150W Single Output 5-240W PCB style Single Output (3) 115/230VAC Outline Drawing - 3.5 SWS300 Outline Drawing 34 .5 8.2 - - 1 2 3 16.5 2 A F -S 10 .A A 21 11 .0 1 21 A 20 apped on both sides 0.5 1 1 0 50/60Hz 0.5 0.5 10 25 AIR F 5 A N 0 L 100 -V 25 -V 10 -V 21 +V 20 INPUT: 100-240VAC ~ 4.4A 55 A 0.5 +V 50 OUTPUT: 5 V 20 SWS300- 5 21 +V S S 150 0.5 apped at the bottom chassis apped on both sides A S 150 A 20 ole at the opposite chassis 15 A 120 8- 4 .5 A S BAR CODE MADE IN CHINA V ADJ H For Additional Information, please visit us.tdk-lambda.com/lp/products/sws-series.htm N o t Rec o m en d e d Fo r Ne w D e s i gns 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 100 Revision B1: Sept. 2014