109www.conesys.com sales@aero-electric.com
26482 S 2
– –
MIL-DTL-26482
Performance Specications
Series 2
Performance Specications
Operating Temperature Range
Classes A, L and S*: -55°C to +200°C (-67°F to +392°F)
Classes W and ZC*: -55°C to +175°C (-67°F to +347°F)
Material and Finish Data (Class)
A – aluminum shell, black anodized nish
L – aluminum shell, electroless nickel nish
W – aluminum shell, olive drab cadmium over nickel base
S* – stainless steel shell, passivated
BN* – aluminum shell, black nickel nish (Aero P/N only)
Corrosion Resistance
Classes A, S*, W and BN* withstand 500-hour salt spray.
Class L withstands 48-hour salt spray.
Environmental Seal
Wired, mated connectors with specied accessories at-
tached, shall meet the altitude-immersion test specied in
MIL-DTL-26482 Series 2.
Fluid Resistance
Connectors resist specied immersions in MIL-PRF-7808
(lubricating oil), MIL-PRF-23699 (lubricating oil),
MIL-PRF-5606 (hydraulic uid), M2-V Chevron oil, Cool-
anol 25, ASTM D4814 (gasoline), SAE-AMS1424 Type I
(defrosting uid), MIL-DTL-5624 (JP-5), and solvents
specied in Method 215 of MIL-STD-202.
* Not on QPL, can be supplied to Aero-Electric P/N only.
Durability
Mated connectors withstand a minimum of 250 mating
cycles for RFI plug (MS3475) and 500 cycles for standard
plug (MS3476).
Shock and Vibration Requirements
Wired, mated connectors shall not be damaged, coupling
ring shall not loosen, and there shall be no interruption of
electrical continuity longer than one microsecond when
subjected to the following:
Shock
Mated connectors withstand a pulse of approximate half
sine wave of 300 G magnitude with duration of three
milliseconds applied in each direction of the three major axes.
Vibration
Mated connectors withstand the following vibration levels:
• Random vibration per MIL-STD-202, method 214, test
condition II, letter J.
Shielding Eectiveness
RFI attenuation at the specied frequency meets the require-
ments of MIL-DTL-26482 Series 2.
• RFI shielding eectiveness of mated connectors with
RFI backshells is measured in a triaxial radio frequency
leakage xture.
Shell-to-Shell Conductivity
• With RFI spring ngers, the maximum potential drop
shall not exceed 5 millivolts.
• Without spring ngers, the maximum potential drop
shall not exceed 200 millivolts.
Service
Rating
Suggested Operating Voltage** Test Voltage Test Voltage Test Voltage Test Voltage
(Sea Level) Sea Level 50,000 Ft. 70,000 Ft. 110,000 Ft.
AC (RMS) DC V RMS V RMS V RMS V RMS
I 600 850 1,500 500 375 200
II 1,000 1,275 2,300 750 500 200
Voltage Rating
** To be used by designer only as a guide.