SPECIFICATION
FileName:ADS-155-SPEC2010-10-18
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
1000ms,90ms/230VAC2000ms,90ms/115VACatfullload
24ms/230VAC20ms/115VACatfullload
88~264VAC124~370VDC
47~63Hz
77% 82% 82%
2.5A/115VAC1.5A/230VAC
COLDSTART 20A/115VAC40A/230VAC
<1mA /240VAC
105~135% ratedoutputpower
CH1:13.8~16.2V CH1:27.6~32.4V CH1:55.2~64.8V
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisreoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
202.3Khrsmin.MIL-HDBK-217F(25 )
199*110*50mm(L*W*H)
1Kg;16pcs/16Kg/0.95CUFT
POWERFACTOR (Typ.) PF>0.92
ADS-15512 ADS-15524 ADS-15548
12V
11.5A
0~12.5A
153W 154.2W 154.2W
150mVp-p
CH1:10.8~13.2V CH1:21.6~26.4V CH1:43.2~52.8V
0.5%0.5% 0.5%
0.5%
0.5% 0.5% 0.5%
1.0% 2.0% 2.0% 1.0% 1.0%
2.0% 3.0% 1.0% 3.0% 1.0% 5.0%
5V
CH2
24V
CH1
5V
CH2
48V
CH1
5V
CH2
3A 5.8A 3A 2.9A 3A
0~3A 0~6.5A 0~3A 0~3.2A 0~3A
100mVp-p 150mVp-p 100mVp-p 240mVp-p 100mVp-p
155WSingleOutputwith5V,3A DC-DCConverter
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC 67KHz, PWM 134KHz
2 years warranty
Features :
ADS-155 series
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
EMICONDUCTION&RADIATION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
CH1
OUTPUTNUMBER
http://store.iiic.cc/
MechanicalSpecification
DeratingCurve OutputDeratingVSInputVoltage(15512)
FileName:ADS-155-SPEC2010-10-18
CaseNo.906BUnit:mm
AMBIENTTEMPERATURE( )
LOAD(%)
LOAD(%)
INPUTVOLTAGE(V)60Hz
9088 100 120 140 160 180 200 220 240 260
100
90
80
70
60
50
40
-10 0 10 20 30 40 50 60 70
20
40
60
80
100
With21.6CFMmin.(10cm)
WithNOFAN
+12V
(HORIZONTAL)
BlockDiagram
PFCfosc:67KHz
PWMfosc:134KHz
PWM&PFC CIRCUIT
DETECTION
O.L.P.
EMIFILTER
RECTIFIERS CIRCUIT
POWER
SWITCHING FILTER
&
REGULATOR
RECTIFIERS
SWITCHING
+V
+5V
-V
I/P
FG
CONTROL
O.V.P.
&PFC
CONSTANT
CURRENT
LIMITING&
START
CIRCUIT
ACTIVE
TerminalPinNo. Assignment
PinNo. PinNo.
1
2
5
3
4
6,7
8
Assignment Assignment
NC
DCOUTPUT COM
DCOUTPUT +V
FG
AC/L
AC/N
+5V
20 159
199
6.5
20
3.5
25
3-M3
12
37
100
172
192
5-M3
97
3.5
190.5
24.5
16.5
3.5
50
6
110
8.2 9.5 12
7
8
6
5
4
3
2
1
6
5
155WSingleOutputwith5V,3A DC-DCConverter ADS-155 series
http://store.iiic.cc/