PERFORMANCE FEATURES
The ultraminiature RF100 and RF103 relays are
designed to provide improved RF signal repeatability
over the frequency range by balancing the aggregate
insertion loss elements of the relays’ design. Highly
suitable for use in attenuator and other RF circuits, the
RF 100 and RF103 feature:
• High repeatability.
• Broader bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case grounding.
• High isolation between control and signal paths.
• Highly resistant to ESD.
CONSTRUCTION FEATURES
The following unique construction features and
manufacturing techniques provide excellent resistance
to environmental extremes and overall high reliability.
• Uni-frame motor design provides high magnetic
efficiency and mechanical rigidity.
• Minimum mass components and welded construction
provide maximum resistance to shock and vibration.
• Dual weld projection provides increased design
robustness.
• Advanced cleaning techniques provide maximum
assurance of internal cleanliness.
• Gold plated precious metal alloy contacts ensure
reliable switching.
• Hermetically sealed .
Solderable leads.
TELEDYNE RELAYS
HIGH REPEATABILITY
CENTIGRID® RELAY
SERIES
DESIGNATION
RF100
RF103
RELAY TYPE
Repeatable, RF, Centigrid® relay
Sensitive, repeatable, RF, Centigrid® relay
INTERNAL CONSTRUCTION
SERIES
RF100
RF103
ULTRAMINIATURE
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
Vibration (General Note 1)
Shock (General Note 1)
Enclosure
Weight
-55 °C to +85 °C
Hermetically sealed
10 G to 500 Hz
30 G, 6 ms. half sine
RF100
RF103
0.09 oz. (2.55 g) max.
0.16 oz. (4.50 g) max.
UPPER STATIONARY
MOVING CONTACT
LOWER STATIONARY
UNIFRAME
ARMATURE
CONTACT
CONTACTS
DC TO RF
BROADBAND
NEW
TYPICAL RF CHARACTERISTICS (Notes 1, 2 and 3)
ISOLATION POLE TO POLE (NOTE 4)
RF Notes:
1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a registered
trademark of Rogers Corporation).
b. Relay header is in contact with but not soldered to ground plane or connected to ground via ground pin.
c
.
Test performed at room ambient temperature.
d. Terminals not tested were terminated with 50 ohm load.
e. Contact signal level: 20 dBm.
2. Data presented herein represents typical characteristics and is not intended for use as specification limits.
3. Data is per pole.
4. Data is the average from readings taken when the relay is de-energized and energized. Measurement points are from pins 1 and 3 to
pins 5 and 7 (de-energized) and pins 1 and 2 to pins 6 and 7 (energized).
5.Data is the average from readings taken when the relay is de-energized and energized. Measurement points are from pins 1, 3 to 2 and
pins 5,7 to 6 (de-energized) and pins 1,2 to 3 and pins 6,7 to 5 (energized).
SERIES RF100 and RF103
INSERTION LOSS AND VSWR CHARACTERISTICS RF100 and RF103 NORMALLY CLOSED CONTACTS
INSERTION LOSS AND VSWR CHARACTERISTICS RF100 and RF103 NORMALLY OPEN CONTACT
ISOLATION CHARACTERISTICS RF100 AND RF103 RELAYS
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
INSERTION LOSS
1.0 2.0 3.0
0.0
-0.2
-0.4
-0.6
-0.8
-1.0
1.2
-1.4
-1.6
-1.8
-2.0
FREQUENCY (GHz)
INSERTION LOSS (dB)
VSWR
VSWR
.0003 4.0 5.0 6.0
INSERTION LOSS
FREQUENCY (GHz)
INSERTION LOSS (dB)
VSWR
VSWR
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
1.0 2.0 3.0
0.0
-0.2
-0.4
-0.6
-0.8
-1.0
1.2
-1.4
-1.6
-1.8
-2.0.0003 4.0 5.0 6.0
-10
-20
-30
-40
-50
-60
0
1.0 2.0 3.0.0003 FREQUENCY (GHz)
ISOLATION (dB)
4.0 5.0 6.0
-10
-20
-30
-40
-50
-60
0
1.0 2.0 3.0.0003 FREQUENCY (GHz)
ISOLATION (dB)
4.0 5.0 6.0
ISOLATION CONTACT TO CONTACT (NOTE 5)
TYPICAL RF INSERTION LOSS REPEATABILITY CHARACTERISTICS (Notes 1 and 2)
RF Insertion Loss Repeatability Notes
1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid 6002® with SMA connectors. (RT/duroid® is a registered
trademark of Rogers Corporation).
b. Relays header is connected to but not soldered to ground plane nor connected via ground pin.
c
.
Test performed at room ambient temperature.
d. Contact signal level: 20 dBm.
2. Data presented herein represents typical characteristics and is not intended to be used as specification limits.
3. Insertion loss repeatability measured over frequency range from .3 MHz to 4 GHz.
SERIES
RF100
an
d
RF103
100
90
80
70
60
50
40
30
20
10
00.02 0.14 0.04 0.06 0.08 0.1 0.12 0.16 0.18 0.2
REPEATABILITY (dB)
REPEATABILITY CHARACTERISTICS RF100 RELAYS
% TOTAL NUMBER RECORDED TEST CYCLES
100
90
80
70
60
50
40
30
20
10
00.02 0.14 0.04 0.06 0.08 0.1 0.12 0.16 0.18 0.2
REPEATABILITY (dB)
% TOTAL NUMBER RECORDED TEST CYCLES
100
90
80
70
60
50
40
30
20
10
00.02 0.14 0.04 0.06 0.08 0.1 0.12 0.16 0.18 0.2
REPEATABILITY (dB)
% TOTAL NUMBER RECORDED TEST CYCLES
100
90
80
70
60
50
40
30
20
10
00.02 0.14 0.04 0.06 0.08 0.1 0.12 0.16 0.18 0.2
REPEATABILITY (dB)
% TOTAL NUMBER RECORDED TEST CYCLES
REPEATABILITY CHARACTERISTICS RF103 RELAYS
NORMALLY OPEN
NORMALLY OPEN
NORMALLY CLOSED
NORMALLY CLOSED
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)
DETAILED ELECTRICAL SPECIFICATIONS (@ 25°C)
GENERAL NOTES
1. Relays will exhibit no contact chatter in excess of 10 µs or transfer in excess of 1 µs.
Contact arrangement DPDT
Rated duty Continuous
Contact resistance .100 ohm max. initial (measured 1/8” from the header)
Contact load rating Low level: 10 to 50 µA, 10 to 50 mV
Contact life rating 10,000,000 cycles typical at low level
Coil operating power RF100: 450 mW typical @ nominal rated voltage
RF103: 200 mW typical @ nominal rated voltage
Operate time RF100 4.0 ms. max.
RF103 6.0 ms. max.
Release time RF100 3.0 ms. max.
RF103 3.0 ms. max.
Intercontact capacitance 0.4 pF typical
Insulation resistance 1,000 M min. (between mutually isolated terminals)
Dielectric strength 350 VRMS / 60 Hz @ atmospheric pressure
BASE PART NUMBERS RF100-5
RF103-5 RF100-12
RF103-12
Coil voltage, nominal, VDC 5.0 12.0
Coil resistance, ohms ± 20% RF100 50 390
RF103 100 800
Pick-up voltage max, VDC 3.6 9.0
• TERMINAL NUMBERING AND SCHEMATIC ARE AS VIEWED FROM THE TERMINALS.
• DIMENSIONS ARE IN INCHES (MILLIMETERS).
• SCHEMATIC AND EXTERNAL DIMENSIONS SHOWN WITHOUT GROUND PINS.
• TO ORDER THE CASE GROUND OPTION, AFTER THE SERIES DESIGNATOR, ADD “Y” TO
THE PART NUMBER FOR TAB POSITION OR “Z” TO THE PART NUMBER FOR CENTER
POSITION . EXAMPLE: RF1##Y-COIL VOLTAGE
SERIES
RF100
an
d
RF103
OUTLINE DIMENSIONS
EXTERNAL DIMENSIONS
TERMINAL NUMBERING SCHEMATIC
TELEDYNE RELAYS
©1998
12525 Daphne Ave.
Hawthorne, CA 90250
(213) 777-0077
http://www.teledynerelays.com.
.031 (.79)
REF.
.035 (.89)
REF.
1
2
3
4
5
6
78H DIMENSION
RF100
RF103
.290
(7.37)
.395
(10.03)
MAX.
.017 +.002
-.001
()
.43 +.05
-.03
.335
(8.51)
SQ. MAX.
.375
(9.53)
SQ. MAX.
H
.75 (19.05) MIN.
0.100 ± 0.010