The VSX60 series are dual output converters
having two input ranges, either 18-36V or
36-75V. The units' dual asymmetric output
voltages are 5V and 3.3V. The converter
features an industry-standard quarter-brick
size (2.3" x 1.5" x 0.5") coupled with 90%
effi ciency.
These converters utilize Vx high density
technology. This technology has been
featured in our highly effi cient VKP and VKA
series now successfully in use worldwide.
The very high effi ciency minimizes the
requirement for heat-sinking and the
low output ripple minimizes the need for
additional fi ltering. For maximum fl exibility,
power can be traded between outputs as
required. The VSX60 series feature virtually
all of the options required by design
engineers but not at the competition’s
typical additional price for each option. This
multitude of features are standard on the
VSX60 series.
Absolute Maximum Rating
Parameter Symbol Min Max Unit
Input Voltage:
VSX60LD35C Vi 100 Vdc
VSX60MD35C Vi 75 Vdc
I/O Isolation Voltage 1500 Vdc
I/P to case 1500 Vdc
O/P to case 200 Vdc
Operating Case Temperature T –40 100 °C
VSX60
VSX60-U
ISO9001
CERTIFIED
PRODUCT OVERVIEW
APPLICATIONS
Distributed Power Architectures
Workstations
EDP Equipment
Telecommunications
OPTIONS
Choice of Remote On/Off logic
Confi guration
Heatsink Available for
Extended Operation
ADDITIONAL INFORMATION
See Application Note DCAN-40
at www.murata-ps.com
FEATURES
RoHS Compliant
2.5V & 3.3V Dual Output
2.3" x 1.5" x 0.5"
90% Effi ciency
Low Output Noise
Input Filtering
Remote On/Off, Input Side
Output Voltage Trim, +/-10%
Fixed Frequency Operation
–40C° to +100C° Baseplate Temp.
Output Current Limit, Self-Start
1,500 Vdc Isolation, Input to Output
UL/CUL 1950, EN60 950
36 to 75 Vdc Input Models
Continuous Short Circuit Protection
Non-latching Protection:
Input Undervoltage
Input Overvoltage
Output Overvoltage
Overtemperature
Output Voltage Tracking at
Turn-on and Turn-off
No Minimum Load Current
VSX60XD35C
60 Watt Dual Output Quarter Brick DC/DC Converter
TDC_VSX60XD35C.B02 Page 1 of 4
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000www.murata-ps.com
www.murata-ps.com
For full details go to
www.murata-ps.com/rohs
 
PARAMETER SYMBOL MIN TYP MAX UNITS
Output voltage (Note 1)
Over all conditions of I/P voltage,
load and temperature)
3.3 Vout (V2) 3.3 Vo 2.375 _ 2.555 Vdc
5.0 Vout (V1) 5.0 Vo 3.225 _ 3.450 Vdc
Output Voltage Setpoint
(Vi=48, Io2=9A, Io3=6A, Tc=25°C)
3.3 (V2) 3.3 Vo,set 2.450 2.510 Vdc
5.0 (V1) 5.0 Vo,set 3.310 3.390 Vdc
Output Ripple and Noise Voltage
(peak-to-peak, 100 MHz BW)
3.3 (V2) _
_
_ 60 mv p-p
5.0 (V1) _
_
_80 mv p-p
Output Current
(Total module O/P power should
not exceed 60 Watts)
3.3 (V2) Io2
_
_ 15 A
5.0 (V1) Io1
_
_ 12 A
Output Current Limit Inception
(Vo=95% of Vo nom)
3.3 (V2) Io2cli 19.0 21.0 23.0 A
5.0 (V1) Io1cli 12.5 13.5 15.0 A
Output Short Ckt Current 16 19 22 A
(Max impedance across short circuit = 65m:)
3.3 Vo 16 19 22 A
5.0 Vo 11 14 17 A
Effi ciency (Vi=48V, Io3=9A,Io5=6A, Tc=70°C) K 90 90 _ %
Dynamic Response
('Io/'t=0.2A/Psec.Vi=48V, Tc=25°C, either O/P)
Load change of 50% Io max; at any operating
load up to Iomax or Pomax Peak Deviation
outside settling point 2 _ %Vo nom
NOTE: 1. Worst case voltage conditions occur with full load drawn from one output only, zero being drawn from the other.
For worst case voltages at less extreme loading conditions, consult the factory.
INPUT
PARAMETER SYMBOL MIN TYP MAX UNITS
Operating Input Voltage
VSX60LDC Vi 18 24 36 VDC
VSX60MDC Vi 36 48 75 VDC
Maximum Input Current
(Vi=0V to Vi max, Io=Io max)
VSX60LDC Ii max 5.0 A
VSX60MDC Ii max 2.25
I/P Refl ected Ripple Current 400 mA p-p
No Load Input Current IiNL 50 mA
On/Off Activated Input Current IiQ 17 mA
OUTPUT Under any conditions, the voltage of V1 will always be greater or equal to that of V2.
VSX60XD35C
60 Watt Dual Output Quarter Brick DC/DC Converter
TDC_VSX60XD35C.B02 Page 2 of 4
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000www.murata-ps.com
PARAMETER SYMBOL MIN TYP MAX UNITS
Isolation Specifi cations
Isolation Capacitance _ _ 1000 _ pF
Isolation Resistance _ 10 _ _ M:
Feature Specifi cations
Remote On/Off (open collector equivalent,
signal referenced to -Vin terminal)
VSX60MD35C Preferred Logic (negative)
Logic Low - Module On
Logic High - Module Off
VSX60MD35-1C - Optional Logic (positive)
Logic Low - Module Off
Logic High - Module On
Logic Low: At Von/off = 0V Von/off 0 _ 50 Vdc
Ion/off _
200 PA
Turn On Time (Vo within 1% of steady state)
From Application of Vin _ _ 7 10 mSecs
From Remote On/Off Activation) _ _ 3 4 mSecs
Input Undervoltage Lockout
(Turn Off & Turn On Voltages Track)
Turn On _ 30 33 36 Vdc
Turn Off _ 27 30 33 Vdc
Input Overvoltage Lockout
(Turn Off & Turn On Voltages Track)
Turn Off _ 76 80 84 Vdc
Turn On _ 74.5 78.5 82.5 Vdc
Output Overvoltage Set Point
(Non-latching independent control loop)
2.5 Vo 2.7 2.9 3.2 Vdc
3.3 Vo 3.6 3.9 4.2 Vdc
Overtemperature Shutdown Tc 105 115 125 °C
Hysteresis 10 °C
Weight
VSX60MD35C, VSX60MD35-1C 67 Grams
VSX60MD35-UC, VSX60MD35-1UC
Output Trim
Tie Trim to +2.5 Vo for trim down 2.5 V2 _ -10
_ %
3.3 V1 _ -10
_ %
Tie Trim to O/P RTN for trim up 2.5 V2 _ 10
_ %
3.3 V1 _ 10 _ %
GENERAL
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of
no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures
within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering.
THROUGH-HOLE SOLDERING INFORMATION
VSX60XD35C
60 Watt Dual Output Quarter Brick DC/DC Converter
TDC_VSX60XD35C.B02 Page 3 of 4
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000www.murata-ps.com
Model Numbers
VSX60MD35C
VSX60MD35-UC
VSX60MD35-1C
VSX60LD35C
MECHANICAL
Dimensions are in inches (millimeters).
Tolerances: x.xx in. + 0.02 in.
x.xxx in. +0.01 in.
Pinout Key
1 +Vin
2 On/Off
3 -Vin
4 +2.5 Vout
5 O/P RTN
6 Trim
7 +3.3 Vout
2.30
(58.42)
1.50
(38.10)
.50
(12.70)
.145
(3.68)
.150
(3.81)
2.000
(50.80)
1.200
(30.48)
.150
(3.81)
PIN 1
M3 THREAD
4 PLACES
0.040 (1.02) 7 PLACES
NOTES:
1. Marked with: specifi c model ordered, date code, job
code.
2. MATERIAL: Units are encapsulated in a low thermal
resistance molding compound which has excellent
chemical resistance and electrical properties in high
humidity environments and over a wide operating
temperature range. The encapsulant and outer shell of
the unit have UL94V-0 ratings. Lead material is solder
plated to allow ease of solderability.
3. IMPORTANT: When utilizing the PEM nuts for
board mounting, it is required to follow guidelines in
application note DCAN-41 available on the web at
www.murata-ps.com.
.125 (3.18)
.125 (3.18)
.375 (9.53)
.000
.150
(3.81)
.000
.750
(19.05)
1
2
3
7
6
5
4
0.051 (1.30)
7 PLACES
0.144 (3.66)
4 PLACES
RECOMMENDED PCB HOLE PATTERN
(VIEW OF PCB, THROUGH UNIT)
.600
(15.24)
.600
(15.24)
.350
(8.89)
2.000
CASE OUTLINE
.375 (9.53)
.350
(8.89)
(50.80)
ORDERING INFORMATION
To Find Model Number
RoHS Compliant
Device Family
VSX60MD35 (Quarter Brick, 60 Watt DC/DC)
VSX60 -1 U C
Package
No Letter = Encapsulated; U = Unencapsulated
Logic: No Number = Preferred Logic (Negative);
1 = Optional Logic (Positive)
VSX60XD35C
60 Watt Dual Output Quarter Brick DC/DC Converter
TDC_VSX60XD35C.B02 Page 4 of 4
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000www.murata-ps.com
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without
notice. © 2009 Murata Power Solutions, Inc.
USA: Mansfi eld (MA), Tel: (508) 339-3000, email: sales@murata-ps.com
Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Japan: Tokyo, Tel: 81-3-3779-1031, email: japan@murata-ps.com
Kyoto, Tel: 81-75-955-7269, email: japan@murata-ps.com
China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
05/26/09