JS
SPECIFICATIONS
TYPICAL APPLICATIONS
MINIATURE PC BOARD TYPE
POWER RELAY JS RELAYS
VDE
mm inch
FEATURES
•Miniature size with universal terminal
footprint
• High contact capacity: 10 A
•TV-5 type available (Standard type)
1 Form A type → TV-5
1 Form C type → TV-5 (N.O. side only)
• VDE, TÜV also approved
• Sealed construction for automatic
cleaning (Standard type)
• Class B and F coil insulation type
also available.
• EN60335-1 GWT compliant (Tested
by VDE) type available
• Surge voltage 6 kV type also
available
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances.
(The suffix “F” should be added to the
part number)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
16
16
22
.630
.630
.866
RoHS Directive compatibility information
http://www.nais-e.com/
Contact
** Holding voltage should be 60% V of nominal voltage
Coil
Characteristics
Types Standard type Long
endurance type
Arrangement 1 Form A,
1 Form C 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 100 mΩ
Contact material AgSnO2 type
Rating
(resistive
load)
Nominal switching
capacity
10 A 250 V AC
10 A 125 V AC
6 A 277 V AC
10 A 250 V AC
10 A 125 V AC
10 A 277 V AC
Max. switching power 2,500 VA
Max. switching voltage 250 V AC, 100 V DC
Max. switching current 10 A (AC), 5 A (DC)
Min. switching
capacity#1 100 mA, 5 V DC
Expected
life (min.
ope.)
Mechanical
(at 180 cpm) 107
Electrical at 10 A
125 V AC,
6 A 277 V AC resistive
(standard)
10 A 277 V AC resistive
(High power)
1×1052×105
10 A 250 V AC resistive
(Standard: at 20 cpm)
(High power: at 20 cpm,
105°C 221°F)**
5 × 104
(No contact
only) 1.2 × 105
Nominal operating power 360 mW
Max. operating speed 20 cpm
Types Standard
type
Long
endurance type
Initial insulation resistance Min. 100 MΩ (at 500 V DC)
Initial
breakdown
voltage*1
Between open contacts 750 Vrms for 1 min.
Between contacts and
coil 1,500 Vrms for 1 min.
Operate time*2
(at nominal voltage) Max. 10 ms
Release time (without diode)*2
(at nominal voltage) Max. 10 ms
Temperature rise (at nominal voltage)
Max. 35°C,
resistive, nominal voltage
applied to coil.
Contact carrying current:
10A, at 70°C 158°F
Shock resistance Functional*398 m/s2 {10 G}
Destructive*4980 m/s2 {100 G}
Vibration resistance
Functional*510 to 55 Hz at double
amplitude of 1.6 mm
Destructive 10 to 55 Hz at double
amplitude of 2 mm
Conditions for operation,
transport and storage*6
(Not freezing and
condensing at low
temperature)
Ambient
temp.*7
–40°C to
+85°C
–40°F to
+185°F
–40°C to
+105°C
–40°F to
+221°F
Humidity 5 to 85% R.H.
Unit weight Approx.12 g .423 oz
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
*1Detection current: 10mA
*2Excluding contact bounce time
*3Half-wave pulse of sine wave: 11ms; detection time: 10µs
*4Half-wave pulse of sine wave: 6ms
*5Detection time: 10µs
*6Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
*7When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
1. Home appliances
Air conditioner, heater, etc.
2. Automotive
Power-window, car antenna, door-lock,
etc.
3. Office machines
PPC, facsimile, etc.
4. Vending machines
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.