Strap BatteryStrap Battery
4
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 259
PolySwitch Strap Batter y
Resettable Devices
Raychem Circuit Protection, pio-
neer of polymeric PTC resettable
devices, has developed several
material platforms specifically tai-
lored to help protect battery
applications. Each of these mate-
rial platforms offers different per-
formance characteristics,
allowing the engineer greater
design flexibility. Raychem Circuit
Protection’s battery protection
family includes SRP, LTP, LR4,
VTP, VLP, and VLR series, disc,
and special application strap
devices.
Benefits:
Many material platforms and
device form factors give engi-
neers more design flexibility
Compatible with high-volume
electronics assembly
Assists in meeting regulatory
requirements
Low resistance devices
increase battery operating time
Features:
Broad range of resettable
devices available
Current ratings from 0.7A to
9.0A
•Voltage ratings from 12V to 30V
Agency recognition, UL, CSA,
TÜV
Fast time-to-trip
Low resistance
Applications:
Mobile phone battery packs
Cordless phone battery packs
Mobile radio packs
Computer battery packs
Camcorder battery packs
PDA battery packs
Activation Temperature, Device Series, Hold Current
Devices in this section are grouped by:
260 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Step 1. Determine the circuit’s operating parameters.
Fill in the following information about the circuit:
Maximum ambient operating temperature
Normal operating current
Maximum operating voltage
(i.e., VTP210G is 16V max.)
Maximum interrupt current
Step 2. Select the PolySwitch device that will accommodate the
circuit’s maximum ambient temperature and
normal operating current.
Look across the top of Table B2 to find the temperature that most
closely matches the circuit’s maximum operating temperature. Look
down the column to find the value equal to or greater than the circuit's
normal operating current. Now look to the far left of that row to find the
part number for the PolySwitch strap device that will best accommo-
date the circuit. Devices in this section are grouped by typical activa-
tion temperature; therefore, your operating current requirement may be
found in more than one grouping.
The thermal derating curves located in Figure B3 are the normalized
representations of the data in Table B2.
Step 3. Compare the selected device’s electrical ratings with the
circuit’s maximum operating voltage and maximum inter-
rupt current.
Look down the first column of Table B3 to find the part number you
selected in Step 2. Look to the right in that row to find the device’s
maximum operating voltage (VMAX) and maximum interrupt current
(IMAX). Ensure that VMAX and IMAX are greater than or equal to the cir-
cuits maximum operating voltage and maximum interrupt current.
Step 4. Determine time-to-trip.
Time-to-trip is the amount of time it takes for a device to switch to a
high-resistance state once a fault current has been applied across the
device. Identifying the PolySwitch device’s time-to-trip is important in
order to provide the desired protection capabilities. If the device you
choose trips too fast, undesired or nuisance tripping will occur. If the
device trips too slowly, the components being protected may be
damaged before the device switches to a high resistance state.
Selection Guide for Strap Battery Devices
Strap Battery
4
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 261
Figures B19-25 show the typical time-to-trip at 20°C for each of the
PolySwitch devices.
If the PolySwitch device time-to-trip is too fast or too slow for the circuit, go
back to Step 2 and choose an alternate device.
Step 5. Match Thermal Cut-Off to Cell Chemistry.
Thermal cut-off is the temperature at which a PolySwitch device will trip when
sourced with a specific current. Figure B1 demonstrates how the resistance-
versus-temperature characteristics of various PolySwitch strap device series
differ by use of different material platforms. Figure B2 shows the thermal cut-
off behavior for each strap battery series device. Actual device performance
can vary depending on the application environment, and users should inde-
pendently test and evaluate each product in their application. Thermally sen-
sitive cell chemistries such as Li-ion and NiMH typically use devices with
lower thermal cut-off, which can provide enhanced thermal protection (VLR,
VLP, and VTP series). Less sensitive chemistries, like NiCd, typically use
devices with higher thermal cut-off temperatures (LR4, SRP series).
Step 6. Verify ambient operating conditions.
Ensure that your application’s minimum and maximum ambient tempera-
tures are within the operating temperature range of -40°C to 85°C (except
for VLR series, which is -40°C to 70°C).
Step 7. Verify the PolySwitch device dimensions.
Using dimensions in Table B4, compare the dimensions of the PolySwitch
device you selected with the application’s space considerations.
Selection Guide for Strap Battery Devices
Temperature (°C)
Resistance ()
0 20 40 60 80 100 120 140 160
0.001
0.01
0.1
1
10
100
1000
10000
100000
1000000
A
B
C
C
E
F
A = VLR
B = VLP
C = VTP
D = LTP
E = SRP
F = LR4
B
D
A
FE
D
Figure B1. Resistance vs. Temperature
Resistance at 20 °C ()
Thermal Cut-off Temperature (°C)
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16
0
20
40
60
80
100
120
140
160
180
AB
D
DE
F
B
E
A
F
A = VLR
B = VTP
C = VLP
D = LTP
E = SRP
F = LR4
C
C
Figure B2. Typical Thermal Cut-Off at 1 A
262 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Protection Application Selection Guide for Strap Battery Devices
PolySwitch Resettable Devices—Key Device Selection Criteria
Protection Application Additional Comments Installation Method Lowest Resistance Lowest Thermal Cut-off
Mobile phone battery packs NiCd Cylindrical LR4-17OU LTP070
(diameter greater LR4-190 LTP190
than AAA) LR4-260 LTP260
SRP200 LTP340
SRP420
Cylindrical TAC100-09 VTP170
(AAA cell) TAC170-09 VTP210G
TAC210
VTP170
Prismatic LR4-190
LR4-260
SRP120
SRP175
NiMH Cylindrical VLP270 VLR170
(diameter greater VTP210G VLR230
than AAA) LR4-190 VLP270
LR4-260 VTP210G
LTP180
LTP190
LTP260
Cylindrical VLP210 VLP210
(AAA cell) VTP170 VTP170
TAC100-09 VTP210G
TAC170-09 LTP180L (4 cells)
TAC210
Flexprint miniSMDE190 miniSMDE190
Prismatic VLP220 VLR170
VLP270 VLR230
VTP210G VLP220
LR4-190 VLP270
LR4-260 VTP210G
LR4-380 LTP180
Li-ion Cylindrical VLP220 VLR170
(diameter greater VLP270 VLR230
than AAA) VTP210G VLP220
LR4-190 VLP270
LR4-260 VTP210G
Flexprint miniSMDE190 miniSMDE190
Prismatic VLP220 VLR170
VLP270 VLR230
VTP210G VLP270
PSR-23096 (single cell) VTP210G
PSR-22631 (single cell) VTP175
The guide below lists PolySwitch
devices which are typically used in
these applications. The following
pages contain the specifications for
the part numbers recommended
below. Once a device is selected,
the user should evaluate and test
each product for its intended
application.
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 263
4
PolySwitch Resettable Devices—Key Device Selection Criteria
Protection Application Additional Comments Installation Method Lowest Resistance Lowest Thermal Cut-off
Cordless phone battery packs NiCd Cylindrical SRP120 LTP070
SRP175 LTP100
VTP210G VTP210G
NiMH Cylindrical LTP070 LTP070
LTP100 LTP100
VTP210G VTP210G
Mobile radio packs NiCd Cylindrical LR4-380 LTP260
LR4-730 LTP300
SRP350 LTP340
NiMH Cylindrical LR4-380 LTP260
LR4-730 LTP300
SRP350 LTP340
Computer battery packs NiMH Cylindrical LR4-380 LTP260
LR4-450 LTP340
LR4-550
LR4-600
LR4-730
SRP420
SRP350
Li-ion Cylindrical LR4-380
LR4-450
LR4-550
LR4-600
LR4-730
SRP350
SRP420
Prismatic Consult Local Rep Consult Local Rep
Camcorder battery packs NiCd or Li-Ion Cylindrical LR4-450 VTP210G
LR4-550
LR4-600
LR4-730
PDA Li-Ion Prismatic VLP220 VLR170
VLP270 VLR230
VTP110
VTP170
VTP210G
LTP070
LTP100
LTP180
Protection Application Selection Guide for Strap Battery Devices continued
264 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Table B1. Product Series – Current Rating, Voltage Rating/Typical Resistance for Strap Battery Devices
VLR VLP VTP LTP SRP LR4 TAC miniSMDE
Hold Typical Activation Temperature
Current (A) 85°C 90°C 90°C 110°C 125°C 125°C 110° 125°C 110°C
0.70 —— 15V/0.15——
1.00 24V/0.100——15V/0.120——
1.10 16V/0.054——
1.20 ——15V/0.123——
1.70 12V/0.02516V/0.041——15V/0.061 15V/0.074
1.75 12V/0.02416V/0.040 15V/0.070——
1.80 24V/0.054——
1.90 24V/0.044 15V/0.056—— 16V/0.032
2.00 16V/0.031 30V/0.045——
2.10 16V/0.02416V/0.024———— 15V/0.049
2.20 16V/0.023———
2.30 12V/0.015————
2.40 16V/0.020——
2.60 24V/0.034 15V/0.031——
2.70 16V/0.015———
3.00 24V/0.023——
3.40 24V/0.022——
3.50 ——30V/0.024——
3.80 ———15V/0.020——
4.20 ——30V/0.018——
4.50 ———20V/0.016——
5.50 ———20V/0.013——
6.00 ———20V/0.011——
7.30 ———20V/0.009——
9.00 ———20V/0.008——
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 265
4
Table B2. Thermal Derating for Strap Battery Devices [Hold Current (A) at Ambient Temperature (˚C)]
Maximum Ambient Temperature
-40˚C -20˚C 0˚C 20˚C 25˚C 40˚C 50˚C 60˚C 70˚C 80˚C 85˚C
Part Number Amps
85°C Typical Activation
VLR †
VLR170 3.5 2.9 2.4 1.84 1.7 1.2 1.0 0.7 0.3
VLR170U 3.5 2.9 2.4 1.84 1.7 1.2 1.0 0.7 0.3
VLR175 3.5 2.9 2.4 1.87 1.75 1.3 1.0 0.8 0.3
VLR175L 3.5 2.9 2.4 1.87 1.75 1.3 1.0 0.8 0.3
VLR230 5.0 4.2 3.4 2.52 2.3 1.7 1.3 0.9 0.4
VLR230S 5.0 4.2 3.4 2.52 2.3 1.7 1.3 0.9 0.4
VLR230SU 5.0 4.2 3.4 2.52 2.3 1.7 1.3 0.9 0.4
VLR230U 5.0 4.2 3.4 2.52 2.3 1.7 1.3 0.9 0.4
90°C Typical Activation
VLP †
VLP210 4.3 3.6 2.9 2.31 2.1 1.6 1.3 1.0 0.6 0.3 0.1
VLP220 4.5 3.8 3.0 2.45 2.2 1.7 1.4 1.1 0.7 0.3 0.1
VLP270 5.6 4.7 4.0 3.05 2.7 2.2 1.7 1.4 0.9 0.4 0.1
90°C Typical Activation
VTP †
VTP110 2.0 1.7 1.4 1.02 1.1 0.8 0.6 0.5 0.3 0.2 0.1
VTP170 3.2 2.7 2.2 1.80 1.7 1.3 1.0 0.8 0.5 0.3 0.1
VTP170SS 3.2 2.7 2.2 1.80 1.7 1.3 1.0 0.8 0.5 0.3 0.1
VTP170X 3.2 2.7 2.2 1.80 1.7 1.3 1.0 0.8 0.5 0.3 0.1
VTP170XS 3.2 2.7 2.2 1.80 1.7 1.3 1.0 0.8 0.5 0.3 0.1
VTP175 3.2 2.7 2.2 1.84 1.75 1.3 1.0 0.8 0.5 0.3 0.1
VTP175L 3.2 2.7 2.2 1.84 1.75 1.3 1.0 0.8 0.5 0.3 0.1
VTP175U 3.2 2.7 2.2 1.84 1.75 1.3 1.0 0.8 0.5 0.3 0.1
VTP200G 3.7 3.2 2.6 2.12 2.0 1.5 1.2 0.9 0.5 0.3 0.1
VTP200U 3.7 3.2 2.6 2.12 2.0 1.5 1.2 0.9 0.5 0.3 0.1
VTP210G 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210L 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210S 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210SL 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210SL-19.2/5.8 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210SS 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP210ULD 4.1 3.5 2.9 2.26 2.1 1.6 1.3 1.0 0.7 0.4 0.1
VTP240 4.4 3.7 3.1 2.54 2.4 1.8 1.5 1.2 0.9 0.5 0.1
† = Product electrical characteristics determined at 25°C
110°C Typical Activation
LTP
LTP070 1.1 1.0 0.8 0.7 0.65 0.5 0.4 0.35 0.2 0.2 0.1
LTP070S 1.1 1.0 0.8 0.7 0.65 0.5 0.4 0.3 0.2 0.2 0.1
LTP100 1.8 1.6 1.4 1.0 0.99 0.8 0.7 0.6 0.4 0.3 0.2
LTP100S 1.8 1.6 1.4 1.0 0.99 0.8 0.7 0.6 0.4 0.3 0.2
LTP100SL 1.8 1.6 1.4 1.0 0.99 0.8 0.7 0.6 0.4 0.3 0.2
LTP100SS 1.8 1.6 1.4 1.0 0.99 0.8 0.7 0.6 0.4 0.3 0.2
LTP180 3.1 2.6 2.2 1.8 1.67 1.3 1.1 0.9 0.6 0.4 0.3
LTP180L 3.1 2.6 2.2 1.8 1.67 1.3 1.1 0.9 0.6 0.4 0.3
Table B2. Thermal Derating for Strap Battery Devices [Hold Current (A) at Ambient Temperature (˚C)]
continued Maximum Ambient Temperature
-40˚C -20˚C 0˚C 20˚C 25˚C 40˚C 50˚C 60˚C 70˚C 80˚C 85˚C
Part Number Amps
110°C Typical Activation
LTP , continued
LTP180S 3.1 2.6 2.2 1.8 1.67 1.3 1.1 0.9 0.6 0.4 0.3
LTP190 3.3 2.8 2.4 1.9 1.79 1.4 1.2 1.1 0.7 0.5 0.4
LTP260 4.3 3.7 3.1 2.6 2.42 1.9 1.6 1.4 1.1 0.8 0.6
LTP300 5.1 4.4 3.7 3.0 2.82 2.3 1.9 1.6 1.2 0.9 0.7
LTP340 5.5 4.7 4.0 3.4 3.17 2.6 2.2 1.9 1.5 1.1 0.9
miniSMDE
miniSMDE190 3.0 2.6 2.2 1.9 1.74 1.4 1.2 1.1 0.7 0.5 0.4
TAC
TAC100-09 1.6 1.4 1.2 1.0 0.92 0.7 0.6 0.5 0.4 0.2 0.2
125°C Typical Activation
LR4
LR4-170U 2.5 2.2 2.0 1.7 1.64 1.4 1.3 1.2 1.0 0.9 0.8
LR4-190 2.8 2.5 2.3 1.9 1.86 1.6 1.5 1.4 1.2 1.1 1.0
LR4-190S 2.8 2.5 2.3 1.9 1.86 1.6 1.5 1.4 1.2 1.1 1.0
LR4-260 3.8 3.4 3.1 2.6 2.54 2.2 2.0 1.9 1.7 1.4 1.3
LR4-260S 3.8 3.4 3.1 2.6 2.54 2.2 2.0 1.9 1.7 1.4 1.3
LR4-380 5.4 4.9 4.4 3.8 3.64 3.3 3.0 2.8 2.5 2.3 2.1
LR4-450 6.5 5.8 5.3 4.5 4.38 3.9 3.6 3.3 2.9 2.6 2.4
LR4-550 7.6 6.9 6.2 5.5 5.32 4.7 4.3 4.0 3.6 3.2 3.0
LR4-600 8.7 7.8 7.1 6.0 5.86 5.2 4.7 4.4 3.9 3.4 3.2
LR4-730 10.5 9.5 8.6 7.3 7.13 6.3 5.7 5.4 4.7 4.2 4.0
LR4-900 12.7 11.4 10 9.0 8.5 7.5 6.8 6.2 5.5 4.9 4.5
SRP
SRP120 1.9 1.7 1.5 1.2 1.17 1.0 0.9 0.8 0.6 0.5 0.4
SRP120L 1.9 1.7 1.5 1.2 1.17 1.0 0.9 0.8 0.6 0.5 0.4
SRP120S 1.9 1.7 1.5 1.2 1.17 1.0 0.9 0.8 0.6 0.5 0.4
SRP175 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8
SRP175L 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8
SRP175S 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8
SRP175SS 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8
SRP200 3.1 2.8 2.5 2.0 1.97 1.7 1.5 1.4 1.2 1.0 0.9
SRP350 5.3 4.8 4.3 3.5 3.44 3.0 2.7 2.5 2.1 1.8 1.7
SRP420 6.3 5.7 5.1 4.2 4.11 3.6 3.3 3.0 2.6 2.2 2.1
TAC
TAC170-09 2.4 2.2 2.0 1.7 1.67 1.5 1.4 1.3 1.1 1.0 1.0
TAC210 2.8 2.6 2.3 2.1 2.03 1.7 1.6 1.5 1.3 1.2 1.1
266 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 267
4
Temperature (°C)
Percent of Rated Hold and Trip Current
A
A = LR4
B = SRP
C = LTP
D = VTP, VLP
E = VLR
B
C
D
E
40
50 30 20 10 0 102030405060708090
0
20
40
60
80
100
120
140
160
180
200
A
B
C
D
E
Figure B3. Thermal Derating
268 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Table B3. Product Electrical Characteristics for Strap Battery Devices
IHITVMAX IMAX PD TYP Max. Time-to-Trip RMIN RTYP RMAX RTripped TYP R1 MAX Figures for
Part Number (A) (A) (VDC)(A) (W) (A) (s) ()()()()()Dimensions
85°C Typical Activation
VLR
VLR170 1.7 4.1 12 100 1.4 8.5 5.0 0.018 0.025 0.032 0.050 0.064 B5
VLR170U 1.7 4.1 12 100 1.4 8.5 5.0 0.018 0.025 0.032 0.050 0.064 B8
VLR175 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.024 0.031 0.048 0.062 B5
VLR175L 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.024 0.031 0.048 0.062 B5
VLR230 2.3 5.0 12 100 1.4 10.0 5.0 0.012 0.015 0.018 0.030 0.036 B5
VLR230S 2.3 5.0 12 100 1.4 8.75 5.0 0.012 0.015 0.018 0.030 0.036 B6
VLR230SU 2.3 5.0 12 100 1.4 8.75 5.0 0.012 0.015 0.018 0.030 0.036 B6
VLR230U 2.3 5.0 12 100 1.4 8.75 5.0 0.012 0.015 0.018 0.030 0.036 B8
90°C Typical Activation
VLP
VLP210 2.1 5.0 16 60 0.8 10.5 5.0 0.018 0.024 0.030 0.048 0.060 B4
VLP220 2.1 5.3 16 60 0.8 11.0 5.0 0.017 0.023 0.029 0.046 0.058 B5
VLP270 2.7 6.5 16 60 1.2 13.5 5.0 0.012 0.015 0.018 0.030 0.036 B5
90°C Typical Activation
VTP
VTP110 1.1 2.7 16 100 0.7 7.0 5.0 0.038 0.054 0.070 0.108 0.140 B8
VTP170 1.7 3.4 16 100 1.0 8.5 3.0 0.030 0.041 0.052 0.082 0.105 B4
VTP170SS 1.7 3.4 16 100 1.0 8.5 3.0 0.030 0.041 0.052 0.082 0.105 B11
VTP170X 1.7 3.4 16 100 0.7 8.5 5.0 0.030 0.041 0.052 0.082 0.105 B5
VTP170XS 1.7 3.4 16 100 0.7 10.0 5.0 0.030 0.041 0.052 0.082 0.105 B6
VTP175 1.75 3.6 16 100 0.8 8.75 5.0 0.029 0.040 0.051 0.080 0.102 B5
VTP175L 1.75 3.6 16 100 0.8 8.75 5.0 0.029 0.040 0.051 0.080 0.102 B5
VTP175U 1.75 3.6 16 100 0.8 8.75 5.0 0.029 0.040 0.051 0.080 0.102 B8
VTP200G 2.0 4.7 16 100 0.9 10.0 5.0 0.022 0.031 0.039 0.062 0.078 B5
VTP200U 2.0 4.7 16 100 0.9 10.0 5.0 0.022 0.031 0.039 0.062 0.078 B8
VTP210G 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B5
VTP210L 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B5
VTP210S 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B6
VTP210SL 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B6
VTP210SL-19.2/5.8 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B6
VTP210SS 2.1 4.7 16 100 1.2 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B7
VTP210ULD 2.1 4.7 16 100 1.5 10.0 5.0 0.018 0.024 0.030 0.048 0.060 B8
VTP240 2.4 5.9 16 100 1.0 12.0 5.0 0.014 0.020 0.026 0.040 0.052 B5
110°C Typical Activation
LTP
LTP070 0.7 1.45 15 100 0.7 3.5 5.0 0.100 0.150 0.200 0.300 0.340 B9
LTP070S 0.7 1.45 15 100 0.7 3.5 5.0 0.100 0.150 0.200 0.300 0.340 B10
LTP100 1.0 2.50 24 100 0.9 5.0 7.0 0.070 0.100 0.130 0.200 0.260 B9
LTP100S 1.0 2.50 24 100 0.9 5.0 7.0 0.070 0.100 0.130 0.200 0.260 B10
LTP100SL 1.0 2.50 24 100 0.9 5.0 7.0 0.070 0.100 0.130 0.200 0.260 B10
LTP100SS 1.0 2.50 24 100 0.9 5.0 7.0 0.070 0.100 0.130 0.200 0.260 B11
LTP180 1.8 3.80 24 100 1.0 9.0 2.9 0.040 0.054 0.068 0.108 0.120 B9
LTP180L 1.8 3.80 24 100 1.0 9.0 2.9 0.040 0.054 0.068 0.108 0.120 B9
LTP180S 1.8 3.80 24 100 1.0 9.0 2.9 0.040 0.054 0.068 0.108 0.120 B10
LTP190 1.9 4.20 24 100 1.9 10.0 3.0 0.030 0.044 0.057 0.088 0.100 B9
LTP260 2.6 5.20 24 100 1.3 13.0 5.0 0.025 0.034 0.042 0.068 0.076 B9
LTP300 3.0 6.30 24 100 1.7 15.0 4.0 0.015 0.023 0.031 0.046 0.055 B9
LTP340 3.4 6.80 24 100 1.6 17.0 5.0 0.016 0.022 0.027 0.044 0.050 B9
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 269
4
Table B3. Product Electrical Characteristics for Strap Battery Devices continued
IHITVMAX IMAX PD TYP Max. Time-to-Trip RMIN RTYP RMAX RTripped TYP R1 MAX Figures for
Part Number (A) (A) (VDC) (A) (W) (A) (s) ()()()()()Dimensions
miniSMDE
miniSMDE190 1.9 3.8 16 100 1.5 10.0 2.0 0.024 0.032 0.040 0.060 0.080* B18
TAC
TAC100-09 1.0 2.4 15 50 1.2 5.0 5.0 0.085 0.120 0.155 0.240 0.300 B12
125°C Typical Activation
LR4
LR4-170U 1.7 3.4 15 100 0.8 8.5 5.0 0.044 0.061 0.078 0.089 0.114 B15
LR4-190 1.9 3.9 15 100 0.8 9.5 5.0 0.039 0.056 0.072 0.079 0.102 B13
LR4-190S 1.9 3.9 15 100 0.8 9.5 5.0 0.039 0.056 0.072 0.079 0.102 B14
LR4-260 2.6 5.8 15 100 1.0 13.0 5.0 0.020 0.031 0.042 0.046 0.063 B13
LR4-260S 2.6 5.8 15 100 1.0 13.0 5.0 0.020 0.031 0.042 0.046 0.063 B14
LR4-380 3.8 8.3 15 100 1.2 19.0 5.0 0.013 0.020 0.026 0.028 0.037 B13
LR4-450 4.5 8.9 20 100 1.4 22.5 5.0 0.011 0.016 0.020 0.022 0.028 B13
LR4-550 5.5 10.5 20 100 2.0 27.5 5.0 0.009 0.013 0.016 0.018 0.022 B13
LR4-600 6.0 11.7 20 100 1.7 30.0 5.0 0.007 0.011 0.014 0.015 0.019 B13
LR4-730 7.3 14.1 20 100 1.9 30.0 5.0 0.006 0.009 0.012 0.011 0.015 B13
LR4-900 9.0 16.7 20 100 3.0 45.0 5.0 0.006 0.008 0.010 0.011 0.014 B13
SRP
SRP120 1.2 2.7 15 100 0.8 6.0 5.0 0.085 0.123 0.160 0.170 0.220 B9
SRP120L 1.2 2.7 15 100 0.8 6.0 5.0 0.085 0.123 0.160 0.170 0.220 B9
SRP120S 1.2 2.7 15 100 0.8 6.0 5.0 0.085 0.123 0.160 0.170 0.220 B16
SRP175 1.75 3.8 15 100 0.9 8.75 5.0 0.050 0.070 0.090 0.093 0.120 B9
SRP175L 1.75 3.8 15 100 0.9 8.75 5.0 0.050 0.070 0.090 0.093 0.120 B9
SRP175S 1.75 3.8 15 100 0.9 8.75 5.0 0.050 0.070 0.090 0.093 0.120 B16
SRP175SS 1.75 3.8 15 100 0.9 8.75 5.0 0.050 0.070 0.090 0.093 0.120 B17
SRP200 2.0 4.4 30 100 1.6 10.0 4.0 0.030 0.045 0.060 0.075 0.100 B9
SRP350 3.5 6.3 30 100 1.9 20.0 3.0 0.017 0.024 0.031 0.040 0.050 B9
SRP420 4.2 7.6 30 100 2.2 20.0 6.0 0.012 0.018 0.024 0.030 0.040 B9
TAC
TAC170-09 1.7 3.7 15 50 1.2 8.5 5.0 0.05 0.074 0.098 0.106 0.140 B12
TAC210 2.1 4.7 15 50 1.3 10.5 5.0 0.035 0.049 0.062 0.089 0.113 B12
Notes:
IH= Hold current: maximum current device will pass without interruption in 20°C still air unless otherwise specified.
IT= Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air unless otherwise specified.
VMAX = Maximum voltage device can withstand without damage at rated current.
IMAX = Maximum fault current device can withstand without damage at rated voltage.
PD= Power dissipated from device when in the tripped state in 20°C still air unless otherwise specified.
RMIN = Minimum resistance of device as supplied at 20°C unless otherwise specified.
RTYP = Typical resistance of device as supplied at 20°C unless otherwise specified.
RTripped Typ = Typical resistance, measured at 20°C unless otherwise specified, of device one hour after being tripped the first time.
RMAX = Maximum resistance of device as supplied at 20°C unless otherwise specified.
†= Product electrical characteristics determined at 25°C.
* = R1max value for this device is the maximum resistance of the device at 20°C one hour after reflow.
270 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Figures B4–B18. Physical Description for Dimensions
A
C
B
F
DE
Figure B6
A
CF
B
D E
Figure B4
A
C
B
F
DE
Figure B5
A
C
B
DE
F
Figure B9
A
C
B
DE
F
Figure B7
C
B
A
DE
F
Figure B8
A
C
B
E
D
F
Figure B12
DE
F
A
C
B
Figure B10
A
C
B
DE
F
Figure B11
C
B
A
E
D
F
Figure B15
A
C
B
E
D
F
Figure B13
A
C
B
E
D
F
Figure B14
B
C
A
D
Figure B18
A
C
B
E
D
F
Figure B16
A
C
B
D
F
E
Figure B17
Note: All slit parts are 0.5mm x 4.0mm nom. (0.02 in x 0.16 in)
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 271
Table B4. Dimensions for Strap Battery Devices in Millimeters (Inches)
Dimension
ABCDEF
Part Number Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Figures
85°C Typical Activation
VLR
VLR170 20.8 23.2 0.8 3.5 3.9 4.5 6.5 4.5 6.5 2.4 2.6 B5
(0.82) (0.91) (0.03) (0.14) (0.15) (0.18) (0.26) (0.18) (0.26) (0.09) (0.10)
VLR170U 20.8 23.2 0.7 3.5 3.7 5.3 6.7 5.3 6.7 2.4 2.6 B8
(0.82) (0.91) (0.03) (0.14) (0.15) (0.21) (0.26) (0.21) (0.26) (0.09) (0.10)
VLR175 23.0 24.5 0.8 2.9 3.3 4.7 7.2 3.8 5.4 2.4 2.6 B5
(0.91) (0.96) (0.03) (0.11) (0.13) (0.19) (0.28) (0.15) (0.21) (0.09) (0.10)
VLR175L 29.3 31.7 0.8 2.9 3.3 5.2 6.8 10.0 12.5 2.4 2.6 B5
(1.15) (1.25) (0.03) (0.11) (0.13) (0.21) (0.27) (0.39) (0.49) (0.09) (0.10)
VLR230 20.9 23.1 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B5
(0.82) (0.91) (0.03) (0.19) (0.21) (0.16) (0.23) (0.16) (0.23) (0.15) (0.16)
VLR230S 20.9 23.1 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B6
(0.82) (0.91) (0.03) (0.19) (0.21) (0.16) (0.23) (0.16) (0.23) (0.15) (0.16)
VLR230SU 20.9 23.1 0.7 4.9 5.1 4.1 6.0 4.1 6.0 3.9 4.1 B6
(0.82) (0.91) (0.03) (0.19) (0.20) (0.16) (0.24) (0.16) (0.24) (0.15) (0.16)
VLR230U 20.9 23.1 0.7 4.9 5.1 4.1 6.0 4.1 6.0 3.9 4.1 B8
(0.82) (0.91) (0.03) (0.19) (0.20) (0.16) (0.24) (0.16) (0.24) (0.15) (0.16)
90°C Typical Activation
VLP
VLP210 15.4 17.5 0.6 0.8 6.7 7.3 4.0 6.2 4.0 6.2 3.9 4.1 B4
(0.606) (0.689) (0.02) (0.03) (0.265) (.287) (0.157) (0.244) (0.157) (0.244) (0.15) (0.16)
VLP220 21.1 23.3 0.6 0.8 3.5 3.9 5.1 6.8 5.1 6.8 2.9 3.1 B5
(0.83) (.92) (0.02) (0.03) (0.13) (0.15) (0.20) (0.27) (0.20) (0.27) (0.11) (0.12)
VLP270 20.9 23.1 0.6 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B5
(0.82) (0.91) (0.02) (0.03) (0.19) (0.21) (0.16) (0.23) (0.16) (0.23) (0.15) (0.16)
90°C Typical Activation
VTP
VTP110 23.6 25.6 0.7 2.7 2.9 7.0 8.0 7.0 8.0 2.3 2.5 B8
(0.93) (1.01) (0.03) (0.11) (0.11) (0.28) (0.32) (0.28) (0.32) (0.09) (0.10)
VTP170 15.4 17.5 0.5 0.8 7.0 7.4 4.0 6.2 4.0 6.2 3.9 4.1 B4
(0.606) (0.689) (0.02) (0.03) (0.275) (0.292) (0.157) (0.244) (0.157) (0.244) (0.15) (0.16)
VTP170SS 15.4 17.5 0.5 0.8 7.0 7.4 4.0 6.2 4.0 6.2 3.9 4.1 B11
(0.606) (0.689) (0.02) (0.03) (0.275) (0.292) (0.157) (0.244) (0.157) (0.244) (0.154) (0.161)
VTP170X 20.9 22.9 0.5 0.8 4.9 5.3 6.0 8.6 6.0 8.6 3.9 4.1 B5
(0.82) (0.90) (0.02) (0.03) (0.19) (0.21) (0.23) (0.34) (0.23) (0.34) (0.15) (0.16)
VTP170XS 20.9 22.9 0.5 0.8 4.9 5.3 6.0 8.6 6.0 8.6 3.9 4.1 B6
(0.82) (0.90) (0.02) (0.03) (0.19) (0.21) (0.23) (0.34) (0.23) (0.34) (0.15) (0.16)
VTP175 21.2 23.2 0.8 3.5 3.9 4.6 6.6 4.6 6.6 2.9 3.1 B5
(0.83) (0.91) (0.03) (0.14) (0.15) (0.18) (0.26) (0.18) (0.26) (0.11) (0.12)
VTP175L 25.8 28.2 0.8 3.5 3.9 5.7 7.3 8.7 10.3 2.4 2.6 B5
(1.02) (1.11) (0.03) (0.13) (0.15) (0.22) (0.29) (0.34) (0.41) (0.09) (0.10)
VTP175U 21.2 23.2 0.7 3.5 3.7 5.6 6.8 5.6 6.8 2.9 3.1 B8
(0.83) (0.91) (0.03) (0.13) (0.15) (0.22) (0.27) (0.22) (0.27) (0.11) (0.12)
VTP200G 20.9 23.1 0.8 4.1 4.5 3.0 4.8 3.0 4.8 2.9 3.1 B5
(0.82) (0.91) (0.03) (0.16) (0.18) (0.11) (0.19) (0.11) (0.19) (0.11) (0.12)
VTP200U 20.9 23.1 0.7 4.1 4.3 4.0 5.4 4.0 5.4 2.9 3.1 B8
(0.82) (0.91) (0.03) (0.16) (0.17) (0.16) (0.21) (0.16) (0.21) (0.11) (0.12)
VTP210G 20.9 23.1 0.6 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B5
(0.82) (0.91) (0.02) (0.03) (0.19) (0.21) (0.16) (0.23) (0.16) (0.23) (0.15) (0.16)
VTP210L 24.0 26.0 0.6 0.8 4.9 5.3 5.0 7.1 5.0 7.1 3.9 4.1 B5
(0.94) (1.02) (0.02) (0.03) (0.19) (0.21) (0.20) (0.28) (0.20) (0.28) (0.15) (0.16)
4
272 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Table B4. Dimensions for Strap Battery Devices in Millimeters (Inches) continued
Dimension
AB C D EF
Part Number Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Figures
90°C Typical Activation
VTP, continued
VTP210S 20.9 23.1 0.6 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B6
(0.82) (0.91) (0.02) (0.03) (0.19) (0.21) (0.16) (0.28) (0.16) (0.23) (0.15) (0.16)
VTP210SL 29.0 32.0 0.6 0.8 4.9 5.3 3.5 5.8 12.5 14.5 3.9 4.1 B6
(1.14) (1.26) (0.02) (0.03) (0.19) (0.21) (0.13) (0.23) (0.49) (0.57) (0.15) (0.16)
VTP210SL-19.2/5.8 34.0 37.0 0.8 4.9 5.3 16.8 19.2 4.1 5.8 3.9 4.1 B6
(1.33) (1.46) (0.03) (0.19) (0.21) (0.66) (0.76) (0.16) (0.23) (0.15) (0.16)
VTP210SS 20.9 23.1 0.6 0.8 4.9 5.3 4.1 5.8 4.1 5.8 3.9 4.1 B7
(0.82) (0.91) (0.02) (0.03) (0.19) (0.21) (0.16) (0.23) (0.16) (0.23) (0.15) (0.16)
VTP210ULD 22.8 25.2 0.8 4.9 5.1 7.8 9.2 2.9 4.1 2.9 3.1 B8
(0.89) (1.00) (0.03) (0.19) (0.20) (0.30) (0.37) (0.11) (0.17) (0.11) (0.13)
VTP240 23.8 26.2 0.8 4.9 5.3 3.5 5.7 3.5 5.7 3.9 4.1 B5
(0.93) (1.03) (0.03) (0.19) (0.21) (0.13) (0.23) (0.13) (0.23) (0.15) (0.16)
110°C Typical Activation
LTP
LTP070 19.9 22.1 0.7 1.2 4.9 5.2 5.5 7.5 5.5 7.5 3.9 4.1 B9
(0.783) (0.870) (0.027) (0.048) (0.192) (0.205) (0.216) (0.296) (0.216) (0.296) (0.153) (0.162)
LTP070S 19.9 22.1 0.7 1.2 4.9 5.2 5.5 7.5 5.5 7.5 3.9 4.1 B10
(0.783) (0.870) (0.027) (0.048) (0.192) (0.205) (0.216) (0.296) (0.216) (0.296) (0.153) (0.162)
LTP100 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B9
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LTP100S 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B10
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LTP100SL 29.0 32.0 0.6 1.0 4.9 5.2 3.5 5.5 12.5 14.5 3.9 4.1 B10
(1.14) (1.26) (0.02) (0.04) (0.19) (0.20) (0.13) (0.22) (0.49) (0.57) (0.15) (0.16)
LTP100SS 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B11
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LTP180 24.0 26.0 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B9
(0.94) (1.02) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LTP180L 35.5 37.5 0.6 1.0 4.9 5.2 9.7 11.0 9.7 11.0 3.9 4.1 B9
(1.40) (1.48) (0.02) (0.04) (0.19) (0.20) (0.38) (0.44) (0.38) (0.44) (0.15) (0.16)
LTP180S 24.0 26.0 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B10
(0.94) (1.02) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LTP190 21.3 23.4 0.5 1.1 10.2 11.0 5.0 7.6 5.0 7.6 4.8 5.4 B9
(0.84) (0.92) (0.02) (0.04) (0.40) (0.43) (0.20) (0.30) (0.20) (0.30) (0.19) (0.21)
LTP260 24.0 26.0 0.6 1.0 10.8 11.9 5.0 7.0 5.0 7.0 5.9 6.1 B9
(0.94) (1.02) (0.02) (0.04) (0.43) (0.47) (0.20) (0.28) (0.20) (0.28) (0.23) (0.24)
LTP300 28.4 31.8 0.5 1.1 13.0 13.5 6.3 8.9 6.3 8.9 6.0 6.6 B9
(1.12) (1.25) (0.02) (0.04) (0.51) (0.53) (0.25) (0.35) (0.25) (0.35) (0.24) (0.26)
LTP340 24.0 26.0 0.6 1.0 14.8 15.9 4.0 5.0 4.0 5.0 5.9 6.1 B9
(0.94) (1.02) (0.02) (0.04) (0.58) (0.63) (0.16) (0.20) (0.16) (0.20) (0.23) (0.24)
miniSMDE
miniSMDE190 11.15 11.51 0.33 0.53 4.83 5.33 0.51 1.02 B18
(0.439) (0.453) (0.013) (0.021) (0.19) (0.21) (0.02) (0.04)
TAC
TAC100-09 16.5 17.5 0.9 9.5 10.5 9.4 10.0 5.0 5.2 0.8 1.2 B12
(0.65) (0.69) (0.036) (0.37) (0.45) (0.37) (0.040) (0.19) (0.21) (0.03) (0.05)
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 273
Table B4. Dimensions for Strap Battery Devices in Millimeters (Inches) continued
Dimension
AB CDEF
Part Number Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Figures
125°C Typical Activation
LR4
LR4-170U 19.0 21.0 0.5 0.7 3.8 4.0 5.3 6.5 5.3 6.5 2.9 3.1 B15
(0.75) (0.83) (0.02) (0.03) (0.15) (0.16) (0.21) (0.26) (0.21) (0.26) (0.11) (0.12)
LR4-190 19.9 22.1 0.6 1.0 4.9 5.5 5.5 7.5 5.5 7.5 3.9 4.1 B13
(0.78) (0.87) (0.02) (0.04) (0.19) (0.22) (0.22) (0.30) (0.22) (0.30) (0.15) (0.16)
LR4-190S 19.9 22.1 0.6 1.0 4.9 5.5 5.5 7.5 5.5 7.5 3.9 4.1 B14
(0.78) (0.87) (0.02) (0.04) (0.19) (0.22) (0.22) (0.30) (0.22) (0.30) (0.15) (0.16)
LR4-260 20.9 23.1 0.6 1.0 4.9 5.5 4.1 5.5 4.1 5.5 3.9 4.1 B13
(0.82) (0.91) (0.02) (0.04) (0.19) (0.22) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LR4-260S 20.9 23.1 0.6 1.0 4.9 5.5 4.1 5.5 4.1 5.5 3.9 4.1 B14
(0.82) (0.91) (0.02) (0.04) (0.19) (0.22) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
LR4-380 24.0 26.0 0.6 1.0 6.9 7.5 4.1 5.5 4.1 5.5 4.9 5.1 B13
(0.94) (1.02) (0.02) (0.04) (0.27) (0.30) (0.16) (0.22) (0.16) (0.22) (0.19) (0.20)
LR4-450 24.0 26.0 0.6 1.0 9.9 10.5 5.3 6.7 5.3 6.7 5.9 6.1 B13
(0.94) (1.02) (0.02) (0.04) (0.41) (0.39) (0.21) (0.26) (0.21) (0.26) (0.23) (0.24)
LR4-550 35.0 37.0 0.6 1.0 6.9 7.5 5.3 6.7 5.3 6.7 4.9 5.1 B13
(1.38) (1.46) (0.02) (0.04) (0.27) (0.30) (0.21) (0.26) (0.21) (0.26) (0.19) (0.20)
LR4-600 24.0 26.0 0.6 1.0 13.9 14.5 4.1 5.5 4.1 5.5 5.9 6.1 B13
(0.95) (1.02) (0.02) (0.04) (0.55) (0.57) (0.16) (0.22) (0.16) (0.22) (0.23) (0.24)
LR4-730 27.1 29.1 0.6 1.0 13.9 14.5 4.1 5.5 4.1 5.5 5.9 6.1 B13
(1.06) (1.15) (0.02) (0.04) (0.54) (0.57) (0.16) (0.22) (0.16) (0.22) (0.23) (0.24)
LR4-900 45.4 47.6 0.9 1.3 7.9 8.5 4.6 6.2 4.6 6.2 5.9 6.1 B13
(1.79) (1.87) (0.04) (0.05) (0.31) (0.33) (0.18) (0.24) (0.18) (0.24) (0.23) (0.24)
SRP
SRP120 19.9 22.1 0.6 1.0 4.9 5.2 5.5 7.5 5.5 7.5 3.9 4.1 B9
(0.78) (0.87) (0.02) (0.04) (0.19) (0.20) (0.22) (0.30) (0.22) (0.30) (0.15) (0.16)
SRP120L 24.9 27.1 0.6 1.0 4.9 5.2 5.5 7.5 10.5 12.5 3.9 4.1 B9
(0.98) (1.07) (0.02) (0.04) (0.19) (0.20) (0.22) (0.30) (0.41) (0.49) (0.15) (0.16)
SRP120S 19.9 22.1 0.6 1.0 4.9 5.2 5.5 7.5 5.5 7.5 3.9 4.1 B16
(0.78) (0.87) (0.02) (0.04) (0.19) (0.20) (0.22) (0.30) (0.22) (0.30) (0.15) (0.16)
SRP175 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B9
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
SRP175L 29.9 32.1 0.6 1.0 4.9 5.2 5.5 7.5 10.5 12.5 3.9 4.1 B9
(1.18) (1.26) (0.02) (0.04) (0.19) (0.20) (0.22) (0.30) (0.41) (0.49) (0.15) (0.16)
SRP175S 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B16
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
SRP175SS 20.9 23.1 0.6 1.0 4.9 5.2 4.1 5.5 4.1 5.5 3.9 4.1 B17
(0.82) (0.91) (0.02) (0.04) (0.19) (0.20) (0.16) (0.22) (0.16) (0.22) (0.15) (0.16)
SRP200 21.3 23.4 0.5 1.1 10.2 11.0 5.0 7.6 5.0 7.6 4.8 5.4 B9
(0.84) (0.92) (0.02) (0.04) (0.40) (0.43) (0.20) (0.30) (0.20) (0.30) (0.19) (0.21)
SRP350 28.4 31.8 0.5 1.1 13.0 13.5 6.3 8.9 6.3 8.9 6.0 6.6 B9
(1.12) (1.25) (0.02) (0.04) (0.53) (0.51) (0.25) (0.35) (0.25) (0.35) (0.24) (0.26)
SRP420 30.6 32.4 0.5 1.1 12.9 13.6 5.0 7.5 5.0 7.5 6.0 6.7 B9
(1.20) (1.28) (0.02) (0.04) (0.51) (0.54) (0.20) (0.30) (0.20) (0.30) (0.24) (0.26)
TAC
TAC170-09 16.5 17.5 0.9 9.5 10.5 9.4 10.0 5.0 5.2 0.8 1.2 B12
(0.65) (0.69) (0.036) (0.37) (0.42) (0.37) (0.40) (0.19) (0.21) (0.03) (0.05)
TAC210 16.5 17.5 0.9 9.5 10.5 9.4 10.0 5.0 5.2 0.8 1.2 B12
(0.65) (0.69) (0.036) (0.37) (0.42) (0.37) (0.40) (0.19) (0.21) (0.03) (0.05)
4
274 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
VLR (data at 25°C)
A=VLR170
B=VLR175
C= VLR230
Figures B19–B25. Typical Time-to-trip Curves at 20˚C for Strap Battery Devices
B
A
B
A
100
10
0.1
0.01
0.001
110 100
Fault Current (A)
Time-to-trip (s)
1
C
C
Figure B19
VLP (data at 25°C)
A=VLP210
B=VLP220
C= VLP270
B
A
B
A
100
10
0.1
0.01
0.001
110 100
Fault Current (A)
Time-to-trip (s)
1
C
C
Figure B20
1
100
10
1
0.1
0.01
0.001 10
Fault Current (A)
Time-to-trip (s)
100
E
B
C
D
A
A
B
C
D
E
Figure B21
VTP (data at 25°C)
A=VTP170
B=VTP175
C= VTP200
D= VTP210G
E=VTP240
Strap Battery
LR4
A=LR4-170U
B=LR4-190
C= LR4-260
D= LR4-380
E=LR4-450
F=LR4-550
G= LR4-600
H= LR4-730
I=LR4-900
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 275
4
Figures B19–B25. Typical Time-to-trip Curves at 20˚C for Strap Battery Devices continued
1
100
10
1
0.1
0.01 10
Fault Current (A)
Typical time-to-trip (s)
100
BC
D
E
F
G
H
A
BC
D
E
F
GH
A
I
I
Figure B23
EFG
D
C
AB
EFG
D
C
AB
1
100
10
1
0.1
0.01
0.001 10
Fault Current (A)
Time-to-trip (s)
100
Figure B22
LTP
A=LTP070
B=LTP100
C= LTP180
D= LTP190
E=LTP260
F=LTP300
G= LTP340
276 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
1
100
10
1
0.1
0.01 10
Fault Current (A)
Typical time-to-trip (s)
100
E
D
C
AB
E
D
C
AB
Figure B24
100
10
1
0.1
0.01
0.001
110 100
A
A
B
B
C
C
D
D
Fault Current (A)
Typical time-to-trip (s)
Figure B25
TAC & miniSMDE
A=TAC100-09
B=TAC170-09
C= TAC210
D= miniSMDE190
SRP
A=SRP120
B=SRP175
C= SRP200
D= SRP350
E=SRP420
Figures B19–B25. Typical Time-to-trip Curves at 20˚C for Strap Battery Devices continued
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 277
4
Strap Battery
Table B5. Physical Characteristics and Environmental Specifications for Strap Battery Devices
VLR
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel
Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5%
60°C, 1000 hours ±20%
Humidity aging 60°C/95% RH, 1000 hours ±30%
Thermal shock 85°C, -40°C (10 times) ±5%
Vibration MIL-STD-883D, Method 2026 No change
VLP and VTP
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel
Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5%
60°C, 1000 hours ±10%
Humidity aging 60°C/95% RH, 1000 hours ±10%
Thermal shock 85°C, -40°C (10 times) ±5%
Vibration MIL-STD-883D, Method 2026 No change
LTP
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel
Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10%
Humidity aging 85°C/85% RH, 7 days ±15%
Vibration MIL-STD-883C, Test Condition A No change
LR4
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel
Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10%
Humidity aging 85°C/85% RH, 7 days ±5%
Vibration MIL-STD-883D, Method 2026 No change
4
278 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
Table B5. Physical Characteristics and Environmental Specifications for Strap Battery Devices continued
SRP
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel
Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10%
Humidity aging 85°C/85% RH, 7 days ±5%
Vibration MIL-STD-883C, Test Condition A No change
TAC
Physical Characteristics
Lead material 0.15mm nominal thickness, nickel-plated steel
Molding material liquid crystal polymer
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10%
Humidity aging 85°C/85% RH, 7 days ±15%
Vibration MIL-STD-883D, Method 2026 No change
miniSMDE
Physical Characteristics
Termination pad materials Solder-plated copper
Termination pad solderability Meets EIA specification RS186-9E, ANSI/J-STD-002 Category 3
Environmental Specifications
Test Conditions Resistance Change
Passive aging 60°C, 1000 hours ±5% typical
85°C, 1000 hours ±5% typical
Humidity aging 85°C/85% RH, 100 days ±15% typical
Thermal shock 85°C, -40°C (20 times) -33% typical
125°C, -55°C (10 times) -33% typical
Vibration MIL-STD-883D, Method 2026 No change
Reflow conditions 260°C for 10-20 seconds Less than R1 MAX
Tape and reel specifications Per EIA 481-1 N/A
Note: Storage conditions: 40°C max., 70% RH max.; devices should remain in original sealed bags prior to use. Devices may not meet specified values if these
storage conditions are exceeded.
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 279
4
Strap Battery
Table B6. Packaging and Marking Information/Agency Recognition for Strap Battery Devices
Bag Tape & Reel Standard Part Agency
Part Number Quantity Quantity Package Marking Recognition
85°C Typical Activation—VLR
VLR170 1,000 10,000 R17 UL, CSA,TÜV
VLR170U 1,000 10,000 UL, CSA,TÜV
VLR175 1,000 10,000 R1X UL
VLR175L 1,000 10,000 R1X UL
VLR230 1,000 10,000 R23 UL, CSA,TÜV
VLR230S 1,000 10,000 R23 UL, CSA,TÜV
VLR230SU 1,000 10,000 UL, CSA,TÜV
VLR230U 1,000 10,000 UL, CSA,TÜV
90°C Typical Activation—VLP
VLP210 1,000 10,000 W21 UL, CSA, TÜV
VLP220 1,000 10,000 W22 UL, CSA, TÜV
VLP270 1,000 10,000 W27 UL, CSA, TÜV
90°C Typical Activation—VTP
VTP110 1,000 10,000 UL, CSA, TÜV
VTP170 1,000 10,000 V17 UL, CSA, TÜV
VTP170SS 1,000 10,000 V17 UL, CSA, TÜV
VTP170X 1,000 10,000 V17 UL, CSA, TÜV
VTP170XS 1,000 10,000 V17 UL, CSA, TÜV
VTP175 1,000 10,000 V1X UL, CSA, TÜV
VTP175U 1,000 10,000 UL, CSA, TÜV
VTP175L 1,000 10,000 V1X UL, CSA, TÜV
VTP200G 1,000 10,000 V20 UL, CSA, TÜV
VTP200U 1,000 10,000 UL, CSA, TÜV
VTP210G 1,000 10,000 V21 UL, CSA, TÜV
VTP210G-2 5,000 25,000 V21 UL, CSA, TÜV
VTP210L 1,000 10,000 V21 UL, CSA, TÜV
VTP210L-2 5,000 25,000 V21 UL, CSA, TÜV
VTP210S 1,000 10,000 V21 UL, CSA, TÜV
VTP210S-2 5,000 25,000 V21 UL, CSA, TÜV
VTP210SL 1,000 10,000 V21 UL, CSA, TÜV
VTP210SL-2 4,000 20,000 V21 UL, CSA, TÜV
VTP210SL-19.2/5.8 1,000 10,000 V21 UL, CSA, TÜV
VTP210SL-19.2/5.8-2 4,000 20,000 V21 UL, CSA, TÜV
VTP210SS 1,000 10,000 V21 UL, CSA, TÜV
VTP210ULD 1,000 10,000 UL, CSA, TÜV
VTP240 1,000 10,000 V24 UL, CSA, TÜV
110°C Typical Activation—LTP, TAC, miniSMDE
LTP070 2,000 10,000 L07 UL, CSA, TÜV
LTP070S 2,000 10,000 L07 UL, CSA, TÜV
LTP100 2,000 10,000 L10 UL, CSA, TÜV
LTP100S 2,000 10,000 L10 UL, CSA, TÜV
LTP100S-2 4,000 20,000 L10 UL, CSA, TÜV
LTP100SL 2,000 40,000 L10 UL, CSA, TÜV
LTP100SL-2 2,000 10,000 L10 UL, CSA, TÜV
LTP100SS 2,000 10,000 L10 UL, CSA, TÜV
LTP180 2,000 10,000 L18 UL, CSA, TÜV
LTP180L 500 10,000 L18 UL, CSA, TÜV
LTP180L-2 2,000 10,000 L18 UL, CSA, TÜV
LTP180S 2,000 10,000 L18 UL, CSA, TÜV
LTP180S-2 2,000 10,000 L18 UL, CSA, TÜV
LTP190 500 10,000 L19 UL, CSA, TÜV
4
Table B6. Packaging and Marking Information/Agency Recognition for Strap Battery Devices continued
Bag Tape & Reel Standard Part Agency
Part Number Quantity Quantity Package Marking Recognition
110°C Typical Activation—LTP, TAC, miniSMDE, continued
LTP260 1,000 10,000 L26 UL, CSA, TÜV
LTP260-2 2,000 10,000 L26 UL, CSA, TÜV
LTP300 500 10,000 L30 UL, CSA, TÜV
LTP340 500 10,000 L34 UL, CSA, TÜV
miniSMDE190-2 5,000 5,000 19 UL, CSA, TÜV
TAC100-09 2,000 10,000 Blue* UL
120°C Typical Activation—LR4, SRP, TAC
LR4-170U 2,000 10,000 NA UL, CSA, TÜV
LR4-190 2,000 10,000 E19 UL, CSA, TÜV
LR4-190S 2,000 10,000 E19 UL, CSA, TÜV
LR4-190S-2 4,000 20,000 E19 UL, CSA, TÜV
LR4-260 1,000 10,000 E26 UL, CSA, TÜV
LR4-260S 1,000 10,000 E26 UL, CSA, TÜV
LR4-380 1,000 10,000 E38 UL, CSA, TÜV
LR4-450 1,000 10,000 E45 UL, CSA, TÜV
LR4-550 1,000 10,000 E55 UL, CSA, TÜV
LR4-600 1,000 10,000 E60 UL, CSA, TÜV
LR4-730 1,000 10,000 E73 UL, CSA, TÜV
LR4-900 500 10,000 E90 UL; (CSA and TÜV pending)
SRP120 2,000 10,000 120 UL, CSA, TÜV
SRP120L 1,000 10,000 120 UL, CSA, TÜV
SRP120S 2,000 10,000 120 UL, CSA, TÜV
SRP175 2,000 10,000 175 UL, CSA, TÜV
SRP175-2 2,000 10,000 175 UL, CSA, TÜV
SRP175L 1,000 10,000 175 UL, CSA, TÜV
SRP175S 2,000 10,000 175 UL, CSA, TÜV
SRP175SS 2,000 10,000 175 UL, CSA, TÜV
SRP200 500 10,000 200 UL, CSA, TÜV
SRP200-2 4,000 20,000 200 UL, CSA, TÜV
SRP350 500 10,000 350 UL, CSA, TÜV
SRP420 500 10,000 420 UL, CSA, TÜV
TAC170-09 2,000 10,000 Black* UL, CSA
TAC210 2,000 10,000 White* UL, CSA, TÜV
TAC210-2 4,000 20,000 White* UL, CSA, TÜV
*Color indicated is mold ring material color.
280 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
Agency Recognition for Strap Battery Devices
UL File # E74889
CSA File #78165C
TÜV Certificate number available on request
Note: Tape and reel packaging not available for all devices. Contact your local Raychem Circuit Protection representative for additional information.
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 281
4
Strap Battery
Blank = Bulk
2 = Tape and reel packaging
Modifier
G = Global design (standard product)
L = Long lead or leads
S = Slit lead
SS = Both leads slit
X = Rotated chip
U = Untaped
Hold current indicator
Product series
Blank = Bulk
2 = Tape and reel packaging
19.2/5.8 = Maximum length of leads (mm)
Modifier
G = Global design (standard product)
L = Long lead or leads
S = Slit lead
SS = Both leads slit
X = Rotated chip
U = Untaped
Hold current indicator
Product series
Blank = Bulk
2 = Tape and reel packaging
09 = Maximum thickness indicator
Hold current indicator
Product series
LTP 190 SS -2
TAC 210
-2
-09
VTP 210 SL 19.2/5.8 -2
Part Numbering System for Strap Battery Devices
282 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
a
W2
W1
n (hub dia.)
Cover tape
Embossed cavity
Carrier tape
Figure B27. Reel Dimensions for TAC Series
A
EOG
BFC
D
Figure B26. Taped Component Dimensions for TAC Series
Table B7. Tape and Reel Specifications for TAC Series Devices (in Millimeters)
Description Mark Dimensions (mm) Tolerance (mm)
Carrier tape width A 24.0 ±0.5
Sprocket hole pitch F 4.0 ±0.10
Embossed cavity pitch D 12.0 ±0.10
Ordinate to embossed cavity center E 2.0 ±0.2
Embossed cavity length (inside) 17.5
Embossed cavity width (inside) 10.4
Embossed cavity length (outside) 17.6
Sprocket hole diameter G 1.55 ±0.05
Abscissa to embossed cavity center 11.5 ±0.15
Sprocket hole location C 1.75 ±0.15
Carrier tape thickness 0.3 ±0.05
Cover tape thickness 0.055
Embossed cavity depth (inside) 1.35 ±0.1
Leader min. 800
Trailer min. 800
Reel diameter a 420 ±2
Hub diameter n 80 ±1
Reel width measured at inside hub W124.4 +2, –0
Reel width measured at outside hub W230.4 +3, –1
Strap Battery
Raychem Circuit Protection PolySwitch Strap Battery Resettable Devices 283
4
Latest Information
Please visit us at www.circuitprotection.com or contact your local representative for the latest information.
The information in this Databook may contain some preliminary information. Raychem Circuit Protection, a
divsion of Tyco Electronics, reserves the right to change any of the specifications without notice. In addi-
tion, Tyco Electronics reserves the right to make changeswithout notification to Buyerto materials or
processing that do not affect compliance with any applicable specification.
Figure B28. Typical Taped Component Layout for Strap Battery Products
Note: Contact your local Raychem Circuit Protection representative for dimensions and availabilty.
Installation Guidelines for the Strap Family
Polymeric PTC devices operate by thermal expansion of the conductive polymer. If devices are placed under
pressure or installed in spaces that would prevent thermal expansion, they may not properly protect against
fault conditions. Designs must be selected in such a manner that adequate space is maintained over the life
of the product.
Twisting, bending, or placing the PPTC device in tension will decrease the ability of the device to protect
against electrical faults. No residual force should remain on device after installation. Mechanical damage
to PPTC chip may affect device performance and should be avoided.
Chemical contamination of PPTC devices should be avoided. Certain greases, solvents, hydraulic fluids,
fuels, industrial cleaning agents, volatile components of adhesives, silicones, and electrolytes can have an
adverse effect on device performance.
PPTC strap devices are designed to be resistance welded to battery cells or to pack interconnect straps,
yet some precautions must be taken when doing so. In order for the PPTC device to exhibit its specified
performance, weld placement should be a minimum of 2mm from the edge of the PPTC chip, weld splatter
must not touch the PPTC chip, and welding conditions must not heat the PPTC device above its maximum
operating temperature.
PPTC strap devices are not designed for applications where reflow onto flex circuits or rigid circuit boards
is required.
The polyester tape on PolySwitch strap devices is intended for marking and indentification purposes only,
not for electrical insulation.
284 PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection
4
Operation beyond the maximum ratings or improper use may result in device damage and possible elec-
trical arcing and flame.
The devices are intended for protection against occasional overcurrent or overtemperature fault conditions
and should not be used when repeated fault conditions or prolonged trip events are anticipated.
Contamination of the PPTC material with certain silicon based oils or some aggressive solvents can
adversely impact the performance of the devices.
Device performance can be impacted negatively if devices are handled in a manner inconsistent with rec-
ommendated electronic, thermal, and mechanical procedures for electronic components.
Operation in circuit with a large inductance can generate a circuit voltage (L di/dt) above the rated voltage
of the PolySwitch resettable device.
WARNING: