Your number one name for EMC
FN 2000 SERIES
single-phase
chassis-
mounting filters
SCHAFFNER
Schaffner’s worldwide sales,
distribution and production network
HEADQUARTERS
Schaffner EMV AG
Nordstrasse 11
CH-4542 Luterbach
Switzerland
Tel: (032) 6816 626
Fax: (032) 6816 641
EUROLOGISTICS CENTER
Schaffner
1A, avenue de Suisse
F-68311 Illzach
France
Tel: (03) 89 31 04 00
Fax: (03) 89 31 04 01
FACTORIES
Schaffner EMV AG
Nordstrasse 11
CH-4542 Luterbach
Switzerland
Tel: (032) 6816 626
Fax: (032) 6816 641
Schaffner Ltd
National Technological Park
Castletroy
Limerick
Ireland
Tel: (061) 332233
Fax: (061) 332584
Schaffner EMC Co Ltd
67 Moo 4 Tambol Ban Klang
Amphur Muang PO Box 14
Lamphun 51000
Thailand
Tel: (053) 581 104
Fax: (053) 581 019
SALES SUBSIDIARIES
Schaffner Beijing Liaison Office
Room 911, Bright China Chang An Building
No. 7 Jianguomennei Dajie
Beijing 100005
China
Tel: (10) 6510 1761
Fax: (10) 6510 1763
Schaffner SA
43 rue Michel Carré
F-95103 Argenteuil
France
Tel: (01) 34 34 30 60
Fax: (01) 39 47 02 28
Rhone Alpes
F-38560 Champ sur Drac
Tel: (04) 76 68 64 00
Fax: (04) 76 68 63 70
Rennes
F-35510 Cesson-Sévigné
Tel: (02) 99 22 70 00
Fax: (02) 99 22 70 07
Schaffner EMV GmbH
Schoemperlenstrasse 12B
D-76185 Karlsruhe
Germany
Tel: (0721) 56 910
Fax: (0721) 56 9110
Northern Germany
D-59581 Warstein
Tel: (02902) 97 56 10
Fax: (02902) 97 56 80
Schaffner EMC Srl
Via Galileo Galilei, 47
I-20092 Cinisello Balsamo (MI)
Italy
Tel: (02) 66 04 30 45
Fax: (02) 61 23 943
Schaffner EMC KK
2-31-6 Kamiuma
Setagaya-Ku
Tokyo 154-0011
Japan
Tel: (03) 3418 5822
Fax: (03) 3418 3013
Schaffner EMC Pte Ltd
1200 Depot Road 06–01
Singapore 109675
Singapore
Tel: 377 3283
Fax: 377 3281
Schaffner EMC AB
Turebergstorg 1,6
S-19186 Sollentuna
Sweden
Tel: (08) 921121
Fax: (08) 929690
Schaffner Altrac AG
Mühlehaldenstrasse 6
CH-8953 Dietikon
Switzerland
Tel: (01) 744 61 11
Fax: (01) 744 61 61
Schaffner EMC Ltd
Ashville Way
Molly Millar’s Lane
Wokingham
Berks RG41 2PL
UK
Tel: (0118) 9770070
Fax: (0118) 9792969
Schaffner EMC Inc
9-B Fadem Road
Springfield, NJ 07081
USA
Toll free: (800) 367 5566
Tel: (973) 379 7778
Fax: (973) 379 1151
West Coast
Irvine, CA 92718
Tel: (949) 457 9400
Fax: (949) 457 9510
DISTRIBUTORS
Austria
Eurodis Electronics GmbH Tel: 1 610 620
Belgium
SEI Belgium Tel: 456 0747
Czech Republic
Energo Praga Ltd. Tel: 2 6111 2665
Denmark
Avnet Nortec A/S Tel: 44 88 08 00
Finland
Electro Ferrum Oy Tel: 19 326 616
Netherlands
SEI Benelux B.V. Tel: 76 57 22 500
Norway
Avnet Nortec A/S Tel: 66 77 36 00
Poland
Astat Sp. Tel: 61 8488 871
Spain
Selco S.A. Tel: 91 637 1011
Sweden
Avnet Nortec AB Tel: 8 629 1400
Turkey
Artest Elektronik Tel: 216 478 1757
Australia
Westek Industrial Products Pty Ltd.
Tel: 3 9369 8802
Brasil
Teknikao Ind e Com Ltda Tel: 11 834 5544
Hong Kong
Denetron (HK) Ltd. Tel: 2 707 9132
India
Vishal Agencies Tel: 40 711 2079
Israel
RDT Components Ltd. Tel: 3 645 0707
Japan
Nemic Lambda K.K. Tel: 3 3447 4411
SSR Engineering Co. Ltd. Tel: 3 3493 6613
Unidux Inc Tel: 422 32 4500
Korea
Power EMC TEK Tel: 2 501 5852
New Zealand
MHS Technologies Ltd. Tel: 4 567 7016
Republic of South Africa
Electronic Building Elements Tel: 12 803 7680
Taiwan
Bandtek Int. Co. Ltd. Tel: 2 2747 3733
SCHAFFNER
Compact single-phase filters for
general-purpose applications
Schaffner’s FN 2000 series single-phase filters provide an extremely
cost-effective solution for a wide range of general-purpose filtering
requirements. Employing high performance magnetic and capacitive
components, the filters have a very compact form factor, making them
particularly suitable for applications where space is at a premium. All FN
2000 Series filters are provided in chassis-mounting metal housings, with
a choice of fast-on, wire or screw feed-through connectors for ease of
system integration. Designed for operation at up to 250VAC, the filters
can handle supply frequencies from DC to 400Hz.
This filter range is available in many different standard forms in addition
to those shown by the electrical schematics in this shortform catalogue.
The multi-stage filters, for example, can be supplied with capacitors
connected to the load side, in order to present the best impedance
mismatch between equipment and filter. Further information can be
obtained from our headquarters in Switzerland, or any subsidiary.
Family
FN 2010
FN 2020
FN 2060
FN 2070
FN 2080
0 5 10 15 20 25 30
0 100
standard
Current rating (A) Attenuation
middle high very high
Rapid selection Using the current rating and attenuation performance indicators, this table allows you to quickly identify a filter
which is potentially suitable for your application, for subsequent detailed investigation on the pages shown.
1
Mechanical data for FN 20X0 . . . . . . . 12
FN 2010 electrical specification . . . . . . 2
FN 2020 electrical specification . . . . . . 4
FN 2060 electrical specification . . . . . . 6
FN 2070 electrical specification . . . . . . 8
FN 2080 electrical specification . . . . .10
CONTENTS
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2010-10/06 is a 10A
filter with fast-on connections.
See Mechanical Data on pages 12 - 13 for
full details of housings and connections.
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
Current ratings
A at 40°C (25°)
FN 2010-1 /??
FN 2010-3 /??
FN 2010-6 /??
FN 2010-10 /??
FN 2010-12 /??
FN 2010-16 /??
FN 2010-20 /??
FN 2010-30 /??
Filter
/06
/06
/06
/06
/06
/06
/06
-
/07
/07
/07
/07
/07
/07
-
-
-
-
-
-
-
-
/08
/08
Connections
F3
F3
F3
F2
F2
H2
K1
P
Housing
65
65
65
85
85
140
210
470
Weight
g
800 000
800 000
800 000
MTBF
Per Mil-HB-217F at 40ºC 230V
hours
2000 1700
2500 1700
2500 1700
Filter type
0.4*
0.002
0.040
Maximum
leakage
mA/phase
250 50/60
250 50/60
250 50/60
Maximum operat-
ing voltage
VAC Hz
Hipot test voltage
PNE PN
VAC VDC
Operating fre-
quency
Hz
DC to 400
DC to 400
DC to 400
* 1mA for 30A version
Additional specifications and options
Approvals
V
E
D
FN 2010
12 0.1 4.7 1
2.5 0.1 4.7 1
1 0.1 4.7 1
0.8 0.1 4.7 1
0.7 0.1 4.7 1
0.65 0.1 4.7 1
0.6 0.1 4.7 1
0.67 0.47 10 1
Inductance Capacitance Resistance
LCxCyR
mH µFnF M
The FN 2010 family is designed to provide an economic solution for a
wide variety of general-purpose filtering requirements. Available in 15
standard versions, with current ratings from 1 to 30A and a choice of
three different connector styles, individual application requirements are
easily and economically matched.
current ratings from 1 to 30A
general-purpose filtering performance
three choices of connector style
optional medical versions (B types)
optional safety versions (A types)
General-purpose filter
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
EN 133200
2
SCHAFFNER
Insertion loss
Per CISPR 17; A = 50/50sym, B = 50/50asym, C = 0.1/100sym, D = 100/0.1sym
1A types
10A types (12A*)
3A types 6A types
Electrical schematics
16A types 20A types
30A types
E
Cx R L
FN 2010
LINE
LOAD
Cy Cy
N
P
N'
P'
See tables for component values.
3
* attenuation performance of the 12A version is similar to the 10A component.
A
BC
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
A
B
C
D
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2020-10/06 is a 10A
filter with fast-on connections.
See Mechanical Data on pages 12 -13 for
full details of housings and connections.
SCHAFFNER
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
Current ratings
A at 40°C (25°)
FN 2020-1 /??
FN 2020-3 /??
FN 2020-6 /??
FN 2020-10 /??
FN 2020-12 /??
FN 2020-16 /??
FN 2020-20 /??
FN 2020-30 /??
Filter
/06
/06
/06
/06
/06
/06
/06
-
/07
/07
/07
/07
/07
/07
-
-
-
-
-
-
-
-
/08
/08
Connections
F2
F2
F2
F2
F2
H2
K1
P
Housing
80
80
80
85
85
140
210
470
Weight
g
600 000
600 000
600 000
MTBF
Per Mil-HB-217F at 40ºC 230V
hours
2000 1700
2500 1700
2500 1700
Filter type
0.4*
0.002
0.040
Maximum
leakage
mA/phase
250 50/60
250 50/60
250 50/60
Maximum
operating voltage
VAC Hz
Hipot test voltage
PNE PN
VAC VDC
Operating
frequency
Hz
DC to 400
DC to 400
DC to 400
* 1mA for 30A version
Additional specifications and options
Approvals
V
E
D
FN 2020
12 0.15 4.7 1
2.5 0.15 4.7 1
1 0.15 4.7 1
0.8 0.15 4.7 1
0.7 0.15 4.7 1
0.65 0.15 4.7 1
0.6 0.15 4.7 1
0.67 0.47 10 0.47
Inductance Capacitance Resistance
LCxCyR
mH µFnF M
General-purpose filter
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
4
Similar to FN 2010, but with additional phase-to-neutral capacitance for
improved differential mode performance, the FN 2020 family is designed
to provide an economic solution for many general-purpose filtering
requirements. Available in 15 standard versions, with current ratings from
1 to 30A, individual application requirements are easily and economically
matched.
current ratings from 1 to 30A
high differential mode attenuation
three choices of connector style
optional medical versions (B types)
optional safety versions (A types)
EN 133200
Insertion loss
Per CISPR 17; A = 50/50sym, B = 50/50asym, C = 0.1/100sym, D = 100/0.1sym
1A types
30A types
3A types 6A types
Electrical schematics
16A types 20A types
N
L
Cx Cx
R
FN 2020
LINE
LOAD
Cy Cy
E
P
N'
P'
See tables for component values.
5
10A types (12A*)
* attenuation performance of the 12A version is similar to the 10A component.
A
B
C
D
A
BC
D
A
B
C
D
A
BC
D
A
B
C
D
A
B
C
D
A
B
C
D
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2060-10/08 is a 10A
filter with screw feed-throngh connections.
See Mechanical Data on pages 12 - 13 for
full details of housings and connections.
SCHAFFNER
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
Current ratings
A at 40°C (25°)
FN 2060-1 /??
FN 2060-3 /??
FN 2060-6 /??
FN 2060-10 /??
FN 2060-12 /??
FN 2060-16 /??
FN 2060-20 /??
FN 2060-30 /??
Filter
/06
/06
/06
/06
/06
/06
/06
-
/07
/07
/07
/07
/07
/07
-
-
-
-
-
-
-
/08
/08
/08
Connections
H2
H2
H2
K1
K1
K2
P
L2
Housing
120
120
120
190
190
260
480
950
Weight
g
450 000
450 000
450 000
MTBF
Per Mil-HB-217F at 40ºC 230V
hours
2000 1700
2500 1700
2500 1700
Filter type
0.4*
0.002
0.040
Maximum
leakage
mA/phase
250 50/60
250 50/60
250 50/60
Maximum
operating voltage
VAC Hz
Hipot test voltage
PNE PN
VAC VDC
Operating
frequency
Hz
DC to 400
DC to 400
DC to 400
* 1mA for 30A version
Additional specifications and options
Approvals
V
E
D
FN 2060
12 0.22 4.7 1
2.5 0.22 4.7 1
0.97 0.22 4.7 1
0.8 0.47 4.7 0.47
0.58 0.47 4.7 0.47
0.65 0.33 4.7 1
0.6 1 4.7 0.22
0.6 1 10 0.22
Inductance Capacitance Resistance
LCxCyR
mH µFnF M
Similar to FN 2020, but with additional inductance stages for higher
common mode attenuation, the FN 2060 family is designed to provide an
economic solution for many general-purpose filtering requirements.
Available in 16 standard versions, with current ratings from 1 to 30A,
individual application requirements are easily and economically matched.
current ratings from 1 to 30A
high differential and common mode attenuation
three choices of connector
optional medical versions (B types)
optional safety versions (A types)
Multi-stage general-purpose filter
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
6
EN 133200
Insertion loss
Per CISPR 17; A = 50/50sym, B = 50/50asym, C = 0.1/100sym, D = 100/0.1sym
1A types
30A types
3A types 6A types
Electrical schematics
16A types 20A types
N
LL
Cx
Cx R
FN 2060
LINE
LOAD
Cy Cy
E
P
N'
P'
See tables for component values.
7
10A types (12A*)
* attenuation performance of the 12A version is similar to the 10A component.
B
0
0
0
0
0
0
0
0
0
0
A
B
C
DA
B
C
D
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
A
BC
D
dB
70
60
50
40
30
20
10
0
-10
-2010k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-2010k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-2010k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2070-10/06 is a 10A
filter with fast-on connections.
See Mechanical Data on pages 12 - 13 for
full details of housings and connections.
SCHAFFNER
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
Current ratings
A at 40°C (25°)
FN 2070-1 /??
FN 2070-3 /??
FN 2070-6 /??
FN 2070-10 /??
FN 2070-12 /??
FN 2070-16 /??
Filter
/06
/06
/06
/06
/06
/06
/07
/07
/07
/07
/07
/07
-
-
-
-
-
/08
Connections
K1
K2
P
Q
Q
L2
Housing
190
250
450
730
730
1000
Weight
g
400 000
400 000
400 000
MTBF
Per Mil-HB-217F at 40ºC 230V
hours
2000 1700
2500 1700
2500 1700
Filter type
0.4
0.002
0.040
Maximum
leakage
mA/phase
250 50/60
250 50/60
250 50/60
Maximum
operating voltage
VAC Hz
Hipot test voltage
PNE PN
VAC VDC
Operating
frequency
Hz
DC to 400
DC to 400
DC to 400
Additional specifications and options
Approvals
V
E
D
FN 2070
22 0.33 4.7 1
9.8 0.47 4.7 0.47
7.8 1 4.7 0.22
4.5 1 4.7 0.22
3.25 1 4.7 0.22
2.8 1 4.7 0.22
Inductance Capacitance Resistance
LCxCyR
mH µFnF M
Similar to FN 2060, but with even higher inductance and capacitance
values for excellent differential and common mode attenuation -
especially at high frequencies - the FN 2070 family is designed to provide
a cost-effective solution for broadband filtering requirements. Available in
13 standard versions, with current ratings from 1 to 16A, the filters are
ideal for use with precision instrumentation, switched-mode power
supplies and motor drives.
current ratings from 1 to 16A
very high differential and common mode attenuation
good high-frequency attenuation
three choices of connector
optional medical versions (B types)
optional safety versions (A types)
Multi-stage performance filter
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
8
EN 133200
Insertion loss
Per CISPR 17; A = 50/50sym, B = 50/50asym, C = 0.1/100sym, D = 100/0.1sym
1A types 3A types 6A types
16A types
9
10A types (12A*)
* attenuation performance of the 12A version is similar to the 10A component.
Electrical schematics
N
LL
Cx
Cx R
FN 2070
LINE
LOAD
Cy Cy
E
P
N'
P'
See tables for component values.
A
BC
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2080-10/06 is a 10A
filter with fast-on connections.
See Mechanical Data on pages 12 -13 for
full details of housings and connections.
SCHAFFNER
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
Current ratings
A at 40°C (25°)
FN 2080-1 /??
FN 2080-3 /??
FN 2080-6 /??
FN 2080-10 /??
FN 2080-12 /??
FN 2080-16 /??
Filter Connections
K1
K2
P
Q
Q
L2
Housing
200
270
470
750
750
1020
Weight
g
350 000
350 000
350 000
MTBF
Per Mil-HB-217F at 40ºC 230V
hours
2000 1700
2500 1700
2500 1700
Filter type
0.4
0.002
0.040
Maximum
leakage
mA/phase
250 50/60
250 50/60
250 50/60
Maximum
operating voltage
VAC Hz
Hipot test voltage
PNE PN
VAC VDC
Operating
frequency
Hz
DC to 400
DC to 400
DC to 400
Additional specifications and options
Approvals
V
E
D
FN 2080
22 0.49 0.33 4.7 1
9.8 0.16 0.47 4.7 0.47
7.8 0.11 1 4.7 0.22
4.5 0.06 1 4.7 0.22
3.25 0.05 1 4.7 0.22
2.8 0.043 1 4.7 0.22
Inductance Capacitance Resistance
LL1 Cx Cy R
mH µFnF M
Similar to FN 2070, but employing independent differential mode chokes
rather than common mode chokes in the second stage, the FN 2080
family of filters provides excellent broadband attenuation, including low
frequencies. Available in 13 standard versions, with current ratings from 1
to 16A, the filters are ideal for protecting against very high levels of
interference, such as in noisy power supplies.
current ratings from 1 to 16A
very high differential and common mode attenuation
good low-frequency attenuation
three choices of connector
optional medical versions (B types)
optional safety versions (A types)
Multi-stage high-performance filter
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
10
/06
/06
/06
/06
/06
/06
/07
/07
/07
/07
/07
/07
-
-
-
-
-
/08
EN 133200
Insertion loss
Per CISPR 17; A = 50/50sym, B = 50/50asym, C = 0.1/100sym, D = 100/0.1sym
1A types 3A types 6A types
Electrical schematics
16A types
N
L1LCx
Cy Cy
R
FN 2080
LINE
LOAD
Cx
E
P
N'
P'
See tables for component values.
11
10A types (12A*)
* attenuation performance of the 12A version is similar to the 10A component.
A
B
C
D
A
B
C
D
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
B
0
0
0
0
0
0
0
0
0
0
A
B
C
D
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
dB
70
60
50
40
30
20
10
0
-10
-20 10k 100k 1M 10M
SCHAFFNER
Mechanical Data
12
64 ± 0.3 71 85
35 46.6 54
29.3 24.3 29.3 30.3 40.3
43.5 50.5 64.8
54 61 75
21 21 27
8.3§/9.3 10.8/8.3§12.3/8.3§
15.3 19.3 20.8/23.3 29.8
5.3 5.3
6.3 6.3
0.7 0.7
20.1/30.5§19.9/34.9§/21.411.4/34.9§
F2 F3 H2 K1 K2
All dimensions in mm; 1 inch = 25.4mm.
SIDE
TOP
Housings F2 and F3 Housings H2, K1 and K2
± 0.5
± 0.5
± 0.5
± 0.5
± 0.3
± 0.2
± 0.5
± 0.5
± 0.1
± 0.1
± 0.1
± 0.5
Tol.*
±mm
§with /07 connections with /08 connections
A
B
C
D
F
J
K
L
M
N
P
S
CK
J
M
N
L
F
B
D
F
A
D
P
L
P
KC
J
S
M
N
BA
Housing
style
* Measurements share this common
tolerance unless otherwise stated.
Mechanical Data
13
113.5 156 119 ± 0.5
57.5 85.5
45.4 ± 1.2 57.6
94
4.4
130.5 98.5
103 143 109
25 40
12.4/8.4§15.6/8.6§
32.4 5.3 4.4
67.4
0.9 1.2
66
51
15.5/38§
PQL2
All dimensions in mm; 1 inch = 25.4mm.
SIDE
TOP
Housing L2
Housings P and Q
±1
±1
±1
±1
± 0.3
± 0.2
± 0.5
± 0.5
± 0.1
± 0.1
± 0.1
± 0.3
± 0.2
± 0.5
Tol.*
±mm
§with /07 connections
A
B
C
D
F
J
K
L
M
N
P
Q
R
S
Housing
style
M
C
P
K
J
M
N
R
Q
L
F
B
D
F
AD
P
K
C
J
S
N
B
A
I/O connections
These are the standard types of input and
output connections available for Schaffner’s
range of filter families.
Schaffner can also produce filters with other
popular output connectors, or user-specific
interfaces, to custom order. Please call your
local sales office to discuss requirements.
Type /06
Industry-standard size fast-on which may
also be used as a solder lug, 6.3 x 0.8mm.
12.3
10.8
P/N E
Type /07
Insulated wire, stripped ready for solder-
ing. Wire gauge varies according to filter.
P/N/E
Type /08
M4 screw
P/N E
13.9
Current AWG Cu mm2
ratings number (approx)
1-3A 20 0.54
6-10A 18 0.83
12-16A 16 1.34
Dimensions in mm. 1 inch = 25.4mm
Cross reference list
AWG to copper area in mm2
* Measurements share this common
tolerance unless otherwise stated.
140 +5
-0
Schaffner EMV AG CH-4542 Luterbach, Switzerland
Tel: [+41] (32) 6816 626 Fax: [+41] (32) 6816 641 ww w.schaffner.com
690-407E Benteli Hallwag /January 1999
© 1995 Schaffner EMV. Specifications subject to change without
notice. All trademarks recognised.
Schaffner is an ISO-registered company. Its products are
designed and manufactured under the strict quality
requirements of the ISO 9001 standard.
Certified
ISO 9001
supplier
This document has been carefully checked. However, Schaffner
does not assume any liability for errors or inaccuracies.
SCHAFFNER