Amphenol Cable Glands and Cord Grips (R) 12-055 Amphenol Table of Contents Introduction Amphenol(R) Cable Glands Page Number 1 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30 8-9 EX-35 10-11 EX-40 12-13 EX-45 14-15 EE-RG 16-17 ATEX Approved Glands Featuring Elastometric Seals for Flat Cable EX-50 18-19 EX-55 20-21 ATEX Approved Barrier Glands EX-60 22-23 EX-65 24-25 EX-70 26-27 EX-75 Stopper Box 28-29 Industrial Glands CGA 30-31 CGSS 32-33 CGDS 34-35 CGU 36-37 Accessories ARAdaptors & Reducers 38-39 Nylon Adaptors & Reducers 40-41 Insulated Adaptors 42-43 Mushroom Head Stopping Plugs 44-45 Nylon Mushroom Head Stopping Plugs 46-47 Type A & Type B Stopping Plugs 48-49 Breather Drain 50-51 Locknuts, Earth Tags, etc. 52 Entry Thread Reference Tables 53 Ingress Protection, Gland Weight Data 54 (R) (R) 55 Cord Grip Specifications 56-57 DB/DBM Group 58-59 DBZ Group 60-61 DBL/DBZL Group 62-63 DBA Group 64-65 DBF Group, Flared Nipples 66-67 DBZP Series 68-69 Grommets 70-71 Accessories 72-73 Amphenol /Pyle Cord Grips Addtional Amphenol(R) Industrial Products Amphenol Sales Offices and Distributors Listing 74-75 76 For further information on your individual application requirements, contact: Amphenol Corporation Amphenol Industrial Operations 40-60 Delaware Avenue Sidney, New York 13838-1395 Phone: 607-563-5011 Fax: 607-563-5351 View and download or print Amphenol catalogs on-line at: www.amphenol-industrial.com Amphenol operates quality systems that are certified to ISO 9001:2000 by third party registrars. For product specific questions regarding RoHS compliance, consult Amphenol Industrial Operations, or call the RoHS Product Compliance and Technical Support line: 1-866-315-8559 Amphenol Industrial Operations Amphenol(R) Cable Glands and Cord Grips Amphenol Industrial offers more choices, more solutions, and more options than any other interconnect manufacturer in the world. In addition to the broadest range of connector solutions in the market, we also offer an extensive line of Explosion Proof and General Duty Cable Glands. We also carry a complete line of liquid tight strainrelief products in our Cord Grip line of performance cable seals. Our combination of Glands and Cord Grips makes Amphenol Industrial the one stop supplier for all your connector and cable sealing solutions. Cable Glands Amphenol Industrial Operations, the worldwide leader of explosion proof and hazardous environment interconnects, introduces our broad range of explosion proof and industrial cable glands. The new Cable Gland product line is designed toperform in the most demanding environments. Amphenol's complete line of EX Zone 1 and 2 rated cable glands offers our customers great flexibility. In addition, we have a complete line of general duty industrial application cable glands suitable for armored and unarmored cable. * SIRA/ATEX certified to Exd/Exe (Class I, Div. I) * CSA Approved * IP66/68; Deluge; NEMA rated products * Temperature Ranges from -40F to +180F * Brass and Stainless Steel available. Amphenol Cable Glands are RoHS Compliant. Cord Grips Whether you need a straight, 45, or 90 strain relief, Amphenol's family of cord Grips has you covered. Strong, lightweight aluminum components provide a long lasting, reliable liquid tight solution. Amphenol Industrial Cord Grips offer a complete line of strain relief options that include gland nuts, mechanical clamps and basketweave cable grips. UL and CSA listed, our Cord Grips have been put to the test for over 40 years. * Tapered rubber grommets and seal * Machined Components * Male and female threads available * Tapered conduit threads Amphenol Cord Grips are available with RoHS Compliant options. Please contact Amphenol Industrial Operations for information. 1 Amphenol Cable Glands and Cord Grips Amphenol Explosion Proof and Industrial Cable Glands This section will provide you with information on Amphenol's complete family of cable glands, and will assist you in determining which of our glands will satisfy your specific need. If you have further questions, please contact our factory or one of the Amphenol Industrial distributors listed in the back of this catalog. Amphenol Industrial Operations, the recognized leader in explosion proof and hazardous environment interconnects, offers a complete line of Industrial and Explosion Proof Glands. Whether part of an integrated connector solution, or as part of a bulkhead feed through, Amphenol has the solution you are looking for. Our product range includes general duty industrial cable glands meant to seal on unarmored cable, right up to our ATEX approved EX glands capable of protecting the most rugged cable in your zone rated applications. Our EX Approved Glands also provide a complete zone rated interconnect solution when used in conjunction with our ATEX approved Star-Line EX explosion proof connector series. For additional information on the Star-Line EX product, consult Amphenol catalog 12-054. Features & Benefits ATEX and CSA Certified: Approved to perform in the most hazardous environments. Variety of Styles: Cable glands available to accommodate any cable type. IP Ratings Included: Watertight seals allow for both indoor and outdoor applications. Machined Components made from brass and stainless steel. Complete Line of Accessories: Including locknuts, washers, and earth tags. Entry Thread Flexibility: Both metric and NPT threads available on most styles. Applications * Oil and Gas Exploration Equipment * Machine and Heavy Electronics * Pharmaceutical Manufacturing Facilities * Production Platforms * Chemical and Paint Manufacturing Facilities * Robotics and Welding Equipment * Process Control Equipment * Motors and Generators 2 Amphenol Cable Glands Cable Gland Selection Guide This table is designed to be a quick reference to the cable glands found in this publication. Gland Type Outer Seal Inner Seal Lead Option Armor Clamp Certification IP Rating Page Number ATEX/CSA Approved Glands with Elastomeric Seals EX-20 Exd/Exe Deluge, IP66, 68 NEMA, 4X 4 EX-25 Exd/Exe (Not CSA) IP66, IP67 6 EE-30 Exe IP66 8 (Not CSA) EX-35 Exd/Exe IP66 IP68 NEMA 4X 10 EX-40 x2 Exd/Exe IP66 IP68 NEMA 4X 12 EX-45 Exd/Exe IP66 IP68 NEMA 4X 14 EE-RG Exe IP66 IP68 16 ATEX/CSA Approved Glands with Elastomeric Seals for Flat Cable EX-50 Flat Cable Flat Cable Braid Exd/Exe IP66 18 EX-55 Flat Cable Exd/Exe IP68 20 ATEX Approved Compound Filled Barrier Glands EX-60 EX-65 Compound Exd Deluge, IP66, IP68 NEMA, 4X 22 Compound Compound Exd Deluge, IP66, IP68 24 NEMA, 4X EX-70 Compound Exd Deluge, IP66, IP68 26 NEMA, 4X EX-75 Compound Exd (stopper box) Deluge, IP66, IP68 28 NEMA, 4X Non Hazardous Industrial Glands CGA Industrial (BS6121) IP30 30 CGSB Industrial IP66 32 CGDS Industrial IP67 34 CGU Industrial IP66, IP66 36 www.amphenol-industrial.com 3 ATEX/CSA Approved Glands with Elastomeric Seals EX-20 EX-20 type glands provide a seal on the inner sheath, a seal on the outer sheath, an entry thread seal and a universal armor clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EX-20 glands can also be used to terminate unarmored or lead sheathed cables. EX-20 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection; IP66, 68 to 25 meters and is deluge resistant. An integral `O' ring entry thread seal is fitted to metric versions as standard. EXAMPLE PART NUMBER EX-20 W X Y R YY ZZ [W] - [X] [Y] [R] [YY] [ZZ] Gland material (B = Brass / S = Stainless Steel) Seal Material (1 = Neoprene / 3 = Silicone) Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) Reduced bore option Gland size (Cable Range) Entry thread B A D Sample: EX-20-B-1-0-R-20-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 & EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd IIC/Exe II 4X, Class 1, Zone 1 Sira 05ATEX1120X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-20-B-1-0-R-20-M20 XX Sira 05ATEX1120X II 2GD EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-20 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use Type EX-20 Gland IIC, IIB, IIA NO Any Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 liters or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 and IP68 @ 25 meters, Enclosure Type 4X Meets the requirements of DTS01 1991 OPERATING TEMPERATURES Standard Seals -20C to +85C Extended Seals - 60C to +180C (Silicone seals) MATERIALS Brass CZ121 (EX-20-B) 316 Stainless Steel (EX-20-S) Inner and outer sheath material: Standard (EX-20-W-1) Neoprene, black. Option (EX-20-W-3) Silicone, white. Reduced bore outer sheath seal (R) Silicone, red (EX-20-W-X-Y-R) Entry thread seal: Nitrile is supplied with neoprene seal version. Silicone is supplied with silicone seal version 4 C THREADS SEALS ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) PLATING Extended operating temperature -60C to +180C, halogen free versions: Brass (EX-20-B-3); 316 Stainless Steel (EX-20-S-3) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC) Gland and accessory kits: K1- includes gland, locknut, earthtag, nylon IP washer and PVC shroud Gland Size Entry Threads Entry Thread Length Max Max Across Protrusion Corners Length Cable Inner Sheath [C] Min Metric NPT/BSP [B] Gland Seal Range Cable Outer Sheath [D] Standard Reduced (R) Max Min Max Min Armor Acceptance Range Shroud Size Max [A] 16 M20 N1 or N2 16 28.0 78.0 3.4 8.4 9.0 13.5 6.7 10.3 0.15 - 1.25 L24 20s M20 N1 or N2 16 28.0 78.0 7.2 11.7 11.5 16.0 9.4 12.5 0.15 - 1.25 L24 20 M20 N1 or N2 16 33.0 78.0 9.4 14.0 15.5 21.1 12.0 17.6 0.15 - 1.25 EL30 25 M25 N2 or N3 16 41.4 90.0 13.5 20.0 20.3 27.4 16.8 23.9 0.15 - 1.60 EL38 32 M32 N3 or N4 16 50.6 105.0 19.5 26.3 26.7 34.0 23.2 30.5 0.15 - 2.00 EL46 40 M40 N4 or N5 16 60.5 113.0 23 32.2 33.0 40.6 28.6 36.2 0.20 - 2.00 EL55 50s M50 N5 or N6 16 71.5 125.0 28.1 38.2 39.4 46.7 34.8 42.4 0.30 - 2.50 EL65 50 M50 N6 16 71.5 125.0 33.1 44.1 45.7 53.2 41.1 48.5 0.30 - 2.50 EL65 63s M63 N6 or N7 19 88.0 125.0 39.2 50.1 52.1 59.5 47.5 54.8 0.30 - 2.50 EL80 63 M63 N7 19 88.0 125.0 46.7 56.0 58.4 65.8 53.8 61.2 0.30 - 2.50 EL80 75s M75 N7 or N8 19 99.0 131.0 52.1 62.0 64.8 72.2 60.2 68.0 0.30 - 2.50 EL90 75 M75 N8 19 99.0 131.0 58.0 68.0 71.1 78.0 66.5 73.4 0.30 - 2.50 EL90 80 M80 x 2 N8 or N9 25 115.2 170.0 62.2 72.0 77.0 84.0 - - 0.45 - 3.15 L104 80H M80 x 2 N8 or N9 25 115.2 170.0 62.2 72.0 79.6 90.0 - - 0.45 - 3.15 L104 85 M85 x 2 N8 or N9 25 115.2 170.0 69.0 78.0 79.6 90.0 75.0 85.4 0.45 - 3.15 L104 90 M90 x 2 N9 or N10 25 125.7 170.0 74.0 84.0 88.0 96.0 - - 0.45 - 3.15 L114 90H M90 x 2 N9 or N10 25 125.7 170.0 74.0 84.0 92.0 102.0 - - 0.45 - 3.15 L114 100 M100 x 2 N9 or N10 25 125.7 170.0 82.0 90.0 92.0 102.0 87.4 97.4 0.45 - 3.15 L114 All Dimensions are in millimeters NOTES: * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-20 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. * When used to terminate unarmored cable, the gland is suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting. 5 ATEX/CSA Approved Glands with Elastomeric Seals EX-25 EX-25 type glands provide a seal on the inner sheath, a seal on the outer sheath and an armor specific clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EX-25 type connectors can be used to terminate lead sheath cables. EX-25 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP67. EXAMPLE PART NUMBER EX-25* * W X Y R YY ZZ [W] [X] [Y] [R] [YY] [ZZ] - Armor Types (W = SWA / X = SWB / Z = STA) - Gland material (B = Brass / S = Stainless Steel) - Seal Material (1 = Neoprene / 3 = Silicone / 4 = No Seal) - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) - Reduced bore option - Gland size (Cable Range) - Entry Thread B A D C Sample: EX-25-W-B-1-0-R-20-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II SIRA 05ATEX1122X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-25W-B-1-0-R-20-M20 XX SIRA 05ATEX1122X II 2GD IP67 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-25 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use Type EX-25 Gland IIC, IIB, IIA NO Any Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 litres or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 and IP67 OPERATING TEMPERATURES Standard Seals -20C to +80C Silicone Seals - 60C to +180C VARIATIONS Omission of outer seal: Brass (EX-25*-B-4); 316 Stainless Steel (EX-25-*-S-4) MATERIALS Brass CZ121 (EX-25-*-B) 316 Stainless Steel (EX-25-*-S) 6 SEALS Extended operating temperature -60C to +180C, halogen free versions: Brass (EX-25-B-3); 316 Stainless Steel (EX-25-S-3) THREADS ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) CLAMPS PLATING SWA steel wire armor (EX-25-W) SWB woven steel wire armor (EX-25-X) STA steel tape armor (EX-25-Z) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH) Gland and accessory kits: K2 - includes gland, locknut, earthtag, fibre IP washer and PVC shroud K3 - includes gland, locknut, earthtag, nylon IP washer and PCP shroud K4 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud Gland Size Entry Threads Metric Entry Max Max Thread Across Protrusion Length Corners Length [B] [A] Cable Inner Sheath [C] Min Max Gland Seal Range Cable Outer Sheath [D] Standard Reduced (R) Min Max Min Armour Acceptance Range Shroud Size Max W NPT/BSP XZ 16 M20 N1 or N2 16 26.5 58.0 4.0 8.4 8.4 13.5 4.9 10.0 0.90 0.15-0.35 L24 20s M20 N1 or N2 16 26.5 58.0 8.0 11.7 11.5 16.0 9.4 12.5 0.90-1.25 0.15-0.35 L24 20 M20 N1 or N2 16 33.0 58.0 6.7 * 14.0 15.5 21.1 12.0 17.6 0.90-1.25 0.15-0.50 L30 25 M25 N2 or N3 16 41.4 58.0 13.0 20.0 20.3 27.4 16.8 23.9 1.25-1.60 0.15-0.50 L38 32 M32 N3 or N4 16 50.6 65.0 19.0 26.3 26.7 34.0 23.2 30.5 1.60-2.00 0.15-0.55 L46 40 M40 N4 or N5 16 60.5 72.0 25.0 32.2 33.0 40.6 28.6 36.2 1.60-2.00 0.20-0.60 L55 50s M50 N5 or N6 16 71.5 73.0 31.5 38.2 39.4 46.7 34.8 42.4 2.00-2.50 0.20-0.60 L65 50 M50 N6 16 71.5 73.0 36.5 44.1 45.7 53.2 41.1 48.5 2.00-2.50 0.30-0.80 L65 63s M63 N6 or N7 19 88.0 76.0 42.5 50.1 52.1 59.5 47.5 54.8 2.50 0.30-0.80 L80 63 M63 N7 19 88.0 76.0 49.5 56.0 58.4 65.8 53.8 61.2 2.50 0.30-0.80 L80 75s M75 N7 or N8 19 99.0 82.0 54.5 62.0 64.8 72.2 60.2 68.0 2.50 0.30-1.00 L90 75 M75 N8 19 99.0 82.0 60.5 68.0 71.1 78.0 66.5 73.4 2.50 0.30-1.00 L90 80 M80 x 2 N8 or N9 25 115.2 110.0 62.2 72.0 77.0 84.0 - - 3.15 0.45-1.00 L104 80H M80 x 2 N8 or N9 25 115.2 110.0 62.2 72.0 79.6 90.0 - - 3.15 0.45-1.00 L104 85 M85 x 2 N8 or N9 25 115.2 110.0 69.0 78.0 79.6 90.0 75.0 85.4 3.15 0.45-1.00 L104 90 M90 x 2 N9 or N10 25 125.7 110.0 74.0 84.0 88.0 96.0 - - 3.15 0.45-1.00 L114 90H M90 x 2 N9 or N10 25 125.7 110.0 74.0 84.0 92.0 102.0 - - 3.15 0.45-1.00 L114 100 M100 x 2 N9 or N10 25 125.7 110.0 82.0 90.0 92.0 102.0 87.4 97.4 3.15 0.45-1.00 L114 All Dimensions are in Millimeters NOTES: * EX-25 gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm. * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * "W" refers to the wire diameter in a steel wire armored cable. * "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-25 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 7 ATEX/CSA Approved Glands with Elastomeric Seals EE-30 EE-30 type glands provide a seal on the outer sheath and an armor specific clamp for armored cable. The armor clamp provides an electrical bond between the cable armor and the gland. EE-30 type glands maintain Increased Safety Exe methods of explosion protection and IP66. EXAMPLE PART NUMBER EE-30* * W X Y R YY ZZ [W] [X] [Y] [R] [YY] [ZZ] - Armor Type (W = SWA / X = SWB / Z = STA) - Gland material (B = Brass / S = Stainless Steel) - Seal Material (1 = Neoprene / 3 = Silicone) - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) - Reduced bore option - Gland size (Cablle Range) - Entry thread B A D C Sample: EE-30W-B-1-0-R-20-M20 DESIGN STANDARD EN 50014:1998, EN 50019:2000 and EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exe II SIRA 05ATEX1122X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EE-30W-B-1-0-R-20-M20 XX SIRA 05ATEX1122X II 2GD IP66 EExe II ( XX = Year Code) APPLICATION EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 OPERATING TEMPERATURES Standard Seals -20C to +80C Silicone Seals - 60C to +180C MATERIALS Brass CZ121 (EE-30*-B) 316 Stainless Steel (EE-30*-S) SEALS Extended operating temperature -60C to +180C, halogen free versions: Brass (EE-30*-B-3); 316 Stainless Steel (EE-30*-S-3) THREADS ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) CLAMPS PLATING SWA steel wire armor (EE-30-W) SWB woven steel wire armor (EE-30-X) STA steel tape armor (EE-30-Z) 8 Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH) Gland and accessory kits: K1 - includes gland, locknut, earthtag, nylon IP washer and PVC shroud K4 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud Gland Size Entry Threads Entry Max Max Thread Across Protrusion Length Corners Length [B] [A] Gland Seal Range Cable Inner Sheath [C] Min Max Cable Outer Sheath [D] Standard Reduced (R) Min Max Min Armour Acceptance Range Max W Metric Shroud Size XZ NPT/BSP 16 M20 N1 or N2 10 26.5 54.0 - 11.7 9.0 13.5 6.7 10.3 0.90-1.25 0.15-0.35 L24 20s M20 N1 or N2 10 26.5 54.0 - 11.7 11.5 16.0 9.4 12.5 0.90-1.25 0.15-0.35 L24 20 M20 N1 or N2 10 33.0 54.0 - 14.0 15.5 21.0 12.0 17.6 0.90-1.25 0.15-0.50 L30 25 M25 N2 or N3 10 41.4 54.0 - 20.0 20.3 27.4 16.8 23.9 1.25-1.60 0.15-0.50 L38 32 M32 N3 or N4 10 50.6 60.0 - 26.3 26.7 34.0 23.2 30.5 1.60-2.00 0.15-0.55 L46 40 M40 N4 or N5 15 60.5 67.0 - 32.2 33.0 40.6 28.6 36.2 1.60-2.00 0.20-0.60 L55 50s M50 N5 or N6 15 71.5 67.0 - 38.2 39.4 46.7 34.8 42.4 2.00-2.50 0.20-0.60 L65 50 M50 N6 15 71.5 67.0 - 44.1 45.7 53.2 41.1 48.5 2.00-2.50 0.30-0.80 L65 63s M63 N6 or N7 15 88.0 69.0 - 50.1 52.1 59.5 47.5 54.8 2.50 0.30-0.80 L80 63 M63 N7 15 88.0 69.0 - 56.0 58.4 65.8 53.8 61.2 2.50 0.30-0.80 L80 75s M75 N7 or N8 15 99.0 77.0 - 62.0 64.8 72.2 60.2 68.0 2.50 0.30-1.00 L90 75 M75 N8 15 99.0 77.0 - 68.0 71.1 78.0 66.5 73.4 2.50 0.30-1.00 L90 80 M80 x 2 N8 or N9 20 115.2 104.0 - 72.0 77.0 84.0 - - 3.15 0.45-1.00 L104 80H M80 x 2 N8 or N9 20 115.2 104.0 - 72.0 79.6 90.0 - - 3.15 0.45-1.00 L104 85 M85 x 2 N8 or N9 20 115.2 104.0 - 78.0 79.6 90.0 75.0 85.4 3.15 0.45-1.00 L104 90 M90 x 2 N9 or N10 20 125.7 104.0 - 84.0 88.0 96.0 - - 3.15 0.45-1.00 L114 90H M90 x 2 N9 or N10 20 125.7 104.0 - 84.0 92.0 102.0 - - 3.15 0.45-1.00 L114 100 M100 x 2 N9 or N10 20 125.7 104.0 - 90.0 92.0 102.0 87.4 97.4 3.15 0.45-1.00 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * "W" refers to the wire diameter in a steel wire armored cable. * "XZ" refers to the wire diameter in a woven steel wire armored cable or the tape thickness in a steel tape armored cable. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * Where EX-30 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 9 ATEX/CSA Approved Glands with Elastomeric Seals EX-35 EX-35 type glands provide a single pull resistant seal on the outer sheath of unarmoured cable. EX-35 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 meters. Integral O-Ring entry thread seal, as illustrated, is provided as standard on metric versions. EXAMPLE PART NUMBER EX-35 W X Y YY ZZ [W] - [X] [Y] [YY] [ZZ] Gland material (B = Brass / S = Stainless Steel) Seal Material (1 = Neoprene / 3 = Silicone) Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) Gland size (Cable Range) Entry thread B A D Sample: EX-35-B-1-0-20-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998 CERTIFICATION. CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd IIC/Exe II 4X, Class 1, Zone 1 SIRA 05ATEX1123X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-35-B-1-0-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-35 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-35 Gland IIC, IIB, IIA NO 2 liters or less Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 liters or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 and IP68 @ 25 meters, Enclosure Type 4X OPERATING TEMPERATURES Standard Seals -20C to +80C Silicone Seals - 60C to +180C MATERIALS Brass CZ121 (EX-35-B) 316 Stainless Steel (EX-35-S) Outer sheath seal material: Standard (EX-35-W-1) Neoprene, black. Option (EX-35-W-3) Silicone, white. Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version. 10 THREADS SEALS PLATING ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) Extended operating temperature -60C to +180C, halogen free versions: Brass (EX-35-B-3); 316 Stainless Steel (EX-35-S-3) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-SPVC); PCP (EX-SPCP); Low Smoke Zero Halogen (EX-LSH) Gland and accessory kits: K2 - includes gland, locknut, fiber IP washer and PVC shroud K3- includes gland, locknut, nylon IP washer and PCP shroud Gland Size Entry Threads Entry Thread Length Max Across Corners Max Protrusion Length Gland Seal Rance Shroud Size Cable Outer/Lead Sheath [B] [A] Min Max N1 or N2 16 28.0 33.0 4.0 8.4 M20 N1 or N2 16 M20 N1 or N2 16 28.0 33.0 7.2 11.7 L24 33.0 33.0 9.6 14.0 L30 25 M25 N2 or N3 16 41.4 33.0 13.5 20.0 L38 32 M32 40 M40 N3 or N4 16 50.6 33.0 19.5 26.3 L46 N4 or N5 16 60.5 37.0 23.0 32.2 L55 50s M50 N5 or N6 16 71.5 37.0 28.2 38.2 L65 50 M50 N6 16 71.5 37.0 33.2 44.1 L65 63s M63 N6 or N7 19 88.0 37.0 39.3 50.1 L80 63 M63 N7 19 88.0 37.0 46.7 56.0 L80 75s M75 N7 or N8 19 99.0 37.0 52.3 62.0 L90 75 M75 N8 19 99.0 37.0 58.1 68.0 L90 80 M80 x 2 N8 or N9 25 115.2 50.0 62.3 72.0 L104 85 M85 x 2 N8 or N9 25 115.2 50.0 69.1 78.0 L104 Metric NPT/BSP 16 M20 20s 20 L24 90 M90 x 2 N9 or N10 25 125.7 50.0 74.1 84.0 L114 100 M100 x 2 N9 or N10 25 125.7 50.0 82.1 90.0 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 11 ATEX/CSA Approved Glands with Elastomeric Seals EX-40 EX-40 type glands provide two pull resistant seals on the outer sheath of any cable. EX-40 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 meters. An integral O-Ring entry thread seal, as illustrated, is provided as standard on metric versions. EXAMPLE PART NUMBER EX-40 W X Y YY ZZ [W] - [X] [Y] [YY] [ZZ] Gland material (B = Brass / S = Stainless Steel) Seal Material (1 = Neoprene / 3 = Silicone) Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) Gland size (Cable Range) Entry thread A D Sample: EX-40-B-1-0-20-M20 B DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd IIC/Exe II 4X, Class 1, Zone 1 SIRA 05ATEX1123X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-40-B-1-0-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-40 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-40 Gland IIC, IIB, IIA NO Any Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 litres or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 and IP68 @ 25 meters, Enclosure Type 4X OPERATING TEMPERATURES Standard Seals -20C to +80C Silicone Seals - 60C to +180C MATERIALS Brass CZ121 (EX-40-B) 316 Stainless Steel (EX-40-S) Outer sheath seal material: Standard (EX-40-W-1) Neoprene, black. Option (EX-40-W-3) Silicone, white Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version. 12 THREADS SEALS ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) PLATING Extended operating temperature -60C to +180C, halogen free versions: Brass (EX-40-B-3); 316 Stainless Steel (EX-40-S-3) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC); PCP (EX-PCP); Low Smoke Zero Halogen (EX-LSH) Gland Size Entry Threads Entry Thread Length Max Across Corners [B] [A] N1 or N2 16 28.0 M20 N1 or N2 16 M20 N1 or N2 16 Metric NPT/BSP 16 M20 20s 20 Max Protrusion Length Gland Seal Rance Shroud Size Cable Outer/Lead Sheath Min Max 66.0 4.0 8.4 28.0 66.0 7.2 11.7 L24 29.7 66.0 9.6 14.0 L27 L24 25 M25 N2 or N3 16 39.6 66.0 13.5 20.0 L36 32 M32 N3 or N4 16 45.1 66.0 19.5 26.3 L41 40 M40 N4 or N5 16 55.9 74.0 23.0 32.2 L51 50s M50 N5 or N6 16 71.5 74.0 28.2 38.2 L65 50 M50 N6 16 71.5 74.0 33.2 44.1 L65 63s M63 N6 or N7 19 88.0 74.0 39.3 50.1 L80 63 M63 N7 19 88.0 74.0 46.7 56.0 L80 75s M75 N7 or N8 19 99.0 74.0 52.3 62.0 L90 75 M75 N8 19 99.0 74.0 58.1 68.0 L90 80 M80 x 2 N8 or N9 25 115.2 100.0 62.3 72.0 L104 85 M85 x 2 N8 or N9 25 115.2 100.0 69.1 78.0 L104 90 M90 x 2 N9 or N10 25 125.7 100.0 74.1 84.0 L114 100 M100 x 2 N9 or N10 25 125.7 100.0 82.1 90.0 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 13 . ATEX/CSA Approved Glands with Elastometric Seals EX-45 EX-45 type glands provide a seal on the outer sheath of unarmoured cable and a conduit connection thread. EX40-M type glands provide a male thread for connection and EX-40-F type glands provide a female thread for connection. EX-45 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 metres. An `O' ring IP entry thread seal is fitted as standard. EXAMPLE PART NUMBER EX-45 A W X Y Z YY ZZ [A] - [W] [X] [Y] [YY] [ZZ] M = Male Connector / F = Female Connector Gland material (B = Brass / S = Stainless Steel) Seal Material (1 = Neoprene / 3 = Silicone) Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) Connection Thread Gland size (Cable Range) Entry thread B A D B A Sample: EX-45-F-B-1-0-M20-20-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd IIC/Exe II 4X, Class 1, Zone 1 SIRA 05ATEX1123X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-45-F-B-1-0-M20-20-M20 XX SIRA 05ATEX1123X II 2GD IP68 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-45 type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-45 Gland IIC, IIB, IIA NO Any Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 litres or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 and IP68 @ 25 meters, Enclosure Type 4X OPERATING TEMPERATURES Standard Seals -20C to +80C Silicone Seals - 60C to +180C MATERIALS Brass CZ121 (EX-45-A-B) 316 Stainless Steel (EX-45-A-S) Outer sheath seal material: Standard (EX-45-A-W-1) Neoprene, black. Option (EX-45-A-W-3) Silicone, white Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version. 14 D THREADS SEALS ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG PLATING Extended operating temperature -60C to +180C, halogen free versions: Brass (EX-45-A-B-3); 316 Stainless Steel (EX-45-A-S-3) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Gland Size Entry Threads Entry Thread Length Max Across Corners Gland Seal Rance Conduit Connector Cable Outer Sheath [D] [B] Metric [A] Min Max NPT/BSP NPT ISO 16 M20 N1 or N2 16 28.0 4.0 8.4 N1 or N2 M20 20s M20 N1 or N2 16 28.0 7.2 11.7 N1 or N2 M20 20 M20 N1 or N2 16 33.0 9.6 14.0 N1 or N2 M20 25 M25 N2 or N3 16 41.4 13.5 20.0 N2 or N3 M25 32 M32 N3 or N4 16 50.6 19.5 26.3 N3 or N4 M32 40 M40 N4 or N5 16 60.5 23.0 32.2 N4 or N5 M40 50s M50 N5 or N6 16 71.5 28.2 38.2 N5 or N6 M50 50 M50 N6 16 71.5 33.2 44.1 N6 M50 63s M63 N6or N7 19 88.0 39.3 50.1 N6or N7 M63 63 M63 N7 19 88.0 46.7 56.0 N7 M63 75s M75 N7 or N9 19 99.0 52.3 62.0 N7 or N9 M75 75 M75 N9 19 99.0 58.1 68.0 N9 M75 All Dimensions are in Millimeters NOTES: * Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-35 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. * Other conduit connection threads eg PG, BSP are available upon request. 15 ATEX/CSA Approved Glands with Elastometric Seals EE-RG EE-RG type glands provide a seal on the outer sheath of unarmoured cable. EE-RG type glands maintain Increased Safety Exe method of explosion protection and IP66, IP68. EXAMPLE PART NUMBER EE-RG[X]-[ZZ] X - Material (1 = Black Polyamide 6 / 2 = Blue Polyamide 6 / 3 = Grey Polyamide 6) ZZ - Entry Thread EE-RG1-M20 DESIGN STANDARD EN50014:1997 and EN50019:2000 CERTIFICATION ATEX II 2 GD, E Exe II CERTIFICATE SIRA 00ATEX 1072 - Ex Notified Body No. 0518 GLAND MARKING Example: SIRA 00ATEX1072X EB (Cable Range) II2GD EExeII For industrial versions the hazardous area information is omitted APPLICATION Exe Equipment Gas Group II, Zones 1 and 2 INGRESS PROTECTION IP66 without a sealing washer IP68 with a sealing washer OPERATING TEMPERATURES Sizes M25 and below: -20C to +60C Sizes above M25: -10C to +60C MATERIALS Standard (EX-RG1) Black Polyamide 6 Option (EE-RG2) Blue Polyamide 6 Industrial, Non Ex Versions: Grey Polyamide 6 (EE-RG3) Note: Polyamide 6 is self extinguishing, flame retardant and halogen free Outer Seath seal material: Santoprene, black THREADS ISO Metric ACCESSORIES Locknut - Nylon (EX-NLN); Brass (EX-BLN) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) 16 Gland Size Entry Thread Length Max Across Corners Metric Gland Seal Range Cable Outer Sheath Min Max 6.0 - 9 16.5 3.5 M16 9 20.9 5.0 8.0 - 9 24.2 6.0 10.0 M20 10 26.4 8.0 13.5 - 10 28.6 10.0 15.0 M25 11 35.2 13.0 19.0 M32 12 45.1 18.0 25.0 M40 14 57.2 24.0 32.0 M50 16 64.9 29.0 38.0 M63 16 71.5 36.0 44.0 All Dimensions are in Millimeters NOTES: * Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting * Gland sizes M25 and above shall not be used for applications where there is a "high" risk of mechanical damage * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full 17 ATEX/CSA Approved Glands with Elastometric Seals for Flat Cable EX-50 EX-50 type glands provide pull resistant seals on the inner and outer sheath and a braid armor clamp. The armor clamp provides an electrical bond between the cable armor and the gland. EX-50 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66. EXAMPLE PART NUMBER EX-50 [W] [Y] [YY] [ZZ] W - Gland Material (B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) YY - Gland Size (Cable Range) ZZ - Entry Thread B A D C Sample: EX-50-B-3-20S-M20 DESIGN STANDARD EN 50014:1998, EN 50018:2000, EN 50019:2000 and EN 50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II SIRA 05ATEX1121X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-50-B-3-20S-M20 XX SIRA 05ATEX1121X II 2GD IP66 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-50 type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-50 Gland IIC, IIB, IIA NO 2 litres or less Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 litres or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 OPERATING TEMPERATURES Standard Seals - 60C to +180C MATERIALS Brass CZ121 (EX-50-B) 316 Stainless Steel (EX-50-S) PLATING THREADS Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) 18 ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Gland Size Entry Threads Metric Entry Thread Length Max Across Corners [B] [A] Gland Seal Range Max Protrusion Length Cable Inner Sheath [C] Width Thickness Min Max Min Max Cable Outer Sheath [D] Width Min Max Thickness Min Max Armor Acceptance Range [X] 20s M20 16 26.5 58.0 6.3 11.7 4.0 7.0 7.9 11.7 4.5 7.0 0.1-0.3 20R M20 16 33.0 58.0 8.1 13.5 5.8 6.2 7.5 16.1 3.0 8.3 0.1-0.45 20 M20 16 33.0 58.0 10.3 13.5 5.6 9.0 11.0 13.5 4.5 9.0 0.1-0.3 All Dimensions are in Millimeters NOTES: * Gland Size does not necessarily equate to the entry thread size. * "X" refers to the wire diameter in a braided cable. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-50 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 19 ATEX/CSA Approved Glands with Elastometric Seals for Flat Cable EX-55 EX-55 type glands provide a single pull resistant seal on the outer sheath of unarmoured flat cable. EX-55 type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP68 to 25 meters. EXAMPLE PART NUMBER B EX-55 [W] [Y] [YY] [ZZ] W - Gland Material(B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) YY - Gland Size (Cable Range) ZZ - Entry Thread A D EX-55-B-3-20S-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN50281-1-1:1998 CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II SIRA 05ATEX1121X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-55-B-3-20S-M20 XX SIRA 05ATEX1121X II 2GD IP68 EExdIIC / EExe II (XX = Year Code) APPLICATION EExd Equipment EX-55 type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-55 Gland IIC, IIB, IIA NO Any Zone 1 or 2 YES IIB, IIA YES Any Zone 2 YES IIB, IIA YES 2 litres or less Zone 1 YES EExe Equipment Gas Group II, Zones 1 and 2 Other Equipment Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP68 @ 25 meters OPERATING TEMPERATURES Standard Seal - 60C to +180C (Silicone seal) MATERIALS Brass CZ121 (EX-55-B) 316 Stainless Steel (EX-55-S) Outer sheath seal material: Silicone, red or white THREADS PLATING ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) 20 ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Gland Size Entry Threads Entry Thread Length Max Across Corners Gland Seal Range Cable Outer Sheath [D] Metric [B] [A] Min Max Width Thickness Min Max 20s M20 16 26.5 6.3 11.7 4.0 7.0 20R M20 16 33.0 8.1 13.5 5.8 6.2 20 M20 16 33.0 10.3 13.5 5.6 9.0 All Dimensions are in Millimeters NOTES: * Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * Where EX-55 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 21 ATEX / CSA Approved Compound Filled Barrier Glands EX-60 EX-60 type glands provide a Flameproof EExd compound filled barrier, a seal on the outer sheath, a universal armor clamp for armored, screened or braided cable and an entry thread seal. The armor clamp provides an electrical bond between the cable armor, screen or braid and the gland. EX-60 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant. EXAMPLE PART NUMBER EX-60 [W] [Y] [R] [YY] [ZZ] W - Gland Material (B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) R - Reduced bore option YY - Gland Size (Cable Range) ZZ - Entry Thread B A D EX-60-B-1-R-20S-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, EN50019:2000 and EN50281-1-1:1998 IEC 60079-0 (2000-06), IEC 60079-1 (2001-02) CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd I & IIC 4X, Class 1, Zone 1 SIRA 05SIRA1124X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-60-B-1-R-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68 (XX = Year Code) APPLICATION EExd Equipment EX-60 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-60 Gland I, IIC, IIB, IIA YES Any Zone 1 or 2 YES Other Equipment Mining Equipment Group I, M2 Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 & IP68 @ 100 Meters Meets the requirements of DTS01 1991 CURING TIME @ 21C Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours The compound chamber can be inspected after 4 hours OPERATING TEMPERATURES - 60C to +85C 22 C MATERIALS Brass CZ121 (EX-60-B) 316 Stainless Steel (EX-60-S) Inner LSOH compound Standard outer sheath seal is LSOH silicone, white (EX-60-W-Y) Reduced bore outer sheath seal is LSOH silicone, red (EX-60-W-Y-R) Entry thread Seal: Red LSOH silicone THREADS PLATING ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC) Gland and accessory kits: K5- includes gland, locknut, earthtag, integral IP "O" ring & PVC shroud Gland Size Entry Threads Entry Thread Length Max Max Across Protrusion Corners Length [B] [A] GlandSeal Range Cable Inner Cable Outer Sheath [D] Standard Reduced (R) Sheath / Cores [C] Max Max No. of Over Metric NPT/BSP 16 M20 N1 or N2 16 28.0 72.0 20s M20 N1 or N2 16 28.0 20 M20 N1 or N2 16 33.0 Armor Acceptance Range Max Inner Min Max Min Max 6.7 10.3 0.15 - 1.25 Shroud Size 7 9.0 11.7 9.0 13.5 L24 72.0 8 10.4 11.7 11.5 16.0 9.4 12.5 0.15 - 1.25 L24 73.0 14 12.5 14.0 15.5 21.1 12.0 17.6 0.15 - 1.25 EL30 25 M25 N2 or N3 16 41.4 83.0 25 17.8 20.0 20.3 27.4 16.8 23.9 0.15 - 1.60 EL38 32 M32 N3 or N4 16 50.6 103.0 50 23.5 26.3 26.7 34.0 23.2 30.5 0.15 - 2.00 EL46 40 M40 N4 or N5 16 60.5 105.0 80 28.8 32.2 33.0 40.6 28.6 36.2 0.20 - 2.00 EL55 50s M50 N6 16 71.5 115.0 100 34.2 38.2 39.4 46.7 34.8 42.4 0.20 - 2.50 EL65 50 M50 N6 16 71.5 115.0 100 39.4 44.1 45.7 53.2 41.1 48.5 0.20 - 2.50 EL65 63s M63 N7 19 88.0 115.0 120 44.8 50.1 52.1 59.5 47.5 54.8 0.30 - 2.50 EL80 63 M63 N7 19 88.0 115.0 120 50.0 56.0 58.4 65.8 53.8 61.2 0.30 - 2.50 EL80 75s M75 N8 19 99.0 122.0 140 55.4 62.0 64.8 72.2 60.2 68.0 0.30 - 2.50 EL90 75 M75 N8 19 99.0 122.0 140 60.8 68.0 71.1 78.0 66.5 73.4 0.30 - 2.50 EL90 80 M80x2 N8 or N9 25 115.2 162.0 160 64.4 72.0 77.0 84.0 - - 0.45 - 3.15 L104 85 M85x2 N8 or N9 25 115.2 162.0 180 69.8 78.0 79.6 90.0 75.0 85.4 0.45 - 3.15 L104 90 M90x2 N9 or N10 25 125.7 166.0 200 75.1 84.0 88.0 96.0 - - 0.45 - 3.15 L114 100 M100x2 N9 or N10 25 125.7 166.0 220 80.5 90.0 92.0 102.0 87.4 97.4 0.45 - 3.15 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * If EX-60 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 23 ATEX / CSA Approved Compound Filled Barrier Glands EX-65 EX-65 type glands provide a Flameproof EExd compound filled barrier and an entry thread seal. EX-65 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant. EXAMPLE PART NUMBER EX-65 [W] [Y] [YY] [ZZ] W - Gland Material (B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) YY - Gland Size (Cable Range) ZZ - Entry Thread B A D EX-65-B-1-20S-M20 DESIGN STANDARD. EN50014:1998, EN50018:2000, & EN50281-1-1:1998 IEC 60079-0 (2000-06), IEC 60079-1 (2001-02) CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1 SIRA 05ATEX1124X - Ex Notified Body No. 0518 Pending GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-65-B-1-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68 (XX = Year Code) APPLICATION EExd Equipment EX-65 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-65 Gland I, IIC, IIB, IIA YES Any Zone 1 or 2 YES Other Equipment Mining Equipment Group I, M2 Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 & IP68 @ 100 Meters Meets the requirements of DTS01 1991 CURING TIME @ 21C Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours The compound chamber can be inspected after 4 hours OPERATING TEMPERATURES -60C to +85C 24 C MATERIALS Brass CZ121 (EX-65-B) 316 Stainless Steel (EX-65-S) Inner LSOH compound Entry thread Seal: Red LSOH silicone PLATING THREADS Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC) Gland and accessory kits: K5- includes gland, locknut, earthtag, integral IP "O" ring & PVC shroud Gland Size Entry Threads Entry Thread Length Max Across Corners [B] [A] Max Protrusion Length Gland Seal Range Cable Sheath / Cores Shroud Size Max No. of Cores Max Over Cores [C] Max Sheath Diameter [D] Metric NPT/BSP 20s M20 N1 or N2 16 28.0 42.0 8 10.4 11.7 L24 20 M20 N1 or N2 16 33.0 44.0 14 12.5 14.0 L20 25 M25 N2 or N3 16 41.4 48.0 25 17.8 20.0 L38 32 M32 N3 or N4 16 50.6 53.0 50 23.5 26.3 L46 40 M40 N4 or N5 16 60.5 54.0 80 28.8 32.2 L55 50 M50 N6 16 71.5 54.0 100 39.4 44.1 L65 63 M63 N7 19 88.0 55.0 120 50.0 56.0 L80 75 M75 N8 19 99.0 60.0 140 60.8 68.0 L90 80 M80x2 N8 or N9 25 115.2 80.0 160 64.4 72.0 L104 85 M85x2 N8 or N9 25 115.2 80.0 180 69.8 78.0 L104 90 M90x2 N9 or N10 25 125.7 85.0 200 75.1 84.0 L114 100 M100x2 N9 or N10 25 125.7 85.0 220 80.5 90.0 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * If EX-65 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 25 ATEX / CSA Approved Compound Filled Barrier Glands EX-70 EX-70 type glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer sheath and an entry thread seal. EX-70 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant. EXAMPLE PART NUMBER EX-70 [W] [Y] [YY] [ZZ] W - Gland Material (B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) YY - Gland Size (Cable Range) ZZ - Entry Thread B A D EX-70-B-1-20S-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, & EN50281-1-1:1998 IEC 60079-0 (2000-06), IEC 60079-1 (2001-02) CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1 SIRA 05ATEX1124X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-70-1-20S-M20 XX SIRA 05ATEX1124X I M2 II 2GD EExd I & IIC IP68 APPLICATION EExd Equipment EX-70 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-70 Gland I, IIC, IIB, IIA YES Any Zone 1 or 2 YES Other Equipment Mining Equipment Group I, M2 Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 & IP68 @ 100 Meters Meets the requirements of DTS01 1991 CURING TIME @ 21C Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours The compound chamber can be inspected after 4 hours OPERATING TEMPERATURES -60C to +85C 26 C MATERIALS Brass CZ121 (Ex-70-B) 316 Stainless Steel (EX-70-S) Inner LSOH compound Entry thread Seal: Red LSOH silicone THREADS PLATING ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Shroud - PVC (EX-PVC) Gland and accessory kits: K5- includes gland, locknut, integral IP "O" ring & PVC shroud Gland Size Entry Threads Entry Thread Length Max Across Corners [B] [A] Max Protrusion Length Gland Seal Range Cable Inner Sheath / Cores [C] Cable Outer Sheath [D] Max No. of Cores Max Over Cores Max Sheath Diameter Min Max 7 8.4 8.4 3.4 8.4 Shroud Size Metric NPT/BSP 16 M20 N1 or N2 16 28.0 73.0 20s M20 N1 or N2 16 28.0 73.0 8 10.4 11.7 4.8 11.7 L24 20 M20 N1 or N2 16 33.0 73.0 14 12.5 14.0 9.5 14.0 EL30 25 M25 N2 or N3 16 41.4 74.0 25 17.8 20.0 11.7 20.0 EL38 32 M32 N3 or N4 16 50.6 80.0 50 23.5 26.3 18.1 26.3 EL46 40 M40 N4 or N5 16 60.5 87.0 80 28.8 32.2 22.6 32.2 EL55 50s M50 N6 16 71.5 87.0 100 34.2 38.2 28.2 38.2 EL65 L24 50 M50 N6 16 71.5 87.0 100 39.4 44.1 33.1 44.1 EL65 63s M63 N7 19 88.0 88.0 120 44.8 50.1 39.3 50.1 EL80 63 M63 N7 19 88.0 88.0 120 50.0 56.0 46.7 56.0 EL80 75s M75 N8 19 99.0 97.0 140 55.4 62.0 52.3 62.0 EL90 75 M75 N8 19 99.0 97.0 140 60.8 68.0 58.0 68.0 EL90 80 M80x2 N8 or N9 25 115.2 123.0 160 64.4 72.0 61.9 72.0 L104 85 M85x2 N8 or N9 25 115.2 123.0 180 69.8 78.0 69.1 78.0 L104 90 M90x2 N9 or N10 25 125.7 123.0 200 75.1 84.0 74.1 84.0 L114 100 M100x2 N9 or N10 25 125.7 123.0 220 80.5 90.0 81.8 90.0 L114 All Dimensions are in Millimeters NOTES: * NPT entry thread reference details on page 53. * Gland Size does not necessarily equate to the entry thread size. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * If EX-70 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 27 ATEX / CSA Approved Compound Filled Barrier Glands EX-75 EX-75 type glands provide a Flameproof EExd compound filled barrier seal on the cables individual conductors within a conduit. It also provides an entry thread seal. EX-75 type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant. EXAMPLE PART NUMBER EX-75 [W] [Y] [YY] [ZZ1] [ZZ2] W - Gland Material (B = Brass / S = Stainless Steel) Y - Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) YY - Gland Size (Cable Range) ZZ1 - Male Thread ZZ2 - Female Entry Thread MATING CONDUIT OR CABLE GLAND A B D EX-75-B-1-20S-M20 DESIGN STANDARD EN50014:1998, EN50018:2000, & EN50281-1-1:1998 IEC 60079-0 (2000-06), IEC 60079-1 (2001-02) CERTIFICATION CERTIFICATE ATEX II 2 GD, E Exd IIC / E Exe II CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1 SIRA 03ATEX1479X - Ex Notified Body No. 0518 GLAND MARKING CENELEC and ATEX Example: Amphenol 13838 USA EX-75-B-1-20S-M20 XX SIRA05ATEX1120X I M2 II 2GD EExd I & IIC IP68 APPLICATION EExd Equipment EX-75 type Glands will maintain Flameproof Exd integrity when used with any armored or unarmored cable types. Ref: IEC60079-14:2002 Section 10.4.2 Gas Group Internal Ignition Source Enclosure Volume Which Zone Use EX-75 Gland I, IIC, IIB, IIA YES Any Zone 1 or 2 YES Other Equipment Mining Equipment Group I, M2 Ignitable Dust, Zones 21 and 22 INGRESS PROTECTION IP66 & IP68 @ 100 Meters Meets the requirements of DTS01 1991 CURING TIME @ 21C Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours The compound chamger can be inspected after 4 hours OPERATING TEMPERATURES -60C to +85C 28 C MATERIALS Brass CZ121 (EX-75-B) 316 Stainless Steel (EX-75-S) Inner LSOH compound Entry thread Seal: Red LSOH silicone THREADS PLATING ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel) Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) ACCESSORIES Locknut - Brass (EX-BLN); 316 Stainless Steel (EX-SLN) Earth Tag - Brass (EX-BET), 316 Stainless Steel (EX-SET) IP Washer - Nylon (EX-NSW); Red Fibre (EX-FSW) Serrated Lock Washer - 316 Stainless Steel (EX-SSW), Galvanised Steel (EX-GSW) Fitting Size Ref Male Entry Female Entry Entry Thread Length Max Across Corners Metric NPT Metric NPT [B] [A] 20 M20 N1 or N2 M20 N1 or N2 16 33.0 25 M25 N2 or N3 M25 N2 or N3 16 41.4 32 M32 N3 or N4 M32 N3 or N4 16 40 M40 N4 or N5 M40 N4 or N5 16 50 M50 N6 M50 N6 63 M63 N7 M63 N7 Max Protrusion Length Sealing Range Cable Conductors / Cores Max No. of Cores Max Over Cores [C] Max Cable Inside Fitting [D] 57.0 14 12.5 14.0 63.0 25 17.8 20.0 50.6 67.0 50 23.5 26.3 60.5 68.0 80 28.8 32.2 16 71.5 68.0 100 39.4 44.1 19 88.0 72.0 120 50.0 56.0 75 M75 N8 M75 N8 19 99.0 78.0 140 60.8 68.0 80 M80x2 N8 or N9 M80x2 N8 or N9 25 115.2 103.0 160 64.4 72.0 85 M85x2 N8 or N9 M85x2 N8 or N9 25 115.2 103.0 180 69.8 78.0 90 M90x2 N9 or N10 M90x2 N9 or N10 25 125.7 104.0 200 75.1 84.0 100 M100x2 N9 or N10 M100x2 N9 or N10 25 125.7 104.0 220 80.5 90.0 All Dimensions are in Millimeters NOTES: * NPT thread reference details on page 53. * Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions. * Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required. * Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch. * For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads. * If EX-75 type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system. * The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation. * To maintain ingress protection a thread sealant should be applied to the conduit thread. * Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full. 29 Non-Hazardous Industrial Glands CGA CGA type glands provide an integral armor clamp for armored cable. The integral armor clamp provides an electrical bond between the cable armor and the gland. CGA type glands maintain IP30. EXAMPLE PART NUMBER CG[X] X W Y YY ZZ [W] - [Y] [YY] [ZZ] Clamp Type (See Clamps) Gland Material ( B = Brass / S = Stainless Steel) Plating (0 = No Plating / 1 = Nickel / 2 = Tin / 3 = Zinc / 4 = Electroless Nickel) Gland Size (Cable Range) Entry Thread B A D D Sample: CGA-B-3-20S-M20 DESIGN STANDARD BS 6121:1989 GLAND MARKING INGRESS PROTECTION Example: BS6121 Part 1 CGA-B-3-20S-M20 Amphenol IP30 OPERATING TEMPERATURES MATERIALS -100C to +600C Brass CZ121 (CGA-B) VARIATIONS All variants of the CGA type gland feature a separate armor clamping ring to allow for inspection of the clamped armor: Brass (CGA-B) THREADS ISO Metric only CLAMPS PLATING SWA Clamping using gland body (CGA) SWA steel wire armor - clamping ring (CGL) SWB woven steel wire armor or STA steel tape armor - clamping ring (CGZ) ACCESSORIES Locknut - Brass (EX-BLN); Steel (EX-MLN) Earth Tag - Brass (EX-BET) Shroud - PVC (EX-PVC) Gland and accessory kits: K6- includes gland, steel locknut, earthtag and PVC shroud 30 Nickel (1); Tin (2); Zinc (3); Electroless Nickel (4) Gland Size Entry Threads Entry Threads Length M