Total Counter/Time Counter (DIN 48 x 24) H7GP CSM_H7GP_DS_E_4_1 DIN 48 x 24-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 * High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and built-in red LED backlight at low power consumption. * IP66 with oil resistance and NEMA 4 protection achieved by unifying the front with the case and by using oil-resistant parts and materials. * Compact (80 mm) body. * Just change a switch setting for either an NPN or PNP input. * Supports both external resetting and manual resetting. * Finger-protection terminal block cover prevents electrical shock and conforms to VDE0106, Part 100. * Certified for UL and CSA safety standards. * Complies with EMC standards (EN 61326) and CE Marking. Model Number Structure Model Number Legend H7GP-@@@ 1 2 3 3. Case Color of Front Section None: Light gray (Munsell 5Y7/1) B: Black 1. Classification C: Total counter T: Time counter 2. Supply Voltage None: 100 to 240 VAC D: 12 to 24 VDC Ordering Information List of Models Total counter Supply voltage 6-digit total counter Light gray Black 100 to 240 VAC H7GP-C H7GP-CB 12 to 24 VDC H7GP-CD H7GP-CDB Time counter Supply voltage 6-digit time counter Light gray Black 100 to 240 VAC H7GP-T H7GP-TB 12 to 24 VDC H7GP-TD H7GP-TDB 1 H7GP Specifications Ratings Item 6-digit total counter H7GP-C 6-digit time counter H7GP-CD H7GP-T H7GP-TD Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) External power supply 50 mA at 12 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. Dimensions 48 x 24 x 80 mm (W x H x D) Mounting method Flush mounting External connections Screw terminals Degree of protection Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors). Display 7-segment, negative transmissive LCD (with red backlight) --- 50 mA at 12 VDC --- Digits 6 digits (8.5-mm-high characters) Input mode Up (increment) Accumulative Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch) --- Counting range 0 to 999999 --- Time specification --- 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s 100 ppm (-10C to 55C) Timing accuracy --- Memory backup EEP-ROM: 200,000 operations min. Input Input signals Count, reset, and key protection (see note 2) Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) Start, reset, and key protection (see note 2) Count, reset, start No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage:2 VDC max. Open (OFF) impedance: 100 k min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 k max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 k max. Key protection No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage:0.5 VDC max. Open (OFF) impedance: 100 k min. Input response speed Reset 20 or 1 ms (automatically switched according to counting 20 ms speed) Start --- Key protection Approx. 1 s Reset system 20 ms Approx. 1 s External and manual resets Note: 1. Contains 20% ripple (p-p) max. 2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional. 2 H7GP Characteristics Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) Noise immunity 1.5 kV (between AC power terminals), 480 V (between DC power terminals), 480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Display: Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions Shock resistance Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions Ambient temperature Operating: -10C to 55C (with no icing) Storage: -25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% EMC (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class A EN55011 Group 1 class A EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) Approved standards UL508, CSA22.2 No.14, conforms to EN61010-1, VDE0106/P100 Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) Weight Approx. 75 g Malfunction:8 kV Destruction:15 kV DIP switch: Malfunction:4 kV Destruction:8 kV 3 H7GP Connections Terminal Arrangement Note: Non-contact input is also available. AC Models H7GP-C External power supply 12 VDC 50 mA max. 100 to 240 VAC Power supply Power supply 5 6 7 1 2 3 Reset input Count input Key protection input 0V H7GP-T External power supply 12 VDC 50 mA max. 100 to 240 VAC Power supply Power supply 8 5 6 7 8 4 1 2 3 4 12 VDC Key protection input Unused Reset input 0V Count input 12 VDC Unused NPN mode NPN mode PNP mode PNP mode DC Models H7GP-CD H7GP-TD 12 to 24 VDC 0V Power supply 12 to 24 VDC Unused Unused 0V Power supply Unused Unused 5 6 7 8 5 6 7 8 1 2 3 4 1 2 3 4 Reset input Count input Reset input Start input Key protection input NPN mode Unused PNP mode Key protection input NPN mode Unused PNP mode 4 H7GP Operation DIP Switch Settings Set all DIP switches before mounting the Counter to a control panel. All switches are set toward the display panel before shipping. H7GP-T/-TD Switch H7GP-C/-CD Switch Item Function 3 (On right side from front) Input mode (note 1) Display side NPN Terminal side PNP 4 (On left side from front) Counting speed (note 1) Display side 30 Hz Terminal side 5 kHz Item Function 3 (On right side from front) Input mode (note 1) Display side Terminal side NPN PNP 4 (On left side from front) Time range (note 1) Display side 99999.9h (note 2) Terminal side 99 h 59 min 59 s Note: 1. When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. 2. The decimal point will flash every second when "99999.9 h" is set. Operating Modes Total Counters Time Counters Reset input Reset input Count input Start input 999999 99999.9 h (see note) Display Display 0 0.0h Note: The count value will return to "0" when "999999" is exceeded. The display and output are turned OFF when the power supply turns OFF, but the count value is stored internally. Note: Display values are shown for full scale set to 99999.9 h. The count value will return to "0" when "99999.9" is exceeded. The display and output are turned OFF when the power supply turns OFF, but the count value is stored internally. Nomenclature 4 1. Reset Key Resets the count value, but will not operate while the keys are protected. 2 3 1 2. Key Protection Indicator Lit while the keys are protected. (Reset Key is disabled.). 3. NPN/PNP DIP Switch (Count or start with reset) When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. See below for details. 4. Counting Speed DIP Switch (H7GP-C) Time Range DIP Switch (H7GP-T) When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. Refer to DIP Switch Setting for details. 5 H7GP Dimensions Note: All units are in millimeters unless otherwise indicated. H7GP-C H7GP-T Panel Cutouts Panel cutouts are as shown below (according to DIN43700). M3.5 terminal screw 50 min. 5.0 min. 45 +0.6 0 45 +0.6 0 22.2 +0.3 0 22.2 +0.3 0 Terminal cover (provided) Note: 1. The mounting panel thickness should be 1 to 6 mm. 2. Water resistance will be lost if Counters are mounted side-by-side. 3. The terminal screws are M3.5. (Theeffective thread length is 6 mm.) 4. When horizontally mounting Counters side-by-side, leave at least 50 mm between any two Counters. With Flush Mounting Bracket Y92S-32 rubber packing (provided) Panel Y92F-32 flush mounting adaptor (provided) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: H7GP-CDB H7GP-TDB