P4SMA Series Vishay General Semiconductor Surface Mount TRANSZORB(R) Transient Voltage Suppressors FEATURES * Low profile package * Ideal for automated placement * Glass passivated chip junction * Available in uni-directional and bi-directional 400 W peak pulse power capability with a 10/1000 s waveform, repetitive rate (duty cycle): 0.01 % (300 W above 91 V) * Excellent clamping capability * Very fast response time * Low incremental surge resistance * Meets MSL level 1, per J-STD-020, LF maximum peak of 260 C * Solder dip 260 C, 40 s * Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC DO-214AC (SMA) PRIMARY CHARACTERISTICS VBR uni-directional 6.8 V to 540 V VBR bi-directional 6.8 V to 220 V PPPM 400 W, 300 W PD 3.3 W IFSM (uni-directional only) 40 A TJ max. 150 C TYPICAL APPLICATIONS Use in sensitive electronics protection against voltage transients induced by inductive load switching and lighting on ICs, MOSFET, signal lines of sensor units for consumer, computer, industrial and telecommunication. DEVICES FOR BI-DIRECTION APPLICATIONS For bi-directional devices use CA suffix (e.g. P4SMA10CA). Electrical characteristics apply in both directions. MECHANICAL DATA Case: DO-214AC (SMA) Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS compliant, commercial grade Base P/NHE3 - RoHS compliant, high reliability/ automotive grade (AEC Q101 qualified) Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD22-B102 E3 suffix meets JESD 201 class 1A whisker test, HE3 suffix meets JESD 201 class 2 whisker test Polarity: For uni-directional types the band denotes cathode end, no marking on bi-directional types MAXIMUM RATINGS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL Peak power dissipation with a 10/1000 s waveform (1)(2) (Fig. 1) Peak pulse current with a 10/1000 s waveform (1) (Fig. 3) Power dissipation on infinite heatsink, TA = 50 C Peak forward surge current 8.3 ms single half sine-wave uni-directional only (2) Operating junction and storage temperature range VALUE UNIT PPPM 400 W IPPM See next table A PD 3.3 W IFSM 40 A TJ, TSTG - 65 to + 150 C Notes: (1) Non-repetitive current pulse, per Fig. 3 and derated above TA = 25 C per Fig. 2. Rating is 300 W above 91 V (2) Mounted on 0.2 x 0.2" (5.0 x 5.0 mm) copper pads to each terminal Document Number: 88367 Revision: 21-Oct-08 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com www.vishay.com 1 P4SMA Series Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PART NUMBER P4SMA6.8A P4SMA7.5A P4SMA8.2A P4SMA9.1A P4SMA10A P4SMA11A P4SMA12A P4SMA13A P4SMA15A P4SMA16A P4SMA18A P4SMA20A P4SMA22A P4SMA24A P4SMA27A P4SMA30A P4SMA33A P4SMA36A P4SMA39A P4SMA43A P4SMA47A P4SMA51A P4SMA56A P4SMA62A P4SMA68A P4SMA75A P4SMA82A P4SMA91A P4SMA100A P4SMA110A P4SMA120A P4SMA130A P4SMA150A P4SMA160A P4SMA170A P4SMA180A P4SMA200A P4SMA220A P4SMA250A P4SMA300A P4SMA350A P4SMA400A P4SMA440A P4SMA480A P4SMA510A P4SMA540A DEVICE MARKING CODE BREAKDOWN VOLTAGE UNI BI MIN. MAX. 6V8A 7V5A 8V2A 9V1A 10A 11A 12A 13A 15A 16A 18A 20A 22A 24A 27A 30A 33A 36A 39A 43A 47A 51A 56A 62A 68A 75A 82A 91A 100A 110A 120A 130A 150A 160A 170A 180A 200A 220A 250A 300A 350A 400A 440A 480A 510A 540A 6V8C 7V5C 8V2C 9V1C 10C 11C 12C 13C 15C 16C 18C 20C 22C 24C 27C 30C 33C 36C 39C 43C 47C 51C 56C 62C 68C 75C 82C 91C 100C 110C 120C 130C 150C 160C 170C 180C 200C 220C - 6.45 7.13 7.79 8.65 9.5 10.5 11.4 12.4 14.3 15.2 17.1 19.0 20.9 22.8 25.7 28.5 31.4 34.2 37.1 40.9 44.7 48.5 53.2 58.9 64.6 71.3 77.9 86.5 95.0 105 114 124 143 152 162 171 190 209 237 285 333 380 418 456 485 513 7.14 7.88 8.61 9.55 10.5 11.6 12.6 13.7 15.8 16.8 18.9 21.0 23.1 25.2 28.4 31.5 34.7 37.8 41.0 45.2 49.4 53.6 58.8 65.1 71.4 78.8 86.1 95.5 105 116 126 137 158 168 179 189 210 231 263 315 368 420 462 504 535 567 VBR AT IT (1) TEST STAND-OFF CURRENT VOLTAGE IT VWM (V) (mA) 10 10 10 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 5.80 6.40 7.02 7.78 8.55 9.40 10.2 11.1 12.8 13.6 15.3 17.1 18.8 20.5 23.1 25.6 28.2 30.8 33.3 36.8 40.2 43.6 47.8 53.0 58.1 64.1 70.1 77.8 85.5 94.0 102 111 128 136 145 154 171 185 214 256 300 342 376 408 434 459 MAXIMUM REVERSE LEAKAGE AT VWM MAXIMUM PEAK PULSE CURRENT ID (4) (A) IPPM (2) (A) 1000 500 200 50.0 10.0 5.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 38.1 35.4 33.1 29.9 27.6 25.6 24.0 22.0 18.9 17.8 15.9 14.4 13.1 12.0 10.7 9.7 8.8 8.0 7.4 6.7 6.2 5.7 5.2 4.7 4.3 3.9 3.5 3.2 2.2 2.0 1.8 1.7 1.4 1.4 1.3 1.2 1.1 0.90 0.87 0.73 0.62 0.55 0.50 0.46 0.43 0.41 MAXIMUM MAXIMUM CLAMPING TEMPERATURE VOLTAGE OF VBR AT IPPM (%/C) VC (V) 10.5 11.3 12.1 13.4 14.5 15.6 16.7 18.2 21.2 22.5 25.2 27.7 30.6 33.2 37.5 41.4 45.7 49.9 53.9 59.3 64.8 70.1 77.0 85.0 92.0 104 113 125 137 152 165 179 207 219 234 246 274 328 344 414 482 548 602 658 698 740 0.057 0.061 0.065 0.068 0.073 0.075 0.078 0.081 0.084 0.086 0.089 0.090 0.092 0.090 0.096 0.097 0.098 0.099 0.100 0.101 0.101 0.102 0.103 0.104 0.104 0.105 0.105 0.106 0.106 0.107 0.107 0.107 0.106 0.108 0.108 0.108 0.108 0.108 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 Notes: (1) Pulse test: tp 50 ms (2) Surge current waveform per Fig. 3 and derate per Fig. 2 (3) All terms and symbols are consistent with ANSI/IEEE CA62.35 (4) For bi-directional types with VR 10 V and less, the ID limit is doubled (5) VF = 3.5 V at IF = 25 A (uni-directional only) www.vishay.com 2 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com Document Number: 88367 Revision: 21-Oct-08 P4SMA Series Vishay General Semiconductor THERMAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER Thermal resistance, junction to ambient SYMBOL VALUE RJA 120 C/W RJL 30 C/W air (1) Thermal resistance, junction to leads UNIT Note: (1) Mounted on minimum recommended pad layout ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE P4SMA6.8A-E3/61 0.064 61 1800 7" diameter plastic tape and reel 0.064 5A 7500 13" diameter plastic tape and reel P4SMA6.8A-E3/5A (1) 0.064 61 1800 7" diameter plastic tape and reel P4SMA6.8AHE3/5A (1) 0.064 5A 7500 13" diameter plastic tape and reel P4SMA6.8AHE3/61 Note: (1) Automotive grade AEC Q101 qualified RATINGS AND CHARACTERISTICS CURVES (TA = 25 C unless otherwise noted) 150 Non-Repetitive Pulse Waveform shown in Fig. 3 TA = 25 C 10 1 0.2 x 0.2" (5.0 x 5.0 mm) Copper Pad Areas 0.1 0.1 s TJ = 25 C Pulse Width (td) is defined as the Point where the Peak Current decays to 50 % of IPPM tr = 10 s Peak Value IPPM 100 Half Value - IPP 2 IPPM 50 10/1000 s Waveform as defined by R.E.A. td 0 1.0 s 10 s 100 s 1.0 ms 10 ms 0 1.0 2.0 3.0 td - Pulse Width (s) t - Time (ms) Figure 1. Peak Pulse Power Rating Curve Figure 3. Pulse Waveform 100 4.0 10 000 CJ - Junction Capacitance (pF) Peak Pulse Power (PPP) or Current (IPP) Derating in Percentage, % P4SMA6.8A P4SMA91A P4SMA100A P4SMA220A IPPM - Peak Pulse Current, % IRSM PPPM - Peak Pulse Power (kW) 100 75 50 25 0 TJ = 25 C f = 1.0 MHz Vsig = 50 mVp-p Measured at Stand-Off Voltage VWM 1000 Uni-Directional 100 Bi-Directional 10 0 25 50 75 100 125 150 175 200 1 10 100 TJ - Initial Temperature (C) VBR - Breakdown Voltage (V) Figure 2. Pulse Power or Current vs. Initial Junction Temperature Figure 4. Typical Junction Capacitance Document Number: 88367 Revision: 21-Oct-08 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com 200 www.vishay.com 3 P4SMA Series Vishay General Semiconductor 200 Peak Forward Surge Current (A) Transient Thermal Impedance (C/W) 1000 100 10 1 0.001 TJ = TJ max. 8.3 ms Single Half Sine-Wave 100 50 10 0.01 0.1 1 10 100 1000 1 5 tp - Pulse Duration (s) 10 50 100 Number of Cycles at 60 Hz Figure 5. Typical Transient Thermal Impedance Figure 6. Maximum Non-Repetitive Forward Surge Current Uni-Directional Only PACKAGE OUTLINE DIMENSIONS in inches (millimeters) DO-214AC (SMA) Cathode Band Mounting Pad Layout 0.110 (2.79) 0.100 (2.54) 0.065 (1.65) 0.049 (1.25) 0.177 (4.50) 0.157 (3.99) 0.012 (0.305) 0.006 (0.152) 0.060 (1.52) MIN. 0.208 (5.28) REF. 0.090 (2.29) 0.078 (1.98) 0.060 (1.52) 0.030 (0.76) 0.074 (1.88) MAX. 0.066 (1.68) MIN. 0.008 (0.203) 0 (0) 0.208 (5.28) 0.194 (4.93) www.vishay.com 4 For technical questions within your region, please contact one of the following: PDD-Americas@vishay.com, PDD-Asia@vishay.com, PDD-Europe@vishay.com Document Number: 88367 Revision: 21-Oct-08 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000