Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Converter Power Modules: 18-36V & 36-75Vdc Input; 3.3V-15Vdc Output; 1-3.5A Output Current RoHS Compliant Features Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 3.5A Output current High efficiency - 86% at 5.0V full load (VIN=54 Vdc) Low output ripple and noise Small Size and low profile 15V (1A), 12V (1.25A), 5.0V (3A) and 3.3V (3.5A) 27.94mm x 24.38mm x 8.5mm Applications Wireless Networks Distributed power architectures Optical and Access Network Equipment Enterprise Networks Latest generation IC's (DSP, FPGA, ASIC) and Microprocessor powered applications Options Remote On/Off logic (positive or negative), pin optional for TH version (Suffix 1 or 4) Output voltage adjustment-Trim, pin optional for TH version (Suffix 9) Surface Mount/Tape and Reel (-SR Suffix) (1.10 x 0.96 x 0.335 in) Industry Standard pin-out: TH version is LW series compatible Surface mount (SMT) or Through hole (TH) Remote On/Off (optional pin on TH version) Output overcurrent/voltage protection Single Tightly regulated output Output voltage adjustment trim 10% Wide operating temperature range (-40C to 85C) Meets the voltage insulation requirements for ETSI 300-132-2 and complies with and is Licensed for Basic Insulation rating per EN 60950 CE mark meets the 2006/95/EC directive UL* 60950-1Recognized, CSA C22.2 No. 60950-1 rd 03 Certified, and VDE 0805: (IEC60950, 3 Edition) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Approved for Basic Insulation Description The SW/SC series power modules are isolated dc-dc converters that operate over a wide range of input voltage (VIN = 18 - 36Vdc for SC modules and VIN = 36 - 75Vdc for SW modules) and provide a single precisely regulated output. This series is a low cost, smaller size alternative to the existing LW/LAW/LC with enhanced performance parameters. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, typical efficiency of 86% for 5.0V/3A. Built-in filtering for both input and output minimizes the need for external filtering. This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS03-086 ver. 1.91 PDF name: sw001-002-003_series.pdf Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit SW VIN SC VIN -0.3 80 Vdc -0.3 50 All VIN, trans -0.3 100 Vdc All TA -40 85 C Storage Temperature All Tstg -55 125 C I/O Isolation Voltage (100% factory Hi-Pot tested) All 2250 Vdc Input Voltage (Continuous) Transient (100ms) Operating Ambient Temperature (see Thermal Considerations section) Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Device Symbol Min Typ Max Unit SW VIN 36 54 75 Vdc SC VIN 18 27 36 Vdc Maximum Input Current (VIN=0V to 75V, IO=IO, max) SW IIN,max 0.6 Adc (VIN=0V to 36V, IO=IO, max) SC IIN,max 1.2 Adc Inrush Transient All 2 0.05 As Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN=0V to 75V, IO= IOmax ; see Test configuration section) All 30 mAp-p Input Ripple Rejection (120Hz) All 50 dB EMC, EN55022 It 2 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fastacting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. LINEAGE POWER 2 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Electrical Specifications (continued) Parameter Output Voltage Set-point Device Symbol Min Typ Max Unit All VO, set -1.5 +1.5 % VO, set VO -3.0 +3.0 % VO, set VO, adj -10.0 +10.0 % VO, set 0.2 % VO, set (VIN=VIN,nom, IO=IO, max, TA=25C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range All Selected by external resistor Output Regulation 0.05 All 0.05 0.2 % VO, set All 1.00 % VO, set RMS (5Hz to 20MHz bandwidth) 5V, 3.3V 25 mVrms Peak-to-Peak (5Hz to 20MHz bandwidth) 5V, 3.3V 75 mVpk-pk RMS (5Hz to 20MHz bandwidth) 15V, 12V 35 mVrms Peak-to-Peak (5Hz to 20MHz bandwidth) 15V, 12V mVpk-pk Line (VIN=VIN, min to VIN, max) All Load (IO=IO, min to IO, max) Temperature (Tref=TA, min to TA, max) Output Ripple and Noise on nominal output Measured with 10uF Tantalum and 1uF ceramic (VIN=VIN, nom IO=80%IO, max TA=25C) 100 3.3V, 5V CO, max 0 1000 F 12V, 15V CO, max 0 220 F 15V Io 0 1.0 Adc 12V Io 0 1.25 Adc 5V Io 0 3.0 Adc 3.3V Io 0 3.5 Adc Output Current Limit Inception 15V IO, lim 1.1 Adc (Hiccup Mode) 12V IO, lim 1.4 Adc Adc External Capacitance Output Current Output Short-Circuit Current o VO 250 mV @ 25 C 5V IO, lim 3.2 4.2 3.3V IO, lim 3.7 Adc 15V IO, s/c 0.8 A rms 12V IO, s/c 1.2 A rms 5V IO, s/c 0.7 A rms 3.3V IO, s/c 1.5 A rms % SW (15V) 88.0 VIN=VIN, nom, TA=25C SW (12V) 87.0 % IO=IO, max, VO= VO, set SW (5.0V) 86.0 % SW (3.3V) 85.0 % Efficiency SC (12V) 85.0 SC (5.0V) 85.5 SC (3.3V) 85.5 Switching Frequency (Variable with Line & Load) VIN=VIN, nom and IO= IO, max All fsw 300 kHz VIN=VIN, nom and IO= 0.5 x IO, max All fsw 440 kHz LINEAGE POWER 3 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit All Vpk All ts 1.5 % VO, set 800 s Dynamic Load Response (Io/t=0.1A/s, VIN=VIN, nom, TA=25C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max: Peak Deviation Settling Time (Vo<10% peak deviation) Isolation Specifications Parameter Symbol Min Typ Max Unit Isolation Capacitance Ciso 65 pF Isolation Resistance Riso 10 M I/O Isolation Voltage All 2250 Vdc General Specifications Parameter Min Calculated MTBF (for SW003A0A91 in accordance with Lineage Power RIN: IO=80% of IO, max, TA=25C, airflow=1m/s) Weight LINEAGE POWER Typ Max 8,200,000 9.0 (0.32) Unit Hours g (oz.) 4 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit mA Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low - Remote On/Off Current All Ion/off 1.0 Logic Low - On/Off Voltage All Von/off -0.7 1.2 V Logic High Voltage - (Typ = Open Collector) All Von/off 5.8 15 V Logic High maximum allowable leakage current All Ion/off 50 A 20 50 ms 20 50 ms Turn-On Delay and Rise Times (IO=80% of IO, max, TA=25C) Case 1: On/Off input is set ON and then input power is applied (Tdelay = from instant at which VIN=VIN, min until VO = 10% of VO, set). Case 2: Input power is applied for at least 1 second and then On/Off input is set from OFF to ON (Tdelay = from instant at which VIN=VIN, min until VO = 10% of VO, set). All All Tdelay Case1 Tdelay Case2 T rise = time for VO to rise from 10% of VO, set to 90% of VO, set. All Trise 0.1 1 ms T rise = time for VO to rise from 10% of VO, set to 90% of VO, set with max ext capacitance All Trise 1.5 ms 3 % VO, set Output Voltage Overshoot (IO=80% of IO, max, VIN= 54V, TA=25C) 15V VO, limit 16.6 21.0 V 12V VO, limit 13.3 16.0 V 5.0V VO, limit 5.6 7.0 V 3.3V VO, limit 3.7 5.4 V Turn-on Threshold SW Vuv/on 33 36 V Turn-off Threshold SW Vuv/off 27.5 30.5 V Hysterisis SW Vhyst 2.5 V Turn-on Threshold SC Vuv/on 17 18 V Turn-off Threshold SC Vuv/off 13.5 14.5 V Hystersis SC Vhyst 3.0 V Output Overvoltage Protection Input Undervoltage Lockout LINEAGE POWER 5 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves EFFICIENCY (%) 84 82 80 78 V I = 36V V I = 54V V I = 75V 76 74 72 70 0 0.2 0.4 0.6 0.8 1 OUTPUT CURRENT, Io (A) Figure 1. Converter Efficiency versus Output Current. VO (V) (5V/div) 86 OUTPUT VOLTAGE 88 VON/OFF(V) (2V/div) 90 On/Off VOLTAGE, The following figures provide typical characteristics for the SW001A0C91 (15.0V, 1A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. TIME, t (5ms/div) Figure 4. Typical Start-Up Using Remote On/Off, negative logic version shown. 0.6 3.0 m/ s (600 f t ./ min.) 2.0 m/ s (400 f t ./ min.) 0.4 1.0 m/ s (200 f t ./ min.) Nat ural Convect ion 0.2 0.0 0 10 20 30 40 50 60 70 80 90 100 110 IO (A) (0.2A/div) 0.8 VO (V) (50mV/div), OUTPUT CURRENT, Io (A) 1.0 OUTPUT VOLTAGE, OUTPUTCURRENT 1.2 O TIME, t (1ms/div) AMBIENT TEMPERATURE, TA C TIME, t (1s/div) Figure 3. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (2.5V/div) Figure 5. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, Figure 2. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (500s/div) Figure 6. Typical Start-Up Output Voltage Rise Characteristic. 6 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) OUTPUT VOLTAGE 78 V I = 36V V I = 54V V I = 75V 76 74 72 70 0.0 0.2 0.4 0.6 0.8 1.0 1.2 OUTPUT CURRENT, Io (A) Figure 7. Converter Efficiency Vs Load at Vo= 12 V. 1.4 OUTPUT CURRENT, Io (A) 1.2 1.0 0.8 3.0 m/s (600 ft./min.) 2.0 m/s (400 ft./min.) 1.0 m/s (200 ft./min.) Natural Convection 0.6 0.4 0.2 0.0 0 10 20 30 40 50 60 70 80 90 100 110 VON/OFF(V) (2V/div) 80 On/Off VOLTAGE, 82 TIME, t (5ms/div) Figure 10. Typical Start-Up Using Remote On/Off, negative logic version shown. IO (A) (0.25A/div) EFFICIENCY (%) 84 OUTPUT VOLTAGE, OUTPUTCURRENT 86 VO (V) (50mV/div), 88 VO (V) (5V/div) The following figures provide typical characteristics for the SW001A2B91 (12.0V, 1.2A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (1s/div) Figure 9. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (2V/div) Figure 11. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (50mV/div) OUTPUT VOLTAGE, Figure 8. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (100s/div) Figure 12. Typical Start-Up Output Voltage Rise Characteristic. 7 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) The following figures provide typical characteristics for the SW003A0A91 (5.0V, 3A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. 80 78 V I = 36V V I = 54V V I = 75V 72 70 0 1 0.5 1.5 2 2.5 3 OUTPUT CURRENT, Io (A) Figure 13. Converter Efficiency Vs Load at Vo= 5V. OUTPUT CURRENT, Io (A) 4 3 2 3.0 m/ s (600 ft./min.) 2.0 m/ s (400 ft./min.) 1.0 m/ s (200 ft./min.) Natural Convection 1 0 0 10 20 30 40 50 60 70 80 90 100 TIME, t (5ms/div) Figure 16. Typical Start-Up Using Remote On/Off, negative logic version shown. 110 IO (A) (0.5A/div) 74 VO (V) (50mV/div), 76 OUTPUT VOLTAGE, OUTPUTCURRENT EFFICIENCY (%) 82 VO (V) (2V/div) 84 VON/OFF(V) (2V/div) 86 On/Off VOLTAGE, OUTPUT VOLTAGE 88 O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (1s/div) Figure 15. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (1V/div) Figure 17. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, Figure 14. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (100s/div) Figure 18. Typical Start-Up Output Voltage Rise Characteristic. 8 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) OUTPUT VOLTAGE 84 80 78 V I = 36V V I = 54V V I = 75V 76 74 72 70 1 1.5 2 2.5 3 3.5 OUTPUT CURRENT, Io (A) Figure 19. Converter Efficiency Vs Load. OUTPUT CURRENT, Io (A) 4 3 3.0m/ s (600ft /min) 2 2.0m/s (400ft/ min) 1.0m/s (200f t/min) 1 Natural Convection 0 0 10 20 30 40 50 60 70 TIME, t (1.0ms/div) Figure 22. Typical Start-Up Using Remote On/Off, negative logic version shown. 80 90 100 110 IO (A) (0.5A/div) 0.5 VO (V) (50mV/div), 0 OUTPUT VOLTAGE, OUTPUTCURRENT EFFICIENCY (%) 82 On/Off VOLTAGE, 86 VON/OFF(V) (2V/div) 88 VO (V) (1V/div) The following figures provide typical characteristics for the SW003A5F91 (3.3V, 3.5A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (2s/div) Figure 21. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (1V/div) Figure 23. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, Figure 20. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (100s/div) Figure 24. Typical Start-Up Output Voltage Rise Characteristic. 9 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) OUTPUT VOLTAGE 82 80 78 V I = 18V V I = 2 7V V I = 36 V 76 74 72 70 0.4 0.6 0.8 1.0 1.2 OUTPUT CURRENT, Io (A) Figure 25. Converter Efficiency Vs Load. Figure 28. Typical Start-Up Using Remote On/Off, negative logic version shown. 1.4 OUTPUT CURRENT, Io (A) 1.2 1.0 0 .8 3 .0 m/ s (6 0 0 f t ./ min.) 2 .0 m/ s (4 0 0 f t ./ min.) 1.0 m/ s (2 0 0 f t ./ min.) Nat ural Co nvect io n 0 .6 0 .4 0 .2 0 .0 0 10 20 30 40 50 60 70 TIME, t (5ms/div) 80 90 10 0 110 IO (A) (0.25A/div) 0.2 VO (V) (50mV/div), 0.0 OUTPUT VOLTAGE, OUTPUTCURRENT EFFICIENCY (%) 84 On/Off VOLTAGE, 86 VON/OFF(V) (2V/div) 88 VO (V) (5V/div) The following figures provide typical characteristics for the SC001A2B91 (12.0V, 1.2A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (1s/div) Figure 27. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (2V/div) Figure 29. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (50mV/div) OUTPUT VOLTAGE, Figure 26. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (100s/div) Figure 30. Typical Start-Up Output Voltage Rise Characteristic. 10 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) OUTPUT VOLTAGE 82 80 78 V I = 18 V V I = 2 7V V I = 36V 76 74 72 70 1 1.5 2 2 .5 3 OUTPUT CURRENT, Io (A) Figure 31. Converter Efficiency Vs Load. Figure 34. Typical Start-Up Using Remote On/Off, negative logic version shown. 3 .5 OUTPUT CURRENT, Io (A) 3 .0 2 .5 2 .0 3 .0 m/ s (6 0 0 f t ./ min.) 2 .0 m/ s (4 0 0 f t ./ min.) 1.0 m/ s (2 0 0 f t ./ min.) Nat ural Co nvect io n 1.5 1.0 0 .5 0 .0 0 10 20 30 40 50 60 70 TIME, t (5ms/div) 80 90 10 0 110 IO (A) (0. 5A/div) 0 .5 VO (V) (50mV/div), 0 OUTPUT VOLTAGE, OUTPUTCURRENT EFFICIENCY (%) 84 On/Off VOLTAGE, 86 VON/OFF(V) (2V/div) 88 VO (V) (2V/div) The following figures provide typical characteristics for the SC003A0A91 (5.0V, 3A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (1s/div) Figure 33. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (1V/div) Figure 35. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, Figure 32. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (100s/div) Figure 36. Typical Start-Up Output Voltage Rise Characteristic. 11 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Characteristic Curves (continued) OUTPUT VOLTAGE 82 80 78 V I = 18 V V I = 2 7V V I = 36V 76 74 72 70 1 1.5 2 2 .5 3 3 .5 OUTPUT CURRENT, Io (A) Figure 37. Converter Efficiency Vs Load. Figure 40. Typical Start-Up Using Remote On/Off, negative logic version shown. 4 .0 OUTPUT CURRENT, Io (A) 3 .5 3 .0 2 .5 3 .0 m/ s (6 0 0 f t ./ min.) 2 .0 m/ s (4 0 0 f t ./ min.) 1.0 m/ s (2 0 0 f t ./ min.) Nat ural Co nvect io n 2 .0 1.5 1.0 0 .5 0 .0 0 10 20 30 40 50 60 70 TIME, t (5ms/div) 80 90 10 0 110 IO (A) (0. 5A/div) 0 .5 VO (V) (50mV/div), 0 OUTPUT VOLTAGE, OUTPUTCURRENT EFFICIENCY (%) 84 On/Off VOLTAGE, 86 VON/OFF(V) (2V/div) 88 VO (V) (1V/div) The following figures provide typical characteristics for the SC003A5F91 (3.3V, 3.5A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. O TIME, t (1.0ms/div) AMBIENT TEMPERATURE, TA C TIME, t (2s/div) Figure 39. Typical Output Ripple and Noise, VIN=VIN, nom IO=80% of IO, max. LINEAGE POWER VO (V) (1V/div) Figure 41. Transient Response to Dynamic Load Change from 50% to 75% to 50% of full load. OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE, Figure 38. Derating Output Current versus Local Ambient Temperature and Airflow. TIME, t (50s/div) Figure 42. Typical Start-Up Output Voltage Rise Characteristic. 12 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Test Configurations Design Considerations CURRENT PROBE TO OSCILLOSCOPE The power module should be connected to a low ac-impedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 43, a 33F electrolytic capacitor (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. LTEST Vin+ BATTERY 12H CS 220F 33F E.S.R.<0.1 @ 20C 100kHz Vin- NOTE: Measure input reflected ripple current with a simulated source inductance (LTEST) of 12H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 43. Input Reflected Ripple Current Test Setup. COPPER STRIP VO (+) RESISTIVE LOAD 1uF . 10uF SCOPE V O (-) GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 44. Output Ripple and Noise Test Setup. Rdistribution Rcontact Rcontact Vin+ Rdistribution RLOAD VO Rcontact Rcontact Vin- Rdistribution Vout- NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 45. Output Voltage and Efficiency Test Setup. VO. IO Efficiency = LINEAGE POWER VIN. IIN x 100 % Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE 0805 (IEC60950, 3rd Edition). If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module's output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module), as required by the safety agencies, to verify that under a single fault, hazardous voltages do not appear at the module's output. Rdistribution Vout+ VIN Input Source Impedance Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. For input voltages exceeding -60 Vdc but less than or equal to -75 Vdc, these converters have been evaluated to the applicable requirements of BASIC INSULATION between secondary DC MAINS DISTRIBUTION input (classified as TNV-2 in Europe) and unearthed SELV outputs. The input to these units is to be provided with a maximum 3A time-delay fuse in the ungrounded lead. 13 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Feature Description Input Undervoltage Lockout Remote On/Off At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will only begin to operate once the input voltage is raised above the undervoltage lockout turn-on threshold, VUV/ON. Two remote on/off options are available. Positive logic turns the module on during a logic high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote On/Off, device code suffix "1", turns the module off during a logic high and on during a logic low. To maintain compatibility with LW series power modules the Remote On/Off pin is optional for the TH (through hole) version. Standard TH modules have no On/Off pin fitted. TH modules ordered with device code suffix "1" are negative logic with the On/Off pin fitted. The On/Off pin shall always be fitted on SMT versions. Vin+ Vout+ Once operating, the module will continue to operate until the input voltage is taken below the undervoltage turn-off threshold, VUV/OFF. Over Voltage Protection The output overvoltage protection consists of circuitry that internally clamps the output voltage. If a more accurate output overvoltage protection scheme is required then this should be implemented externally via use of the remote on/off pin. Output Voltage Programming Ion/off ON/OFF TRIM Von/off Vin- Vout- Trimming allows the user to increase or decrease the output voltage set point of the module. This is accomplished by connecting an external resistor between the TRIM pin and either the Vout+ pin or the Vout- pin. Note: Trim pin is optional on TH module version and always present on SMT versions. Trim Down - Decrease Output Voltage Figure 46. Circuit configuration for using Remote On/Off Implementation. To turn the power module on and off, the user must supply a switch (open collector or equivalent) to control the voltage (Von/off) between the ON/OFF terminal and the VIN(-) terminal. Logic low is 0V Von/off 1.2V. The maximum Ion/off during a logic low is 1mA, the switch should be maintain a logic low level whilst sinking this current. During a logic high, the typical Von/off generated by the module is 5.8V, and the maximum allowable leakage current at Von/off = 5.8V is 50A. If not using the remote on/off feature: For positive logic, leave the ON/OFF pin open. For negative logic, short the ON/OFF pin to VIN(-). By connecting an external resistor between the TRIM pin and Vout+ pin (Radj-down), the output voltage set point decreases (see figure 17). The following equation determines the external resistor value to obtain an output voltage change from Vo, nom to the desired Vo, adj: (Vo , adj - L) x G Radj - down = - H (Vo , nom - Vo , adj ) Note: Values for G, H, L and K are defined for each module version in the following table 1. Vin+ Vout+ Radj-down Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. The unit operates normally once the output current is brought back into its specified range. The average output current during hiccup is 10% IO, max. LINEAGE POWER ON/OFF TRIM Vin- RLOAD Vout- Figure 17. Circuit Configuration to Decrease Output Voltage. 14 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Trim Examples For SW003A0A, nominal 5.0V module. To trim module down to 4.90V: Feature Descriptions (continued) Trim Up - Increase Output Voltage By connecting an external resistor between the TRIM pin and Vout- pin (Radj-up), the output voltage set point increases (see figure 48). The following equation determines the external resistor value to obtain an output voltage change from Vo, nom to the desired Vo, adj: (4.9 - 2.5) x 5110 Radj - down = - 2050 (5.0 - 4.9) Radj - down = 120,590 GxL Radj - up = - H (Vo , adj - L - K ) Note: Values for G, H, L and K are defined for each module version in the following table 1. Vin+ Vout+ ON/OFF RLOAD TRIM Radj-up Vin- Vout- Figure 48. Circuit Configuration to Increase Output Voltage. Table 1. Trim Constants SW series Module G H K L Sx001A0C 10,000 5110 12.5 2.5 Sx001A2B 10,000 5110 9.5 2.5 Sx003A0A 5110 2050 2.5 2.5 Sx003A5F 5110 2050 0.8 2.5 The combination of the output voltage adjustment and the output voltage initial tolerance must not exceed the allowable trim range of 90% to 110% of the nominal output voltage as measured between the Vout+ and Vout- pins. The SW/SC power modules have a fixed current-limit set point. Therefore, as the output voltage is adjusted down, the available output power is reduced. LINEAGE POWER 15 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current C5 N/F Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The thermal reference point, Tref used in the specifications is shown in Figure 49. For reliable o operation this temperature should not exceed 120 C. L1 10uH C1 0.68uF C2 0.68uF C3 0.68uF VI(+) Vo + SW003A0A C4 4.7uF Polymer 5V @ 3A VI(-) Vo - Pulse P0354 CMC 1.17mH C6 2 x 56nF Figure 50. Suggested Configuration for EN55022 Class B. 90 80 70 60 EN 55022 Class B Conducted Average dBuV 50 40 Tref Figure 49. Tref Temperature Measurement Location. Level (dBV) 30 20 10 100K 500K 1M 5M 10M 30M Frequency(Hz) Heat Transfer via Convection Increased airflow over the module enhances the heat transfer via convection. Derating figures showing the maximum output current that can be delivered by each module versus local ambient temperature (TA) for natural convection and up to 3m/s (600 ft./min) are shown in the respective Characteristics Curves section. Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. EMC Considerations Figure 50 shows a suggested configuration to meet the conducted emission limits of EN55022 Class B. Figure 51. EMC signature using above filter, SW003A0A. For further information on designing for EMC compliance, please refer to the FLTR100V10 data sheet (FDS01-043EPS). Layout Considerations The SW/SC power module series are low profile in order to be used in fine pitch system card architectures. As such, component clearance between the bottom of the power module and the mounting board is limited. Avoid placing copper areas on the outer layer directly underneath the power module. Also avoid placing via interconnects underneath the power module. For additional layout guide-lines, refer to the FLTR100V10 data sheet. Notes: C1, C2, C3 and C6 are low impedance SMT ceramics. C4 is a low impedance polymer film type (Paktron CS4). Common Mode inductor is Pulse Engineering type P0354 1.17mH. LINEAGE POWER 16 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Mechanical Outline for SW/SC Surface-Mount Module Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [Unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 27.9 (1.1) Top View 24.4 (0.96) Side View 8.50 (0.335) MAX 2.54 (0.100) min stand-off height 0.5 (.020) max compliance Bottom View Pi Function 1 Vin + 2 Vin - 3 ON/OFF 4 Vout + 5 TRIM 6 Vout - LINEAGE POWER 7.62 (0.300) 4 1 5 12.70 (0.500) 2 6 3 2.0 (0.08) 20.32 (0.800) 3.8 (0.15) 20.32 (0.800) 10.16 (0.400) 17 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Mechanical Outline for SW/SC Through Hole Module Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [Unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 27.9 (1.1) Top View 24.4 (0.96) 0.635 (0.025) Side View 8.50 (0.335) MAX 4.95 4.70 (0.195) (0.185) O 0.95 MAX (0.0375) 0.762 (0.030) A Bottom View Pi Function 1 Vin + 2 Vin - 3 ON/OFF (Optional) 4 Vout + 5 TRIM (Optional) 6 Vout - 7.62 (0.300) A SECTION A-A 4 1 5 12.70 (0.500) 2 6 3 2.0 (0.08) 20.32 (0.800) 3.8 (0.15) 20.32 (0.800) 10.16 (0.400) Recommended Pad Layout for Surface Mount and Through Hole Module Dimensions are in millimeters and (inches). LINEAGE POWER 18 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [Unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 2.0 3.8 (0.08) (0.15) 20.32 (0.800) 10.16 (0.400) 6 3 Pin Function 1 Vin + 2 Vin - 3 ON/OFF 4 Vout + 5 TRIM 6 Vout - 12.70 (0.500) 2 5 1 7.62 (0.300) 20.32 (0.800) 4 IN 6 POSITIONS MINIMUM PAD O 1.9mm RECOMMENDED PAD O 2.8mm Surface Mount Pad Layout - Component side view 2.0 3.8 (0.08) (0.15) 20.32 (0.800) 3 Pin Function 1 Vin + 2 Vin - 3 ON/OFF (Optional) 4 Vout + 5 TRIM (Optional) 6 Vout - 12.70 (0.500) 2 7.62 (0.300) 10.16 (0.400) 6 5 1 20.32 (0.800) 4 IN 6 POSITIONS PAD O 3.5mm HOLE O1.2mm Through-Hole Pad Layout - Component side view LINEAGE POWER 19 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Packaging Details The SW001/003 series SMT versions are supplied in tape & reel as standard. Details of tape dimensions are shown below. Modules are shipped in quantities of 150 modules per reel. Tape Dimensions Dimensions are in millimeters and (inches). PICK POINT 4.00 (0.157) 32.00 (1.260) 9.14 (0.360) 19.05 (0.750) FEED 36.80 44.00 DIRECTION (1.450) (1.732) 40.40 (1.590) TOP COVER TAPE EMBOSSED CARRIER NOTE: CONFORMS TO EAI-481 REV. A STANDARD Reel Dimensions Outside Diameter: Inside Diameter: Tape Width: LINEAGE POWER 330.2 mm (13.00") 177.8 mm (7.00") 44.00 (1.732) 20 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current The SW/SC family of power modules is available for either Through-Hole (TH) or Surface Mount (SMT) soldering. Through-Hole Soldering Information The RoHS-compliant (Z codes) through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHScompliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHScompliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details. Surface Mount Information Pick and Place The SW/SC-SR series of DC-to-DC power converters use an open-frame construction and are designed for surface mount assembly within a fully automated manufacturing process. The SW/SC-SR series modules are designed to use the main magnetic component surface to allow for pick and place. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Even so, they have a relatively large mass when compared with conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 5mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 6.5mm. Oblong or oval nozzles up to 11 x 6 mm may also be used within the space available. For further information please contact your local Lineage Power Technical Sales Representative. Reflow Soldering Information These power modules are large mass, low thermal resistance devices and typically heat up slower than other SMT components. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when SMT soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. The surface mountable modules in the SW/SC family use our SMT technology called "Column Pin" (CP) connectors. Figure 53 shows the CP connector before and after reflow soldering onto the end-board assembly. Power Module Board 10.7 Insulator Solder Ball End assembly PCB 12.70 O6.5 NOZZLE. Note: All dimensions in mm. Figure 52. Pick and Place Location. Z Plane Height The `Z' plane height of the pick and place location is 7.50mm nominal with an RSS tolerance of +/-0.25 mm. LINEAGE POWER Figure 53. Column Pin Connector Before and After Reflow Soldering. The CP is constructed from a solid copper pin with an integral solder ball attached, which is composed of tin/lead (Sn63/Pb37) solder for non-Z codes, or Sn/Ag3.8/Cu0.7 (SAC) solder for -Z codes. The CP connector design is able to compensate for large amounts of co-planarity and still ensure a reliable SMT solder joint. Typically, the eutectic solder melts at 183oC (Sn/Pb solder) or 217-218 oC (SAC solder), wets the land, and subsequently wicks the device connection. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. 21 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Surface Mount Information (continued) There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. The recommended linear reflow profile using Sn/Pb solder is shown in Figure 54 and 55. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. 300 P eak Temp 235oC REFLOW TEMP (C) 250 Co o ling zo ne 1-4oCs -1 Heat zo ne max 4oCs -1 200 300 Per J-STD-020 Rev. C Peak Temp 260C 250 200 * Min. Time Above 235C 15 Seconds 150 Heating Zone 1C/Second Cooling Zone *Time Above 217C 60 Seconds 100 50 0 150 Reflow Time (Seconds) So ak zo ne 30-240s 100 50 Figure 56. Recommended linear reflow profile using Sn/Ag/Cu solder. Tlim above 205oC P reheat zo ne max 4oCs -1 MSL Rating 0 The SW/SC series SMT modules have a MSL rating of 1. REFLOW TIME (S) Figure 54. Recommended Reflow Profile for Sn/Pb solder. 240 MAX TEMP SOLDER (C) forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure. 56. Reflow Temp (C) Data Sheet October 5, 2009 235 230 225 220 215 210 205 200 0 10 20 30 40 50 60 TIME LIMIT (S) Figure 55. Time Limit, Tlim, Curve Above 205oC Reflow . Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40 C, < 90% relative humidity. Lead Free Soldering The -Z version SMT modules of the SW/SC series are lead-free (Pb-free) and RoHS compliant and are compatible in a Pb-free soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended LINEAGE POWER Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS). 22 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 2. Device Codes SW001A0C91Z SW001A2B SW001A2B9 SW001A2B91 SW001A2B91-33Z SW001A2B9Z SW001A2B91Z SW001A2B94 SW001A2B961-33BZ SW001A2B91-SR SW001A2B91-SRZ SW003A0A SW003A0A1 SW003A0A9 SW003A0A91 SW003A0A91Z SW003A0A94 SW003A0A94Z SW003A0A961 SW003A0A9Z SW003A0AZ SW003A0A91-SR SW003A0A91-SRZ SW003A0A94-SRZ SW003A5F SW003A5F91 SW003A5F91Z SW003A5F94 SW003A5F94Z SW003A5F961 SW003A5F91-SR SW003A5F91-SRZ SW003A5F94-SR SW003A5F94-SRZ Input Voltage 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc Output Voltage 15.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V Output Current 1.0A 1.2A 1.2A 1.2A 1.2A 1.2A 1.2A 1.2A 1.2A 1.2A 1.2A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.5A 3.5A 3.5A 3.5A 3.5A 3.5A 3.5A 3.5A 3.5A 3.5A Remote On/Off Logic Negative Not present Not present Negative Negative Not present Negative Positive Negative Negative Negative Not present Negative Not present Negative Negative Positive Positive Negative Not present Not present Negative Negative Positive Not present Negative Negative Positive Positive Negative Negative Negative Positive Positive Connector Type Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole SMT (tape & reel) SMT (tape & reel) Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole SMT (tape & reel) SMT (tape & reel) SMT (tape & reel) Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole SMT (tape & reel) SMT (tape & reel) SMT (tape & reel) SMT (tape & reel) CC109107331 108989637 108984576 108981788 CC109104568 CC109107348 CC109107356 108987314 CC109120623 108988787 108995718 108985276 108985284 108984790 108981549 CC109107380 108986928 CC109107397 108989901 CC109107372 CC109107364 108984550 109100468 109100476 108988275 108981556 CC109107406 108986902 CC109107414 108989620 108982059 109100492 108986910 CC109114526 SC001A2B91 SC001A2B91Z SC001A2B91-SR SC001A2B91-SRZ SC003A0A SC003A0A91 SC003A0A91Z SC003A0A94 SC003A0A94Z SC003A0A91-SR SC003A5F SC003A5F91 SC003A5F91Z SC003A5F91-SR SC003A5F91-SRZ 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 24 Vdc 12.0V 12.0V 12.0V 12.0V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 3.3V 3.3V 3.3V 3.3V 3.3V 1.2A 1.2A 1.2A 1.2A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.5A 3.5A 3.5A 3.5A 3.5A Negative Negative Negative Negative Not present Negative Negative Positive Positive Negative Not present Negative Negative Negative Negative Through-Hole Through-Hole SMT (tape & reel) SMT (tape & reel) Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole SMT (tape & reel) Through-Hole Through-Hole Through-Hole SMT (tape & reel) SMT (tape & reel) 108988267 CC109107298 108996468 CC109121976 108988291 108988283 CC109107307 108989967 CC109107315 108988325 108988300 108982034 CC109107323 108990644 109100435 Product codes LINEAGE POWER Comcodes 23 Data Sheet October 5, 2009 SW/SC001/003 Series DC-DC Power Module: 18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current Table 3. Device Options Option* Negative remote on/off logic (On/Off pin fitted) Positive remote on/off logic (On/Off pin fitted) Device Code Suffix** 1 4 Short Pins, 3.68 mm 0.25mm (0.145 in. 0.010 in.) Output Voltage Adjustment (Trim pin fitted) 6 9 Surface mount connections, SMT (Tape & Reel) -SR RoHS Compliant -Z * Please contact Lineage Power Sales Representative for availability of these options, samples, minimum order quantity and lead times. Legacy device codes may contain a -B option suffix to indicate 100% factory Hi-Pot tested to the isolation voltage specified in the Absolute Maximum Ratings table. The 100% Hi-Pot test is now applied to all device codes, with or without the -B option suffix. Existing comcodes for devices with the -B suffix are still valid; however, no new comcodes for devices containing the -B suffix will be created. ** When adding multiple options to the product code, add numerical suffix codes in the descending order. Either negative or positive logic (1 or 4), and output voltage adjustment (trim, 9) must be ordered on surface mount , SMT (-SR) device codes. Both the on/off pin and trim pin will be provided on all -SR device codes. Asia-Pacific Headquarters Tel: +65 6593 7211 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49 898 780 672 80 India Headquarters Tel: +91 80 28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: DS03-086 ver. 1.91 PDF name: sw001-002-003_series.pdf