No. SS2-MGG210-0100 (Rev.3) MagneW 3000 PLUS Smart Electromagnetic Flowmeter Converter (General, FM/CSA Nonincendive Approval) Model MGG14C OVERVIEW The MagneW 3000 PLUS electromagnetic flowmeter converter is a high-performance, and highly reliable flowmeter based on Yamatake's proven MagneW 3000 flow measurement technologies. The model MGG14C converter offers expanded flowrate and process measurement capabilities when used with the new range of MagneW 3000 PLUS detectors. FM / CSA nonincendive model is suitable for use in Class I / II / III, Division 2, Groups A, B, C, D, F, and G or non - hazardous location only. General model is suitable for use in non - hazardous location. (Remote converter) FEATURES Broader range of pitch in cable connection port * Allows incorporation of an all-purpose waterproofing gland the pitch of the cable connection port has been significantly increased. Liquid crystal display with backlighting (optional) * Backlit display eases reading in direct sunlight or in a dark room. * Simultaneously displays flow volume in percentage, actual flow volume and integrated flow volume. * Rotating display improves visibility of integral models mounted on pipes up to 90 degrees from standard. Compatibility * Enables combination of the remote electromagnetic flow converter with conventional detectors. Please talk to your Yamatake Corporation representative for details. Type of protection * Conforms CE marking and FM/CSA Nonincendive use in Class I / II / III, Division 2, Groups A, B, C, D, F, and G. Setting parameters by optional infrared touch sensor (Optional) * Allows safe setting, in severe environments, without opening the cover of the converter. * Prevent malfunctioning of the infrared touch sensor via special security feature. Easy changeover of integral and remote models * One converter case is used for both models. Specifications are subject to change without notice. -1- First issue: Feb. 1997 Rev.3: Jun. 2003 No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation APPLICATIONS FUNCTIONAL SPECIFICATIONS Pulp and Paper Type of protection Pulp liquids, chemicals, corrosive liquids, industrial water, wastewater, etc. Enclosure rating JIS C 0920 Waterproof model NEMA ICS6-110 TYPE4X IEC PUBL 529 IP66 Petroleum/petrochemical/chemicals Corrosive liquids, dyestuffs, chemicals, industrial water, waste water, etc. Hazardous areas certifications FM/CSA Nonincendive for Class I / II / III, Division 2, Groups A, B, C, D, F, and G. Public utilities Portable water, sewage systems, community drainage, human waste, sludge, sediment slurry, regulation of total effluent, etc. Measurable electrical conductivity (with detector size of 2.5 mm to 1100 mm (0.1 to 44 inches)) 3 S/cm or more Food Beer, milk, juice, wine, liquor, potable water, light, medium and high density fluids, industrial water, waste water, etc. Input signal Flow signal Flow proportional voltage signal from the detector Steel / nonferrous metals / ceramics Contact input (optional) Solid-state contact or no-voltage contact Alumina slurry, cooling water, industrial water, sea water, corrosive liquids, wastewater, etc. Output signal Machinery / electrical machinery Analog output 4 to 20mA DC Digital output DE Analog or digital output is selectable Contact output (optional) Open collector Contact capacity 30 V DC max. 200mA max. Pulse output (optional) Open collector Contact capacity 30 V DC max. 200mA max. Pulse frequency 2000 Hz max. Pulse width 0.3 to 999.9 ms Random setting or fixed at 50% of the duty Corrosive liquids, cooling water, circulating water, industrial water, waste water, etc. Construction Building material slurry, sediment slurry, cement slurry, industrial water, etc. Shipbuilding Sediment slurry, etc. Electric power Corrosive liquids, cooling water, industrial water, wastewater, etc. Gas Circulating water for air conditioning, etc. Analog output range/load resistance Without SFC communication 0.8mA to 22.4mA (-20% to +115%) Load resistance: 0 to 600 With SFC communication 3.2mA to 22.4mA (-5% to +115%) External power source for SFC communication 16 to 45 V DC Load resistance () = (External power source for communication - 8.5 V) / 0.025 With HART communication Load resistance: 250 minimum -2- Yamatake Corporation No. SS2-MGG210-0100 (Rev.3) Digital output range/load resistance Optional specifications With SFC communication 3.2mA to 22.4mA (-5% to +115%) External power source for SFC communication/ digital communication 16 to 45 V DC Load resistance () = (External power source for communication - 8.5 V) / 0.025 Display Indication by LCD with backlighting Main display 7-segment, 6 digits Sub display 16 digits, 2 lines Display contents Demonstrates three values simultaneously. * Flow volume in percentage * Actual flow volume * Totalized flow volume (when pulse output selected) Unit of flow indication Indication of volume flow : Indication of mass flow Indication of time m3, cm3, L, G, mG, kG, B : t, kg, g, lb : d, h, min, s Damping time Selection of main display and sub display Main display is selectable from the three values. Adjustable between 0.5 and 199.9 seconds Low flow cutoff Adjustable between 0 to 10% of setting range. Below selected value, output is driven to the zero flow rate signal level. Data setting device Setting by infrared ray touch sensor Infrared ray touch sensor: Four key switches Drop out Contact input function External 0% lock input Forces outputs (analog, digital, pulse) to the zero flow rate signal level. Activates by applying a contact input. Adjustable between 0 to 10% of setting range. Below selected value, pulse output is cut. Lightning protection 12 kV, 1000 A Equipped with the lightning arrester in the power source and external input and output terminals. External automatic zero adjustment input Adjusts zero-point. Activates by applying a contact input. Power failure External range switching input Switches two flow measurement ranges. Two measurement ranges * Dual range for normal directions * Normal / reverse range Activates by applying a contact input. An EEPROM retains data record of totalized value when pulse output is used (retention period approximately 10 years). Power supply 100 V AC 110 V AC 115 / 120 V AC 200 V AC 220 V AC 230 / 240 V AC 24 V DC +10% / -15% +10% / -15% +10% / -15% +10% / -15% +10% / -15% +10% / -15% +15% / -20% Built-in counter reset input (for pulse output model) Resets the totalized value of the built-in counter. Activates by applying a contact input. Contact output function Frequency Alarm output Outputs an alarm under the following conditions. * Self-diagnostic result * Empty detection * High / low limit alarm 50 / 60 Hz 5% Power consumption Within 13 W (17VA) Ambient temperature limits Range switching output * Outputs the status of flow range. * Large / small in dual range * Normal / Reverse -25 to +60C (-13 to 140F) Ambient humidity limits 5 to 100% RH Counter preset status output (for pulse output model) Activates when the counter reaches the preset value. -3- No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation Indication other than SI units The following non-SI units are available. Self-check result output Activates only when a self-diagnostic abnormality occurs. Empty detection output Activates only when an empty status is detected. Volume unit B (barrel), kG (kilo-gallon), G (gallon), mG (milli-gallon) High/low limit alarm output Activates when a high / low limit alarm occurs. Mass unit lb (pound) Two-stage flow rate alarm output (with two contact outputs) Activates when the first high / low limit alarm (H / L) occurs and the second high / low limit alarm (HH / LL) occurs. Empty pipe detection When the detector is empty, the analog output, digital output and pulse output are fixed at zero. Display is latched to zero. Pulse output Outputs the totalized value. Must be selected in case of using totalizer. Tag number on terminal box The designated tag numbers (maximum 16 characters) should be stamped on a plate, which is attached to the terminal box. One line can contain 8 characters, so if more characters must be written on two lines. Characters can be upper-case English letters, numbers and hyphens (-). For additional specifications, please contact your Yamatake representative. PERFORMANCE SPECIFICATIONS Accuracy Built-in counter function in combination with a detector Vs = Velocity of setting range Totalizer According to the pulse scale setting, it totals one count at a time, for normal and reverse flows. Vs (m/s) Totalizer with presetting function A preset value (target totalized value) can be set between 0000000000 and 9999999999. The counting method is same as that of the standard totalizer. Velocity during Velocity during measurement > Vs measurement < Vs x 40% x 40% 1.0 < Vs < 10 0.5% of rate 0.2% of Vs 0.1 < Vs < 1.0 (0.1/Vs+0.4)% of 0.4(0.1/Vs+0.4)% rate of Vs Normal/reverse flow difference totalizer The difference in flow volumes in the normal or reverse directions is calculated and counted. Vs = Velocity of setting range Vs (m/s) Traceability certificate The following three documents are provided. * Traceability System Chart * Traceability Certificate * Test Report Velocity during Velocity during measurement > Vs measurement < Vs x 20% x 20% 1.0 < Vs < 10 0.5% of rate 0.1% of Vs 0.1 < Vs < 1.0 (0.1/Vs+0.4)% of 0.2(0.1/Vs+0.4)% rate of Vs Vs = Velocity of setting range Tropicalization treatment Protects the electromagnetic flow meter in harsh environments during transportation and/or storage. The following treatments are applied. * Corrosion protection * Moisture prevention * Mildew proofing Vs (m/s) Velocity during Velocity during measurement > Vs measurement < Vs x 50% x 50% 1.0 < Vs < 10 1.0% of rate 0.5% of Vs 0.1 < Vs < 1.0 (0.2/Vs+0.8)% of (0.1/Vs+0.4)% of rate Vs -4- Yamatake Corporation No. SS2-MGG210-0100 (Rev.3) PHYSICAL SPECIFICATION (Integral model) Converter Detector Housing material Aluminum alloy Finish Standard Baked acryl paint Signal processing circuit C Power supply Corrosion-resistant Baked acryl paint Excitation circuit Corrosion-proof Baked epoxy paint Color Light beige (Munsell 4Y7.2/1.3) Non-hazardous or division 2 location Display cover material (Remote model) Tempered glass, 5 mm thick Detector Converter Weight SA 3.7 kg (8.2 lb) Exciting coil A A C C INSTALLATION B Electrodes Electrodes Electrical Connection Power supply SB X Shield X Y FM/CSA Nonincendive 1/2 NPT internal threads Non-hazardous or division 2 location Y Non-hazardous or division 2 location Configuration #1 General G1/2 (PF1/2) internal threads CM20 internal threads, Pg 13.5 internal threads - Preferred for 2.5 mm to 10 mm detectors to minimize noise A Mounting C Remote type Wall mounting, 2-inch pipe mounting B X Grounding Y Resistance less than 100 Non-hazardous or division 2 location A C B Power supply X Y Non-hazardous or division 2 location Configuration #2 For FM/CSA Nonincendive model This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, Class II, Division 2, Groups F and G; Class III, Division 2. B A C CAUTION B X Power supply and internal voltage of ordinary equipment to the earth shall not exceed 250 V AC 50/60 Hz, 250 V DC in case of normal / fault conditions. Y Non-hazardous or division 2 location Configuration #3 -5- A C B Power supply X Y Non-hazardous or division 2 location No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation MODEL SELECTION Converter Model MGG14C - I II III IV - V VI VII VIII - Y / Options (Some options can be selected per each model.) Option "Y" must be specified for Yamatake version Basic model no. Selections Optional selections MGG14C I Power supply 100 V AC, 50/60 Hz A 110 V AC, 50/60 Hz B 115/120 V AC, 50/60 Hz C 200 V AC, 50/60 Hz D 220 V AC, 50/60 Hz E 230/240 V AC, 50/60 Hz F 24 V DC, noise filter 50 Hz G 24 V DC, noise filter 60 Hz H Output signal / Com- Volume flow 4 to 20mA DC output / without communication A munication Volume flow 4 to 20mA DC output / with communication (Note 1) B Volume flow DE output / with communication (Note 1) C Volume flow 4 to 20mADC output / with HART communication H Electrical connection / G1/2 internal thread / without watertight gland 1 Watertight gland G1/2 internal thread / with brass (Ni-plated) watertight gland 2 G1/2 internal thread / with plastic watertight gland 3 1/2NPT internal thread / without watertight gland (Note 2) 4 CM20 internal thread / without watertight gland 5 Pg13.5 internal thread / without watertight gland 6 G1/2 internal thread / with SUS304 watertight gland 7 Installation / Wiring Integral type Horizontal piping mounting / upstream side direction Horizontal piping mounting / downstream side Horizontal piping mounting / left side viewed from upstream Horizontal piping mounting / right side viewed from upstream Vertical piping mounting / downstream side (flow direction: downstream to upstream) Remote type Wall mounting with standard bracket 2-inch pipe mounting with standard bracket II III IV V Finish VI Display with data setting device VII Contact inputs / outputs VIII Style code Options - Standard finish Corrosion-resistant finish Corrosion-proof finish None Main display: instantaneous indication of flow volume in % Main display: instantaneous indication of actual flow volume Main display: indication of integrated flow volume (Note 3) None 1 input and 1 output (ranging function, warning for contact input/output, etc.) 2 inputs (ranging function, external automatic zero adjustment input, etc.) 2 outputs (ranging function, warning for contact outputs.) None Yamatake version (must be selected) Empty pipe detection function Pulse output (open collector) Traceability certificate for converter Indication other than SI units Attachment of the TAG number to the terminal box for converter (Note 4) Tropical treatment Note) Y A B C H J E 1. In case of this code, it is necessary to supply 16 to 45 V DC on 4 to 20mA DC signal line. 2. Must be selected for FM / CSA NI approval. 3. In case of this code, option "B" must be selected. 4. Must be selected for Tag no. requirement -6- A B C D E G H X 1 2 X A B C X 1 2 3 X Yamatake Corporation No. SS2-MGG210-0100 (Rev.3) DIMENSIONS All dimensions are in millimeters, dimensions in brackets ( ) are in inches (inch). Wall mounting [Unit: mm (inch)] (5.04) (5.91) (0.13) (0.55) (0.61) (3.23) (8.50) (9.76) (5.12) (4.33) (1.18)(1.34) (4.06) (0.98) (0.98) (0.98) (0.98) 2-inch pipe mounting [Unit: mm (inch)] (5.04) (5.91) (3.23) (8.50) (5.12) (0.55) (1.18) (1.34) (4.06) (0.98) (0.59) (1.74) -7- No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation Integral type [Unit: mm (inch)] (8.50) (5.04) (3.23) (5.12) (6.26) (0.98) (0.98) (0.98) (0.98) (1.34) Note) The weight of an integral detector is 100 g less than the weight of remote detectors. Savemation Saving through Automation Totate international Building 2-12-19 Shibuya Shibuya-ku, Tokyo 150-8316 Japan Tel : 81-3-3486-2310 Fax : 81-3-3486-2593 -8This has been printed on recycled paper. http://www.yamatake.com/