Specifications are subject to change without notice. - 1 - First issue: Feb. 1997 Rev.3: Jun. 2003
No. SS2-MGG210-0100 (Rev.3)
MagneW 3000 PLUS
Smart Electromagnetic Flowmeter
Converter
(General, FM/CSA Nonincendive Approval)
Model MGG14C
(Remote converter)
OVERVIEW
The MagneW 3000 PLUS electromagnetic flow-
meter converter is a high-performance, and
highly reliable flowmeter based on Yamatake's
proven MagneW 3000 flow measurement tech-
nologies. The model MGG14C converter offers
expanded flowrate and process measurement
capabilities when used with the new range of
MagneW 3000 PLUS detectors.
FM / CSA nonincendive model is suitable for
use in Class I / II / III, Division 2, Groups A, B,
C, D, F, and G or non - hazardous location only.
General model is suitable for use in non - haz-
ardous location.
FEATURES
Liquid crystal display with backlighting
(optional)
Backlit display eases reading in direct sunlight
or in a dark room.
Simultaneously displays flow volume in per-
centage, actual flow volume and integrated
flow volume.
Rotating display improves visibility of integral
models mounted on pipes up to 90 degrees
from standard.
Setting parameters by optional infrared
touch sensor (Optional)
Allows safe setting, in severe environments,
without opening the cover of the converter.
Prevent malfunctioning of the infrared touch
sensor via special security feature.
Easy changeover of integral and remote
models
One converter case is used for both models.
Broader range of pitch in cable connec-
tion port
Allows incorporation of an all-purpose water-
proofing gland the pitch of the cable connec-
tion port has been significantly increased.
Compatibility
Enables combination of the remote electromag-
netic flow converter with conventional detec-
tors. Please talk to your Yamatake Corporation
representative for details.
Type of protection
Conforms CE marking and FM/CSA Nonin-
cendive use in Class I / II / III, Division 2,
Groups A, B, C, D, F, and G.
No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation
- 2 -
APPLICATIONS
Pulp and Paper
Pulp liquids, chemicals, corrosive liquids, industrial
water, wastewater , etc.
Petroleum/petrochemical/chemicals
Corrosive liquids, dyestuffs, chemicals, industrial
water, waste water, etc.
Public utilities
Portable water, sewage systems, community drain-
age, human waste, sludge, sediment slurry, regulation
of total effluent, etc.
Food
Beer, milk, juice, wine, liquor, potable water, light,
medium and high density fluids, industrial water,
waste water, etc.
Steel / nonferrous metals / ceramics
Alumina slurry, cooling water, industrial water, sea
water, corrosive liquids, wastewater, etc.
Machinery / electrical machinery
Corrosive liquids, cooling water, circulating water,
industrial water, waste water, etc.
Construction
Building material slurry, sediment slurry, cement
slurry, industrial water, etc.
Shipbuilding
Sediment slurry, etc.
Electric power
Corrosive liquids, cooling water, industrial water,
wastewater, etc.
Gas
Circulating water for air conditioning, etc.
FUNCTIONAL SPECIFICATIONS
Type of protection
Enclosure rating
JIS C 0920 Waterproof model
NEMA ICS6-110 TYPE4X
IEC PUBL 529 IP66
Hazardous areas certifications
FM/CSA Nonincendive for Class I / II / III, Divi-
sion 2, Groups A, B, C, D, F, and G.
Measurable electrical conductivity
(with detector size of 2.5 mm to 1100 mm (0.1 to 44
inches))
3 µS/cm or more
Input signal
Flow signal
Flow proportional voltage signal from the detector
Contact input (optional)
Solid-state contact or no-voltage contact
Output signal
Analog output
4 to 20mA DC
Digital output
DE
Analog or digital output is selectable
Contact output (optional)
Open collector
Contact capacity
30 V DC max.
200mA max.
Pulse output (optional)
Open collector
Contact capacity
30 V DC max.
200mA max.
Pulse frequency
2000 Hz max.
Pulse width
0.3 to 999.9 ms
Random setting or fixed at 50% of the duty
Analog output range/load resistance
Without SFC communication
0.8mA to 22.4mA (-20% to +115%)
Load resistance: 0 to 600
With SFC communication
3.2mA to 22.4mA (-5% to +115%)
External power source for SFC communication 16
to 45 V DC
Load resistance () =
(External power source for communicatio n - 8.5 V)
/ 0.025
With HART communication
Load resistance: 250 minimum
Yamatake Corporation No. SS2-MGG210-0100 (Rev.3)
- 3 -
Digital output range/load resistance
With SFC communication
3.2mA to 22.4mA (-5% to +115%)
External power source for SFC communication/
digital communication 16 to 45 V DC
Load resistance () =
(External power source for communication - 8.5 V)
/ 0.025
Unit of flow indication
Indication of volume flow: m3, L, cm3, G, mG, kG,
B
Indication of mass flow : t, kg, g, lb
Indication of time : d, h, min, s
Damping time
Adjustable between 0.5 and 199.9 seconds
Low flow cutoff
Adjustable between 0 to 10% of setting range.
Below selected value, output is driven to the zero
flow rate signal level.
Drop out
Adjustable between 0 to 10% of setting range.
Below selected value, pulse output is cut.
Lightning protection
12 kV, 100 0 A
Equipped with the lightning arrester in the power
source and external input and output terminals.
Power failure
An EEPROM retains data record of totalized value
when pulse output is used (retention period approxi-
mately 10 years).
Power supply
100 V AC +10% / -15%
110 V AC +10% / -15%
115 / 120 V AC +10% / -15%
200 V AC +10% / -15%
220 V AC +10% / -15%
230 / 240 V AC +10% / -15%
24 V DC +15% / -20%
Frequency
50 / 60 Hz ±5%
Power consumption
Within 13 W (17VA)
Ambient temperature limits
-25 to +60°C (-13 to 140°F)
Ambient humidity limits
5 to 100% RH
Optional specifications
Display Indication by LCD with backlighting
Main display
7-segment, 6 digits
Sub display
16 digits, 2 lines
Display contents
Demonstrates three values simultaneously.
Flow volume in percentage
Actual flow volume
Totalized flow volume (when pulse output
selected)
Selection of main display and sub display
Main display is selectable from the three values.
Data setting device
Setting by infrared ray touch sensor
Infrared ray touch sensor: Four key switches
Contact input function
External 0% lock input
Forces outputs (analog, digital, pulse) to the zero
flow rate signal level.
Activates by applying a contact input.
External automatic zero adjustment input
Adjusts zero-point.
Activates by applying a contact input.
External range switching input
Switches two flow measurement ranges.
Two measurement ranges
Dual range for normal directions
Normal / reverse range
Activates by applying a contact input.
Built-in counter reset input (for pulse out-
put model)
Resets the totalized value of the built-in counter.
Activates by applying a contact input.
Contact output function
Alarm output
Outputs an alarm under the following conditions.
Self-diagnostic result
Empty detection
High / low limit alarm
Range switching output
Outputs the status of flow range.
Large / small in dual range
Normal / Reverse
Counter preset status output (for pulse
output model)
Activates when the counter reaches the preset
value.
No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation
- 4 -
Self-check result output
Activates only when a self-diagnostic abnormal-
ity occurs.
Empty detection output
Activates only when an empty status is detected.
High/low limit alarm output
Activates when a high / low limit alarm occurs.
Two-stage flow rate alarm output (with
two contact outputs)
Activates when the first high / low limit alarm (H
/ L) occurs and the second high / low limit alarm
(HH / LL) occurs.
Empty pipe detection
When the detector is empty, the analog output, digi-
tal output and pulse output are fixed at zero. Dis-
play is latched to zero.
Pulse output
Outputs the totalized value.
Must be selected in case of using totalizer.
Built-in counter function
Totalizer
According to the pulse scale setting, it totals one
count at a time, for normal and reverse flows.
Totalizer with presetting function
A preset value (target totalized value) can be set
between 0000000000 and 9999999999. The
counting method is same as that of the standard
totalizer.
Normal/reverse flow difference totalizer
The difference in flow volumes in the normal or
reverse directions is calculated and counted.
Traceability certificate
The following three documents are provided.
Traceability System Chart
Traceability Certificate
•Test Report
Tropicalization treatment
Protects the electromagnetic flow meter in harsh
environments during transportation and/or storage.
The following treatments are applied.
Corrosion protection
Moisture prevention
Mildew proofing
Indication other than SI units
The following non-SI units are available.
Volume unit
B (barrel), kG (kilo-gallon), G (gallon), mG
(milli-gallon)
Mass unit
lb (pound)
Tag number on terminal box
The designated tag numbers (maximum 16 charac-
ters) should be stamped on a plate, which is
attached to the terminal box. One line can contain 8
characters, so if more characters must be written on
two lines.
Characters can be upper-case English letters, num-
bers and hyphens (-).
For additional specifications, please contact your
Yamatake representative.
PERFORMANCE SPECIFICATIONS
Accuracy
in combination with a detector
<Size 2.5 to 15 mm (0.1 to 1/2 inch)>
Vs = Velocity of setting range
<Size 25 to 600 mm (1 to 24 inches)>
Vs = Velocity of setting range
<Size 700 to 1100 mm (28 to 44 inches)>
Vs = Velocity of setting range
Vs (m/s) Velocity during
measurement > Vs
× 40%
Velocity during
measurement < Vs
× 40%
1.0 < Vs < 10 ±0.5% of rate ±0.2% of Vs
0.1 < Vs < 1.0 ±(0.1/Vs +0.4)% of
rate ±0.4(0.1/Vs+0.4)%
of Vs
Vs (m/s) Velocity during
measurement > Vs
× 20%
Velocity during
measurement < Vs
× 20%
1.0 < Vs < 10 ±0.5% of rate ±0.1% of Vs
0.1 < Vs < 1.0 ±(0.1/Vs+0.4)% of
rate ±0.2(0.1/Vs+0.4)%
of Vs
Vs (m/s) Velocity during
measurement > Vs
× 50%
Velocity during
measurement < Vs
× 50%
1.0 < Vs < 10 ±1.0% of rate ±0.5% of Vs
0.1 < Vs < 1.0 ±(0.2/Vs+0.8)% of
rate (0.1/Vs+0.4)% of
Vs
Yamatake Corporation No. SS2-MGG210-0100 (Rev.3)
- 5 -
PHYSICAL SPECIFICATION
Housing material
Aluminum alloy
Finish
Standard
Baked acryl paint
Corrosion-resistant
Baked acryl paint
Corrosion-proof
Baked epoxy paint
Color
Light beige (Munsell 4Y7.2/1.3)
Display cover material
Tempered glass, 5 mm thick
Weight
3.7 kg (8.2 lb)
INSTALLATION
Electrical Connection
FM/CSA Nonincendive
1/2 NPT internal threads
General
G1/2 (PF1/2) internal threads CM20 internal
threads, Pg 13.5 internal threads
Mounting
Remote type
Wall mounting, 2-inch pipe mounting
Grounding
Resistance less than 100
For FM/CSA Nonincendive model
This equipment is suitable for use in Class I, Division
2, Groups A, B, C and D, Class II, Division 2,
Groups F and G; Class III, Division 2.
CAUTION
Power supply and internal voltage of ordinary equip-
ment to the earth shall not exceed 250 V AC 50/60
Hz, 250 V DC in case of normal / fault conditions.
(Integral model)
(Remote model)
Detector Converter
Signal
processing
circuit
Excitation
circuit
Power
supply
Non-hazardous or division 2 location
C
Electrodes
Electrodes
Exciting coil
Detector
A
C
B
X
Y
SA
A
C
B
SB
X
Y
Converter
Shield
Power
supply
Non-hazardous or division 2 location Non-hazardous or division 2 location
Non-hazardous or division 2 location Non-hazardous or division 2 location
A
C
B
X
Y
A
C
B
X
Y
Power
supply
Configuration #1
- Preferred for 2.5 mm to 10 mm detectors to minimize noise
Configuration #2
Non-hazardous or division 2 location Non-hazardous or division 2 location
A
C
B
X
Y
A
C
B
X
Y
Power
supply
Configuration #3
No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation
- 6 -
MODEL SELECTION
Converter
Model MGG14C - I II III IV - V VI VII VIII - Y / Options (Some options can be selected per each model.)
Option “Y” must be specified for Yamatake version
Basic model no. Selections Optional selections
Note) 1. In case of this code, it is necessary to supply 16 to 45 V DC on 4 to 20mA DC signal line.
2. Must be selected for FM / CSA NI approval.
3. In case of this code, option “B” must be selected.
4. Must be selected for Tag no. requirement
MGG14C -
I Power supply 100 V AC, 50/60 Hz A
110 V AC, 50/60 Hz B
115/120 V AC, 50/60 Hz C
200 V AC, 50/60 Hz D
220 V AC, 50/60 Hz E
230/240 V AC, 50/60 Hz F
24 V DC, noise filter 50 Hz G
24 V DC, noise filter 60 Hz H
II Output signal / Com-
munication Volume flow 4 to 20mA DC output / without communication A
Volume flow 4 to 20mA DC output / with communication (Note 1) B
Volume flow DE output / with communication (Note 1) C
Vo lum e flow 4 to 20mADC output / with HART comm unication
H
III Electrical connection /
Watertight gland G1/2 internal thread / without watertight gland 1
G1/2 internal thread / with brass (Ni-plated) watertight gland 2
G1/2 internal thread / with plastic watertight gland 3
1/2NPT internal thread / without watertight gland (Note 2) 4
CM20 internal thread / without watertight gland 5
Pg13.5 internal thread / without watertight gland 6
G1/2 internal thread / with SUS304 watertight gland 7
IV Installation / Wiring
direction Integral type Horizontal piping mounting / upstream side A
Horizontal piping mounting / downstream side B
Horizontal piping mounting / left side viewed from upstream C
Horizontal piping moun ting / right side viewed from upstream D
Vertical piping mounting / downstream s ide (flow dir ection: down -
stream to upstream) E
Remote type Wall mounting with standard bracket G
2-inch pipe mounting with standard bracket H
V Finish Standard finish X
Corrosion-resistant finish 1
Corrosion-proof finish 2
VI Display with data set-
ting device None X
Main display: instantaneous indication of flow volume in % A
Main display: instantaneous indication of actual flow volume B
Main display: indication of integrated flow volume (Note 3) C
VII Contact inputs / out-
puts None X
1 input and 1 output (ranging function, warning for contact input/output, etc.) 1
2 inputs (ranging function, external au tomatic zero adjustment input, etc.) 2
2 outputs (ranging function, warning for contact outputs.) 3
VIII Style code None X
Options
Yamatake version (must be selected) Y
Empty pipe detectio n fu nctio n A
Pulse output (open collector) B
Traceability certificate for converter C
Indication other than SI units H
Attachment of the TAG number to the terminal box for converter (Note 4) J
T ropical treatment E
Yamatake Corporation No. SS2-MGG210-0100 (Rev.3)
- 7 -
DIMENSIONS
All dimensions are in millimeters, dimensions in brackets ( ) are in inches (inch).
Wall mounting [Unit: mm (inch)]
2-inch pipe mounting [Unit: mm (inch)]
(0.13) (5.04) (5.91)
(4.33) (0.55)
(9.76)
(8.50)
(5.12)
(3.23)
(0.61)
(1.34)
(1.18)
(0.98)(0.98)(0.98)(0.98)
(4.06)
(5.04)
(1.74)
(4.06)
(0.59) (8.50)
(5.12)(3.23)
(0.98)
(1.34)(1.18)
(5.91) (0.55)
No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation
- 8 -
Integral type [Unit: mm (inch)]
Note) The weight of an integral detector is 100 g less than the weight of remote detectors.
(5.04)
(1.34)
(0.98) (0.98) (0.98) (0.98)
(3.23)
(8.50)
(5.12)
(6.26)
Totate international Building
2-12-19 Shibuya
Shibuya-ku, Tokyo 150-8316
Japan
Tel :
Fax : 81-3-3486-2310
81-3-3486-2593
This has been printed on recycled paper. http://www.yamatake.com/
Savemation