HRS1K(H) Relay 1.COIL DATA 1-1.Nominal Voltage 1-2.Coil Resistance 1-3.Operate Voltage 1-4.Release Voltage 1-5.Nominal Power Consumption 3 VDC to 24 VDC Refer to Table 1 Refer to Table 1 Refer to Table 1 200 to 360 mW 2.CONTACT DATA 2-1.Contact Arrangement 2-2.Contact Material 2-3.Contact Rating 2-4.Max. Switching Voltage 2-5.Max. Switching Current 2-6.Max. Switching Power 2-7.Contact Resistance ( Initial ) Electrical 2-8.Life Expectancy Mechanical 1 Form C AuAg 1A 24 VDC / 120VAC 30 VDC / 120 VAC 2A 120 VA , 24W 100 m|. at 6 VDC 1A 100,000 operations at nominal load 10,000,000 operations 3.GENERAL DATA Min.100M| at 500 VDC 1,000VAC , 1min between open contact 1,500VAC , 1min between contact and coil Max. 5ms Max. 5ms -25 to +55 ae 10G 10 - 55 Hz , Amplitude 1.5mm 4 gr. UL/ NO. E164730 CSA NO. LR109368 3-1.Insulation Resistance 3-2.Dielectric Strength 3-3.Operate Time 3-4.Release Time 3-5.Temperature Range 3-6.Shock Resistance 3-7.Vibration Resistance 3-8.Weight 3-9.Safety Standard 4.DIMENSIONS ( in mm ) 5.ORDERING CODE HRS1K | | | | | | | | H| | | | | | S | | DC5V |_____ |____ _________ NOMINAL VOLTAGE: DC3V , DC5V , DC6V , DC9V , DC12V , DC24V ENCLOSURE S ----WASHABLE |_____ ________ _________ COIL NIL ---- STANDARD TYPE H ------- HIGH SENSITIVE TYPE |_____ ________ _________ _________ TYPE 6.COIL DATA CHART COIL NOMINAL VDC COIL RESISTANCE | +/- 10% OPERATE VOLTAGE VDC RELEASE VOLTAGE VDC HRS1K-S DC3V 3 25 2.25 0.30 HRS1K-S DC5V HRS1K-S DC6V HRS1K-S DC9V 5 6 9 70 100 220 3.75 4.50 6.75 0.50 0.60 0.90 HRS1K-S DC12V HRS1K-S DC24V 12 24 400 1600 9.00 18.00 1.20 2.40 HRS1KH-S DC3V HRS1KH-S DC5V HRS1KH-S DC6V 3 5 6 45 120 180 2.25 3.75 4.50 0.30 0.50 0.60 HRS1KH-S DC9V HRS1KH-S DC12V 9 12 400 700 6.75 9.00 0.90 1.20 HRS1KH-S DC24V 24 2800 18.00 2.40 ORDERING CODE Table 1 7.HRS1K(H) CHARACTERISTIC DATA COIL NOMINAL mW 360 200