GP1FAV31TK0F
GP1FAV31TK0F
Notice The content of data sheet is subject to change without prior notice.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Sheet No.: E2-A00601EN
Date Dec.01.2006
©SHARP Corporation
Fiber Optic Transmitter
Square connector
With mounting hole
With shutter
Applications
AV equipment
(DVD, CD, MD players etc.)
Features
1. Fiber optic transmitter
(Receiver : GP1FAV31RK0F)
2. Square connector (JEITA RC-5720B)
3. With mounting hole
4. With shutter function
5. Supply voltage : 3 V
6. Transfer rate : 15.5 Mb/s
Description
GP1FAV31TK0F has a built-in LED with a
peak light emission wavelength of 660 nm and
the associated drive IC, and the input is TTL
level compatible.
Agency approvals/Compliance
1. Compliant with JEITA RC-5720B and CP1201
2. Compliant with RoHS directive (2002/95/EC)
1
GP1FAV31TK0F
Outline Dimensions (Unit: mm)
Sheet No.: E2-A00601EN
(Lead root)
[1]
[2]
(Lead root)
Example of mounting drawing from solder side.
Unspecified tolerance ± 0.1
Production year
(Last digit of production year)
Production month
Model Number
Jan to Sep: 1 - 9
10 Oct: X
11 Nov: Y
12 Dec: Z
3T1
[2]Portion marking
φ2.3 ± 0.1
counterbore
φ4
Pin Arrangement
V
in
V
cc
GND
*1
Internal Equivalent Circuit
DRIVER IC
LED
1) The connector joint area complies with the square connector JEITA RC-5720B.
2) [1] portion : “S” mark, [2] portion : Model No. and date code shall be indicated.
3) Unspecified tolerance are ± 0.3
4) Since there are other products which has a different fixing pin shape,
please make sure to confirm reference mounting drawing for this device.
*1
Input conditions of V
in
terminal are designed to conform to TTL and CMOS.
It is recommended that the output of TTL and high speed CMOS be used in the
input for V
in
terminal.
Symbol Description Material
A Holder PBT (Color : Black)
B Shutter PBT (Color : Black)
C Fixing pin PBT (Color : Black)
D Lead pin Cu Alloy (SnCu plating)
Product mass : approx. 2 g
2
GP1FAV31TK0F
Absolute Maximum Ratings
*1 Solder at a position more than 1.6 mm away from the base of the lead terminal. Reflow is not available.
*2 Do not contact top of soldering iron to lead terminal directly.
Recommended Operating Conditions
Electro-optical Characteristics
Sheet No.: E2-A00601EN
Parameter Symbol Rating Unit Remark
Supply voltage
VCC -0.5 to +7.0 V
Input voltage
Vin -05. to VCC+0.5 V
Operating temperature
Topr -20 to +70 °C
Storage temperature
Tstg -30 to +80 °C
260
°C6 s or less/time up to 2 times.
4 s or less/time up to 1 time.
Soldering by hand at each terminal. *2
Soldering temperature *1
Tsol
380
(Ta = 25 °C, VCC = 3V)
Parameter Symbol MIN. TYP. MAX. Unit Remark
Supply voltage
VCC 2.7 3.0 5.25 V
Operating transfer rate T - - 15.5 Mb/s NRZ signal duty 50%
Parameter Symbol MIN. TYP. MAX. Unit
Peak emission wavelength λp630 660 690 nm
Output optical power couple into fiber PC-21 -18 -15 dBm
Supply current
ICC -813mA
VCC=3.0V 2.3 - -
VCC=5.0V 2.9 - -
VCC=3.0V --0.8
VCC=5.0V --1.3
L H delay time tpLH --180ns
H L delay time tpHL --180ns
Pulse width distortion Δtw-15 - +15 ns
Jitter
Δtj-115ns
Measurement method
refer to Fig. 3, 4
Conditions
Measurement method refer to Fig. 1
Measurement method
refer to Fig. 2
High level input voltage
ViH
Low level input voltage
ViL
3
GP1FAV31TK0F
Measurement Method
Fig. 1 Output Optical Power Coupled Into Fiber
Fig. 2 Input Voltage and Supply Current
GP1FAV31TK0F
Device under test
Optical power meter
(Anritsu) ML93B
Vin Vcc
Vcc
GND The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
Notes
1. Vcc = 3.0 V (State of operating)
2. To bundle up the standard fiber optic cable, make it into a loop with the diameter D = 10 cm or more.
(The standard fiber optic cable will be specified elsewhere.)
D
Standard fiber optic cable
Vin
Vin
Vcc
Icc
Vcc
GND
The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
Standard fiber optic cable
Sheet No.: E2-A00601EN
GP1FAV31TK0F
Device under test
Optical power meter
(Anritsu) ML93B
VCC = 5.0 V (State of operating)
VCC = 3.0 V (State of operating)
Input conditions and judgment method
No. Input conditions Judgment method
1
Vin = 2.9 V or more -21 PC -15 dBm, ICC = 13 mA or less
2
Vin = 1.3 V or less PC -36 dBm, ICC = 13 mA or less
No. Input conditions Judgment method
1
Vin = 2.3 V or more -21 PC -15 dBm, ICC = 13 mA or less
2
Vin = 0.8 V or less PC -36 dBm, ICC = 13 mA or less
4
GP1FAV31TK0F
Fig. 3 Pulse Response and Jitter
Fig. 4 Input Signal (7.75 Mb/s Bi-phase PRBS Signal)
Vin
Vin
Vcc
Icc
Vcc
Input
GND
CH1
CH2
Oscilloscope
Oscilloscope (band width: 1 GHz)
Trigger: CH1
Mode: Storage mode
Standard fiber optic cable
1
Input signal
7.75 Mb/s bi-phase PRBS signal
10 0
Input signal 50%
tpLH
tjr tjf
tpHL
50%
Standard receiver output
Sheet No.: E2-A00601EN
Standard receiver Output signal
GP1FAV31TK0F
Device under test
Notes
(1) The wave form write time shall be 4 s. But do not allow the wave form to be distorted by increasing the brightness too much.
(2) VCC = 3.0 V/5.0 V (State of operating)
(3) The probe for the oscilloscope must be more than 1 MΩ and less than 10 pF.
5
GP1FAV31TK0F
Design and Production Notes
Sheet No.: E2-A00601EN
(1) Stabilization of power supply line
Please put a by-pass capacitor (0.1 μF) close to the device at least within 7 mm of the terminal.
Please also put a 4.7 μF capacitor across the power supply line nearby.
(2) Soldering condition
Solder at the condition within the absolute maximum ratings in this sheet. In case of using flow soldering, please make
sure of the conditions of process at the flow equipment. Also, do not use reflow soldering. In case of soldering by hand,
do not contact top of soldering iron to lead terminal directly. (Solder at a position more than 1.6 mm away from the base
of the lead terminal.)
(3) About getting dirt and dust in the connector coupling portion
In case dirt or dust comes into the connector coupling portion, please use a blower to take it off.
Any rigid rod-like object must not be inserted since into the coupling portion.
The internal device might be damaged, resulting deteriorated characteristics.
(4) Cleaning
Do not immerse for cleaning. The solvent would get into the connector coupling portion resulting deteriorated
characteristics. Should it be necessary to remove the flux, please use one of the following solvents only to be applied with
a brush.
Solvent : Isopropyl alcohol, Methyl alcohol
(5) Ground during assembling
The human body and the soldering iron must be grounded against the static breakdown of the device during assembling.
Please avoid touching the device terminals as much as possible before assembling.
(6) Assembly of the device
Please fix this device with a screw. In case that this device is not fixed with a screw, stress by detaching connector of
internal elements and leads can adversely affect the device’s reliability. Excessive torque can deform the package and
damage the optics. It can also adversely affect the device’s reliability because the device is used under continuous stress.
Please confirm the limit of fixing torque to the installation before fixing actually.
Recommended values
Screw : M3.0 × 8 mm tapping screw
Fixing torque : 0.7 to 0.8 N·m
Force applied by driver etc. : 39 N or less
Note : Please contact and consult with a Sharp sales representative for any questions about above.
(7) Input signal
This product is designed intentionally based upon the signal transmission which is defined by the digital audio interface
standard ; CP1201. When a signal out of JEITA standard CP-1201 is inputted to this device, there might be a case that this
device can not transmit a signal correctly to receiving unit.
(8) Fixing pin
Since there are other products which has a different fixing pin shape, please make sure to confirm reference mounting
drawing for this device.
(9) Damage to connector coupling portion
Please do not stress the connector coupling portion excessively since there might be a case that the shutter can’t operate
normally.
(10) About getting the flux into connector coupling portion
Please avoid getting a flux into connector coupling portion of this device, because there might be a case that the characteristics
deteriorate the shutter can’t operate normally.
6
GP1FAV31TK0F
Packing Specifications
TRAY
PRODUCT
Cross
section of tray
PACKING METHOD
Each tray holds 200 pieces.
PACKING MATERIAL
Tray : Polystyrene
PRODUCT
Presence of ODC etc.
This product shall not contain the following materials.
And they are not used in the production process for this product.
Regulation substances : CFCs, Halon, Carbon tetrachloride, 1.1.1-Trichloroethane (Methylchloroform)
Specific brominated flame retardants such as the PBB and PBDE are not used in this product at all.
This product shall not contain the following materials banned in the RoHS Directive (2002/95/EC).
• Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB),
Polybrominated diphenyl ethers (PBDE).
Sheet No.: E2-A00601EN
7
GP1FAV31TK0F
Important Notices
· The circuit application examples in this publication are
provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit
design or license any intellectual property rights. SHARP
takes no responsibility for any problems related to any
intellectual property right of a third party resulting from the use
of SHARP's devices.
· Contact SHARP in order to obtain the latest device specifi-
cation sheets before using any SHARP device. SHARP
reserves the right to make changes in the specifications,
characteristics, data, materials, structure, and other
contents described herein at any time without notice in
order to improve design or reliability. Manufacturing
locations are also subject to change without notice.
· Observe the following points when using any devices in this
publication. SHARP takes no responsibility for damage
caused by improper use of the devices which does not meet the
conditions and absolute maximum ratings to be used specified
in the relevant specification sheet nor meet the following condi-
tions:
(i) The devices in this publication are designed for use in
general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii) Measures such as fail-safe function and redundant design
should be taken to ensure reliability and safety when SHARP
devices are used for or in connection
with equipment that requires higher reliability such as:
--- Transportation control and safety equipment (i.e.,
aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii) SHARP devices shall not be used for or in
connection with equipment that requires an extremely high
level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g.,
scuba).
· If the SHARP devices listed in this publication fall
within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Law of Japan, it is
necessary to obtain approval to export such SHARP devices.
· This publication is the proprietary product of SHARP and
is copyrighted, with all rights reserved. Under the copy-
right laws, no part of this publication may be repro-
duced or transmitted in any form or by any means,
electronic or mechanical, for any purpose, in whole or in
part, without the express written permission of SHARP.
Express written permission is also required before any use
of this publication may be made by a third party.
· Contact and consult with a SHARP representative if there
are any questions about the contents of this publication.
Sheet No.: E2-A00601EN
8