Copyright © Murata Manufacturing Co, Ltd. All rights reserved. March 2014
SF2002E (R) 6/5/17 Page 1 of 5 www.murata.com
Electrical Characteristics
Electrical Connections
Characteristic Sym Notes Min Typ Max Units
Nominal Operating Frequency fC942.5 MHz
Passband Insertion Loss, 925 to 960 MHz IL 2.2 3.0 dB
Amplitude Ripple, 925 to 960 MHz 0.8 1.5 dBP-P
Attenuation Referenced to 0 dB:
DC to 905 MHz 17.0 20.5 dB
905 to 915 MHz 5.0 15.0 dB
980 to 1000 MHz 13.0 30.0 dB
1000 to 2000 MHz 20.0 23.0 dB
VSWR, 925 to 960 MHz 2.2 2.7 dB
Source Impedance 1 50
Load Impedance 1 50
Case Style SM3030-6 3 x 3 mm Nominal Footprint
Lid Symbolization (YY=year, WW=week, D=day) 597 YWWS
Connection Terminals
Input 2
Output 5
Ground All others
SM3030-6
• RF Filter for EGSM
• Low-loss Design
• No Matching Circuit Required
• 3.0 x 3.0 x 1.3 mm Package
• Complies with Directive 2002/95/EC (RoHS)
Absolute Maximum Ratings
Rating Value Units
Maximum Input Power +15 dBm
DC Voltage on any Non-ground Terminal -5 to +5 VDC
Operable Temperature Range -45 to +125 °C
Specification Temperature Range -30 to +85 °C
Storage Temperature Range in Tape and Reel -40 to +85 °C
Maximum Soldering Profile, 5 Cycles/10 seconds Maximum 265 °C
942.5 MHz
SAW Filter
SF2002E
1. Unless noted otherwise, all specifications apply over the operating tem-
perature range with filter soldered to the specified demonstration board
with impedance matching to 50 and measured with 50 network ana-
lyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the
nominal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the
passband. Rejection in final user application is dependent on PCB layout
and external impedance matching design. See Application Note No. 42
for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production"
and "ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are
subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design.
However, impedances and impedance matching may vary between Port 1
and Port 2, so that the filter must always be installed in one direction per
the circuit design.
7. US and international patents may apply.
8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered
trademarks of Murata Manufacturing Co., Ltd.
50
50
SAW Filter
TOP VIEW
pin 2 pin 5
All Others
Pb
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
NOTES: