504 Dimensions are shown for
reference purposes only. Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
P&B
Catalog 1308242
Issued 3-03
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Features
• Up to 30A switching in SPST and 20A switching in SPDT arrangements.
• Silver cadmium oxide contacts.
• Available as an open-frame relay, with a snap-on dust cover or with an
immersion cleanable(6), plastic sealed case.
• Meets UL 508 & UL 873 spacing – 1/8” through air, 1/8” over surface.
(1/4” over surface with terminal code 4)
• UL class F insulation standard.
• Well suited for various industrial, commercial and residential applications,
as well as many others.
Typical Coil Temperature Rise
Data below are average values and should be verified in application. Tests
were conducted within a 2’ (.6 m) cube (still air) with relay mounted to a
30A, single side P.C. board (6); at nominal coil power @ 25°C; with normally
open contact loaded; and with 4’ (1.22 m) long, #10 AWG load wires.
File E22575 File LR15734
Patented
Notes
(1) Operating ambient temperature must consider “Must Operate Voltage Change
Over Temperature,” Contact Temperature Rise, Coil Temperature Rise (If coil
is not allowed to cool) and Maximum Coil Temperature. Specification ambient
considers nominal coil voltage, 20A load with coil cooled to ambient.
(2) Sealed relay terminals should not be bent.
(3) Knock-off nib should be removed after cleaning process for optimum life of
sealed relays.
(4) Maximum soldering temperature is 500°F for 4 seconds.
(5) Class F coils are UL systems approved for maximum coil temperature of
155°C by change of resistance method.
(6) See application note 13C265 for proper relay mounting, termination, cleaning
and PC board conductor width. Coil rise test performed with 30A PC board to
maintain 20°C maximum rise @ 30A.
Mechanical Data
Termination: Printed circuit terminals(4).
Enclosures (all have 94V-0 flammability rating, Class F temp. rating):
Optional dust cover:Snap-on plastic dust cover is available for use on
open style T90N.
Sealed case (T90S): Immersion cleanable, sealed plastic case(2).
Weight: Open Model T90N: 0.7 oz. (20g) approximately.
Sealed Model T90S: 0.9 oz. (26g) approximately.
Environmental Data
Storage Temperature Range: -40°C to 130°C.
Operating Temperature Range: -55°C to +85°C(1).
Vibration, Operational: 0.065” (1.65mm) max. excursions from 10-55 Hz.
with no contact opening >100µs.
Shock, Operational: 10g for 11 ms with no contact opening >100µs.
Shock, Mechanical: 100g.
Operate Data @ 25°C
Must Operate Voltage:75% of nominal voltage or less.
Must Release Voltage: 10% of nominal voltage or more.
Operate Time (Including Bounce)†: 15 ms, max.
Release Time (Including Bounce)†: 15 ms, max.
† At or From Nominal Coil Voltage
T90 series
30 Amp Printed Circuit Board Relay
130
120
110
100
90
80
70
60
50
40
30
20
50 75 100 125 150 175 200 225
30A Load
25A Load
20A Load
15A Load
10A Load
0A Load
150
140
130
120
110
100
90
80
70
60
50
40
30
20
50 75 100 125 150 175 200 225
Sealed Relay, Vented
(3)
0A Load
10A Load
30A Load
25A Load
20A Load
15A Load
Open Style Relay, No Dust Cover
Applied Continuous Coil Voltage (% of Rated Voltage)
Coil Temp. Rise Above Ambient (°C)
Applied Continuous Coil Voltage (% of Rated Voltage)
Coil Temp. Rise Above Ambient (°C)
Minimum Contact Load:
Silver Contacts: 500mA @ 5VDC or 12VAC.
Silver Cadmium Oxide Contacts: 1A @ 5VDC or 12VAC.
Initial Contact Resistance: 75 mΩ, max., @ min. rated current (switched).
Contact Ratings @ 25°C
Arrangements: 1 Form A (SPST-NO) and 1 Form C (SPDT).
Material: Silver-cadmium oxide.
Mechanical Life: 10 million operations, typical.
Initial Dielectric Strength
Between Open Contacts: 1,500V rms.
Between Contacts and Coil: 1,500V rms ( terminal code 1).
2,500V rms (UL 873 version terminal code 4).
Initial Insulation Resistance
Between Mutually Insulated Elements: 109 ohms, min., @ 500VDC,
25°C and 50% R.H.
Coil Data @ 25°C
Voltage: 5 to 110VDC.
Maximum Coil Power: 2.8 Watt
Maximum Coil Temperature(5): Class F: 155°C.
Duty Cycle: Continuous.
Nominal Voltage Resistance Nominal Power Nominal Current
(VDC) ± 10% (Ohms) (mW) (mA)
5 27 930 185
6 40 900 150
9 97 840 93
12 155 930 77
15 256 880 59
18 380 850 47
24 660 870 36
48 2,560 900 19
110 13,450 900 8
Coil Data
Typical Electrical Load & Life (Open Style Relay)
Form & Contact Material Contact Load Type of Load Ops
(1) Silver-cadmium 30A @ 240VAC UL General Purpose 100,000
oxide 20A @ 240VAC Resistive Heater 100,000
(5) Silver-cadmium 20A/10A @ 240VAC UL General Purpose 100,000
oxide 20A/10A @ 28VDC Resistive 100,000
Contact Ratings @ 25°C with relay properly vented. Remove vent
nib after soldering and cleaning.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.