Data Sheet Battery Analyzers BA6010 Series USB The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, dissipation factor, impedance, quality factor, reactance, phase angle in degrees, and capacitance in farads. Features & Benefits 4.3 inch color LCD display n Trace function for graphical display of voltage and resistance with on-screen cursor measurements 4-wire kelvin test leads with fault monitoring of drive and sense lines n The BA6010 Series is suitable for characterizing battery chemistries that are responsive to a 1 kHz AC stimulus signal, including lead acid, lithium and alkaline type batteries used in consumer products, electric vehicles, power backup, security, and fire alarm systems. Model BA6011 supports voltage measurements of battery packs up to 300 V whereas the BA6010 features a 6 V measurement range ideal for battery cell testing. The handler and remote interfaces expands the analyzer's application to R&D and automated manufacturing environments. Wide range of measurements n n RS232 Compare and sort using 9 bins with statistical Two user-selected measurements can be displayed simultaneously, along with stimulus signals Vm and Im. Unlike comparable battery testers that only support voltage and resistance measurements, users can also characterize additional parameters such as battery capacitance thus providing additional insight into a battery's condition. evaluations n % mode for quickly determining the percent difference between batteries n Pass/Fail indicator with audible tone n Fast test speed up to 50 measurements per second to increase manufacturing throughput n Trigger modes internal, manual, bus and external n 100 internal and external storage locations for RS Cdl Rct Simplified Randles cell setup and screen save n Handler Main measurement parameters interface for easy integration with a component handler or integration with PLC n Standard RS232, USB (USBTMC and virtual COM) interfaces Model Input voltage range Basic voltage accuracy Voltage resolution BA6010 6 V / 60 V 0.05 % 100 V BA6011 30 V / 300 V 0.05 % 1 mV Technical data subject to change (c) B&K Precision Corp. 2018 www.bkprecision.com Auxiliary measurement parameters Battery Analyzers BA6010 Series Front panel Bright LCD display Navigation keys Display and setup keys Numeric Function keypad keypad Pass/Fail Indicator Power button Menu function keys USB host port Input terminals Large 4.3 inch color LCD screen for easy viewing of configuration and measurements. 4-terminal front panel connection and quick connect test fixture for high accuracy measurements. Rear panel AC input terminal Chassis ground terminal Fuse line selector box Handler interface BNC Trigger USB interface terminal RS232 interface Standard RS232, USB (USBTMC and virtual COM) interfaces, handler interface and external BNC trigger input are useful for production automation. 2 www.bkprecision.com Battery Analyzers BA6010 Series Flexible operation Improved measurement accuracy Binning function Comparator function The 4-terminals on the front of the BA6010 Series are used together with the Kelvin clip test fixture. This system minimizes the influence of the test lead resistance and improves measurement accuracy. Quickly sort components using up to 9 bins. The bin results are displayed on-screen with each cycle. The handler interface includes dedicated signal pins for each bin, Pass/Fail and end of measurement. The handler interface is suitable for integration with device handler systems or programmable logic controllers (PLC) used in production automation. The comparator function evaluates measurements against a user specified upper and lower limit for pass/fail (Go/No Go) style testing. Comparative evaluations can be made using primary, secondary or both measurements. The front panel PASS / FAIL indicator will illuminate and a sounder can be enabled for audible confirmation. Bin comparator display Compare test - below limits Kelvin clip test fixture Bins for sorting devices Compare test - above limits 4-wire kelvin connection On screen monitoring system detects test probe contact failure and damaged leads for reliable measurements. Statistical function Trace function The analyzers can perform statistical calculations on the measurements and display the results on-screen. The trace function samples and plots two user-selected measurement readings over a specified time. Enable cursors for viewing plotted values and time stamp information. Cursor with measurements Error: HI drive open Error: LO drive open Error: HI sense open Error: LO sense open Error: Measure line open 3 Statistical tools menu Trace display www.bkprecision.com Battery Analyzers BA6010 Series Specifications All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 20 C 5 C. Specifications are subject to change without notice. Model Measurement Parameters BA6010, BA6011 Main V, R Auxiliary L, C, D, Z, X, Q, d, and r Test Frequency 1 kHz 0.2 Hz Display Resolution 5 digits (SLOW & MED), 4 digits (FAST) Measurement Speed SLOW, approx. 6.25 measurements/sec MED, approx. 10 measurements/sec FAST, approx. 50 measurements/sec Temperature Coefficient Voltage Meas. 0.005 % / C Resistance Meas. 0.05 % / C Triggering Internal, External, Manual, Bus Delay Time On / Off, 0 ms to 60 s Averaging 1 to 255 samples Statistical Calculations Valid data count, Invalid data count, Mean, Maximum, Minimum, Standard Deviation, Sample Standard Deviation, Process Capability Index (Dispersion), Process Capability Index (Deviation) Voltage Measurement (BA6010) SLOW, MED Range Maximum Display Value Resolution 6V 6.5000 V 100 V 60 V 65.000 V 1 mV Range Maximum Display Value Resolution 6V 6.500 V 1 mV 60 V 65.00 V 10 mV Accuracy (0.05 % FS) FAST Accuracy (0.1 % FS) Voltage Measurement (BA6011) SLOW, MED Range Maximum Display Value Resolution 30 V 35.000 V 1 mV 300V 310.00 V 10 mV Range Maximum Display Value Resolution 30 V 35.00 V 10 mV 300 V 310.0 V 100 mV Accuracy (0.05 % FS) FAST 4 Accuracy (0.1 % FS) www.bkprecision.com Battery Analyzers BA6010 Series Specifications Resistance Measurement SLOW, MED Range Maximum Display Value Resolution Measurement Current 30 m 33.000 m 1 100 mA ( 10 %) 300 m 330.00 m 10 100 mA (10 %) 3 3.3000 100 10 mA ( 10 %) 30 33.000 1 m 1 mA ( 10 %) 300 330.00 10 m 100 A ( 10 %) 3 k 3.5000 k 100 m 10 A ( 10 %) Range Maximum Display value Resolution Measurement Current 30 m 33.00 m 10 100 mA ( 10 %) 300 m 330.0 m 100 100 mA ( 10 %) Accuracy (0.3 % + 0.1 % FS) FAST 3 3.300 1 m 10 mA ( 10 %) 30 33.00 10 m 1 A ( 10 %) 300 330.0 100 m 100 A ( 10 %) 3 k 3.500 k 1 10 A ( 10 %) Accuracy (0.5 % + 0.3 % FS) Accuracy of Auxiliary Measurement Parameters L, C, D, Z, X, Q, d, and r 5 % typical** ** see user manual for more details Bin Comparator Function Limit Setting Mode Tolerance (TOL) or Absolute (ABS) value Number of Bins 9 sorting bins BIN1-BIN9 Beep Warning OFF, PASS, FAIL Trace Function Total Time 1 s - 99999 s Sampling Interval 1 s - 86400 s General Instrument Settings Save/ Recall Save / Recall Internal or External Memory: Up to 100 Measurements, Bin Comparator Results, Screenshots Save External Memory: Up to 100 Remote Interface USBTMC / USB (Virtual COM), RS232, Display 4.3", 480 x 272 LCD display AC Input 110 V 10 % or 220 V 10 %, 47 to 63 Hz Power Consumption 15 VA Max. Operating Temperature 0 C to 40 C Storage Temperature -10 C to 70 C Relative Humidity up to 80 % Dimension (WxHxD) 9.25" x 4.1" x 14.17" (235 x 104 x 360 mm) Weight 7.9 lbs (3.6 kg) Included Accessories User manual (downloadable), power cord, 4-wire kelvin clip test fixture (TLKB1), certificate of calibration & test report Three-Year Warranty 5 v080918 www.bkprecision.com