Amprobe® Test Tools www.Amprobe.com
Data Sheet
Function Range Accuracy
Specifications
General Specifications
5XP-A Digital Multimeter
Voltage
DC Volts
Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V ± (1.0 % rdg + 1 dgt)
AC Volts (45 Hz to 500 Hz)
Ranges 200 mV, 2 V, 20 V, 200 V, 750 V ± (1.5 % rdg + 5 dgts)
Resolution 100 μV
Input Impedance 10 MW
Overload Protection 200 mV: 1000 V DC or 750 V AC RMS (3 minutes)
All other ranges: 1000 V DC or 750 V AC RMS
Current
DC Current
Ranges 200 μA, 2 mA, 20 mA, 200 mA ± (1.5 % rdg + 1 dgt)
AC Current (45 Hz to 500 Hz)
Ranges 200 μA, 2 mA, 20 mA, 200 mA ± (2.0 % rdg + 5 dgts)
Resolution 0.1 μA
Input Protection 315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input
Burden Voltage 300 mV max. (1 V max. on 200 mA range)
Resistance 200 W, 2 kW, 20 kW, 200 kW ± (1.0 % rdg + 4 dgts)
2 MW ± (1.5 % rdg + 4 dgts)
20 MW ± (2.0 % rdg + 5 dgts)
Resolution 100 mW
Open Circuit Voltage 0.3 V DC typical, (3.0 V DC on 200 W range)
Overload Protection 1000 V DC or 750 V AC RMS
Continuity
Audible Indication 75 W ± 25 W
Response Time 100 ms
Overload Protection 1000 V DC or 750 V AC RMS
Display 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Low Battery Indication The “M” is displayed when the battery voltage drops below the operating level
Measurement Rate 2.5 times per second, nominal
Operating Environment 0 °C to 50 °C at <70 % R.H.
Storage Temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Accuracy Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
Altitude 2000 m (6561.7 ft)
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 200 hours typical with carbon-zinc
Dimensions (H x W x D) 155 mm x 72 mm x 32 mm (6.1 in x 2.8 in x 1.3 in)
Weight Approx. 210 g (7.4 oz) including battery
Warranty One-year