Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVE RT ERS
48 VDC Input / 140 W Output , 1/8 Brick
• Industry standard eighth-brick package
• Up to 140 W at 95% efficiency
• 1500 V Isolation
• Remote On/Off
• Low Cost
Description
The 0RCR “Cimarron” Serie s are isolated DC/DC converter s that operate from a nominal 48 VDC source. These
converters use a half bridge power train to provide isolation and step down. These units will provide up to 140 W
of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost.
Features include remote on/off, over curren t protection and under voltage lockout. These converters are provided
in an industry standard eighth-brick package.
Part Selection
Output
Voltage Input Voltage Max. Output
Current Max. Output
Power Typical
Efficiency Model Number
Acti ve L ow Model Num b er
Acti ve Hig h
8 V 48 V 18 A 140 W 95% 0RCR-18S08L 0RCR-18S08H
12 V 48 V 12 A 140 W 95% 0RCR-12S12L 0RCR-12S12H
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the seco nd le tter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter Min Typ Max Notes
Input Voltage (continuous) V - V
Remote On/Off 0 V - 60 V
Operating Temperature -40 °C - 85 °C
Non-Operating Temperature -55 °C - 125 °C
Input Specifications
Parameter Min Typ Max Notes
Input Voltage 36 V - 60 V
Input Current (full load) - - 3 A
Input Current (no load) - - 45 mA
Input Reflected Ripple Current (pk-pk) - - 30 mA
Input Reflected Ripple Current (rms) - - 10 mA
Reflected ripple current through a 10uH
source inductor at nominal input
voltage and rated load current.
Note: All specifications are typical at 25 °C unless otherwise stated.
0RCR “Cimarron” Series RoHS Com
liant