EF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed) Standard- or Medical-Filter C20 70 C Description - Panel Mount : Screw-on mounting from front side - 3 Functions : Appliance Inlet Protection class I , circuit breaker type TA45 2-pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired Circuit Breaker non-illuminated or illuminated With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Variant with notch for V-Lock mating Cordsets Approvals - Approval Reference Type: EF12 - VDE Certificate Number: 40001520 - UL File Number: E72928 References Alternative: version without line filter EF11 Alternative: Standard version Weblinks pdf datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, DistributorStock-Check, Accessories, Detailed request for product, Microsite Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 12 - 16 A @ Ta 40 C / 250 VAC; 50 Hz 12 - 20 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Circuit Breakers Line Filter MTBF C20 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 16 A, Protection Class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 100'000 h acc. to MIL-HB-217 F Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product Information EMC Products 1 EF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimensions [mm] 37 2.8 76.2 10.6 32.2 41.2 32.9 o3.6/M3 810.10 90 0.10 80.05 .5 R6 9.5 o3.3 59.5 5.3 33.9 0.10 4.55 0.05 4. 7 R 05 3. 5.5 R 10.9 R 2.8 12.6 12.2 40.55 79.2 90 101 R 3. 55 0 .0 5 0.8 o6.4 * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 12 Standard Version 2 x 0.8 100 2.2 1 16 Standard Version 2 x 0.6 100 2.2 1 20 Standard Version 2 x 0.3 100 2.2 1 12 Medical Version (M5) 2 x 0.8 100 - 1 16 Medical Version (M5) 2 x 0.6 100 - 1 20 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Medical version (M5) L' L P1 PE Cx N Cy R L2 Cy TA 45 L1 1) PE' N' P2 1) Line 2) Load 2 2) P1 L1 1) PE N 1) Line 2) Load EMC Products L' L Cx TA 45 Standard version PE' R L2 N' P2 2) EF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 12 A 16 A 20 A 16 A 20 A Medical version (M5) 12 A EMC Products 3 EF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Table 1 Selection for type TA45 Order example 3 P1 ABT W * Circuit Breaker of Equipment * 2-pole, rocker actuated * Quick connect terminal Other types on request 5 a Diagram Thermal overload protection 1-pole P2 Without illumination P1 3 6 With illumination 220...240 V 110...120 V 2-pole P2 P1 4 3 ABT ABD A12 A14 A32 A34 } Colours Switch front W B 6 Rocker black black black white black - - - orange transp. Rocker legend printed l O black P printed I O white black R printed I O black white printed K printed L printed l embossed H ON M white F Position of the rocker legend e.g F Rated current circuit breaker of equipment In Code In Code In Code In Code 10,0 11,0 12,0 100 110 120 13,0 14,0 15,0 130 140 150 16,0 17,0 18,0 160 170 180 19,0 20,0 190 200 Other rated currents on request Without release: code C0 Undervoltage release P2 P1 U< 4 P2 Remote trip release b U< Colour of print l Illustration O Surface ON Colour of print OFF OFF Illustration O Surface P1 P2 ba P1 P2 c P1 U< U E Z A Code Rated voltage Un * * * * 2 240 V AC * * * * 3 230 V AC * * * * 4 120 V AC EMC Products F 150 C0 EF12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 60 Tripping characteristics In > 3... < 18 A Type TA45 Rated current In <3 A [ min ] [ sec ] 10'000 60 1 pole protected 2000 30 20 30 2 pole protected 20 1000 10 +23 C Ambient temp. 500 Tripping characteristics In > 18 A [ min ] [ sec ] 10'000 Type TA4 5 Rated current In > 3 A... < 18 A 60 1 pole protected 2000 30 2 pole protected 20 1000 10 +23 C Ambient temp. 500 10 5 5 1 1 pole protected 2 pole protected 1000 50 50 10 10 5 5 5 2 2 2 1 1 1 0,5 0,5 0,5 0,1 1,05 1,32 2 3 4 5 8 10 [ x In ] Multiple of rated current Tripping time 20 10 0,2 0,3 0,2 0,1 1,05 1,32 The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table on the right side: Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16 2 3 4 5 8 0,3 0,2 0,1 10 1,05 1,32 [ x In ] Multiple of rated current 1) Effect of ambient temperature * Ambient temperature [C] -10 -5 0 +23 +30 +40 +55 +23 C 100 1 20 0,3 Ambient temp. 500 20 Tripping time Tripping time 50 In >18 A 2000 200 100 100 1 TA4 5 Rated current 5 200 200 Type 2 3 4 5 8 10 [ x In ] Multiple of rated current * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. 1) Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature 6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A Configuration code (example) Type Order code TA45 (2-pole rocker-switch without accessories) EF12 - ABTWF150C0 - 000 - 1111 - 00 - 00 see table 1 Color 0 black Interlocking 0 without V-Lock 1 with V-Lock Terminal PE 1 QC 6.3x0.8 Terminal L and N 1 QC 6.3x0.8, without connection to TA45 3 Connection to TA45 non insulated Type of mains filter / capacitor / bleed resistor 1 standard X2,Y2 with bleed resistor 2 medical M5 X2 with bleed resistor Rated current 1 20 A 2 16 A 3 12 A 1) 1) The rated current of the line-filter must be equal or more than the rated current of TA45. EMC Products 5 EF12 Packaging unit Power Entry Modules with Line Filter https://www.schurter.com /PG06 16 Pcs Accessories Description Cord retaining kits Cord retaining strain relief Flat head, Z 0888.0021 Flat head, H 4700.0008 Mating Outlets/Connectors Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 0104U Connector further types to EF12 Mating Outlets/Connectors shuttered Power Cord Overview complete Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS 30.10.2017 Power Cord further types to EF12 6 EMC Products The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.