1
Power Entry Modules with Line Filter EF12
https://www.schurter.com /PG06
EMC Products
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed) Standard- or Medical-Filter
C20
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet Protection class I , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Approvals
- Approval Reference Type: EF12
- VDE Certificate Number: 40001520
- UL File Number: E72928
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- With EMC-shield
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version without line filter EF11
Alternative: Standard version
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC 12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 12 - 20 A @ Ta 40 °C / 250 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Tempe-
rature
-10 °C to 55 °C
Climatic Category 10/055/21 acc. to IEC 60068-1
IP-Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness S Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Line Filter Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
MTBF > 100'000 h acc. to MIL-HB-217 F
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product
Information
2
Power Entry Modules with Line Filter
EF12 https://www.schurter.com /PG06
EMC Products
Dimensions [mm]
ø3.3
90
101
ø6.4
33.9
59.5 5.3
12.2 40.55
79.2
10.9
32.2
37
41.210.6
76.2 2.8
5.5
R 6.5
R 4.7
R 2.8
0.8
12.6
80.05
32.9
R 3.05
±0.10
90
±0.10
ø3.6/M3
±0.05
R 3.55
±0.10
81
±0.05
4.55
9.5
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [M]
12 Standard Version 2 x 0.8 100 2.2 1
16 Standard Version 2 x 0.6 100 2.2 1
20 Standard Version 2 x 0.3 100 2.2 1
12 Medical Version (M5) 2 x 0.8 100 - 1
16 Medical Version (M5) 2 x 0.6 100 - 1
20 Medical Version (M5) 2 x 0.3 100 - 1
Diagrams
Standard version
Cx
L1
L2
Cy
Cy
2)
L’
PE’
N’
P1
P2
L
PE
N
1)
TA 45
R
1) Line
2) Load
Medical version (M5)
Cx
L1
L2
R
2)
L’
PE’
N’
P1
P2
L
PE
N
1)
TA 45
1) Line
2) Load
3
Power Entry Modules with Line Filter EF12
https://www.schurter.com /PG06
EMC Products
Attenuation Loss - - - - 50 differential mode _____ 50 common mode
Standard version
12 A 16 A 20 A
Medical version (M5)
12 A 16 A 20 A
4
Power Entry Modules with Line Filter
EF12 https://www.schurter.com /PG06
EMC Products
ABT W F 150 C0
Colours
Switch front Rocker
W black white
B black black
6 black orange transp.
F embossed
H printed white
K printed black
L printed white
Surface Illustration Colour of print
Rocker legend
l
O
ON
OFF
ON
OFF
l
O
M printed black
P printed white
R printed black
Surface Illustration Colour of print
In Code
10,0 100
11,0 110
12,0 120
In Code
13,0 130
14,0 140
15,0 150
In Code
16,0 160
17,0 170
18,0 180
In Code
19,0 190
20,0 200
Without release: code C0
Undervoltage release Remote trip release
UEZACode
Rated
voltage Un
2
3
4
240 V AC
230 V AC
120 V AC
l
O
OI
OI
Position of the rocker legend
e.g FRated current circuit breaker of equipment
Table 1 Selection for type TA45
Order example
Circuit Breaker of Equipment
2-pole, rocker actuated
Quick connect terminal
Other types on request
Without illumination
With illumination 220…240 V
110…120 V
35
P1
a
Diagram
Thermal overload protection 1-pole 2-pole
ABT ABD
A12 A32
A14 A34
}
Other rated currents on request
P2 P1
U<
P2 P1
c
P2 P1
6343
P2 P1
P2 P1
b
U<
P2 P1
ba
U<
5
Power Entry Modules with Line Filter EF12
https://www.schurter.com /PG06
EMC Products
* Ambient temperature [°C] Correction factor
–10 0,89
–5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In > 3… < 18 A
Tripping characteristics
In > 18 A
Type TA45
Rated current In <3 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
10'000
60
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
Tr ipping time
Type TA 45
Rated current In > 3 A... < 18 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
10'000
60
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
Tr ipping time
Type TA 45
Rated current In 18 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
Tr ipping time
10'000
60
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
>
1) Effect of ambient temperature
The unit is calibrated for an ambient tem pe rature of +23 °C. To de-
termine the rated current for a lower or higher ambient temperature,
use a correction factor from the table on the right side:
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+40 °C ambient temperature 6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
Configuration code (example)
Color
0 black
Interlocking
0 without V-Lock
1 with V-Lock
Terminal PE
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Type of mains fi lter / capacitor / bleed resistor
1 standard X2,Y2 with bleed resistor
2 medical M5 X2 with bleed resistor
Rated current 1)
1 20 A
2 16 A
3 12 A
1) The rated current of the line-fi lter must be equal
or more than the rated current of TA45.
EF12 - ABTWF150C0 - 000 - 1111 - 00 - 00
Type Order code TA45
(2-pole rocker-switch
without accessories)
see table 1
6
Power Entry Modules with Line Filter
EF12 https://www.schurter.com /PG06
EMC Products
Packaging unit 16 Pcs
Accessories
Description
Cord retaining kits
Cord retaining strain relief
Flat head, Z 0888.0021
Flat head, H 4700.0008
Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight 4795
IEC Connector C19, Rewireable, Angled 4790
IEC Connector C19, Rewireable, Straight 0104U
Connector further types to EF12
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS
Power Cord further types to EF12
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
30.10.2017