M18 Cylindrical Photoelectric E3F2
Threaded Cylindrical M18 Size
Sensors with Built-in Amplifier
Rugged stainless and nickel plated
brass versions
Chemical resistant, ABS resin case type
Polarized models
Compact and space-saving
Long detection distance (7 m)
DC switching types with connectors for
easy maintenance
Wide operating voltage range
(10 to 30 VDC, or 24 to 240 VAC)
Short-circuit and reverse connection
protection (DC switching type)
UL, CSA listed and CE marked
Ordering Information
SENSORS
Supply Type Connection Output Range Housing Part number
AC Through-beam Pre-leaded Light-On 3 m Plastic E3F2-3Z1
g
Dark-On Plastic E3F2-3Z2
Retroreflective,
Nlid
Light-On 2 m Plastic E3F2-R2Z1
,
Non-polarized Dark-On Plastic E3F2-R2Z2
Diffuse Light-On 100 mm Plastic E3F2-DS10Z1N
Dark-On Plastic E3F2-DS10Z2N
DC Through-beam Connector NPN 7 m Plastic E3F2-7C4-P1
g
NPB E3F2-7C4-M1–C
SS E3F2-7C4-M1-S
PNP Plastic E3F2-7B4-P1
NPB E3F2-7B4-M1-C
SS E3F2-7B4-M1-S
Diffuse NPN 10 cm NPB E3F2-DS10C4-M1-C
SS E3F2-DS10C4-M1-S
Plastic E3F2-DS10C4-P1
30 cm Plastic E3F2-DS30C4-P1
Note: NPB = Nickel plated brass; SS = Stainless steel
(This table continues on the next page.)
E3F2
E3F2
2
Ordering Information Table – continued from previous page
Supply Type Connection Output Range Housing Part number
DC Diffuse Connector PNP 10 cm NPB E3F2-DS10B4-M1-C
SS E3F2-DS10B4-M1-S
Plastic E3F2-DS10B4-P1
30 cm Plastic E3F2-DS30B4-P1
Retroreflective,
Nlid
NPN 2 m Plastic E3F2-R2C4-P1
,
Non-polarized PNP Plastic E3F2-R2B4-P1
Retroreflective,
Pl i d
NPN NPB E3F2-R2RC4-M1-C
,
Polarized SS E3F2-R2RC4-M1-S
PNP NPB E3F2-R2RB4-M1-C
SS E3F2-R2RB4-M1-S
Through-beam Pre-leaded NPN 7 m Plastic E3F2-7C4
g
NPB E3F2-7C4-C
SS E3F2-7C4-S
PNP 7 m Plastic E3F2-7B4
NPB E3F2-7B4-C
SS E3F2-7B4-S
Diffuse NPN 10 cm NPB E3F2-DS10C4-C
Plastic E3F2-DS10C4-N
SS E3F2-DS10C4–S
30 cm Plastic E3F2-DS30C4
PNP 10 cm NPB E3F2-DS10B4-C
Plastic E3F2-DS10B4-N
SS E3F2-DS10B4-S
30 cm Plastic E3F2-DS30B4
Retroreflective,
Nlid
NPN 2 m Plastic E3F2-R2C4
,
Non-polarized PNP Plastic E3F2-R2B4
Retroreflective,
Pl i d
NPN 2 m NPB E3F2-R2RC4-C
,
Polarized SS E3F2-R2RC4-S
PNP NPB E3F2-R2RB4-C
SS E3F2-R2RB4-S
Note: NPB = Nickel plated brass; SS = Stainless steel
ACCESSORIES (ORDER SEPARATELY)
Description Part number
Sensor mounting bracket Y92E-B18
Lens protector kit (glass plate, two gaskets and metal retainer) E39-F31
Small corner cube reflector (38 H x 20 W x 11 D mm) E39-R3
Adhesive backed reflector tape (10 H x 35 W x 0.7 D mm) E39-RSA
Adhesive backed reflector tape (35 H x 40 W x 0.7 D mm) E39-RSB
Mounting bracket for E39-R1 reflector E39-L7
Right angle adapter for through-beam and retroreflective E3F2 sensors E39-RU1
CONNECTOR CORDSETS
Connector type Cable size Length Straight connector Right angle connector
4-wire DC
Mi Ch
22 AWG 2 m (6.56 ft) Y96E-44SD2 Y96E-44RD2
Micro Change
connector
5 m (16.40 ft) Y96E-44SD5 Y96E-44RD5
connec
t
or 10 m (32.8 ft) Y96E-44SD10 Y96E-44RD10
Robotic cable with
M12 t
2 m (6.56 ft) XS2F-D421-D80-R XS2F-D422-D80-R
M12 connector 5 m (16.40 ft) XS2F-D421-G80-R XS2F-D422-G80-R
E3F2 E3F2
3
REPLACEMENT PARTS
Description Part number
Reflector for E3F2-R24 retroreflective sensors E39-R1
Two plastic M18 mounting nuts E3F-PHWS
Specifications
DC SWITCHING MODELS
Part number E3F2-7C4-,
E3F2-7B4-E3F2-R2C4-,
E3F2-R2B4-E3F2-R2RC4-,
E3F2-R2RB4-E3F2-DS10C4-,
E3F2-DS10B4-E3F2-DS30C4-,
E3F2-DS30B4-
Method of detection Through-beam Retroreflective Diffuse
g
Non-polarized Polarized
Sensing range 7 m (22.96 ft) 2 m (6.56 ft) 2 m (6.56 ft) 10 cm (3.94 in) 30 cm (11.81 in)
Standard target 11 x 11 mm 56 x 56 mm 5 x 5 cm 90%
Kodak White
Card
10 x 10 cm 90%
Kodak White
Card
Supply voltage 10-30 VDC 10% maximum permissible ripple, peak-to-peak
Output NPN or PNP open collector, 100 mA, residual voltage 2 V max. at 100 mA
Current consumption 45 mA max. 25 mA max.
Response time 2.5 ms max.
Stabilization on Powerup 50 ms
Ambient temperature Operating –25°C to 55°C (–13°F to 131°F) with no icing
Storage –30°C to 70°C (–22°F to 158°F)
Ambient light immunity Incandescent: 3,000 x; Sunlight: 10,000 x
Relative humidity Operating 35% to 85% RH, no condensation
y
Storage 35% to 95% RH
Insulation resistance 20 M at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min. between current carrying parts and case
Vibration 10 to 55 Hz 1.5 mm double amplitude 1 hr each in X, Y, Z axes
Shock 500 m/s2 (approx. 50 G)
Enclosure IP67, NEMA 6 for metal versions; IP66 NEMA, 4 for plastic versions
Light source Infrared LED Red LED Infrared LED
Indicators Power and light received LEDs
Sensitivity adjustment Fixed Adjustable
Operation mode Light-ON or Dark-ON selectable with control wire
Weight Metal Pre-leaded 100 g; connector: 60 g
g
Plastic Pre-leaded 85 g; connector: 40 g
Circuit protection Output short-circuit and reverse polarity
Materials Lens Plastic
Housing Plastic (ABS),
nickel plated
brass, stainless
steel
Plastic Nickel plated
brass, stainless
steel
Plastic (ABS), nickel plated brass,
stainless steel
Cable sheath PVC
E3F2
E3F2
4
AC MODELS
Part number E3F2-3Z1, E3F2-3Z2 E3F2-R2Z1, E3F2-R2Z2 E3F2-DS10Z1N, E3F2-DS10Z2N
Method of detection Through-beam Retroreflective Diffuse
Sensing range 3 m (9.84 ft) 2 m (6.56 ft) 10 cm (3.94 in)
Standard target 11 mm 56 mm 10 x 10 cm 90% Kodak white card
Supply voltage 24–240 VAC ±10%, 50/60 Hz
Output SCR 200 mA max.; residual voltage 5 V max. at 200 mA
Power consumption 10 mA max. 5 mA max.
Response time 30 ms max.
Stabilization on Powerup 100 ms
Ambient temperature Operating –25°C to 55°C (–13°F to 131°F) with no icing
Storage –30°C to 70°C (–22°F to 158°F)
Ambient light immunity Incandescent: 3,000 x; sunlight: 10,000 x
Relative humidity Operating 35% to 85% RH, no condensation
y
Storage 35% to 95% RH
Insulation resistance 20 M at 500 VDC between current carrying parts and case
Dielectric strength 1,500 VAC, 50/60 Hz for 1 min. between current carrying parts and case
Vibration 10 to 55 Hz 1.5 mm double amplitude 2 hrs each in X, Y, Z axes
Shock 500 m/s2 (approx. 50 G)
Enclosure IP66, NEMA 1, 2, 4 (indoor)
Light source Infrared LED
Indicators Power and light received LEDs
Sensitivity adjustment Fixed
Operation mode Light-ON (Z1 models) or Dark-ON (Z2 models)
Weight Pre-leaded models 110 g
g
Connector models 55 g
Circuit protection
Materials Lens Acrylate resin
Housing Plastic ABS
Cable sheath PVC
E3F2 E3F2
5
En
g
ineerin
g
Data
OPERATING RANGE (TYPICAL)
E3F2-3- (Through-beam) E3F2-R2- (Retroreflective)
Operating position Y (cm)
X
Y
X
Y
Distance X (m) Distance X (m)
Operating position Y (cm)
Distance X (m)
E3F2-R2 and E39-RU1 (Right angle adapter)
80
40
20
0
-20
-40
-60
-80
01 512 523
60
50
05 1 512 523053445
150
100
50
0
-50
-100
-150
Distance X (m)
E3F2-3 and E39-RU1 (Right angle adapter)
E3F2-7-4 (Through-beam) E3F2-R2R-4 (Polarized, retroreflective)
Operating position Y (cm)
Distance X (m)
Operating position Y (cm)
Distance X (m)
0
–10
–20
–30
10
20
30
40
0 1 2 3 4 5 6 7 89
–40
0
–2
–4
–6
–8
2
4
6
8
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0
–10
10
E3F2
E3F2
6
E3F2-DS30- (Diffuse)
Operating position Y (cm)
X
Y
Distance X (cm)
E3F2-DS104-N
E3F2-DS104-P1
Operating position Y (mm)
Distance X (mm)
X
Y
15
10
5
0
–5
–10
–15 0 20 40 60 80 100 120
White
paper
(5 x
5 cm)
White
paper
(10 x
10 cm)
EXCESS GAIN VS. SET DISTANCE (TYPICAL)
E3F2-3- (Through-beam)
Excess gain ratio
Distance (m)
DC type
AC type
E3F2-R2- (Retroflective, Non-polarized)
Excess gain ratio
Distance (m)
AC type
DC type
Distance (m)
E3F2-R2 and E39-RU1 (Right angle adapter)
0.5 1 1.5 2 32.50
Distance (m)
E3F2-3 and E39-RU1 (Right angle adapter)
3.5
20.0
18.0
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
1.0
0.0
AC Type
DC Type
AC Type
DC Type
01234567
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
1.0
0.0
E3F2 E3F2
7
E3F2-74- (Through beam)
Excess gain ratio
Distance (m)
100
1
0,1
10
0 2 4 6 8 10 12 14
E3F2-R2R4- (Polarized retroreflective)
Excess gain ratio
Distance (m)
EXCESS GAIN VS. SET DISTANCE
E3F2-DS104-N
E3F2-DS104-P1
Excess gain ratio
Excess gain ratio
Distance (mm) Distance (mm)
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Sensing object
(black paper: 5
x 5 cm)
Sensing object
(white paper: 5
x 5 cm)
Sensing object
(white paper: 5
x 5 cm)
Sensing object
(black paper: 5
x 5 cm)
E3F2-DS10Z-N
9
8
7
6
5
4
3
2
1
25
5
10
0
15
30
20
0
Excess gain ratio
Distance (cm)
E3F2-DS304
E3F2-DS304-P1
0 10 20 30 40 50 60
Sensing object
(white paper:
10 x 10 cm)
Sensing object
(black paper:
10 x 10 cm)
0
10
20
30
40
50
45
35
25
15
5
E3F2
E3F2
8
O
peration
OUTPUT CIRCUITS
Configuration Model Connection
method Output
transistor Output circuit
NPN
pre-wired E3F2-7C4
E3F2-7C4-M
E3F2-7C4-C
E3F2-7C4-S
E3F2-R2C4
E3F2-R2RC4-M
E3F2-R2RC4-C
E3F2-R2RC4-S
E3F2-DS10C4-N
E3F2-DS10C4-M
E3F2-DS10C4-C
E3F2 DS10C4 S
Connect the
pink and
brown wires
or open the
pink wire.
ON when
light is
incident.
(Light-ON) Load
Brown (1) (see note)
100 mA max.
(control output)
Black
(4)
Main
circuit
Light indicator
Red
(Mode selec-
tion)
ZD
10 to
30 VDC
ZD:VZ = 36 V
Blue (3)
Pink (2)
E3F2 DS10C4 C
E3F2-DS10C4-S
E3F2-DS30C4
E3F2-DS30C4-M
E3F2-DS30C4-S
Connect the
pink and
blue wires.
ON when
light is in-
terrupted.
(Dark-ON)
100 mA max.
(control output)
Main
circuit
Red
Blue
Black
(4)
Load
ZD
ZD:VZ = 36 V
10 to
30 VDC
Light indicator Brown (1)
(Mode selec-
tion)
Blue
(see note)
(3)
Pink (2)
PNP
pre-wired E3F2-7B4
E3F2-7B4-M
E3F2-7B4-C
E3F2-7B4-S
E3F2-R2B4
E3F2-R2RB4-M
E3F2-R2RB4-C
E3F2-R2RB4-S
E3F2-DS10B4-N
E3F2-DS10B4-M
E3F2
-
DS10B4
-
C
Connect the
pink and
brown wires
or open the
pink wire.
ON when
light is
incident.
(Light-ON) Main
circuit
Light indicator
Red 100 mA max.
(control
output)
Blue
Black
Load
ZD
Brown (1) (see note)
(Mode selection)
ZD:VZ = 36 V
10 to
30 VDC
(4)
(3)
Pink (2)
E3F2
-
DS10B4
-
C
E3F2-DS10B4-S
E3F2-DS30B4
E3F2-DS30B4-M
E3F2-DS30B4-S
Connect the
pink and
blue wires.
ON when
light is in-
terrupted.
(Dark-ON)
(Mode selection)
100 mA max.
(control
output)
Blue
Black
Load
ZD
Main
circuit
Light indicator
Red
Brown (1) (see note)
10 to
30 VDC
ZD:VZ = 36 V
Pink
(4)
(3)
(2)
NPN
connector E3F2-7C4-P1
E3F2-7C4-M1-M
E3F2-7C4-M1-C
E3F2-7C4-M1-S
E3F2-R2C4-P1
E3F2-R2RC4-M1
-M
E3F2-R2RC4-M1
-C
E3F2-R2RC4-M1
-S
E3F2-DS10C4-
P1
Connect the
pink and
brown wires
or open the
pink wire.
ON when
light is
incident.
(Light-ON) Load
Brown (1) (see note)
100 mA max.
(control output)
Black
(4)
Main
circuit
Light indicator
Red
(Mode selec-
tion)
ZD
10 to
30 VDC
ZD:VZ = 36 V
Pink (2)
Blue (3)
P1
E3F2-DS10C4-
M1-M
E3F2-DS10C4-
M1-C
E3F2-DS10C4-
M1-S
E3F2-DS30C4-
P1
E3F2-DS30C4-
M1-M
E3F2-DS30C4-
M1-S
Connect the
pink and
blue wires.
ON when
light is in-
terrupted.
(Dark-ON)
100 mA max.
(control output)
Main
circuit
Red
Blue
Black
(4)
Load
ZD
ZD:VZ = 36 V
10 to
30 VDC
Light indicator Brown (1)
(Mode selec-
tion)
Pink (2)
Blue
(see note)
(3)
Note: Terminal numbers are for connector types.
(This table continues on the next page.)
E3F2 E3F2
9
Operation Table – continued from previous page
Configuration Model Connection
method Output
transistor Output circuit
PNP
connector E3F2-7B4-P1
E3F2-7B4-M1-M
E3F2-7B4-M1-C
E3F2-7B4-M1-S
E3F2-R2B4-P1
E3F2-R2RB4-M1
-M
E3F2-R2RB4-M1
-C
E3F2-R2RB4-M1
-S
E3F2-DS10B4-
P1
Connect the
pink and
brown wires
or open the
pink wire.
ON when
light is
incident.
(Light-ON) Main
circuit
Light indicator
Red 100 mA max.
(control
output)
Blue
Black
Load
ZD
Brown (1) (See Note.)
(Mode selection)
ZD:VZ = 36 V
10 to
30 VDC
(4)
(3)
Pink (2)
P1
E3F2-DS10B4-
M1-M
E3F2-DS10B4-
M1-C
E3F2-DS10B4-
M1-S
E3F2-DS30B4-
P1
E3F2-DS30B4-
M1-M
E3F2-DS30B4-
M1-S
Connect the
pink and
blue wires.
ON when
light is in-
terrupted.
(Dark-ON)
(Mode selection)
100 mA max.
(control
output)
Blue
Black
Load
ZD
Main
circuit
Light indicator
Red
Brown (1) (See Note.)
10 to
30 VDC
ZD:VZ = 36 V
Pink
(4)
(3)
(2)
AC switching E3F2-3Z1
E3F2-R2Z1
E3F2-DS10Z1-N
--- (Fixed) ON when
light is
incident.
(Light-ON) Main
Load
Light indicator Brown
E3F2-3Z2
E3F2-R2Z2
E3F2-DS10Z2-N
ON when
light is in-
terrupted.
(Dark-ON)
200 mA max.
(control output)
Main
circuit
Red
Blue
Black 24 to
240 VAC
Blue
Note: Terminal numbers are for connector types.
TIMING CHART
Light-ON Mode Dark-ON Mode
Light indicator
(red)
Control
output
Load
(relay)
ON
OFF
ON
OFF
Operate
Release
Light indicator
(red)
Control
output
Load
(relay)
ON
OFF
ON
OFF
Operate
Release
Incident
Interrupted Incident
Interrupted
Terminals/Connections
12
3 4
Output
0 V
VccMode selector
E3F2
E3F2
10
Dimensions
Unit: mm (inch)
PRE-LEADED DC MODELS
Emitter
(or receiver on
through-beam)
16.8 dia.
Diffuse and Retroreflective (DC)
Polyvinyl chloride-covered cord, 4-mm dia. (18/0.12),
4-conductor (brown, blue, black, and pink)
Standard length: 2 m
M18 x 1
5 dia.
Receiver
Sensitivity adjuster on
DS 30 diffuse models only
Light indicator
65 (2.56)
42.3 (1.67)
37 (1.46)
49.3 (1.94)
6.2
(0.24)
22
(0.87) 8
(0.31)
24
(0.94)
3.1
(0.12)
Through-beam (DC)
Emitter: Polyvinyl chloride-covered cord, 4-mm dia.
(18/0.12), 2-conductor (brown and blue)
Standard length: 2 m
Receiver: Polyvinyl chloride-covered cord, 4-mm dia.
(18/0.12), 4-conductor (brown, blue, black,
and pink)
Standard length: 2 m
E3F2-74-
E3F2-DS104-
E3F2-DS304
E3F2-R24
E3F2-R2R4-
E3F2-7L-P1
E3F2-7D-P1
E3F2-7C4-P1, -M1-
E3F2-DS104-P1, -M1
E3F2-DS304-P1, -M1
E3F2-R2-P1
E3F2-R2R-M1-
Optical axis
Lens
Light indicator
Nameplate
10.5 dia. 16.8 dia.
CONNECTOR DC MODELS
Sensitivity adjuster on
DS 30 diffuse models only
5 dia.
6 dia.
M12 x 1
M18 x 1
16.8
8.2
12.4
(0.49) 6.2
22
(0.87) 584
42.3 (1.67)
37 (1.46)
49.3 (1.94)
A
B
24
(0.94)
Metal body Plastic body
E3F2-DS-1 E3F2-DS304-P1
A76 (2.99) 73 (2.87)
B65.5 (2.58) 61.7 (2.43)
E3F2 E3F2
11
AC MODELS
E3F2-3Z1, E3F2-3Z2
E3F2-R2Z1, E3F2-R2Z2
E3F2-DS10Z1-N,
E3F2-DS10Z2-N 24
(0.95)
90 (3.54)
67.3 (2.65)
62 (2.44)
M18 x 1
584
Light indicator
5 dia.
Diffuse and Retroreflective (AC)
Vinyl insulated round cord, 4-mm dia. (11/0.16),
3-conductor (brown, blue, and black)
Standard length: 2 m
16.8 dia.
Receiver
Emitter
22
(0.87)
6.2
(0.24)
3.1
(0.12)
Through-beam (AC)
Emitter: Polyvinyl chloride-covered cord, 4-mm
dia. (11/0.16), 2-conductor (brown and
blue)
Standard length: 2 m
Receiver: Polyvinyl chloride-covered cord, 4-mm
dia. (11/0.16), 3-conductor (brown,
blue, and black)
Standard length: 2 m
ACCESSORIES
E39-R1 Reflector (included with retroreflective units) E39-L7 Reflector Adapter (order separately)
7.5 (0.30)
2.7 (0.11) 34 (1.34)
7 (0.28)
1.6
(0.06)
52
(2.05) 59.9
(2.36)
8 (0.31)
39.3 (1.55)
34 (1.34)
52
(2.05)
59
(2.32)
2-M3
Nut (M5)
12
(0.47)
M5
Spring washer (M5)
2-3.5 (0.14)
dia.
E39-R3 Reflector (order separately)
34.8
(1.37)
Two, M3
Adhesive
side
Two, M3
34
(1.34)
R25.4
Two, 3.2 dia.
14°
13.7
R20
4.5
(0.18)
3.4
Mounting Bracket for E39-R3
(included with E39-R3)
11
(0.43)
0.2
(0.008)
38
(1.50)
1.2 (0.05)
2.6
(0.10)
19.3
(0.76)
29 (1.14)
25.4±0.1
3.4
(0.14)
28
(1.10)22.9
(0.90)
11
16 (0.63)
20
(0.79)0.2
1.2
1.2
(0.05)
38
(1.50)
20
(0.79)
7
0.2
10.1
41.8
(1.65)
25.4
(1.00)
34
(1.34)
10°
18.45
E3F2
E3F2
12
E39-RSA Reflector E39-RSB Reflector
35 (1.38)
33 (1.30)
8
0.7 (0.03)
Four, R1 Adhesive
tape
Reflecting
surface
0.7 (0.03)
Four, R1
33
(1.30)
40 (1.57)
38 (1.50)
Adhesive
tape
Reflecting
surface
35
(1.38)
10 (0.39)
16.0 (0.63)
15.7 (0.62)
6.1
(0.24)
9.2
(0.36)
5-40 SUS set screw
45°x0.5 all around
M18x1 internal threads 22.0 (0.87)
45°
3.0 (0.12)
3.3 (0.13)
18.5 (0.73) 8.9 (0.35)
6x2 mm
30 TYP.
10.6 (0.42)
4.0 (0.16)
23.9 (0.94)
20.5 (0.81)
28.7 (1.13)
14.1
(0.56)
24.6 (0.97)
E39-RU1 Right Angle Adapter
Mounting E39-RU1
Do not exceed a torque value of 20 kg cm (2.0 N m, 17.4 in lbs) when tightening the adapter onto the sensor.
Use a 1/16” (1.5 mm) hex key on the set screw to secure the adapter to the E3F2. Do not exceed a torque of 3.5 kg cm (0.35 N m, 3.0
in lbs). When set properly, the set screw will still extend beyond the adapter wall. Make sure to loosen the set screw before removing the
adapter from the sensor.
E3F2 E3F2
13
Y92E-B18 Mounting Bracket
E39-F31 Lens Cap
Note: Hexagonal nut: M5 x 32
Material: plastic
32±0.2
(1.26±0.008)
17 (0.67) max.
7 (0.28)
30
(1.18)
47 (1.85) max.
20 (0.79) dia.
4 (0.16) max.
Metal rim Gasket E3F2
Glass plate
18 (0.71)
dia.
OPTIONAL CONNECTOR CABLES
Viewed from
pinside of
connector
Straight Connector Cable
Terminals/Connections Connector
Cable
Brown Pin 1 VDC
Black Pin 4 Output
Blue Pin 3 0V
Note: Water tightness with connector is only valid when authorized connections are
used. Cordset wire colors are shown in parentheses.
Assembly Directions
Insert the M12 threaded end of the
sensor into socket of connector so
that the notch correctly aligns the
pins. Tighten the coupling nut by
hand, not using a tool, until all the
threads on the rear of the sensor
are covered. This assures a posi-
tive connection, important for instal-
lations with vibration.
Right Angle Connector Cable
22 AWG, PVC jacketed cable rated for 300 V, 90°C:
2 m (6.56 ft) length for Y96E-44SD2
5 m (16.40 ft) length for Y96E-44SD5
10 m (32.81 ft) length for Y96E-44SD10
22 AWG, PVC jacketed cable rated for 300 V, 90°C:
2 m (6.56 ft) length for Y96E-44RD2
5 m (16.40 ft) length for Y96E-44RD5
10 m (32.81 ft) length for Y96E-44RD10
Silver-plated
copper contacts Aluminum
coupling nut
14.67
(0.58) 26.65
(1.05)
Note: Cable may be extended to a maximum of 200 m (656 ft.)
14.67
(0.58) 34.92
(1.37)
Silver-plated
copper contacts
Aluminum
coupling nut
Pink (White) Pin 2
Mode Selection
123
4
1
3
max. 100 mA
10–30 VDC
to Light-ON
to Dark-ON
Pin configuration NPN
123
4
1
3
max. 100 mA 10–30 VDC
to Light-ON
to Dark-ON
Pin configuration PNP
Y96E-44SDY96E-44RD
Viewed from
pinside of
connector
0
0
E3F2
E3F2
Precautions
If the input/output lines of the Photoelectric Sensor are placed in
the same conduit or duct as power lines or high-voltage lines, the
Photoelectric Sensor could be induced to malfunction, or even be
damaged, by electrical noise. Separate the wiring, or use
shielded lines as input/output lines to the Photoelectric Sensor.
Do not subject the Photoelectric Sensor to excessive shock when
mounting, in keeping with IEC60529 IP66 standards.
Do not connect the black wire to the brown wire without a load.
Direct connection of these wires may damage the Photoelectric
Sensor (AC switching type).
Black
Brown
Blue
Load
Sensor 24 to 240 VAC
WARNING
The E3F2 Photoelectric Sensor is not a safety component for
ensuring the safety of people which is defined in EC Directive
(91/368/EEC) and covered by separate European standards
or by any other regulations or standards.
When using the Photoelectric Sensor in the vicinity of an inverter
motor, be sure to connect the ground wire of the motor to earth.
Failure to ground the motor may result in malfunction of the
Sensor.
When using the Photoelectric Sensor at temperatures over 45°C,
the load current must be within the rated value shown in the
figure below.
Operating temperature (°C)
200
130
5545
0
Load current (mA)
MOUNTING
Do not exceed a torque of
2.0 N m {20 kgf cm} 17.7 in lb when tightening mounting nuts
for plastic models.
20.0 N m {200 kgf cm} 177 in lb when tightening mounting
nuts for metal models.
Cat. No. CEDSAX3 10/99 Specifications subject to change without notice. Printed in U.S.A.
OMRON ELECTRONICS, INC.
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
!