6
Residential Electrical Metering
www.GEDigitalEnergy.com
Product Characteristics I-210+ Basic Energy I-120+c
1Meter Functionality • Real Energy Consumption Management • Real Energy Consumption Management
• Reactive Energy Consumption Measurement
• Apparent Energy Consumption Measurement
• Voltage Measurement (Min, Avg, Max)
• Sag/Swell Measurement
• Outage Count and Duration
2ANSI Models Form Class Volts
1S 100 120 & 240
2S 200 & 320 240
3S & 3CS 20 120 & 240
4S 20 240
12S 200 & 320 120 & 240
25S 200 & 320 120 & 240
Form Class Volts
1S 100 120 & 240
2S 200 & 320 240
3S & 3CS 20 120 & 240
4S 20 240
12S 200 & 320 120 & 240
25S 200 & 320 120 & 240
3Soft-Switches to
upgrade meter function
• Optional Softswitches can be loaded in the factory or by the
user to activate advanced functions
O — Activates communication capability with AMR/AMI modules
S2 — AMI/AMR calculated demand displayed on meter LCD
V2 — Simple Voltage Event monitor in addition to a display of
RMS momentary voltage on the 3 lower LCD digits
• Optional Soft-switches can be loaded in the factory or by the user
to activate advanced functions
A2 — Activates communication capability with AMR/AMI modules
E2 — Activates Event Log Recording (up to 200 Events)
K2 — Activates Reactive/Apparent Energy Consumption recording
N2 — Activates Demand
Q2 — Activates Power Quality (Min, Avg, Max Voltage) recording
R2 — Activates LP recording (up to 4 channels)
T2 — Activates TOU recording
V2 — Activates Sag/Swell monitor and recording
4AMR Interface
(Factory enabled or installed by customer)
• Quadrature Pulse
• SPI Format-1 data
• SPI Format-2 data
• PSEM Communications
• PSEM Communications
5Energy Accumulation • Must specify at time of order either:
- Delivered only
- Delivered + Received
- Delivered – Received
- Received only
• Customer can change selection later using
MeterMate
• Specified at time of order for factory programmed meters or
configured by the customer using MeterMate. Any two or four of
the following energy measurements can be selected:
- Delivered only kWh
- Received only kWh
- Delivered + received kWh
- Delivered – received kWh
- Lagging only kvarh; requires K2 Soft-switch
- Leading only kvarh; requires K2 Soft-switch
- Lagging + Leading kvarh; requires K2 Soft-switch
- Lagging - Leading kvarh; requires K2 Soft-switch
- Phasor apparent VAh; requires K2 Soft-switch
6Cycle Insensitive
Demand
• Not available Requires T2 & N2 Soft-switches to be enabled
• Provides an alternative method for calculating the maximum
demand in meters equipped with one-way AMR system.
• The meter maintains the daily maximum demands and the two
peaks for the period.
• Demand is calculated using the programmed method (Block,
rolling or thermal).
• The daily maximum demands are stored in a circular queue.
• Each entry in the circular queue contains a date.
7Power Quality • With V2 Softswitch enabled, provides a count of Sag/Swell
Events. Value and duration thresholds are programmable.
• With Q2 and R2 Softswitches enabled, Min, Max and Average
Voltage recording is possible.
• With V2 Softswitch enabled, provides counts and magnitude
recording of Sag/Swell Events with date and time stamped.
Value and duration thresholds are programmable. This Sag/
Swell Event Log is separate from the Event Log recording
provided by the E2 Softswitch
• With E2, R2 and T2 Softswitches enabled, recording of sustained
and total outage counts and duration is possible to permit
calculation of IEEE Reliability indices.
8MeterMate Reading and Programming access • Available • Available
9Service Switch
(provide remote controllable disconnection
and reconnection of electrical service for
residential applications)
• A switching device intended to provide remote controllable
disconnection and reconnection of electrical service for
residential applications.
• Factory installed option, specify at time of order.
• Full functionality requires two-way AMI module
• Switch is installed under standard size cover
• Typical applications include:
- Remote disconnect and reconnect of service
- Energy conservation demand limiting
- Demand limiting as an alternative to service disconnection
- Prepayment metering
- Outage management/restoration
Note: Energy conservation demand limiting and prepayment
metering functionalities are not available on forms 12S and 25S.
• A switching device intended to provide remote controllable
disconnection and reconnection of electrical service for
residential applications.
• Factory installed option, specify at time of order.
• Full functionality requires two-way AMI module
• Switch is installed under standard size cover
• Typical applications include:
- Remote disconnect and reconnect of service
- Energy conservation demand limiting
- Demand limiting as an alternative to service disconnection
- Prepayment metering
- Outage management/restoration
Residential Meter Selector