32.28.02
FS6312-71
FS6312-71FS6312-71
FS6312-71
Three-PLL C l ock Generator IC
Three-PLL C l ock Generator ICThree-PLL C l ock Generator IC
Three-PLL C l ock Generator IC
3.0 Electrical Specifications
Table 3: Absolute Maximum Ratings
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These conditions represent a stress rating only, and functional operation of the device at
these or any other conditions above the operational limits noted in this specification is not implied. Exposure to maximum rating conditions for extended conditions may affect device performance,
functionality, and reliability.
PARAMETER SYMBOL MIN. MAX. UNITS
Supply Voltage, dc (VSS = ground) VDD VSS-0.5 7 V
Input Voltage, dc VIVSS-0.5 VDD+0.5 V
Output Voltage, dc VOVSS-0.5 VDD+0.5 V
Input Clamp Current, dc (V I < 0 or VI > VDD)I
IK -50 50 mA
Output Clamp Current, dc (VI < 0 or VI > VDD)I
OK -50 50 mA
Storage Temperature Range (non-condensing) TS-65 150 °C
Ambient Temperature Range, Under Bias TA-55 125 °C
Junction Temperature TJ150 °C
Lead Temperature (soldering, 10s) 260 °C
Input Static Disc harge Voltage Protection (MIL-STD 883E, Method 3015.7) 2 kV
CAUTION: ELECTROSTATIC SENSITIVE DEVICE
Permanent damage res ulting in a loss of functi onality or performance may occur if this devic e is subjected to a high-energy elec-
trostatic discharge.
Table 4: Operating Conditions
PARAMETER SYMBOL CONDITIONS/DESCRIPTION MIN. TYP. MAX. UNITS
Supply Voltage VDD 3.3V ± 10% 3 3.3 3.6 V
Ambient Operating Temperature Range TA070°C
Output Load Capacit ance CL25 pF