TX
4ds_61022_en_tx: 280114D
2. Specifications
1* This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level].)
2* Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 100 m (By voltage drop 6 V DC 1A)
Contact material Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Rating
Nominal switching capacity Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Max. switching power Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
Max. switching voltage 220V DC
Max. switching current Standard contact: 2 A, AgPd contact: 1 A
Min. switching capacity (Reference value)1* 10A 10mV DC
Nominal operating
power
Single side stable 140 mW (1.5 to 24 V DC), 270 mW (48 V DC)
1 coil latching 100 mW (1.5 to 24 V DC)
2 coil latching 200 mW (1.5 to 24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial) Between open contacts 1,500 V (10160s) (FCC Part 68)
Between contacts and coil 2,500 V (210s) (Telcordia)
Temperature rise (at 20C 68F)Max. 50C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Operate time [Set time] (at 20C 68F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20C 68F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 108 (at 180 times/min.)
Electrical Min. 105 (2 A 30 V DC resistive), 5105 (1 A 30 V DC resistive) (at 20 times/min.)
Conditions Conditions for operation, transport and storage2* Ambient temperature: –40C to +85C (up to 24 V coil) –40F to +185F (up to 24 V coil)
[–40C to +70C (48 V coil) –40F to +158F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 2 g .071 oz
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TX2-5V, 10 pcs.
Operating speed: 180 times/min.
0.2
0.3
0.4
0.5
1.0
2.0
3.0
20 30 50 100 200 300
DC resistive load
0
Contact voltage, V
Switching current, A
1.0 2.0
100
50
30
20
10
0
Switching current, A
No. of operations x10
4
30V DC
resistive load
0
10
100 10,0001,00010
Max.
Max.
Min.
Min.
20
30
40
50
60
70
80
90
100
No. of operations, x104
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage