CMR Series www.murata-ps.com Isolated 0.75W Single and Dual Output Isolated DC/DC Converters 5 5 150 150 CMR0505SA3C CMR0512S3C CMR0515S3C CMR1215S3C 5 5 5 12 5 12 15 15 1kVDC or 3kVDC options `Hi Pot Test' CMR100PC CMR0505SAP3C4 5 5 5 5 Wide temperature performance at full 0.75W load -40C to 85C INPUT CHARACTERISTICS FEATURES Short circuit protection options UL 60950 recognised Single or Dual Isolated Outputs Industry Standard Pinouts 5V, 12V and 24V Inputs 5V, 12V and 15V Outputs Pin compatible with NMR, MER1, MMV, MEV1, NMK, MEV3, NMV series. Parameter Voltage range Input short circuit current Input reflected ripple current DESCRIPTION The CMR series are a cost effective 0.75W DC/DC converter series, in an industry standard package with industry standard pinouts, Popular input and output voltages are available as a lower power alternative to a 1W DC/DC converter. The galvanic isolation allows the device to be configured to provide an isolated negative rail in systems where only positive rails exist. The wide temperature range guarantees startup from -40C and full 0.75 watt output at 85C. For the short circuit protected parts (PC) protection is continuous and auto-resetting on removal of the short circuit. MTTF1 5 24 Isolation Capacitance CMR100C CMR118C mV p-p % Typ. Max Typ. Max. Efficiency mA Input Current at rated load Output Current V Ripple & Noise3 Output Voltage V Order Code Load Regulation Nominal Input Voltage SELECTION GUIDE mA % Min. Typ. pF MIL. Tel. kHrs 9 11 6 10 218 6.8 10 8 15 46 3kVDC Isolation Options 150 9 11 15 25 220 31 5 6 6.7 8 192 25 4 6 6.3 8.2 188 25 3 4.5 6.5 13 80 Short Circuit Protection Options 150 7.5 9 10 25 200 150 7.5 9 20 40 195 65 65 69 70 30 60 1850 1250 64 74 76 76 68 78 79 79 30 30 30 40 4240 1560 1060 925 73 74 75.5 76 22 20 3095 61060 2680 56444 Conditions Min. Typ. Max. Units Continuous operation, 5V input types Continuous operation, 12V input types Continuous operation, 24V input types Short circuit variants CMR100PC CMR0505SAP3C 5V & 12V input types 24V input types 4.5 10.8 21.6 5 12 24 95 2 5 2.6 10 5.5 13.2 26.4 V 15 15 4 15 mA p-p Typ. Max. Units 0.75 W 1.15 1.0 1.2 1.2 %/% Typ. Max. Units mA OUTPUT CHARACTERISTICS Parameter Conditions Rated Power2 Voltage Set Point Accuracy TA=-40C to 85C See tolerance envelope High VIN to low VIN ; Short circuit types High VIN to low VIN ; All other output types Line regulation Min. ISOLATION CHARACTERISTICS Parameter Isolation voltage Resistance Conditions Min. C versions flash tested for 1 second 3C versions flash tested for 1 minute Viso=1000VDC 1000 3000 10 VDC G ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 5V input types 12V input types 24V input types 260C 7V 15V 28V 1. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 2. See derating graph. 3. See ripple & noise characterisation method. 4. 3kVDC Isolation All specifications typical at TA=25C, nominal input voltage and rated output current unless otherwise specified. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support KDC_CMR.B01 Page 1 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters GENERAL CHARACTERISTICS Parameter Conditions Switching frequency 5V input types 12V input types 24V input types CMR100PC CMR0505SAP3C Min. Typ. Max. 110 120 80 97 88 Units kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage All output types -40 -50 Case Temperature above ambient Cooling 5V output types All other output types 1kVDC short circuit types 3kVDC short circuit types Free air convection Typ. Max. Units 85 125 33 28 18 19 C TOLERANCE ENVELOPES All 5V output types: All other output types: +8% +4% +2% VNOM -4% 10 75 50 25 Output Load Current (%) 100 Output Voltage Output Voltage +10% +3% +2% VNOM -3% 10 25 50 75 100 Output Load Current (%) Short circuit types: Output Voltage +10% +5% +2% VNOM -3% 10 25 50 75 100 Output Load Current (%) The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. www.murata-ps.com/support KDC_CMR.B01 Page 2 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CMR series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1 minute for 3C versions. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" The CMR is recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CMR series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL UL60950 The CMR is recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation. The CMR100C and CMR118C in a maximum still air ambient temperature of 100C as measured at any point on the case of the unit (hotspot). FUSING The CMR Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. CMR100xC: 0.5A CMR118C: 0.12A CMR05xxxx3C: 0.315A CMR12xxxx3C: 1A All fuses should be UL recognized and rated to 125V. File number E151252 applies. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260C for 10 seconds. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs TEMPERATURE DERATING GRAPHS Short Circuit types only. Output Power (W) Output Power (W) All other types. 85C 0.75 Safe Operating Area 0 -40 100 50 0 Ambient Temperature (C) 150 0.75 85C Safe Operating Area 120C 0 -40 100 50 0 Ambient Temperature (C) 150 www.murata-ps.com/support KDC_CMR.B01 Page 3 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters EFFICIENCY VS LOAD CMR100C CMR118C CMR0505SA3C CMR0512S3C CMR0515S3C CMR1215S3C www.murata-ps.com/support KDC_CMR.B01 Page 4 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters EFFICIENCY VS LOAD CMR0505SAP3C 90 90 80 80 70 70 60 60 Efficiency (%) Efficiency (%) CMR100PC 50 40 50 40 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 Load (%) 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110 Load (%) www.murata-ps.com/support KDC_CMR.B01 Page 5 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are shown in the table below. The product series will start into a capacitance of 47F with an increased start time, however, the maximum recommended output capacitance is 10F. CMR100C CMR118C CMR0505SA3C CMR0512S3C CMR0515S3C CMR1215S3C CMR100PC CMR0505SAP3C Typical Start-Up Wave Form Start-up time s 2300 670 1970 11200 16300 11200 360 370 Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1F X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100m at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450 resistor, carbon film, 1% tolerance R2 50 BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - + R1 T1 R2 Y INPUT Output - R LOAD www.murata-ps.com/support KDC_CMR.B01 Page 6 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters APPLICATION NOTES (continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L DC Power Source CMR100C CMR118C CMR0505SA3C CMR0512S3C CMR0515S3C CMR1215S3C CMR100PC CMR0505SAP3C L, H 10 10 22 150 220 220 22 22 Inductor SMD 82103C 82103C 82223C 82154C 82224C 82224C 82223C 82223C C Load DC Through Hole 11R103C 11R103C 11R223C 11R154C 11R224C 11R224C 11R223C 11R223C Capacitor C, F 4.7 4.7 1 0.33 0.33 0.22 1 1 www.murata-ps.com/support KDC_CMR.B01 Page 7 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters EMC FILTERING AND SPECTRA FILTERING The following filter circuit and filter table shows the input filters typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits. L DC C DC C Ceramic capacitor Inductor Part Number CMR100C CMR118C CMR0505SA3C CMR0512S3C CMR0515S3C CMR1215S3C CMR100PC CMR0505SAP3C Capacitor L, H SMD Through Hole C, F 22 82223C 11R223C 1 CMR100C CMR118C CMR0505SA3C CMR0512S3C www.murata-ps.com/support KDC_CMR.B01 Page 8 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters EMC FILTERING AND SPECTRA CMR0515S3C CMR1215S3C CMR100PC CMR0505SAP3C 80 70 60 dBuV 50 40 30 20 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata-ps.com/support KDC_CMR.B01 Page 9 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS C Package 3C Package 19.500.25 [0.7680.010] 6.000.25 [0.2360.010] 10.000.25 [0.3940.010] S 4.100.5 [0.1610.020] 0.500.05 [0.0200.002] 5.08 [0.200] 0.250.05 [0.0100.002] 1 (1.13 [0.044]) 2 4 6 * 2.54 [0.100] (1.93 [0.076]) 12.70 [0.500] *PIN 6 not fitted on single output variants All dimensions in mm (inches) Controlling dimension is mm. All pins on a 2.54 (0.100) pitch and within 0.1 (0.004) of true position from pin 1 at seating plane `S' TUBE OUTLINE DIMENSIONS Weight: 2.1g (C) 2.0g (3C) 1.9g (PC) PIN CONNECTIONS 9.3 [0.366] 12.43 [0.489] 18.0 [0.709] PIN C 1 Dual +VIN +VIN +VIN 2 -VIN -VIN -VIN 4 -VOUT -VOUT -VOUT 5 6 5.0 [0.197] 3C Single 7 +VOUT 0V +VOUT +VOUT Tube Length : 520mm [20.472] 2.0 [0.079]. Tube quantity: 25 Unless otherwise specified all dimensions in mm [inches] 0.55mm [0.022]. www.murata-ps.com/support KDC_CMR.B01 Page 10 of 11 CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters PACKAGE SPECIFICATIONS (continued) RECOMMENDED FOOTPRINT DETAILS C Package 2.54 [0.100] 3C Package x4 HOLES O 0.045 0.039 O 1.15 1.00 [ 2.54 [0.100] ] * * Hole not required for single output variants All dimensions in millimetres 0.25 (inches 0.1) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2016 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_CMR.B01 Page 11 of 11