E Ericsson Internal TABLE OF CONTENTS PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1/1301-BMR6401401+ 00152-EN/LZT146 302 Uen Specification Technical SEC/S/Stella SEC/S/ StellaTAO TAO Approved PKR 4000 series SEC/S/ SEC/S/Stella StellaTAO TAO 1 (1) (3) No. Checked Date (MICJOHN) 2007-09-17 2007-8-23 Rev DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Reference EN/LZT 146 302 R6G R6F November November 2007 2008 F (c) Ericsson Power Modules AB Key Features * Industry standard MacroDensTM footprint 47.8 x 28.1 x max height 8.0 mm (1.88 x 1.11 x max height 0.32 in.) * High efficiency, typ. 83 % at 5.0 Vout full load * 1500 Vdc input to output isolation * Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 * More than 7.2 million hours predicted MTBF at 40oC ambient temperature General Characteristics * * * * * * Over current protection Soft start Remote control Output voltage adjust function Input voltage adjust function Highly automated manufacturing to ensure highest quality * ISO 9001/14001 certified supplier Safety Approvals Design for Environment Meets requirements in hightemperature lead-free soldering processes. Contents General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 3 ............................................................. 4 Product Program 2.1V, 1.5A / 3.2W Electrical Specification PKR 4310 SI 3.3V, 1.5A / 5W Electrical Specification PKR 4510 SI 5.0V, 1.2A / 6W Electrical Specification PKR 4611 SI 12V, 0.6A / 7W Electrical Specification PKR 4713 SI +12V, 0.25A / -12V, 0.25A / 6W Electrical Specification PKR 4621 SI +5.0V, 0.6A / -5.0V, 0.6A / 6W Electrical Specification PKR 4622 SI +5.0V, 0.6A / +3.3V, 0.9A / 6W Electrical Specification PKR 4628 SI Ordering No. ............................................................. 5 ............................................................. 7 ........................................................... 11 ........................................................... 14 ........................................................... 17 ........................................................... 20 ........................................................... 23 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ........................................................... 26 ........................................................... 27 ........................................................... 28 ........................................................... 29 ........................................................... 30 ........................................................... 33 ........................................................... 35 ........................................................... 36 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1/1301-BMR6401401+ Uen Specification Technical SEC/S/ Stella TAO Approved PKR 4000 SEC/S/ Stella series TAO Checked Date (MICJOHN) 2007-09-17 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Ordering Information See Contents for individual product ordering numbers. Suffix S SPB P Ordering No. PKR 4310 SI PKR 4310 SPBI PKR 4310 PI Reliability The Mean Time Between Failure (MTBF) is calculated at full output power and an operating ambient temperature (TA) of +40C, which is a typical condition in Information and Communication Technology (ICT) equipment. Different methods could be used to calculate the predicted MTBF and failure rate which may give different results. Ericsson Power Modules currently uses one method, Telcordia SR332. Predicted MTBF for the series is: - Rev 2 Reference EN/LZT 146 302 R6G R6F November November 2007 2008 F (c) Ericsson Power Modules AB Compatibility with RoHS requirements General Information Option SMD, lead-free surface finish SMD, leaded surface finish Through hole pin 2 (3) No. 7.2 million hours according to Telcordia SR332, issue 1, Black box technique. Telcordia SR332 is a commonly used standard method intended for reliability calculations in ICT equipment. The parts count procedure used in this method was originally modelled on the methods from MIL-HDBK-217F, Reliability Predictions of Electronic Equipment. It assumes that no reliability data is available on the actual units and devices for which the predictions are to be made, i.e. all predictions are based on generic reliability parameters. The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to solder the die in semiconductor packages) Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip resistors) Lead as an alloying element in copper alloy containing up to 4% lead by weight (used in connection pins made of Brass) The exemption for lead in solder for servers, storage and storage array systems, network infrastructure equipment for switching, signaling, transmission as well as network management for telecommunication is only utilized in surface mount products intended for end-users' leaded SnPb Eutectic soldering processes. (See ordering information table). Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, 6 (sigma), and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of our products. Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person's health or life). E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1/1301-BMR6401401+ Uen Specification Technical SEC/S/ Stella TAO Approved PKR 4000 SEC/S/ Stella series TAO 3 (3) No. Checked Date Rev (MICJOHN) 2007-09-17 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W 3 Reference EN/LZT 146 302 R6G R6F November November 2007 2008 F (c) Ericsson Power Modules AB Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL60950, Safety of Information Technology Equipment. IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards: * * * * * * Electrical shock Energy hazards Fire Mechanical and heat hazards Radiation hazards Chemical hazards On-board DC-DC converters are defined as component power supplies. As components they cannot fully comply with the provisions of any Safety requirements without "Conditions of Acceptability". It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable Safety standards and Directives for the final product. Component power supplies for general use should comply with the requirements in IEC60950, EN60950 and UL60950 "Safety of information technology equipment". There are other more product related standards, e.g. IEEE802.3af "Ethernet LAN/MAN Data terminal equipment power", and ETS300132-2 "Power supply interface at the input to telecommunications equipment; part 2: DC", but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL60950. Isolated DC/DC converters It is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem in the input filter or in the DC/DC converter that imposes a short circuit on the input source, this fuse will provide the following functions: * * Isolate the faulty DC/DC converter from the input power source so as not to affect the operation of other parts of the system. Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. The galvanic isolation is verified in an electric strength test. The test voltage (Viso) between input and output is 1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification). Leakage current is less than 1 A at nominal input voltage. 24 V DC systems The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V DC systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 Vdc. If the input power source circuit is a DC power system, the source may be treated as a TNV2 circuit and testing has demonstrated compliance with SELV limits and isolation requirements equivalent to Basic Insulation in accordance with IEC/EN/UL60950. Non-isolated DC/DC regulators The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1 (23) No. 4 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB Absolute Maximum Ratings Characteristics min Tref Operating Temperature (see Thermal Consideration section) TS Storage temperature VI Input voltage Viso Isolation voltage (input to output test voltage) Vtr Input voltage transient (Tp 100 ms) VRC Remote Control pin voltage (see Operating Information section) Vadj Adjust pin voltage (see Operating Information section) Positive logic option typ max Unit -45 +110 C -55 +125 C -0.5 +75 V 1500 Vdc 90 V -5 +40 V -5 +40 V Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Fundamental Circuit Diagram Single output Vadj NOR 1 2 2 Out1 1 +In 4 Rtn 3 TOA RC -In 1 2 Double output (positive output 2) Vadj 1 Out1 2 2 NOR 1 5 3 +In 1 2 Rtn Out2 6 4 TOA RC -In 1 2 Double output (negative output 2) Vadj 1 2 Out1 2 NOR 1 5 3 +In 4 TOA RC -In Rtn 1 2 6 1 2 Out2 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2 (23) No. 5 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 Rev Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB 2.1V, 1.5A / 3.2W Electrical Specification PKR 4310 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit VI Input voltage range 72 V VIoff Turn-off input voltage Decreasing input voltage 30 33.4 36 V VIon Turn-on input voltage Increasing input voltage 32 34.8 38 V 0 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p 70 50 % of max IO 75 max IO 75 50 % of max IO , VI = 48 V 75 max IO , VI = 48 V 75 Efficiency F 2 3.2 W dB % Pd Power Dissipation max IO 1.0 Pli Input idling power IO= 0, VI = 53 V 70 mW PRC Input standby power VI = 53 V (turned off with RC) 34 mW fs Switching frequency 50-100% of max IO VOi Output voltage initial setting and accuracy Tref = +25C, VI = 53 V, IO = 1.15A Output adjust range 1.4 W 412 485 558 kHz 2.07 2.12 2.17 V 2.38 V 2.28 V 1.76 Output voltage tolerance band 10-100% of max IO Idling voltage IO = 0 2.5 3.0 V Line regulation max IO 14 28 mV Load regulation VI = 53 V, 10-100% of max IO 130 185 mV Vtr Load transient voltage deviation -225 +90 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 1 100 us VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time 0.3 0.7 0.9 ms 1.3 2.8 6 ms 1.5 A 2.6 3.1 A 2.7 3.1 A 3 50 mVp-p 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold Vo = 1.9 V, Tref < max Tref Isc Short circuit current Tref = 25C, Output ripple & noise See ripple & noise section, max IO, VO. VOac 2.01 0 Note 1: Output filter according to Ripple & Noise section 2.0 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3 (23) No. 6 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W G (c) Ericsson Power Modules AB 2.1V, 1.5A / 3.2W Typical Characteristics PKR 4310 SI Efficiency Power Dissipation [%] [W] 80 1.5 75 38 V 38 V 1.0 48 V 48 V 70 53 V 53 V 0.5 72 V 72 V 65 0.0 60 0.0 0.5 1.0 0.0 1.5 [A] 0.5 1.0 1.5 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 15 2.0 1.5 10 1.0 Nat. Conv. 5 0.5 0 0.0 20 30 40 50 60 70 80 90 100 [ ] 0.0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. air speed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics [V] 2.50 [V] 2.5 2.40 2.0 38 V 2.30 48 V 53 V 2.20 38 V 1.5 48 V 53 V 1.0 72 V 72 V 0.5 2.10 0.0 2.00 0.0 0.5 1.0 Output voltage vs. load current at Tref = +25C 1.5 [A] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB PKR 4310 SI Shut-down Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Output voltage ripple (20mV/div.) at: Tref = +25C, IO = 1.5 A resistive load, VI = 53 V. Time scale: 2 s/div. 7 Reference 2.1V, 1.5A / 3.2W Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, IO = 1.5 A resistive load, VI = 53 V. 4 (23) No. Shut-down enabled by disconnecting VI at: Top trace: output voltage (0.5 V/div.). Bottom Tref = +25C, IO = 1.5 A resistive load, trace: input voltage (50 V/div.). VI = 53 V. Time scale: 2 ms/div. Output Load Transient Response See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou= 0.684 x (2.38 -- Vo) / ( Vo - Voi) k Eg Increase 4% =>V0 =2.20 Vdc 0.684 x (2.38 -- 2.20) / ( 2.20 -- 2.12) = 1.54 k Output Voltage Adjust Downwards, Decrease: Rod= 2.751 x ( Voi -- Vo) / (Vo --1.75) k Eg Decrease 2% =>V0 = 2.08Vdc 2.751 x ( 2.12 -- 2.08) / (2.08 --1.75)= 0.33 k Output voltage response to load current step-change (0.38-1.13-0.38 A) at: Tref =+25C, VI = 53 V. Top trace: output voltage (200mV/div.). Bottom trace: load current (1 A/div.). Time scale: 0.1 ms/div. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 5 (23) No. Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 Rev Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB 3.3V, 1.5A / 5W Electrical Specification PKR 4510 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max VI Input voltage range 38 V V Turn-off input voltage Decreasing input voltage 30 33.4 36 VIon Turn-on input voltage Increasing input voltage 32 34.8 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p Efficiency 5 67 50 % of max IO 80.0 max IO 80.7 50 % of max IO , VI = 48 V 80.4 max IO , VI = 48 V 80.7 V F 2 0 Unit 72 VIoff 8 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN W dB % Pd Power Dissipation max IO 1.2 Pli Input idling power IO= 0 A, VI =53 V 92 mW PRC 25 mW Input standby power VI = 53 V (turned off with RC) fs Switching frequency 50-100% of max IO VOi Output voltage initial setting and accuracy Tref = +25C, VI = 53 V, max IO Output adjust range 2 W 412 485 558 kHz 3.28 3.30 3.32 V 2.80 3.80 V V Output voltage tolerance band 10-100% of max IO 3.17 3.50 Idling voltage IO = 0 A 3.40 4.0 V Line regulation max IO 3 13 mV Load regulation VI = 53 V, 10-100% of max IO 90 220 mV Vtr Load transient voltage deviation ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 1 VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time mV 0.07 ms 0.25 0.8 1.2 ms 1 3 9 ms 1.50 A 2.35 3.30 A 2.40 3.50 A 4 50 mVp-p 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold VO = 2.5 V, Tref < max Tref Isc Short circuit current Tref = 25C Output ripple & noise See ripple & noise section, max IO, VOi VOac -190 +100 0 Note 1: Output filter according to Ripple & Noise section 1.65 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 6 (23) No. 9 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W G (c) Ericsson Power Modules AB 3.3V, 1.5A / 5W Typical Characteristics PKR 4510 SI Efficiency Power Dissipation [%] [W] 85 2.0 1.5 80 38 V 38 V 48 V 75 48 V 1.0 53 V 53 V 72 V 70 72 V 0.5 0.0 65 0.0 0.5 1.0 0.0 1.5 [A ] 0.3 0.5 0.8 1.0 1.3 1.5 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 1.8 3.0 m/s 21 19 1.5 2.5 m/s 1.2 0.9 17 2.0 m/s 15 1.5 m/s 13 0.6 1.0 m/s 0.3 Nat. Conv. 0.0 11 9 7 5 0 20 40 60 80 100 [ ] 0.0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Output Characteristics 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Current Limit Characteristics [V] [V] 3.50 3.50 3.00 3.45 38 V 3.40 3.30 38 V 2.00 48 V 53 V 1.50 53 V 72 V 1.00 48 V 3.35 2.50 72 V 0.50 0.00 3.25 0.0 0.5 1.0 Output voltage vs. load current at Tref = +25C 1.5 [A] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB PKR 4510 SI Shut-down Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Output voltage ripple (20mV/div.) at: Tref = +25C, IO = 1.5 A resistive load, VI = 53 V. Time scale: 2 s/div. 10 Reference 3.3V, 1.5A / 5W Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, IO = 1.5 A resistive load, VI = 53 V. 7 (23) No. Shut-down enabled by disconnecting VI at: Top trace: output voltage (1 V/div.). Bottom Tref = +25C, IO = 1.5 A resistive load, trace: input voltage (20 V/div.). VI = 53 V. Time scale: 0.5 ms/div. Output Load Transient Response See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou= 0.495 x (3.93 -- VO)/(VO - VOI)k E.g. Increase 4% =>Vout = 3.43 Vdc 0.495 x (3.93 -- 3.43)/( 3.43 -- 3.3) = 1.9 k Output Voltage Adjust Downwards, Decrease: Rod= 1.986 x (VOI -- VO)/(VO -- 2.59)k E.g. Decrease 2% =>Vout = 3.23 Vdc 1.986 x (3.3 -- 3.23)/(3.23 -- 2.59) = 0.217 k Output voltage response to load current step-change (0.38-1.13-0.38 A}) at: Tref =+25C, VI = 53 V. Top trace: output voltage (200mV/div.). Bottom trace: load current (1 A/div.). Time scale: 0.1 ms/div. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 8 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 Rev 11 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB 5.05V, 1.2A / 6W Electrical Specification PKR 4611 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO, unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit VI Input voltage range 72 V VIoff Turn-off input voltage Decreasing input voltage 30 33.4 36 V VIon Turn-on input voltage Increasing input voltage 32 35.1 38 V 0 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p 68 50 % of max IO 83 max IO 84 50 % of max IO , VI = 48 V 83 max IO , VI = 48 V 84 Efficiency F 2 6 W dB % Pd Power Dissipation max IO 1.2 Pli Input idling power IO = 0 A, VI = 53 V 0.13 W PRC Input standby power VI = 53 V (turned off with RC) 26 mW fs Switching frequency 50-100% of max IO VOi Output voltage initial setting and accuracy Tref = +25C, VI = 53 V, IO = 0.8 A Output adjust range 485 558 kHz 5.02 5.05 5.08 V 5.80 V 5.25 V 4.30 10-100% of max IO 4.85 Idling voltage IO = 0 A 5.2 Line regulation max IO Load regulation Vtr Load transient voltage deviation ttr Load transient recovery time tr ts 5.5 6.0 V 10 20 mV VI = 53 V, 10-100% of max IO 120 210 mV VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 1 -225 +140 mV 0.15 ms Ramp-up time (from 10-90 % of VOi) Start-up time 0.5 1.0 2.0 ms 1.7 3.0 7.0 ms 1.2 A 1.7 2.1 A 1.8 2.6 A 5 50 mVp-p 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold VO = 4.0 V, Tref < max Tref Isc Short circuit current Tref = 25C Output ripple & noise See ripple & noise section, max IO, VOi VOac W 412 Output voltage tolerance band VO 1.6 0 Note 1: Output filter according to Ripple & Noise section 1.4 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 9 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 12 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB 5.05V, 1.2A / 6W Typical Characteristics PKR 4611 SI Power Dissipation Efficiency [%] 90 [W] 1.5 85 38 V 80 48 V 53 V 75 72 V 70 1.2 38 V 0.9 48 V 0.6 53 V 72 V 0.3 65 0.0 0.2 0.4 0.6 0.8 1.0 0.0 1.2 [A] 0.0 Efficiency vs. load current and input voltage at Tref = +25C. 2.5 m/s 1.2 2.0 m/s 1.0 0.8 1.5 m/s 0.6 0.4 1.0 m/s 0.2 Nat. Conv. 0.0 50 0.6 0.8 1.0 1.2 [A] Thermal Resistance [A] 25 0.4 Dissipated power vs. load current and input voltage at Tref = +25C. Output Current Derating 0 0.2 75 100 [C] [C/W] 21 19 17 15 13 11 9 7 5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Output Characteristics Current Limit Characteristics [V] [V] 5.25 5.00 4.00 5.15 5.05 4.95 38 V 3.00 48 V 2.00 53 V 72 V 4.85 0.0 0.2 0.4 0.6 0.8 1.0 1.2 [A] Output voltage vs. load current at Tref = +25C. 38 V 48 V 53 V 1.00 72 V 0.00 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 [A] Output voltage vs. load current at IO > max IO , Tref = +25C. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB PKR 4611 SI Shut-down Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Output voltage ripple (10mV/div.) at: Tref = +25C, IO = 1.2 A resistive load, VI = 53 V. Time scale: 2 s/div. 13 Reference 5.05V, 1.2A / 6W Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, IO = 1.2 A resistive load, VI = 53 V. 10 (23) No. Shut-down enabled by disconnecting VI at: Top trace: output voltage (1 V/div.). Bottom Tref = +25C, IO = 1.2 A resistive load, trace: input voltage (20 V/div.). VI = 53 V. Time scale: 2 ms/div. Output Load Transient Response See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou= 0.495 x (5.87 -- VO)/(VO -- 5.05) k E.g. Increase 4% =>Vout = 5.25 Vdc 0.495 x (5.87 -- 5.25)/(5.25 -- 5.05) = 1.5 k Output Voltage Adjust Downwards, Decrease: Rod= 1.986 x (5.05 -- VO)/(VO -- 4.12) k E.g. Decrease 2% =>Vout = 4.95 Vdc 1.986 x (5.05 --4.95)/(4.95 -- 4.12) = 0.239 k Output voltage response to load current step-change (0.3-0.9-0.3 A) at: Tref =+25C, VI = 53 V. Top trace: output voltage (200mV/div.). Bottom trace: load current (0.5 A/div.). Time scale: 0.1 ms/div. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 11 (23) No. Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB 12V, 0.6A / 7W Electrical Specification PKR 4713 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max VI Input voltage range 38 V V Turn-off input voltage Decreasing input voltage 30 33.4 36 VIon Turn-on input voltage Increasing input voltage 32 35.1 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p 60 50 % of max IO 86 Efficiency 85 50 % of max IO, VI = 48 V 86 max IO, VI = 48 V 85 Pd Power Dissipation max IO Pli Input idling power IO= 0 A, VI = 53 V PRC Input standby power VI = 53V (turned off with RC) fs Switching frequency 50-100% of max IO VOi Output voltage initial setting and accuracy Vtr ttr tr % 1.75 87 W mW 33 mW 485 558 kHz Tref = +25C, VI = 53 V, 50% of max IO 11.83 12.0 12.18 V 10.2 13.8 (15) V Output voltage tolerance band 10-100% of max IO 11.5 12.5 V Idling voltage IO = 0 A 13.3 Line regulation max IO Load regulation VI = 53V, 10-100% of max IO Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 5 A/s, Load transient recovery time see Note 1 Ramp-up time (from 10-90 % of VOi) Start-up time 18.6 V 60 140 mV 340 650 mV +100 -300 mV 0.30 ms 0.6 0.8 1.0 ms 1 3 12 ms 10-100% of max IO ts (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold VO = 10 V, Tref < max Tref Isc Short circuit current Output ripple & noise VOac 1.25 W dB 412 Output adjust range VO 7 max IO V F 2 0 Unit 72 VIoff 14 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN 0 0.6 A 0.90 1.2 A Tref = 25C 1.2 1.9 A See ripple & noise section, max IO, VOi 10 50 mVp-p Note 1: Output filter according to Ripple & Noise section 0.65 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 12 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 15 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB 12V, 0.6A / 7W Typical Characteristics PKR 4713 SI Efficiency Power Dissipation [%] [W] 90 2.0 1.5 85 38 V 48 V 80 36 V 48 V 1.0 53 V 53 V 72 V 75 70 72 V 0.5 0.0 0.0 0.1 0.2 0.3 0.4 0.5 0.0 0.6 [A] 0.1 0.2 0.3 0.4 0.5 0.6 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [ /W] [A] 0.80 20 3.0 m/s 2.5 m/s 0.60 15 2.0 m/s 0.40 1.5 m/s 10 1.0 m/s 0.20 5 Nat. Conv. 0.00 0 0 20 40 60 80 100 [ ] 0.0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Output Characteristics 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Current Limit Characteristics [V] [V] 12.50 12.50 10.00 12.25 38 V 48 V 12.00 53 V 38 V 7.50 48 V 53 V 5.00 72 V 72 V 11.75 2.50 11.50 0.0 0.1 0.2 0.3 0.4 0.5 0.6 [A] Output voltage vs. load current at Tref = +25C 0.00 0.0 0.5 1.0 1.5 2.0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 13 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB 12V, 0.6A / 7W Typical Characteristics Start-up 16 Reference PKR 4713 SI Shut-down Place your graph here Start-up enabled by connecting VI at: Tref = +25C, IO = 0.6A resistive load, VI = 53V Top trace: output voltage (5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Top trace: output voltage (5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 2 ms/div. Output Load Transient Response Place your graph here Output voltage ripple (10mV/div.) at: Tref = +25C, IO = 0.6 A resistive load, VI = 53 VTime scale: 2 s/div. Shut-down enabled by disconnecting VI at: Tref = +25C, IO = 0.6A resistive load, VI = 53 V Place your graph here See the filter in the Output ripple and noise section (EMC Specification). Output voltage response to load current step- Top trace: output voltage (200mV/div.). change (0.15-0.45-0.15 A) at: Bottom trace: load current (1 A/div.). Tref =+25C, VI = 53 V Time scale: 0.2 ms/div. Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: To adjust the output voltage upwards, a resistor is connected between pins 8 and 18. Pins 8 and 9 have to be shorted. The output voltage increases when the resistance decreases. The resistance value is given by the equation: Rou= 0.566*(15-Vo)/(Vo-12), (kOhm); Vo is the desired output voltage. Over 13.8V output voltage the input voltage range is limited to 38...65 V. To adjust the output voltage downwards, a resistor is connected between pins 8 and 9. The output voltage decreases when the connected resistance value increases. The resistance value is given by the equation: Rod= 2.284*(12-Vo)/(Vo-9.52), (kOhm), Vo is the desired output voltage. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 14 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB +12V, 0.25A / -12V, 0.25A / 6W Dual, Electrical Specification PKR 4621 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO, unless otherwise specified under Conditions. Characteristics Conditions min typ max VI Input voltage range 38 V V Turn-off input voltage Decreasing input voltage 30 33.4 36 VIon Turn-on input voltage Increasing input voltage 32 35.7 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p 66 IO1 = 0.12 A, IO2 = 0.12 A 86 IO1 = 0.12 A, IO2 = 0.12 A 86 IO1 = 0.12 A, IO2 = 0.12 A, VI = 48 V 86 IO1 = 0.25 A, IO2 = 0.25 A, VI = 48 V 86 Efficiency 0 6 Power Dissipation IO1 = IO2 = 0.25 A 1.0 Pli Input idling power IO= 0 A, VI =53 V 100 PRC Input standby power VI = 53 V (turned off with RC) fs Switching frequency IO1 = IO2 = 0.12...0.25 A % 1.3 32 412 mW 485 558 kHz Output 2 typ max Tref = +25C, VI = 53 V, IO1 = IO2 = 0.15 A, see Note 2, 3 11.83 12.0 12.18 10.2 13.8 10.2 13.8 V Output voltage tolerance band 10-100% of max IO 11.5 12.5 11.4 12.6 V Idling voltage IO = 0 20 13 Line regulation IO1 = IO2 = 0.25 A Output voltage initial setting and accuracy Load regulation output 1 Load regulation output 2 Vtr Load transient voltage deviation ttr Load transient recovery time tr Ramp-up time (from 10-90% of VOi) Start-up time 13 VI = 53 V, IO1 = 0.025...0.25 A, IO2 = 0.25 A VI = 53 V, IO2 = 0.025...0.25 A, IO1 = 0.25 A IO1 = IO2 = 0.025...0.25 A (from VI connection to 90% of VOi) Output current Ilim Current limit threshold Isc Short circuit current Tref = 25C Output ripple & noise See ripple & noise section, max IO, VOi 23 90 340 470 typ max 12.0 22 V 20 V 80 mV mV -210 +56 455 -200 +56 0.2 mV mV 0.2 ms 0.4 1.0 2.9 0.4 1.0 2.9 ms 1.5 3.2 7 1.5 3.2 7 ms 0.5 0 0.5 A 0.76 1.1 0.35 0.76 1.1 A 1.1 1.7 1.1 1.7 A 6 50 6 50 mVp-p 0 VO = 10 V, Tref < max Tref min 340 VI = 53 V, load step IO1 = 0.1-0.2-0.1 A, IO2= 0.25 A, di/dt = 1 A/s, see Note 1 IO VOac W mW min Output adjust range ts W dB Output 1 VO V F 2 Pd VOi Unit 72 VIoff 17 Reference 0.35 Note 1: Output filter according to Ripple & Noise section Note 2: Output voltage on Output 2 is negative (-12V) Note 3: Can be adjusted to 14.4V. Over 13.8V output voltage, the input voltage range is limited to 38...65V E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 15 (23) No. 18 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W G (c) Ericsson Power Modules AB +12V, 0.25A / -12V, 0.25A / 6W Dual, Typical Characteristics PKR 4621 SI Efficiency Power Dissipation [%] [W] 90 1.25 88 1.00 85 38 V 83 48 V 53 V 80 72 V 78 38 V 0.75 48 V 53 V 0.50 72 V 0.25 0.00 75 0.00 0.05 0.10 0.15 0.20 0.00 0.25 [A ] 0.10 0.15 0.20 0.25[A] Output 1. Dissipated power vs. load current and input voltage at Tref = +25C, I02 = 0.25A. Output 1. Efficiency vs. load current and input voltage at Tref = +25C, I02 = 0.25A. Output Power Derating 0.05 Thermal Resistance [ /W] [W] 6.0 4.0 1.0 m/s 2.0 Nat. Conv. 0.0 0 20 40 60 0.0 100 [ ] 80 18 16 14 12 10 8 6 4 2 0 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Cross regulation Output 1 (+12V) 0.5 Cross regulation Output 2 (-12V) [A] IO 1 [A] IO 1 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.2 0.3 0.4 0.5 Operation area for 4% tolerance at Tref = +25C. 0.6 [A] IO 2 0.0 0.1 0.2 0.3 0.4 0.5 0.6 Operation area for 5% tolerance at Tref = +25C. [A] IO 2 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB PKR 4621 SI Shut-down Top trace: Output 1 (5 V/div.). Mid trace: Output 2 (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Output voltage ripple (10mV/div.) at: Tref = +25C, I01 = I02 = 0.25 A resistive load, VI = 53 V. Time scale: 2 s/div. 19 Reference +12V, 0.25A / -12V, 0.25A / 6W Dual, Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, I01 = I02 = 0.25 A resistive load, VI = 53 V. 16 (23) No. Shut-down enabled by disconnecting VI at: Tref = +25C, I01 = I02 = 0.25 A resistive load, VI = 53 V. Top trace: Output 1 (5 V/div.). Mid trace: Output 2 (5 V/div.). Bottom trace: input voltage (100 V/div.). Time scale: 5 ms/div. Output Load Transient Response See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou = 0.566 x (14.4 -- VO)/(VO -- 12) k E.g. Increase 4% =>Vout = 12.48 Vdc 0.566 x (14.4 -- 12.48)/( 12.48 -- 12) = 2.26 k Output Voltage Adjust Downwards, Decrease: Rod = 2.284 x (12 -- VO)/(VO -- 9.52) k E.g. Decrease 2% =>Vout = 11.76 Vdc 2.284 x (12 --11.76)/(11.76 -- 9.52) = 0.245 k Output voltage response to load current step-change Output 1(0.1-0.2-0.1A) at: Tref =+25C, I02 = 0.25A , VI = 53 V. Top trace: Output 1 (200mV/div.). Mid trace: Output 2 (200mV/div.). Bottom trace: Load current Output 1 (0.1 A/div.). Time scale: 0.1 ms/div. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 17 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB +5.0V, 0.6A / -5.0V, 0.6A / 6W Dual, Electrical Specification PKR 4622 SI Tref = -30 to +85C, VI = 38 to 72 V, pin 8 connected to pin 9 unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO, unless otherwise specified under Conditions. Characteristics Conditions min typ max VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 30 VIon Turn-on input voltage Increasing input voltage 32 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p 64 IO1 = 0.3 A, IO2 = 0.3 A 84 IO1 = 0.6 A, IO2 = 0.6 A 84 IO1 = 0.3 A, IO2 = 0.3 A, VI = 48 V 84 IO1 = 0.6 A, IO2 = 0.6 A, VI = 48 V 84 Efficiency 38 V 32.0 36 V 35.3 38 6 Power Dissipation IO1 = 0.6 A, IO2 = 0.6 A 1.2 Pli Input idling power IO= 0 A, VI =53 V 150 Input standby power VI = 53 V (turned off with RC) fs Switching frequency IO1 = IO2 = 0.3...0.6 A % 1.5 30 412 mW 485 558 Output 2 min typ max 5.02 5.05 5.08 min typ max 5.05 V 4.30 5.80 4.30 5.80 V 4.85 5.25 4.80 5.30 V Idling voltage IO = 0 A 5.1 6.3 5.1 Line regulation IO1 = 0.6 A, IO2 = 0.6 A Load regulation output 2 Load transient voltage deviation ttr Load transient recovery time tr Ramp-up time (from 10-90% of VOi) ts kHz 10-100% of max IO Load regulation output 1 Vtr W mW Output voltage tolerance band Output adjust range VO Tref = +25C, VI = 53 V, IO1 = 0.3 A, IO2 = 0.3 A, see Note 2 W dB Output 1 VOi V F 0 Pd Output voltage initial setting and accuracy Unit 72 2 PRC 20 Reference Start-up time VI = 53 V, IO1 = 0.06...0.6 A, IO2 = 0.6 A VI = 53 V, IO2 = 0.06...0.6 A, IO1 = 0.6 A IO1 = IO2 = 0.025...0.25 A 52 190 300 23 6.3 V 59 mV mV 180 VI = 53 V, load step IO1 = 0.3-0.45-0.3 A, IO2= 0.6 A, di/dt = 1 A/s, see Note 1 (from VI connection to 90% of VOi) 18 80 280 80 0.15 mV mV 0.15 ms 0.1 0.7 1.6 0.1 0.7 1.6 ms 1.5 2.8 7 1.5 2.8 7 ms 1.0 0 1.0 A 1.7 2.4 1.1 1.7 2.4 A IO Output current Ilim Current limit threshold Isc Short circuit current Tref = 25C 1.9 2.9 1.9 2.9 A Output ripple & noise See ripple & noise section, max IO, VOi 11 50 13 50 mVp-p VOac 0 VO = 4.0 V, Tref < max Tref Note 1: Output filter according to Ripple & Noise section Note 2: Output voltage on Output 2 is negative (-5V) 1.1 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 18 (23) No. 21 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB +5.0V, 0.6A / -5.0V, 0.6A / 6W Dual, Typical Characteristics PKR 4622 SI Efficiency Power Dissipation [%] [W] 90.0 1.5 87.5 85.0 38 V 82.5 48 V 1.0 38 V 48 V 53 V 80.0 72 V 77.5 53 V 0.5 72 V 75.0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 [A] 0.0 0.0 0.2 0.3 0.4 0.5 0.6 [A] Output 1. Dissipated power vs. load current and input voltage at Tref = +25C, I02 = 0.6A. Output 1. Efficiency vs. load current and input voltage at Tref = +25C, I02 = 0.6A. Output Power Derating 0.1 Thermal Resistance [ /W] [W] 16 6.0 14 12 4.0 1.0 m/s 10 8 Nat. Conv. 2.0 6 4 2 0.0 0 20 40 60 80 0 100 [ ] 0.0 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Cross regulation Output 1 (+5V) 0.5 Cross regulation Output 2 (-5V) [A] IO 1 [A] IO 1 1.2 1.2 1.0 1.0 0.8 0.8 0.6 0.6 0.4 0.4 0.2 0.2 0.0 0.0 0.0 0.2 0.4 0.6 0.8 1.0 Operation area for 4% tolerance at Tref = +25C. 1.2 [A] IO 2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Operation area for 5% tolerance at Tref = +25C. [A] IO 2 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up 22 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB +5.0V, 0.6A / -5.0V, 0.6A / 6W Dual, Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, I01 = I02 = 0.6 A resistive load, VI = 53 V. 19 (23) No. PKR 4622 SI Shut-down Top trace: Output 1 (2 V/div.). Mid trace: Output 2 (2 V/div.). Bottom trace: Input voltage (50 V/div.). Time scale: 2 ms/div. Shut-down enabled by disconnecting VI at: Top trace: Output 1 (2 V/div.). Tref = +25C, I01 = I02 = 0.6 A resistive load, Mid trace: Output 2 (2 V/div.). Bottom trace: Input voltage (50 V/div.). VI = 53 V. Time scale: 2 ms/div. Output Ripple & Noise Output Load Transient Response Output voltage ripple Output 1 (10mV/div.) at: See the filter in the Output ripple and noise section (EMC Specification). Tref = +25C, I01 = I02 = 0.6 A resistive load, VI = 53 V. Time scale: 5 s/div. Output voltage response to load current step-change Output 1(0.3-0.45-0.3A) at: Tref =+25C, I02 = 0.6 A, VI = 53 V. Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou = 0.495 x (5.87 -- VO)/(VO -- 5.05) k E.g. Increase 4% =>Vout = 5.25 Vdc 0.495 x (5.87 -- 5.25)/(5.25 -- 5.05) = 1.53 k Output Voltage Adjust Downwards, Decrease: Rod = 1.986 x (5.05 -- VO)/(VO -- 4.12) k E.g. Decrease 2% =>Vout = 4.95 Vdc 1.986 x (5.05 --4.95)/(4.95 -- 4.12) = 0.239 k Top trace: Output 1 (100mV/div.). Mid trace: Output 2 (100mV/div.). Bottom trace: Load current Output 1 (0.5 A/div.). Time scale: 0.1 ms/div. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 20 (23) No. 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 23 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB +5.0V, 0.6A / +3.3V, 0.9A / 6W Dual, Electrical Specification PKR 4628 SI Tref = 38 to +85C, VI = 38 to 72 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit VI Input voltage range 72 V VIoff Turn-off input voltage Decreasing input voltage 30 33.4 36 V VIon Turn-on input voltage Increasing input voltage 32 34.9 38 V CI Internal input capacitance PO Output power Output voltage initial setting 0 SVR Supply voltage rejection (ac) f = 100 Hz sine wave, 1 Vp-p 60 IO1 = 0.3 A, IO2 = 0.45 A 82 Efficiency 38 F 2 6 IO1 = 0.6 A, IO2 = 0.9 A 83 IO1 = 0.3 A, IO2 = 0.45 A, VI = 48 V 82 IO1 = 0.6 A, IO2 = 0.9 A, VI = 48 V 83 W dB % Pd Power Dissipation IO1 = 0.6 A, IO2 = 0.9 A 1.3 Pli Input idling power IO= 0 A, VI = 53 V 105 mW PRC Input standby power VI = 53 V (turned off with RC) 30 mW fs Switching frequency IO1 = 0.3...0.6 A, IO2 = 0.45...0.9 A 412 1.4 485 558 Output 1 min VOi Output voltage initial setting and accuracy Output adjust range VO 5.20 min typ max 3.25 3.27 3.29 V 4.43 5.97 2.80 3.80 V 4.94 5.46 3.17 3.42 V Idling voltage IO = 0 A 5.5 6.6 3.5 4.29 V Line regulation IO1 = 0.6 A, IO2 = 0.9 A 25 mV Vtr Load transient voltage deviation ttr Load transient recovery time IO max 10-100% of max IO Load regulation output 2 ts kHz Output 2 Output voltage tolerance band Load regulation output 1 tr Tref = +25C, VI = 53 V, IO1 = 0.6 A, IO2 = 0.9 A typ W VI = 53 V, IO1 = 0.06...0.6 A, IO2 = 0.9 A VI = 53 V, IO2 = 0.09...0.9 A, IO1 = 0.6 A IO1 = 0.6 A, IO2 = 0.9 A (from VI connection to 90% of VOi) Output current Vo1 = 4.0 V, Vo2 = 2.5 V Tref < max Tref 100 148 290 10 mV 145 VI = 53 V, Load step of IO1 = 0.6A 25-75-25%, IO2 = 0.9 A Di/dt = 1 A/s, see Note 1 Ramp-up time (from 10-90% of VOi) Start-up time 28 240 mV -300 +120 -120 +80 mV 150 150 s 0.2 1.1 7 0.1 1.0 6.2 ms 1.6 3.4 8 1.6 3.4 8 ms 0 0.6 1 0 0.9 1 A 1.5 1.6 2.2 1.5 1.6 2.5 A Ilim Current limit threshold Isc Short circuit current Tref = 25C, 2.0 2.8 2.3 3.1 A Output ripple & noise See ripple & noise section, max IO, VOi 20 80 6 50 mVp-p VOac Note 1: Output filter according to Ripple & Noise section. E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 21 (23) No. 24 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date Rev EZYPING 2007-8-27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W (c) Ericsson Power Modules AB +5.0V, 0.6A / +3.3V, 0.9A / 6W Dual, Typical Characteristics PKR 4628 SI Efficiency Power Dissipation [%] [W] 90 1.6 1.4 85 1.2 80 75 38 V 1.0 48 V 0.8 53 V 0.6 72 V 0.4 70 38 V 48 V 53 V 72 V 0.2 0.0 65 0.0 0.1 0.2 0.3 0.4 0.5 0.0 0.6 [A] 0.2 0.3 0.4 0.5 0.6 [A ] Output 1. Dissipated power vs. load current and input voltage at Tref = +25C, I02 = 0.9 A Output 1. Efficiency vs. load current and input voltage at Tref = +25C, I02 = 0.9 A. Output Power Derating 0.1 Thermal Resistance [W] 7.0 [ /W] 6.0 14 16 12 5.0 Nat. Conv. 10 8 4.0 6 3.0 4 2.0 2 0 1.0 0 20 40 60 80 0.0 100 [ ] Output 1. Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Cross regulation output 1 (+5V) 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Cross regulation output 2 (+3.3V) [A] IO 1 [A] IO 1 1.2 1.2 1.0 1.0 0.8 0.8 0.6 0.6 0.4 0.4 0.2 0.2 0.0 0.0 0.0 0.2 0.4 0.6 0.8 1.0 Operation area for 5% tolerance at Tref = +25C. 1.2 [A] IO 2 0.0 0.2 0.4 0.6 0.8 1.0 Operation area for 4% tolerance at Tref = +25C. 1.2 [A] IO 2 E Limited Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Start-up EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 G (c) Ericsson Power Modules AB PKR 4628 SI Shut-down Top trace: Output 1 (2 V/div.). Mid trace: Output 2 (2 V/div.). Bottom trace: Input voltage (50 V/div.). Time scale: 2 ms/div. Output Ripple & Noise Output voltage ripple (20mV/div.) at: Tref = +25C, IO1 = 0.6 A, IO2 = 0.9 A resistive load, VI = 53 V. Time scale: 2 s/div 25 Reference +5.0V, 0.6A / +3.3V, 0.9A / 6W Dual, Typical Characteristics Start-up enabled by connecting VI at: Tref = +25C, IO1 = 0.6 A, IO2 = 0.9 A resistive load, VI = 53 V 22 (23) No. Shut-down enabled by disconnecting VI at: Top trace: Output 1 (2 V/div.). Tref = +25C, IO1 = 0.6 A, IO2 = 0.9 A resistive Mid trace: Output 2 (2 V/div.). load, VI = 53 V. Bottom trace: Input voltage (50 V/div.). Time scale: 2 ms/div. Output Load Transient Response Top trace: Output 1 (20 mV/div.). Bottom trace: Output 2 (20 mV/div.). See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Rou = 0.495 x (3.93 -- VO)/(VO -- 3.27)k E.g. Increase 4% =>Vo = 3.40 Vdc 0.495 x (3.93 -- 3.4)/(3.4 --3.27 ) = 2.02 k Output Voltage Adjust Downwards, Decrease: Rod = 1.986 x (3.27 -- VO)/(VO -- 2.59)k E.g. Decrease 2% =>Vo = 3.20 Vdc 1.986 x (3.27 -- 3.20)/(3.20 -- 2.59) = 0.228 k Output voltage response to load current step-change (0.15-0.45-0.15 A) at: Tref =+25C, VI = 53 V. IO2 = 0.9A resistive load Top trace: Output 2 (200mV/div.). Mid trace: Output 1 (200mV/div.). Bottom trace: load current Output 1 (0.5 A/div.). Time scale: 0.1 ms/div. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1 (5) No. 3/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev 26 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). The fundamental switching frequency is 485 kHz for PKR 4713 SI @ VI = 53 V, max IO. Conducted EMI Input terminal value (typ) Test set-up Layout recommendation External filter (class B) The radiated EMI performance of the DC/DC converter will depend on the PCB layout and ground layer design. It is also important to consider the stand-off of the DC/DC converter. If a ground layer is used, it should be connected to the output of the DC/DC converter and the equipment ground or chassis. Required external input filter in order to meet class B in EN 55022, CISPR 22 and FCC part 15J. A ground layer will increase the stray capacitance in the PCB and improve the high frequency EMC performance. EMI without filter Filter components: C1= 1F 100V C2= 10F 100V C3,C4= 2.2nF 1500Vdc L1= Pulse PO354 1.17mH Output ripple and noise Output ripple and noise measured according to figure below. Output ripple and noise test setup EMI with filter E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Operating information Input Voltage The input voltage range 38...72Vdc meets the requirements of the European Telecom Standard ETS 300 132-2 for normal input voltage range in --48 and --60 Vdc systems, -40.5...-57.0 V and --50.0...-72 V respectively. At input voltages exceeding 72 V, the power loss will be higher than at normal input voltage and Tref must be limited to absolute max +85C. The absolute maximum continuous input voltage is 75Vdc. Turn-off Input Voltage The converters monitor the input voltage and will turn on and turn off at predetermined levels. To increase VIon a resistor should be connected between pin 11 and 17. The resistance is given by the following equation: Rset(up) = 100(X - Von)/(Von - VIon) k To decrease VIon a resistor should be connected between pin 10 and 11. The resistance is given by the following equation: Rset(down) = 370(Von - Y)/(VIon - Von) k Variants/Parameters PKR4310 PKR4510 PKR4611 PKR4713 PKR4621 PKR4622 PKR4628 2 (5) No. X Vion 34.8 96 Y 28.4 35.1 96 28.6 35.7 35.3 34.9 98 96 96 28.9 28.6 28.6 Remote Control (RC) The products are fitted with a remote control function referenced to the primary negative input connection (- In), with positive logic. The RC function allows the converter to be turned on/off by an external device like a semiconductor or mechanical switch. The RC pin has an internal pull up resistor to + In. The maximum required sink current is 0.1 mA. When the RC pin is left open, the voltage generated on the RC pin is <15 V. To ensure that the converter stays off the voltage must be below 1.0V. Input and Output Impedance The impedance of both the input source and the load will interact with the impedance of the DC/DC converter. It is important that the input source has low characteristic impedance. The PKR 4000 Series DC/DC converters are designed for stable operation without external capacitors connected to the input or output. The performance in some Rev 27 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB applications can be enhanced by addition of external capacitance as described under maximum capacitive load. If the input voltage source contains significant inductance, the addition of a 10 F capacitor across the input of the converter will ensure stable operation. The capacitor is not required when powering the DC/DC converter from an input source with an inductance below 10 H. External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the load can be improved by addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic capacitors as close to the load as possible, using several capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load changes while electrolytic capacitors should be used to handle low frequency dynamic load changes. It is equally important to use low resistance and low inductance PCB layouts and cabling. External decoupling capacitors will become part of the control loop of the DC/DC converter and may affect the stability margins. As a "rule of thumb", 100 F/A of output current can be added without any additional analysis. The absolute maximum value of output capacitance is 5 000 F. For further information please contact your local Ericsson Power Modules representative. Output Voltage Adjust (Vadj) All PKR 4000 Series DC/DC converters have an Output Voltage Adjust pin (Vadj). This pin can be used to adjust the output voltage above or below output voltage initial setting. At increased output voltages the maximum power rating of the converter remains the same, and the max output current must be decreased correspondingly. The output voltage can be increased or decreased by means of external resistors or other external circuitry. If other circuitry is used, the slew rate has to be limited to maximum 5 V/ms. To increase the voltage a resistor should be connected between the Vadj pin and +IN. To decrease the output voltage, a resistor is connected between Vadj pin and NOR pin. The resistor value of the Output voltage adjust function is according to information given under the Output section for the respective product. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) 3 (5) No. Checked Date EZYPING 2007-8-27 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev 28 Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB Operating information continued Thermal Consideration Parallel Operation General Paralleling of several PKR 4000 converters is easily accomplished by direct connection of the output voltage terminal pins. The load regulation characteristic is specifically designed for optimal paralleling performance. Load sharing between converters will be within 10%. It is recommended not to exceed PO = n x 0.9 x POmax, where POmax is the maximum converter output power and n the number of paralleled converters, to prevent overloading any of the converters and thereby decreasing the reliability performance. The PKR 4000 series DC/DC converters are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. Cooling is achieved mainly by conduction, from the pins to the PCB board, and convection, which is dependant on the airflow across the converter. Increased airflow enhances the cooling of the converter. Over Current Protection (OCP) The PKR 4000 Series DC/DC converters include current limiting circuitry for protection at continuous overload. The output voltage will decrease towards zero for output currents in excess of max output current (max IO). The converter will resume normal operation after removal of the overload. The load distribution should be designed for the maximum output short circuit current specified. The Output Current Derating graph found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity at Vin = 53V. The DC/DC converter is tested on a 254 x 254 mm, 35 m (1 oz), 8-layer test board mounted vertically in a wind tunnel with a cross-section of 305 x 305 mm. Proper cooling of the DC/DC converter can be verified by measuring the temperature at positions P1. The temperature at this position should not exceed the max values provided in the table below Note that the max value is the absolute maximum rating (non destruction) and that the electrical Output data is guaranteed up to Tref +85C. Position Device Designation max value P1 Transformer Tref 110 C P1 Air Flow E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3/1301-BMR 640Technical 1401+ Uen Specification ESKEVIN Approved PKR 4000 series SEC/D (Julia You) 4 (5) No. Checked Date Rev EZYPING 2007-8-27 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Thermal Consideration continued 29 Reference (c) Ericsson Power Modules AB Connections Definition of reference temperature (Tref) The reference temperature is used to monitor the temperature limits of the product. Temperatures above maximum Tref are not allowed and may cause degradation or permanent damage to the product. Tref is also used to define the temperature range for normal operating conditions. Tref is defined by the design and used to guarantee safety margins, proper operation and high reliability of the module. 18 17 16 15 14 13 12 11 10 1 Ambient Temperature Calculation 2 3 4 5 6 7 8 9 By using the thermal resistance the maximum allowed ambient temperature can be calculated. 1. The power loss is calculated by using the formula ((1/) - 1) x output power = power losses (Pd). = efficiency of converter. E.g 85 % = 0.85 Pin 2. Find the thermal resistance (Rth) in the Thermal Resistance graph found in the Output section for each model. Calculate the temperature increase (T). T = Rth x Pd 3. Max allowed ambient temperature is: Max Tref - T. E.g PKR 4713 SI at 1m/s: Designation Function 1 Out 1 Output 1 2 Rtn Output return 1) 3 Out 2 Output 2 4 NC Not connected 5 NC Not connected 6 NC Not connected 7 NC Not connected 8 Vadj Output voltage adjust 9 NOR Connection of Nominal Output voltage Resistor Turn-on/off input voltage adjust 10 TOA 1. (( 1 ) - 1) x 7 W = 1.24 W 0.85 11 RC 2. 1.24 W x 14.0C/W = 17.3C 12 NC Remote control and turn-on/off input voltage adjust Not connected 13 NC Not connected 14 NC Not connected 15 NC Not connected 16 NC Not connected 17 - In Negative Input 18 +In Positive input 3. 110 C -- 17.3C = max ambient temperature is 92.7C The actual temperature will be dependent on several factors such as the PCB size, number of layers and direction of airflow. 1) Only for duals. Ericsson Internal PRODUCT SPEC. MECHANICAL E Prepared (also subject responsible if other) MICKAOV Approved PKR 4000 series SEC/D (Julia You) 1 (4) No. 4/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Mechanical Information -- Surface Mount Version Rev Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 E (c) Ericsson Power Modules AB 30 Ericsson Internal PRODUCT SPEC. MECHANICAL E Prepared (also subject responsible if other) MICKAOV Approved PKR 4000 series SEC/D (Julia You) 2 (4) No. 4/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Assembly Information -- Surface Mount Version Rev Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 E (c) Ericsson Power Modules AB 31 Ericsson Internal PRODUCT SPEC. MECHANICAL E Prepared (also subject responsible if other) MICKAOV Approved PKR 4000 series SEC/D (Julia You) 3 (4) No. 4/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Mechanical Information -- Hole Mount Version Rev Reference EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 E (c) Ericsson Power Modules AB 32 Ericsson Internal PROD. SPECIFICATION MECHANICAL E Prepared (also subject responsible if other) 1 (5) No. MICKAOV Approved PKR 4000 series SEC/D (Julia You) 5/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Soldering Information - Surface Mounting The surface mount version of the product is intended for convection reflow or vapor phase reflow in SnPb or Pb-free reflow processes. Mounting Options The surface mount version is available in two options, SnPb based or SnAgCu based (Pb-free) solder bumps. The SnPb solder bumps are intended for SnPb solder paste on the host board and to be reflowed in SnPb reflow process temperatures, typically +210 to +220C. The Pb-free solder bumps are intended for Pb-free solder paste on the host board and to be reflowed in Pb-free reflow process temperatures, typically +235 to +250C. Note that recommendations for minimum and maximum pin temperature -- and maximum peak product temperature -- are different depending on mounting option, reflow process type and if the dry packing of the products has been kept intact. General Reflow Profile Recommendations The reflow profile should be optimised to avoid excessive heating of the product. It is recommended to have a sufficiently extended preheat time to ensure an even temperature across the host PCB and to minimize the time in reflow. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board, since cleaning residues may affect long time reliability and isolation voltage. Rev Reference 33 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB Mixed Solder Process Recommendations When using products with Pb-free solder bumps and thereby mixing Pb-free solder with SnPb paste on the host board and reflowing at SnPb process temperatures (backwards compatibility), special recommendations apply. An extended preheat time between +170C and +180C for 60 to 90s and a pin reflow temperature (TPIN) between +220C and +225C for 30 to 60 s is recommended. The extended preheat and soak at reflow temperature will minimize temperature gradients and maximize the wetting and solder mixing in the final solder joints. The use of nitrogen reflow atmosphere will further improve the solder joint quality. Temperature Solder bump Profile 60-90 s 170C to 180C 30-60 s 221C to 225C Time Dry Pack Information Products intended for Pb-free reflow processes are delivered in standard moisture barrier bags according to IPC/JEDEC standard J-STD-033 (Handling, packing, shipping and use of moisture/reflow sensitivity surface mount devices). The SnPb option of this product is also delivered in dry packing. Reflow process specifications1 SnPb eutectic Average ramp-up rate 3C/s max 3C/s max +183C +221C Using products in high temperature Pb-free soldering processes requires dry pack storage and handling. In case the products have been stored in an uncontrolled environment and no longer can be considered dry, the modules must be baked according to J-STD-033. Thermocoupler Attachment Typical solder melting (liquidus) temperature TL Minimum reflow time above TL Pb-free 30 s 30 s Minimum pin temperature TPIN +210C +235C Peak product temperature TPRODUCT +225C +260C 6C/s max 6C/s max Average ramp-down rate Maximum time 25C to peak 6 minutes 8 minutes 1 Note: for mixed SnPb / Pb-free soldering, special recommendations apply Top of PCB near pin 9 or pin 10 for measurement of maximum product temperature, TPRODUCT Temperature TPRODUCT maximum TPIN minimum Pin profile TL Product profile Time in reflow Pin 5 of pin 14 for measurement of minimum pin (solder joint) temperature, TPIN Time in preheat / soak zone Time 25C to peak Time Ericsson Internal PROD. SPECIFICATION MECHANICAL E Prepared (also subject responsible if other) MICKAOV Approved PKR 4000 series SEC/D (Julia You) 2 (5) No. 5/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Reference 34 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB Pin Temperature Recommendations Pin number 5 and 14 are chosen as reference locations for the minimum pin (solder joint) temperature recommendations since these will likely be the coolest solder joints during reflow Surface Mount Assembly and Repair SnPb Solder Processes Assembly Minimum pin temperature: for SnPb solder processes, a pin temperature (TPIN) in excess of the solder melting temperature, (TL, +183C for Sn63Pb37) for more than 30 seconds, and a peak temperature of +210C is recommended to ensure a reliable solder joint. Automatic pick and place equipment should be used to mount the product on the host board. The use of a vision system, utilizing the fiducials on the bottom side of the product, will ensure adequate accuracy. Manual mounting of solder bump products is not recommended. A maximum pin temperature of +225C should be sufficient for most applications but depending on type of solder paste and flux system used on the host board, up to a recommended maximum temperature of +245C could be used, provided that the products are kept in a controlled environment (dry pack handling and storage) prior to assembly. Note that the actual position of the pick up surface may vary between variants within the product program and is not necessarily in the center of the product outline. Pb-free Solder Processes Repair For Pb-free solder processes, a pin temperature (TPIN) in excess of the solder melting temperature (TL, +217 to +221 C for SnAgCu solder alloys) for more than 30 seconds, and a peak temperature of +235C on all solder joints is recommended to ensure a reliable solder joint. For a successful repair (removal and replacement) of a solder bump product, a dedicated rework system should be used. The rework system should preferably utilize a bottom side heater and a dedicated hot air nozzle to heat the solder bumps to reflow temperature. Maximum Product Temperature Requirements Top of the product PCB near pin 9 or 10 are chosen as reference locations for the maximum (peak) allowed product temperature (TPRODUCT), since these will likely be the warmest parts of the product during the reflow process. The product is an open frame design with a pick up surface on a large central component. This pick up surface can not be used for removal with a vacuum nozzle since the component solder joints may have melted during the removal reflow. SnPb Solder Processes For conventional SnPb solder processes, the product is qualified for MSL 1 according to IPC/JEDEC standard J-STD-020C (no dry pack handling or controlled environment required) During reflow, TPRODUCT must not exceed +225 C at any time. If the products are handled as MSL 3 products, they can withstand up to +260C as in Pb-free solder processes. Pb-free Solder Processes For Pb-free solder processes, the product is qualified for MSL 3 according to IPC/JEDEC standard J-STD-020C. The solder bumps of the product require particular care during assembly since the solder bumps are hidden between the host board and the product's PCB. Special procedures are required for successful rework of these products. If necessary, it is recommended to fine tune the solder print aperture size to optimize the amount of deposited solder with consideration to screen thickness and solder print capability. In order not to damage the product and nearby components during removal and replacement with a new product, it is recommended to use a double wall design of the hot air nozzle to direct the air flow only to the edges of the product, see `Assembly Information' in the mechanical drawing. Soldering Information -- Hole Mounting The hole mount version of the product is intended for manual or wave soldering in plated through holes on the host board. When wave soldering is used, the temperature on the pins is specified to maximum +270 C for maximum 10 seconds. A maximum preheat rate of 4C/s and a preheat temperature of max of +150C is suggested. When soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. During reflow, TPRODUCT must not exceed +260 C at any time. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleaning residues may affect long time reliability and isolation voltage. Ericsson Internal PROD. SPECIFICATION MECHANICAL E Prepared (also subject responsible if other) 3 (5) No. MICKAOV Approved PKR 4000 series SEC/D (Julia You) 5/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Reference 35 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB Delivery Package Information The surface mount version of the product is delivered in antistatic injection molded trays (Jedec design guide 4.10D standard) or in antistatic carrier tape (EIA 481 standard) Tray Specifications The hole mount version is delivered in antistatic tubes. Bakability Carrier Tape Specifications Material Polystyrene (PS), antistatic Surface resistivity < 107 Ohm/square Bakability The tape is not bakable Tape width 72 mm [2.835 inch] Pocket pitch 36 mm [1.417 inch] Pocket depth 9.2 mm [0.362 inch] Reel diameter 330 mm [13 inch] Reel capacity 150 products / reel Reel weight Approximately 2.5 kg / full reel Tape feed direction Material PPE, antistatic Surface resistance Tray capacity 105 < Ohm/square < 1012 The trays can be baked at maximum 125 C for maximum 48 hours 15 products / tray Box capacity 150 products (10 full trays / box) Tray weight 140 g empty, 320 g full tray maximum JEDEC standard tray Note: all tray dimensions refer to pocket center. Exact position of pickup point depends on the position of the pickup surface (top of main transformer) of the individual product variant Round holes Pin 1 Elongated holes Tube Specifications Material PVC, transparent with antistatic coating Surface resistance < 1011 Ohm/square Bakability The tubes are not bakable Tube capacity 10 products / tube Box capacity 100 products (10 full tubes / box) Tube weight Typical 160 g full tube Ericsson Internal PROD. SPECIFICATION MECHANICAL E Prepared (also subject responsible if other) 4 (5) No. MICKAOV Approved PKR 4000 series SEC/D (Julia You) 5/1301-BMR 6401 Uen Technical Specification Checked Date See 1 2007-10-08 DC/DC converters, Input 36-75 V, Output up to 1.5 A/7 W Rev Reference 36 EN/LZT 146 302 R6G R6E November R6F September November 2007 2008 2007 D (c) Ericsson Power Modules AB Product Qualification Specification Characteristics External visual inspection IPC-A-610 Operational life test MIL-STD-202G method 108A With power cycling Tref Load Duration According to Absolute maximum ratings Maximum output power 500 h Vibration, broad band random IEC 60068-2-64 Fh Frequency Acceleration spectral density Duration and directions 10 to 500 Hz 0.5 g2/Hz 10 min in each 3 perpendicular directions Vibration, sinusoidal IEC 68-2-64 Fc Frequency Amplitude Acceleration Sweep rate Duration 10 to 500 Hz 0.75 mm 10 g 1 octave/min 2 h in each 3 perpendicular directions Mechanical shock IEC 68-2-27 Ea Peak acceleration Duration Pulse shape Directions Number of pulses 100 g 6 ms Half sine 6 18 (3 + 3 in each perpendicular direction) Change of temperature (Temperature cycling) IEC 60068-2-14 Na Temperature range Number of cycles Dwell time -40 to +100C 300 30 min Robustness of terminations IEC 68-2-21 Ue1 Surface mount products All leads IEC 68-2-21 Ua1 IEC 68-2-21 Ub (5.2b) Through hole mount products All leads IEC 68-2-58 Td Temperature, SnPb Eutectic Temperature, Pb free Preconditioning 215 5C 245 5C 240 h in 85C/85%RH IEC 68-2-58 Ta Temperature, Pb free Solder immersion time Preconditioning 260 5C 5 0.5 s Steam ageing 8 h15 minutes Damp heat IEC 60068-2-67 Cy with bias Temperature Humidity Duration Preconditioning +85 C 85 % RH 500 hours Reflowed 3X according to IPC/JEDEC J-STD-020C MSL3 at 260C Moisture reflow sensitivity classification J-STD-020C SnPb Eutectic Pb free MSL 1, peak reflow at 225C MSL 3, peak reflow at 260C Immersion in cleaning solvents IEC 68-2-45 XA Method 2 Water Isopropyl alcohol Glycol ether +55 5C +35 5C +35 5C Cold (in operation) IEC 68-2-1 Ad Temperature TA Duration -40C 72 h Solderability Surface mount version Solderability Hole mount version