Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment H Series UL Recognized CSA Certified VDE Approved* EH8 EH9 EH4 EH1 H Series EH5 Specifications * Minimal leakage current suitable for medical equipment * Two element circuit provides basic EMI attenuation above 1 MHz * Available with an internal ground circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies * Capacitive output (see EAH, EBH and EJH Series for capacitive input) Ordering Information 3EH1C Ground Circuit Inductor Omit if none Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic LINE Output Styles Chassis Mount Style 1 - .250 [6.3] spade terminals 3 - Wire leads Power Inlet Style * 4 - .250 [6.3] spade terminals (back) 5 - Wire leads (bottom) 8 - Wire leads (back) 9 - .250 [6.3] spade terminals (bottom) H Series Leakage current designation E - Low Leakage (<0.5 mA) Current Rating 3, 6, 10 or 15A 3 2250 VDC 1450 VDC Power Inlet Filters & Power Entry Modules * Flanged mounting the same as the EC, ED and EF Series Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A LOAD 1 Note 1: 10EH4C version only Available Part Numbers 3EH1 3EH3 6EH1 6EH3 6EH4 6EH5 6EH8 6EH9 10EH1 10EH3 10EH4 15EH4 Ground Circuit Inductor Versions 10EH4C *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC *IEC 60320-1 C14 inlet mates with C13 connector 169 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment (continued) H Series Case Styles H1 (Chassis Mount) H5 E A Blue Brown D D E B Green/Yellow C B F C A H3 F (Chassis Mount) H8 F Blue E D B Green/Yellow D E B Brown F A A C C H4 & H4C C D E A B Recommended Panel Cutouts Front Mount .820 20.8 H9 1.200 30.48 1.575 40.01 C .65 Max. 16.5 D E A Back Mount .900 22.9 .140 3.56 .062 R. 1.58 Typ. 1.200 30.48 1.575 40.01 .140 3.56 .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted B 170 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment (continued) H Series Case Dimensions Part No. H1 H3 6EH4 10EH4, 10EH4C 15EH4 H5 H8 A B C F E D Typical Insertion Loss Measured in closed 50 Ohm system 3EH 6EH db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10EH 15EH db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 3 Power Inlet Filters & Power Entry Modules H9 Performance Data 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) FA601: Insulating Shroud .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 1.39 35.4 1.17 29.7 .767 19.5 171 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com