1
Thermal (T- and TA-Line) T11-811
https://www.schurter.com /PG17_20
Circuit Breakers
Circuit Breaker for Equipment thermal, Drop-in type, Reset type, Quick connect terminals
See below:
Approvals and Compliances
Description
- Drop-in type
- Thermal circuit breaker
- 1-pole
- Reset type
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Compact design
- Positively trip-free release
- Available with cover
- Different mounting possibilities
Applications
- Power tools
- Household Equipment
- Power supplies and chargers
- Industrial appliances
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Detailed request for product, Product News
Technical Data
Rated Voltage AC 240 V: 50/60 Hz
Rated Voltage DC 48 V
Rated current range AC 0.05 - 16 A
Conditional short circuit ca-
pacity
IEC: Inc, PC1, AC 240 V: 2 kA
Short circuit capacity Icn at In < 6.5 A/240 VAC : 8 x In
at In 6.5 A/240 VAC : 96 A
Degree of Protection from front side IP 40 acc. to IEC 60529
Dielectric Strength 50 Hz: > 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
Insulation Resistance 500 VDC > 100 MΩ
Endurance typical 2 x Ir: 500 switching cycles
Endurance minimum Reset type
AC : 2 x Ir , cos φ 0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50 switching cycles
Overload IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
Allowable Operation Temp. -5 °C to 60 °C
Vibration Resistance ± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Shock Resistance 100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Tripping Type Thermal
Actuation Type Reset type
Weight ca. 10 g
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: T11
Approval Logo Certificates Certification Body Description
VDE Approvals VDE VDE Certificate Number: 99759
UL Approvals UL UL File Number: E71572
CQC Approvals CQC CCC Certificate Number: 2012010307564692
2
Thermal (T- and TA-Line)
T11-811 https://www.schurter.com /PG17_20
Circuit Breakers
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to IEC 60934 Circuit-breakers for equipment (CBE)
Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment
Designed according to CSA C22.2 No. 235 Supplementary Protectors
Designed according to GB 17701 Circuit-breaker for equipment
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG EU Directive RoHS 2011/65/EU
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Dimension [mm]
15.2
19
11.5
9.0
4
48.2
34.5
11
9.2
44
9Ø4
10
3
12
6.3
T11-811 <7,5A T11-811 >7,5 A T11-811N
3
Thermal (T- and TA-Line) T11-811
https://www.schurter.com /PG17_20
Circuit Breakers
Diagrams
Rated current 7,5 A
1
2
Rated current >7,5 A
1
3
Shunt terminal T11-...N 6,5 A
1
32
Typical internal resistance
Rated Current [A] Internal Resistance []
0.05 380.000
0.50 5.200
1.00 1.350
2.00 0.300
3.00 0.130
4.00 0.080
5.00 0.040
6.00 0.040
7.00 0.020
8.00 0.012
9.00 0.012
10.00 0.011
11.00 0.0095
12.00 0.0095
13.00 0.0085
14.00 0.0085
15.00 0.0075
16.00 0.0075
4
Thermal (T- and TA-Line)
T11-811 https://www.schurter.com /PG17_20
Circuit Breakers
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated cur-
rent for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient Temperature [°C] Correction factor
-5 0.87
0 0.90
+10 0.95
+23 1.00
+30 1.04
+40 1.10
+50 1.15
+60 1.20
Example: Rated current = 5 A, Environmental temperature = 40 °C, --> Correction factor =
1.1, Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
Time-Current-Curves
Time in Seconds
10`000
1,05
60
1085432
1,35
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
30
20
10
5
1
< 6,5 A
> 6,5 A
Multiple of Rated Current In
Reference Temperature +23°
Config. Code
T11|-|1|2|3|A|B|-|1.23|
The characters are placeholders for the correspondingly keys of selections from the key tables.
T11|-| 1 |2|3|A|B|-|1.23| = Mounting
Mounting Configuration
key
Drop-in type 8
T11|-|1| 2 |3|A|B|-|1.23| = Actuation Type
Actuation Type Configuration
key
Reset type 1
T11|-|1|2| 3 |A|B|-|1.23| = Terminal
Terminal Configuration
key
Quick connect terminal 6.3x0.8mm 1
T11|-|1|2|3| A |B|-|1.23| = Shunt terminal
Shunt terminal Configuration
key
Shunt terminal N
5
Thermal (T- and TA-Line) T11-811
https://www.schurter.com /PG17_20
Circuit Breakers
T11|-|1|2|3|A| B |-|1.23| = Setting indication
Setting indication Configuration
key
Setting indication R
T11|-|1|2|3|A|B|-| 1.23 | = Rated current
Rated current Configuration
key
0.05 A 0.05
0.1 A 0.1
0.15 A 0.15
0.2 A 0.2
0.3 A 0.3
0.4 A 0.4
0.5 A 0.5
0.6 A 0.6
0.7 A 0.7
0.8 A 0.8
0.9 A 0.9
1.0 1
1.1 A 1.1
1.2 A 1.2
1.3 A 1.3
1.4 A 1.4
1.5 A 1.5
1.6 A 1.6
1.7 A 1.7
1.8 A 1.8
1.9 A 1.9
Other rated currents on request
Rated current Configuration
key
2.0 A 2
2.1 A 2.1
2.3 A 2.3
2.5 A 2.5
2.8 A 2.8
3.0 A 3
3.3 A 3.3
3.5 A 3.5
4.0 A 4
4.5 A 4.5
5.0 A 5
5.5 A 5.5
6.0 6
6.5 A 6.5
7.0 A 7
7.5 A 7.5
8.0 A 8
8.5 A 8.5
9.0 A 9
9.5 A 9.5
10.0 A 10
11.0 A 11
12.0 A 12
13.0 A 13
14.0 A 14
15.0 A 15
16.0 A 16
Other rated currents on request
Variants
Rated current Construction variants Config. Code Order Number
Shunt terminal Setting indication
3.0 A T11-811-3 4400.0112
5.0 A T11-811-5 4400.0114
5.5 A T11-811-5.5 4400.0120
2.5 A T11-811-2.5 4400.0178
6.0 T11-811-6 4400.0179
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/
Stock-Check-SCHURTER
Packaging Unit 100 Pcs
6
Thermal (T- and TA-Line)
T11-811 https://www.schurter.com /PG17_20
Circuit Breakers
Accessories
Description
T-Line Accessories
Accessories to T-Line
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
11.04.2018
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
4400.0300 4400.0280 4400.0570 4400.0420 4400.0350