USP-225 225W Single Output with PFC Function series Features : Universal AC input / Full range Built in active PFC circuit compliance to EN61000-3-2 Protections: Short circuit / Overload / Over voltage / Over temperature Free air convection for 150W and forced air convection for 225W 3 High power density 4.7w/in Active AC surge current limiting U-bracket low profile:38mm 3 years warranty SPECIFICATION MODEL OUTPUT USP-225-3.3 USP-225-5 USP-225-12 USP-225-15 USP-225-24 USP-225-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 40A 40A 18.7A 15A 9.4A 4.7A CURRENT RANGE 0 ~ 40A 0 ~ 40A 0 ~ 18.7A 0 ~ 15A 0 ~ 9.4A 0 ~ 4.7A RATED POWER 132W 200W 224.4W 225W 225.6W 225.6W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V VOLTAGE TOLERANCE Note.3 INPUT 2.0% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 22ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 72% 77% 2.2A 3.3A 115VAC 1.1A 15A/115VAC 1200ms, 30ms/115VAC at full load 22ms/115VAC at full load 127 ~ 370VDC PF>0.97/115VAC at full load 83% 84% 85% <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 86% 1.6A 30A/230VAC LEAKAGE CURRENT WORKING TEMP. 3.6 ~ 4.4V 5.5 ~ 7.4V 13.2 ~ 16.3V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (RTH2 : detect on heatsink of power transistor) 16.5 ~ 20.2V 26.4 ~ 32.4V 52.8 ~ 64.8V Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 2.0% 0.5% OVER TEMPERATURE OTHERS 2.0% 0.5% PROTECTION OVER VOLTAGE (Note 4) 2.0% 0.5% 230VAC INRUSH CURRENT (Typ.) EMC 2.0% LINE REGULATION AC CURRENT (Typ.) SAFETY & 2.97 ~ 3.6V 2.0% Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A 220K hrs min. MIL-HDBK-217F (25 ) 202*101.5*38mm (L*W*H) 0.85Kg; 16pcs/14.6Kg/0.76CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:USP-225-SPEC 2009-06-29 USP-225 225W Single Output with PFC Function Mechanical Specification Case No. 928 series Unit:mm 202 198.25 60 65.75 FAN Air flow direction 38 8 3.75 15cm 23.5CFM 248.5 93.5 CN2 10 9 8 7 6 5 4 3 2 1 2-M 3 1 2 3 CN1 101.5 3.2 LED FS1 F6.3A/250V AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 11 12 13 14 15 16 17 18 19 20 DC Output Connector (CN2) : MOLEX 39-29-9206 or equivalent Pin No. 1~5 6~15 16~20 Assignment +V -V +V Mating Housing Terminal MOLEX 5557 or equivalent MOLEX 5556 or equivalent Block Diagram fosc : 100KHz ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & P.F.C. RECTIFIERS & FILTER POWER SWITCHING +V -V O.T.P. O.C.P. FG O.L.P. Derating Curve DETECTION CIRCUIT PWM CONTROL O.V.P. Static Characteristics (5V) Ta=25 With18CFM Forced Air Convection 100 80 3.3V,5V Model With 18CFM Forced Air Convection 100 90 80 Free Air Convection 50 70 3.3V,5V Model Free Air Convection LOAD(%) LOAD (%) 65 60 40 20 -20 0 10 20 30 40 45 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 260 INPUT VOLTAGE (V) 60Hz File Name:USP-225-SPEC 2009-06-29